Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Clin Infect Dis ; 72(9): e291-e295, 2021 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-32965474

RESUMEN

BACKGROUND: Detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in blood, also known as RNAemia, has been reported, but its prognostic implications are poorly understood. This study aimed to determine the frequency of SARS-CoV-2 RNA in plasma and its association with coronavirus disease 2019 (COVID-19) clinical severity. METHODS: An analytical cross-sectional study was performed in a single-center tertiary care institution and included consecutive inpatients and outpatients with confirmed COVID-19. The prevalence of SARS CoV-2 RNAemia and the strength of its association with clinical severity variables were examined and included intensive care unit (ICU) admission, invasive mechanical ventilation, and 30-day all-cause mortality. RESULTS: Paired nasopharyngeal and plasma samples were included from 85 patients. The median age was 55 years, and individuals with RNAemia were older than those with undetectable SARS-CoV-2 RNA in plasma (63 vs 50 years; P = .04). Comorbidities were frequent including obesity (37.6%), hypertension (30.6%), and diabetes mellitus (22.4%). RNAemia was detected in 28/85 (32.9%) of patients, including 22/28 (78.6%) who required hospitalization. In models adjusted for age, RNAemia was detected more frequently in individuals who developed severe disease including ICU admission (32.1 vs 14.0%; P = .04) and invasive mechanical ventilation (21.4% vs 3.5%; P = .02). All 4 deaths occurred in individuals with detectable RNAemia. An additional 121 plasma samples from 28 individuals with RNAemia were assessed longitudinally, and RNA was detected for a maximum duration of 10 days. CONCLUSIONS: This study demonstrated a high proportion of SARS-CoV-2 RNAemia, and an association between RNAemia and clinical severity suggesting the potential utility of plasma viral testing as a prognostic indicator for COVID-19.


Asunto(s)
COVID-19 , SARS-CoV-2 , Estudios Transversales , Hospitalización , Humanos , Persona de Mediana Edad , ARN Viral
2.
Emerg Infect Dis ; 26(10): 2487-2488, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32620178

RESUMEN

To investigate the possibility of earlier cases of severe acute respiratory syndrome coronavirus 2 infection than previously recognized, we retrospectively tested pooled samples from 1,700 persons with respiratory signs/symptoms seen at Stanford Health Care, Palo Alto, California, USA, during the last 2 months of 2019. We found no evidence of earlier infection.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , ARN Viral/aislamiento & purificación , Adulto , COVID-19 , California , Humanos , Tamizaje Masivo , Nasofaringe/virología , Pandemias , Estudios Retrospectivos , SARS-CoV-2 , Factores de Tiempo
3.
J Clin Microbiol ; 58(8)2020 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-32461285

RESUMEN

Several point-of-care (POC) molecular tests have received emergency use authorization (EUA) from the Food and Drug Administration (FDA) for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The test performance characteristics of the Accula (Mesa Biotech) SARS-CoV-2 POC test need to be evaluated to inform its optimal use. The aim of this study was to assess the test performance of the Accula SARS-CoV-2 test. The performance of the Accula test was assessed by comparing results of 100 nasopharyngeal swab samples previously characterized by the Stanford Health Care EUA laboratory-developed test (SHC-LDT), targeting the envelope (E) gene. Assay concordance was assessed by overall percent agreement, positive percent agreement (PPA), negative percent agreement (NPA), and Cohen's kappa coefficient. Overall percent agreement between the assays was 84.0% (95% confidence interval [CI], 75.3 to 90.6%), PPA was 68.0% (95% CI, 53.3 to 80.5%), and the kappa coefficient was 0.68 (95% CI, 0.54 to 0.82). Sixteen specimens detected by the SHC-LDT were not detected by the Accula test and showed low viral load burden, with a median cycle threshold value of 37.7. NPA was 100% (95% CI, 94.2 to 100%). Compared to the SHC-LDT, the Accula SARS-CoV-2 test showed excellent negative agreement. However, positive agreement was low for samples with low viral load. The false-negative rate of the Accula POC test calls for a more thorough evaluation of POC test performance characteristics in clinical settings and for confirmatory testing in individuals with moderate to high pretest probability of SARS-CoV-2 who test negative on Accula.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Neumonía Viral/diagnóstico , Pruebas en el Punto de Atención , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Betacoronavirus/genética , COVID-19 , Prueba de COVID-19 , Niño , Preescolar , Infecciones por Coronavirus/virología , Reacciones Falso Negativas , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Nasofaringe/virología , Pandemias , Neumonía Viral/virología , ARN Viral/genética , SARS-CoV-2 , Sensibilidad y Especificidad , Adulto Joven
4.
J Clin Virol ; 138: 104792, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33770659

