1.
Eur J Radiol ; 129: 109065, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32485336

RESUMEN

PURPOSE: To evaluate the effect of various interactive metal artifact reduction (iMAR) algorithms on attenuation correction in the vicinity of port chambers in PET/CT. MATERIAL AND METHODS: In this prospective study, 30 oncological patients (12 female, 18 male, mean age 59.6 ± 10.5y) with implanted port chambers undergoing 18F-FDG PET/CT were included. CT images were reconstructed with standard weighted filtered back projection (WFBP) and three different iMAR algorithms (hip, dental filling (DF) and pacemaker (PM)). PET attenuation correction was performed with all four CT datasets. SUVmean, SUVmax and HU measurements were performed in fat and muscle tissue in the vicinity of the port chamber at the location of the strongest bright and dark band artifacts. Differences between HU and SUV values across all CT- and PET-images were investigated using a paired t-test. Bonferroni correction was used to prevent alpha-error accumulation (p < 0.008). RESULTS: In comparison to WFBP (fat: 94.2 ± 53.9 HU, muscle: 197.6 ± 49.2 HU) all three iMAR algorithms led to a decrease of HU in bright band artifacts. iMAR-DF led to a decrease of 159.2 % (fat: -51.9 ± 58.5 HU, muscle: 94.5 ± 55.3 HU), iMAR-hip of 138.3 % (fat: -30.3 ± 58.5, muscle: 70.4 ± 28.8) and iMAR-PM of 122.3 % (fat: -21.2 ± 47.2 HU, muscle: 72.5 ± 25.1 HU; for all p < 0.008). There was no significant effect of iMAR on SUV measurements in comparison to WFBP. CONCLUSION: iMAR leads to a significant change of HU values in artifacts caused by port catheter chambers in comparison to WFBP. However, no significant differences in attenuation correction and consecutive changes in SUV measurements can be observed.


Asunto(s)
Algoritmos , Artefactos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Dispositivos de Acceso Vascular , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Estudios Prospectivos
2.
Br J Radiol ; 93(1105): 20190069, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31642702

RESUMEN

OBJECTIVE: To evaluate the impact of different metal artifact reduction (MAR) algorithms on Hounsfield unit (HU) and standardized uptake values (SUV) in a phantom setting and verify these results in patients with metallic implants undergoing oncological PET/CT examinations. METHODS AND MATERIALS: In this prospective study, PET-CT examinations of 28 oncological patients (14 female, 14 male, mean age 69.5 ± 15.2y) with 38 different metal implants were included. CT datasets were reconstructed using standard weighted filtered back projection (WFBP) without MAR, MAR in image space (MARIS) and iterative MAR (iMAR, hip algorithm). The three datasets were used for PET attenuation correction. SUV and HU measurements were performed at the site of the most prominent bright and dark band artifacts. Differences between HU and SUV values across the different reconstructions were compared using paired t-tests. Bonferroni correction was used to prevent alpha-error accumulation (p < 0.017). RESULTS: For bright band artifacts, MARIS led to a non-significant mean decrease of 12.0% (345 ± 315 HU) in comparison with WFBP (391 ± 293 HU), whereas iMAR led to a significant decrease of 68.3% (125 ± 185 HU, p < 0.017). For SUVmean, MARIS showed no significant effect in comparison with WFBP (WFBP: 0.99 ± 0.40, MARIS: 0.96 ± 0.39), while iMAR led to a significant decrease of 11.1% (0.88 ± 0.35, p < 0.017). Similar results were observed for dark band artifacts. CONCLUSION: iMAR significantly reduces artifacts caused by metal implants in CT and thus leads to a significant change of SUV measurements in bright and dark band artifacts compared with WFBP and MARIS, thus probably improving PET quantification. ADVANCES IN KNOWLEDGE: The present work indicates that MAR algorithms such as iMAR algorithm in integrated PET/CT scanners are useful to improve CT image quality as well as PET quantification in the evaluation of tracer uptake adjacent to large metal implants. A detailed analysis of oncological patients with various large metal implants using different MAR algorithms in PET/CT has not been conducted yet.


Asunto(s)
Artefactos , Metales , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Prótesis e Implantes , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Anciano , Algoritmos , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Fantasmas de Imagen , Estudios Prospectivos , Radiofármacos