RESUMEN

BACKGROUND: Significant overlap exists between the symptoms of SARS-CoV-2 and other respiratory viruses. This poses a serious challenge to clinical diagnosis, laboratory testing, and infection control programs. OBJECTIVES: To evaluate the performance of the Hologic Panther Fusion Respiratory Assays (RA) compared to the GenMark ePlex Respiratory Pathogen Panel (RPP) and to assess the ability of the Panther Fusion to perform parallel testing of SARS-CoV-2 and other respiratory viruses from a single sample. STUDY DESIGN: A diagnostic comparison study was carried out using 375 clinical nasopharyngeal specimens. Assay performance was assessed by overall, positive, and negative percent agreement and Cohen's kappa coefficient. RESULTS: Overall agreement between the Fusion RA and ePlex RPP was 97.3 % (95 % CI 96.3-98.0), positive percent agreement was 97.2 % (95 % CI 93.0-99.2), negative percent agreement was 97.3 % (95 % CI 96.3-98.0), and the kappa coefficient was 0.85 (95 % CI 0.81-0.89). Forty additional viruses in 30 specimens were detected by Fusion that were not detected by ePlex. The maximum specimen throughput for parallel testing of the Fusion Respiratory Assays with SARS-CoV-2 was 275 samples in 20.7 h for Fusion SARS-CoV-2 and 350 samples in 20.0 h for Aptima Transcription Mediated Amplification SARS-CoV-2. CONCLUSION: Fusion RA demonstrated substantial agreement compared to the ePlex RPP. However, the Fusion detected respiratory viruses not identified by ePlex, consistent with higher clinical sensitivity. Workflows for parallel testing of respiratory pathogens and SARS-CoV-2 demonstrate that the Panther Fusion instrument provides a flexible, moderate to high throughput testing option for pandemic and seasonal respiratory viruses.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Nasofaringe/virología , ARN Viral/aislamiento & purificación , SARS-CoV-2/aislamiento & purificación , Pruebas Diagnósticas de Rutina , Humanos , Gripe Humana/diagnóstico , Estudios Retrospectivos , Sensibilidad y Especificidad
5.
J Clin Virol ; 136: 104757, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33639409

RESUMEN

BACKGROUND: Measles virus (MeV) is an important cause of acute febrile illness and pediatric mortality globally, with recent U.S. outbreaks associated with under-vaccination. MeV is highly contagious and timely diagnosis is critical to limit spread. RNA detection is the most sensitive method for acute measles diagnosis; however, MeV nucleic acid amplification assays are not widely available. METHODS: We performed a diagnostic accuracy study of a triple-target, real-time RT-PCR (rRT-PCR) assay for simultaneous detection of MeV N, H, and L genes. RESULTS: The MeV triple-target rRT-PCR was tested against serial dilutions (7.0-2.0 log10 copies/mL) of five MeV isolates representing circulating genotypes, and detected 98.7% (74/75) of nasopharyngeal (NP) swab dilutions, 100% (75/75) of plasma dilutions, and 85.3% (64/75) of urine dilutions. MeV RNA detection in urine was markedly improved with the addition of a nucleic acid stabilizing agent. A 95% lower limit of detection (LLOD) of < 3.0 log10 copies/mL was established in each specimen matrix. No cross-reactivity with relevant viruses or interfering substances were identified in specificity studies. The MeV triple-target rRT-PCR detected all three gene targets in a clinical NP swab from an individual with confirmed measles infection. Furthermore, pooled testing from 798 influenza A/B/RSV-negative pediatric NP swabs identified two specimens positive for MeV RNA, confirmed by N gene sequencing to represent shedding of the vaccine-type measles virus. CONCLUSIONS: The MeV triple-target rRT-PCR assay showed high analytic sensitivity across circulating MeV genotypes in three clinically-relevant matrices. Implementation of this assay in the clinical laboratory may facilitate timely diagnosis of acute measles infection and implementation of appropriate infection control interventions.


Asunto(s)
Virus del Sarampión , Sarampión , Centros Médicos Académicos , Niño , Humanos , Sarampión/diagnóstico , Virus del Sarampión/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad
6.
EBioMedicine ; 71: 103546, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34419924

RESUMEN

BACKGROUND: Respiratory virus infections are significant causes of morbidity and mortality, and may induce host metabolite alterations by infecting respiratory epithelial cells. We investigated the use of liquid chromatography quadrupole time-of-flight mass spectrometry (LC/Q-TOF) combined with machine learning for the diagnosis of influenza infection. METHODS: We analyzed nasopharyngeal swab samples by LC/Q-TOF to identify distinct metabolic signatures for diagnosis of acute illness. Machine learning models were performed for classification, followed by Shapley additive explanation (SHAP) analysis to analyze feature importance and for biomarker discovery. FINDINGS: A total of 236 samples were tested in the discovery phase by LC/Q-TOF, including 118 positive samples (40 influenza A 2009 H1N1, 39 influenza H3 and 39 influenza B) as well as 118 age and sex-matched negative controls with acute respiratory illness. Analysis showed an area under the receiver operating characteristic curve (AUC) of 1.00 (95% confidence interval [95% CI] 0.99, 1.00), sensitivity of 1.00 (95% CI 0.86, 1.00) and specificity of 0.96 (95% CI 0.81, 0.99). The metabolite most strongly associated with differential classification was pyroglutamic acid. Independent validation of a biomarker signature based on the top 20 differentiating ion features was performed in a prospective cohort of 96 symptomatic individuals including 48 positive samples (24 influenza A 2009 H1N1, 5 influenza H3 and 19 influenza B) and 48 negative samples. Testing performed using a clinically-applicable targeted approach, liquid chromatography triple quadrupole mass spectrometry, showed an AUC of 1.00 (95% CI 0.998, 1.00), sensitivity of 0.94 (95% CI 0.83, 0.98), and specificity of 1.00 (95% CI 0.93, 1.00). Limitations include lack of sample suitability assessment, and need to validate these findings in additional patient populations. INTERPRETATION: This metabolomic approach has potential for diagnostic applications in infectious diseases testing, including other respiratory viruses, and may eventually be adapted for point-of-care testing. FUNDING: None.


Asunto(s)
Gripe Humana/diagnóstico , Aprendizaje Automático , Metaboloma , Técnicas de Diagnóstico Molecular/métodos , Adolescente , Adulto , Niño , Preescolar , Femenino , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Gripe Humana/metabolismo , Gripe Humana/virología , Masculino , Metabolómica/métodos , Mucosa Nasal/metabolismo , Mucosa Nasal/virología , Orthomyxoviridae/patogenicidad , Ácido Pirrolidona Carboxílico/análisis
7.
J Appl Lab Med ; 5(6): 1307-1312, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32761092

RESUMEN

BACKGROUND: Numerous nucleic acid amplification assays utilizing different target genes of the SARS-CoV-2 genome have received emergency use authorization (EUA) by the United States Food and Drug Administration (FDA). Limited data are available comparing the test performance characteristics of these assays. METHODS: A diagnostic comparison study was performed to evaluate the performance of the Cepheid Xpert Xpress SARS-CoV-2 assay compared to the Hologic Panther Fusion SARS-CoV-2 assay using clinical nasopharyngeal specimens. Agreement between the two assays was assessed by overall, positive, and negative percent agreement and Cohen's kappa coefficient. RESULTS: A total of 104 (54 positive and 50 negative) clinical nasopharyngeal samples were tested by both assays. Using the Panther Fusion as a reference standard, the Xpert demonstrated an overall agreement of 99.0% [95% confidence interval (CI): 94.8-100], positive percent agreement of 98.1% (95% CI: 90.1-100), and a negative percent agreement of 100% (95% CI: 94.2-100). The kappa coefficient was 0.98 (95% CI: 0.94-1.0). One sample positive by the Panther Fusion with a cycle threshold (Ct) of 38.6 was found to be reproducibly negative by the Xpert assay. CONCLUSIONS: The Cepheid Xpert Xpress SARS-CoV-2 assay provides test performance comparable to the Hologic Panther Fusion SARS-CoV-2 assay while offering laboratories rapid, on-demand testing capacity.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Técnicas de Laboratorio Clínico/instrumentación , Infecciones por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/instrumentación , Neumonía Viral/diagnóstico , ARN Viral/aislamiento & purificación , Automatización de Laboratorios/instrumentación , Betacoronavirus/genética , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/estadística & datos numéricos , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/virología , Humanos , Técnicas de Diagnóstico Molecular/estadística & datos numéricos , Reacción en Cadena de la Polimerasa Multiplex/instrumentación , Pandemias , Neumonía Viral/epidemiología , Neumonía Viral/virología , Sistemas de Atención de Punto/estadística & datos numéricos , Juego de Reactivos para Diagnóstico/estadística & datos numéricos , Reacción en Cadena en Tiempo Real de la Polimerasa/instrumentación , Reproducibilidad de los Resultados , SARS-CoV-2 , Factores de Tiempo , Estados Unidos/epidemiología
8.
J Clin Virol ; 127: 104383, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32353760

RESUMEN

BACKGROUND: Numerous nucleic acid amplification assays have recently received emergency use authorization (EUA) for the diagnosis of SARS-CoV-2 infection, and there is a need to assess their test performance relative to one another. OBJECTIVES: The aim of this study was to compare the test performance of the Hologic Panther Fusion SARS-CoV-2 assay targeting two regions of open reading frame 1ab (ORF1ab) to a high complexity molecular-based, laboratory-developed EUA from Stanford Health Care (SHC) targeting the SARS-CoV-2 envelope (E) gene. STUDY DESIGN: We performed a diagnostic comparison study by testing nasopharyngeal samples on the two assays. Assay agreement was assessed by overall percent agreement and Cohen's kappa coefficient. RESULTS: A total of 184 nasopharyngeal samples were tested using the two assays, of which 180 showed valid results and were included for the comparative analysis. Overall percent agreement between the assays was 98.3 % (95 % confidence interval (CI) 95.2-99.7) and kappa coefficient was 0.97 (95 % CI 0.93-1.0). One sample was detected on the SHC laboratory developed test (LDT) and not on the Panther Fusion, and had a Ct of 35.9. Conversely, 2 samples were detected on the Panther Fusion and not on the LDT, and had Ct values of 37.2 and 36.6. CONCLUSION: The Panther Fusion SARS-CoV-2 assay and the SHC LDT perform similarly on clinical nasopharyngeal swab specimens. Other considerations, including reagent availability, turnaround time, labor requirements, cost and instrument throughput should guide the decision of which assay to perform.


Asunto(s)
Infecciones por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Neumonía Viral/diagnóstico , Juego de Reactivos para Diagnóstico/normas , Proteínas del Envoltorio Viral/aislamiento & purificación , Betacoronavirus/genética , COVID-19 , Proteínas de la Envoltura de Coronavirus , Humanos , Nasofaringe/virología , Pandemias , Reproducibilidad de los Resultados , SARS-CoV-2 , Proteínas del Envoltorio Viral/genética
9.
J Clin Virol ; 129: 104427, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32535398

RESUMEN

BACKGROUND: Numerous nucleic acid amplification tests, including real-time, reverse transcription PCR (rRT-PCR) and isothermal amplification methods, have been developed to detect SARS-CoV-2 RNA, including many that have received emergency use authorization (EUA). There is a need to assess their test performance relative to one another. OBJECTIVES: The aim of this study was to compare the test performance of a high complexity laboratory-developed rRT-PCR EUA from Stanford Health Care (SHC) targeting the SARS-CoV-2 envelope (E) gene with other tests: the Atila isothermal amplification assay targeting the nucleocapsid (N) gene and open reading frame 1ab (ORF1ab), the Altona E and spike (S) multiplex, real-time RT-PCR, and the US Centers for Disease Control and Prevention (CDC) N1 and N2 rRT-PCRs. STUDY DESIGN: A diagnostic comparison study was performed by testing nasopharyngeal samples from persons under investigation for coronavirus disease 2019 (COVID-19). Assay performance was assessed by percent agreement and Cohen's kappa coefficient. RESULTS: Positive percent agreement with the SHC EUA reference assay was 82.8 % (95 % confidence interval (CI) 65.0 to 92.9) for Atila, 86.7 % (95 % CI 69.7 to 95.3) for the Altona E and S targets, and 86.7 % (95 % CI 69.7 to 95.3) and 90.0 % (95 % CI 73.6 to 97.3), for the CDC N1 and N2 targets, respectively. All assays demonstrated 100 % negative percent agreement. Kappa coefficients ranged from 0.86 to 0.92, indicating excellent agreement. CONCLUSIONS: Performance was comparable among the SARS-CoV-2 nucleic acid amplification methods tested, with a limited number of discrepancies observed in specimens with low viral loads.


Asunto(s)
Betacoronavirus/genética , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Neumonía Viral/diagnóstico , Proteínas del Envoltorio Viral/genética , COVID-19 , Prueba de COVID-19 , Vacunas contra la COVID-19 , Humanos , Proteínas de la Nucleocápside/genética , Pandemias , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA