Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Knee Surg Sports Traumatol Arthrosc ; 31(8): 3212-3220, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36810948

RESUMEN

PURPOSE: To carry out an in vivo kinematic analysis of isolated modified Lemaire lateral extra-articular tenodesis (LET) to explore its ability to modify the stability of anterior cruciate ligament (ACL) deficient knees. The secondary aim was to look at the clinical outcomes of the isolated LET to analyze whether biomechanical changes have an influence on clinical improvement or not. METHODS: A total of 52 patients who underwent an isolated modified Lemaire LET were prospectively studied. Twenty-two were over 55-year-old patients with ACL rupture and subjective instability (group 1). They were followed up for 2 years postoperatively. Thirty were patients underwent a two-stage ACL revision (group 2). They were followed up for 4 months postoperatively (up to the second stage of the ACL revision). Preoperative, intraoperative, and postoperative kinematic analyses were carried out using the KiRA accelerometer and KT1000 arthrometer to look for residual anterolateral rotational instability and residual anteroposterior instability. Functional outcomes were measured with the single-leg vertical jump test (SLVJT) and the single-leg hop test (SLHT). Clinical outcomes were evaluated using the IKDC 2000, Lysholm, and Tegner scores. RESULTS: A significant reduction of both rotational and anteroposterior instability was detected. It was present both with the patient under anesthesia (p < 0.001 and p = 0.007 respectively) as well as with the patient awake (p = 0.008 and p = 0.018 respectively). Postoperative analysis of knee laxity did not show any significant variation from the first to the last follow-up. Both the SLVJT and SLHT improved significantly at the last follow-up (p < 0.001 and p = 0.011 respectively). The mean values of both the IKDC and Lysholm and Tegner scores showed an improvement (p = 0.008; p = 0.012; p < 0.001). CONCLUSION: The modified Lemaire LET improves the kinematics of ACL-deficient knees. The improvement in the kinematics leads to an improvement in subjective stability as well as in the function of the knee and in the clinical outcomes. At the 2-year follow-up, these improvements were maintained in a cohort of patients over 55 years. Following our findings, to reduce knee instability, an isolated LET in ACL-deficient knees may be used when ACL reconstruction in patients over 55 years is not indicated. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Inestabilidad de la Articulación , Tenodesis , Humanos , Persona de Mediana Edad , Ligamento Cruzado Anterior/cirugía , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Rodilla/cirugía , Lesiones del Ligamento Cruzado Anterior/complicaciones , Lesiones del Ligamento Cruzado Anterior/cirugía , Inestabilidad de la Articulación/cirugía , Inestabilidad de la Articulación/complicaciones
2.
Int Orthop ; 46(7): 1539-1545, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35411436

RESUMEN

PURPOSE: To determine the correlation between the assessment computed tomography osteochondral allograft (ACTOCA) scoring system and clinical outcomes scores. The hypothesis was that the ACTOCA score would show sufficient correlation to support its use in clinical practice. METHODS: We prospectively collected data from all consecutive patients who underwent cartilage restitution with fresh osteochondral allograft (FOCA) transplantation for osteochondral lesions of the knee and had a minimum follow-up of two years. CT scans were performed at three, six and 24 months post-operatively. A musculoskeletal radiologist blinded to the patients' medical history evaluated the scans using the ACTOCA scoring system. Clinical outcomes collected preoperatively and at three, six and 24 months postoperatively were evaluated using the International Knee Documentation Committee (IKDC), Kujala, the Western Ontario Meniscal Evaluation Tool (WOMET), and the Tegner Activity Scale. RESULTS: The mean total ACTOCA score showed a statistically significant correlation with the clinical outcome. The correlation was optimal at 24 months. We found a high negative correlation with the IKDC, Kujala and Tegner (- 0.737; - 0.757, and - 0.781 respectively), and a moderate negative correlation with WOMET (- 0.566) (p < 0.001). IKDC, Kujala, WOMET, and Tegner scores showed a significant continuous improvement in all scores (p < 0.001). CONCLUSION: The mean total ACTOCA score showed a linear correlation with clinical results in IKDC, Kujala, WOMET, and Tegner scores, being the highest at 24 months post-surgery. This finding supports the use of ACTOCA to standardize CT scan reports following fresh osteochondral allograft transplantation in the knee.


Asunto(s)
Cartílago Articular , Fracturas Intraarticulares , Aloinjertos , Trasplante Óseo/métodos , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/cirugía , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Tomografía Computarizada por Rayos X
3.
Arch Orthop Trauma Surg ; 142(2): 255-261, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33222023

RESUMEN

INTRODUCTION: Vascular injuries after traumatic knee dislocation pose a potential limb threat for the patient. The benefits of external fixation have been described by many authors. However, the usefulness of the external fixator during acute management of knee dislocations with vascular injuries is a controversial aspect that has no consensus in the literature. The purpose of the present study was to provide data from the current literature on the utility of the external fixator and to investigate the percentage of knee dislocations with vascular injuries treated with an external fixator, the timing between external fixator and vascular repair, and the total time of external fixator. MATERIAL AND METHODS: The present systematic review was conducted according to the PRISMA checklist. MEDLINE (Pubmed), Web of Science, and SCOPUS databases were searched for articles from 1 January 2000 to 6 February 2019. Studies reporting outcomes of treatment of knee dislocations with vascular injuries were included. Exclusion criteria included studies investigating chronic knee dislocations, knee arthroplasties, editorials, case reports, and expert opinions. Two authors independently extracted data and appraised the quality of evidence and risk of bias using the Methodological quality and synthesis of case series and case reports. RESULTS: Descriptive statistics were used to report the outcome of our findings. Seven studies related to the usefulness of the external fixator during acute management of knee dislocations with vascular injuries were included. The external fixator had been used in the majority of knee dislocations with vascular lesions (72%). Timing between external fixator and vascular repair was reported on four studies (57%), two studies performed external fixation before vascular repair, and two studies performed external fixation after vascular repair. Total time of external fixator was only reported on three studies, ranging from 3 weeks to 3 months. These studies reported acute management, without referring to long-term results and without comparative groups. CONCLUSIONS: External fixator was used in the majority of knee dislocations with vascular injuries but the justification for its use remained unclear. Larger studies are needed to fully understand the merit of the external fixator in knee dislocations with vascular injuries. Joint protocols between vascular surgeons and trauma surgeons are necessary to agree on the aspects related to the management of knee dislocations with vascular injuries. LEVEL OF EVIDENCE: IV.


Asunto(s)
Luxaciones Articulares , Luxación de la Rodilla , Lesiones del Sistema Vascular , Fijadores Externos , Humanos , Luxación de la Rodilla/cirugía , Articulación de la Rodilla , Lesiones del Sistema Vascular/cirugía
4.
Int Orthop ; 45(5): 1191-1197, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33416905

RESUMEN

AIM OF THE STUDY: To describe a new semiquantitative computed tomography (CT) scoring system for multi-feature analysis of cartilage defect repair by osteochondral allografts for the knee and to assess its intra-observer and inter-observer variability. METHOD: A semiquantitative assessment CT osteochondral allograft (ACTOCA) scoring system was designed based on fresh osteochondral allograft transplantations for the knee. The system includes five CT features: density relative to host bone, integration at the host-graft junction, surface percentage with a discernible cleft at the host-graft junction, cystic changes, and intra-articular fragments. Inter-observer variability was calculated by three observers blinded to the patient's medical history and treatment. Intra-observer variability was also determined. RESULTS: Inter-observer agreement was moderate to substantial for all CT score components and intra-observer agreement was moderate to almost perfect for all CT score components (κ > 0.5, p < 0.05). CONCLUSION: The ACTOCA score is a reliable tool to evaluate integration of osteochondral allograft transplantations. It provides an accurate evaluation of bone changes and may help to standardize CT scan reports following osteochondral allograft transplantation for the knee.


Asunto(s)
Cartílago Articular , Aloinjertos , Trasplante Óseo , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/cirugía , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Variaciones Dependientes del Observador , Tomografía , Tomografía Computarizada por Rayos X
5.
Arthroscopy ; 36(3): 776-784, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31864816

RESUMEN

PURPOSE: The purpose of this study was to analyze postoperative computed tomography (CT) scan evaluations of patients who had undergone a combined anterior cruciate ligament (ACL) reconstruction and modified Lemaire anterolateral tenodesis (ALT) with femoral fixation through a bony tunnel. METHODS: Postoperative CT scans of 52 patients who had undergone combined ACL and ALT were prospectively evaluated. ACL femoral tunnels were drilled through an anteromedial portal in the center of the native footprint. An ALT fixation tunnel was drilled 5 mm proximal to the lateral epicondyle, aiming at an inclination of 30° proximally and 30° anteriorly. Two independent observers evaluated the CT scans measuring any degree of collision, the shortest distance between the tunnels, and the inclination of the ALT tunnels. Measurements were carried out at both the cortical level and on a plane passing 1 cm deeper in the lateral condyle. RESULTS: At the level of the cortex, no convergence of the tunnels was identified. In 14 of 52 cases (26.9%), the shortest distance between the tunnels was less than 5 mm. Tunnel collision occurred in 8 of 52 cases (15.4%), and the bone bridge between the tunnels was less than 5 mm in 11 cases (21.1%) when the measurements were made on the deeper plane. When the inclination on the axial plane was less than 15°, a collision always (P < .001) occurs. When it was more than 20°, no collision occurred (P < .001). No correlation between convergence and the inclination of the ALT tunnel on the coronal plane was detected. CONCLUSIONS: To fix a modified Lemaire ALT through a femoral tunnel avoiding any interference with an anatomic femoral ACL tunnel, we recommend that the femoral tunnel be drilled with an inclination of at least 20° anteriorly. LEVEL OF EVIDENCE: IV, therapeutic case series.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/diagnóstico por imagen , Ligamento Cruzado Anterior/cirugía , Articulación de la Rodilla/cirugía , Tenodesis/métodos , Anciano , Cadáver , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Variaciones Dependientes del Observador , Periodo Posoperatorio , Riesgo , Tomografía Computarizada por Rayos X
6.
Knee Surg Sports Traumatol Arthrosc ; 28(7): 2116-2123, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32239270

RESUMEN

PURPOSE: The management of posterolateral corner (PLC) injuries has significantly evolved over the past 2 decades. The purpose of this study was to determine the current worldview of key concepts on the diagnosis, treatment strategy, and rehabilitation for patients presenting with PLC injuries. METHODS: A 12-question multiple-choice online survey was designed to address key questions in the diagnosis, treatment, and rehabilitation of PLC injuries. The survey was distributed to the most important international sports medicine societies worldwide. Clinical agreement was defined as > 80% of agreement in responses and general agreement was defined as > 60% of agreement in responses. RESULTS: 975 surgeons completed the survey with 49% from Europe, 21% from North America, 12% from Latin America, 12% from Asia, and smaller percentages from Africa and Oceania. Less than 14% of respondents manage more than ten PCL injuries yearly. Clinical agreement of > 80% was only evident in the use of MRI in the diagnosis of PLC injury. Responses for surgical treatment were split between isometric fibular-based reconstruction techniques and anatomically based fibular and tibial-based reconstructions. A general agreement of > 60% was present for the use of a post-operative brace in the early rehabilitation. CONCLUSION: In the global surgical community, there remains a significant variability in the diagnosis, treatment, and postoperative management of PLC injuries. The number of PLC injuries treated yearly by most surgeons remains low. As global clinical consensus for PLC remains elusive, societies will need to play an important role in the dissemination of evidence-based practices for PLC injuries. LEVEL OF EVIDENCE: IV.


Asunto(s)
Traumatismos de la Rodilla/cirugía , Cuidados Posoperatorios , Procedimientos Quirúrgicos Operativos/normas , Adulto , Femenino , Humanos , Internacionalidad , Traumatismos de la Rodilla/diagnóstico , Traumatismos de la Rodilla/rehabilitación , Imagen por Resonancia Magnética , Masculino , Procedimientos Quirúrgicos Operativos/métodos , Encuestas y Cuestionarios
7.
Knee Surg Sports Traumatol Arthrosc ; 26(3): 756-761, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28255659

RESUMEN

PURPOSE: The role of the proximal tibiofibular joint (PTFJ) in tibial plateau fractures is unknown. The purpose of this study was to assess, with finite-element (FE) calculations, differences in interfragmentary movement (IFM) in a split fracture of lateral tibial plateau, with and without intact fibula. It was hypothesized that an intact fibula could positively contribute to the mechanical stabilization of surgically reduced lateral tibial plateau fractures. METHODS: A split fracture of the lateral tibial plateau was recreated in an FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. The fracture was reproduced using geometrical data from patient radiographs, and two models were created: one with intact fibula and other without fibula. A locking screw plate and cannulated screw systems were modelled to virtually reduce the fracture, and 80 kg static body weight was simulated. RESULTS: Under mechanical loads, the maximum interfragmentary movement achieved with the fibula was about 30% lower than without fibula, with both the cannulated screws and the locking plate. When the locking plate model was loaded, intact fibula contributed to lateromedial forces on the fractured fragments, which would be clinically translated into increased normal compression forces in the fractured plane. The intact fibula also reduced the mediolateral forces with the cannulated screws, contributing to stability of the construct. CONCLUSION: This FE model showed that an intact fibula contributes to the mechanical stability of the lateral tibial plateau. In combination with a locking plate fixation, early weight bearing may be allowed without significant IFM, contributing to an early clinical and functional recovery of the patient.


Asunto(s)
Placas Óseas , Tornillos Óseos , Peroné/cirugía , Fijación Interna de Fracturas/métodos , Tibia/lesiones , Fracturas de la Tibia/cirugía , Soporte de Peso , Peroné/diagnóstico por imagen , Peroné/lesiones , Humanos , Imagenología Tridimensional , Radiografía , Tibia/diagnóstico por imagen , Tibia/fisiopatología , Fracturas de la Tibia/diagnóstico , Fracturas de la Tibia/fisiopatología
8.
Int Orthop ; 41(6): 1251-1256, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28405810

RESUMEN

PURPOSE: Traditional classification systems for tibial plateau fractures (TPF) are based on simple radiographs, and intra- and inter-observer variability is low. The aim was to assess intra- and inter-observer variability using traditional systems and some recently described classification systems of TPF in the interpretation of standard radiographs and bidimensional (2D) and tridimensional (3D) computed tomography (CT). METHODS: We studied all patients at two centres who underwent TPF surgery over a three-year period. Demographic data (age, sex, BMI) and mechanism of injury were recorded. Four observers classified each TPF according to the Schatzker, AO, Luo, modified Duparc and Khan classification systems. We calculated intra- and inter-observer variability using the Kappa test. RESULTS: A total of 112 (71 males) patients were included. Mean age was 47.1 years (range 21-86) and mean BMI was 25.2 ± 3.6. Intra- and inter-observer variability was 0.95 and 0.62 for AO, 0.87 and 0.65 for Schaztker, 0.86 and 0.73 for Luo, 0.56 and 0.37 for the modified Duparc, and 0.43 and 0.25 for Khan classifications. CONCLUSIONS: Although previous training could be needed, AO, Schatzker and Luo classifications showed a good reproducibility of TPF assessment from a combination of standard radiographs and 2D and 3D CT images. The results using the Modified Duparc and Khan classifications were less favourable and their use is not therefore recommended.


Asunto(s)
Fracturas de la Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Fracturas de la Tibia/clasificación , Fracturas de la Tibia/cirugía , Adulto Joven
9.
Int Orthop ; 40(10): 2163-2169, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26780714

RESUMEN

PURPOSE: To assess, with finite element (FE) calculations, whether immediate weight bearing would be possible after surgical stabilization either with cannulated screws or with a locking plate in a split fracture of the lateral tibial plateau (LTP). METHODS: A split fracture of the LTP was recreated in a FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. A split fracture of the lateral tibial plateau was reproduced by using geometrical data from patient radiographs. A locking screw plate (LP) and a cannulated screw (CS) systems were modelled to virtually reduce the fracture and 80 kg static body-weight was simulated. RESULTS: While the simulated body-weight led to clinically acceptable interfragmentary motion, possible traumatic bone shear stresses were predicted nearby the cannulated screws. With a maximum estimation of about 1.7 MPa maximum bone shear stresses, the Polyax system might ensure more reasonable safety margins. CONCLUSIONS: Split fractures of the LTP fixed either with locking screw plate or cannulated screws showed no clinically relevant IFM in a FE model. The locking screw plate showed higher mechanical stability than cannulated screw fixation. The locking screw plate might also allow full or at least partial weight bearing under static posture at time zero.


Asunto(s)
Fijación Interna de Fracturas/instrumentación , Fracturas de la Tibia/cirugía , Placas Óseas , Tornillos Óseos , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Humanos , Fracturas de la Tibia/fisiopatología , Soporte de Peso
10.
Arthroscopy ; 31(9): 1764-71, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25911395

RESUMEN

PURPOSE: To determine the best angle to drill the femoral tunnels of the superficial medial collateral ligament (sMCL) and posterior oblique ligament (POL) with concomitant posterior cruciate ligament (PCL) reconstruction to avoid either short tunnels or tunnel collisions. METHODS: Eight cadaveric knees were studied. Double-bundle PCL femoral tunnels were arthroscopically drilled. Drilling of the sMCL and POL tunnels was performed in 4 different combinations of 0° and 30° axial (anteriorly directed) and coronal (proximally directed) angulations. Specimens were scanned with computed tomography to document the relations of the sMCL and POL tunnels to the intercondylar notch and PCL tunnels. A minimum tunnel length of 25 mm was required. RESULTS: When the sMCL femoral tunnel was drilled at 0° axial and 30° coronal (proximally directed) angulations or 30° axial (anteriorly directed) and 0° coronal angulations, the risk of tunnel collision with the PCL tunnels increased in comparison with the remaining evaluated angulations (P < .001). No POL tunnels collided with either PCL tunnel bundle with the exception of tunnels drilled at 0° axial and 30° coronal (proximally directed) angulations, which did so in 3 of 8 cases (P < .001). The minimum required tunnel length was obtained in all the sMCL and POL tunnels (P < .001 and P = .02, respectively). However, some of those angled at 0° on the axial plane violated the intercondylar notch. CONCLUSIONS: When one is performing posteromedial reconstructions with concomitant PCL procedures, the sMCL and POL femoral tunnels should be drilled anteriorly and proximally at both 30° axial and 30° coronal angulations. The POL femoral tunnel may also be angled 0° in the coronal plane. Tunnels at 0° axial angulations showed a shorter distance to the intercondylar notch and a higher risk of collision with the PCL tunnels. CLINICAL RELEVANCE: Specific drilling angles are necessary to avoid short tunnels or collisions between the drilled tunnels when sMCL and POL femoral tunnels are placed with concomitant PCL reconstruction.


Asunto(s)
Ligamentos Colaterales/cirugía , Fémur/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Ligamento Cruzado Posterior/cirugía , Anciano , Anciano de 80 o más Años , Artroscopía , Cadáver , Femenino , Fémur/cirugía , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
11.
Knee Surg Sports Traumatol Arthrosc ; 23(1): 334-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25069570

RESUMEN

PURPOSE: The aim of the study was to determine whether medial meniscal substitution with a polyurethane scaffold (Actifit(®)) improves the outcome of medial meniscal-deficient varus knees undergoing open-wedge high tibial osteotomy. METHODS: Sixty patients with symptomatic varus knees those who underwent open-wedge high tibial osteotomies were prospectively studied. In 30 patients, the medial meniscus was left with a defect larger than 25 mm (Group M). An Actifit(®) device was implanted (Group A) in the remaining 30 patients. Patients were functionally evaluated with WOMET, IKDC and VAS. Patient satisfaction was graded from 0 (not satisfied) to 4 (very satisfied). RESULTS: Both groups were comparable preoperatively. They had similar follow-up periods (31.2 months; range 24-47.5; n.s.). WOMET improved a mean of 53.4 ± 8.4 and 42.4 ± 17.2 points in Groups M and A, respectively (p = 0.002). IKDC improved a mean of 56.7 ± 12 and 50.3 ± 15.6 points in Groups M and A, respectively (n.s.). VAS dropped 5.9 ± 2.1 and 4.7 ± 2.8 points in Groups M and A, respectively (p = 0.006). Patient satisfaction averaged 3.3 ± 0.8 and 3.3 ± 1 in Groups M and A, respectively (n.s.). CONCLUSIONS: Patients with symptomatic varus knees were treated with open-wedge high tibial osteotomies, and a meniscectomy was improved more at short-term follow-up in most of the evaluated functional scores than those patients with concomitant implantation of a medial Actifit(®) implant. However, there was no difference in terms of patient satisfaction with the procedure. Based on the short-term functional results of this study, no data were provided to support medial meniscal substitution with a polyurethane scaffold when an open-wedge high tibial osteotomy is being performed. LEVEL OF EVIDENCE: Prospective comparative study, Level II.


Asunto(s)
Traumatismos de la Rodilla/cirugía , Meniscos Tibiales/cirugía , Osteotomía , Tibia/cirugía , Adulto , Materiales Biocompatibles , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Poliuretanos , Estudios Prospectivos , Prótesis e Implantes , Lesiones de Menisco Tibial , Andamios del Tejido , Resultado del Tratamiento
12.
Arthroscopy ; 29(2): 257-65, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23265690

RESUMEN

PURPOSE: The goal of this study was to determine the best angle at which to drill the femoral tunnels of the popliteus tendon (PT) and fibular collateral ligament (FCL) in combined reconstructive procedures so as to avoid either short tunnels or tunnel collisions with the anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) femoral tunnels. METHODS: Eight cadaveric knees were studied. ACL/PCL femoral tunnels were arthroscopically drilled. PT and FCL tunnels were drilled at 0° and 30° axial and coronal angulations. They were scanned by computed tomography to document relations of the PT and FCL tunnels to the intercondylar notch and ACL/PCL tunnels. A minimum tunnel length of 25 mm was required. RESULTS: Drilling the PT tunnel at 0° axial angulation was associated with an increased risk of tunnel collision with the ACL (P < .001). Interference with the PCL tunnel can be avoided only if the K-wire guiding the PT tunnel is drilled with 30° coronal angulations (P < .001). The minimum tunnel length of the PT could be obtained only with both axial and coronal angulations of 30° (P = .003). Sufficient tunnel lengths of the FCL were obtained at all angulations evaluated (P = .036). However, only the tunnels drilled at 30° axial and 0° coronal angulations did not collapse with the ACL tunnels (P < .001). No intersections between FCL and PT tunnels were observed. CONCLUSIONS: When posterolateral reconstructions are performed in combination with concomitant anterior and posterior cruciate procedures, PT tunnels should be drilled at 30° axial and 30° coronal angulations. FCL tunnels should be drilled at 30° axial and 0° coronal angulations. These angulations should minimize such potential complications as short tunnels or collisions with the ACL/PCL tunnels. CLINICAL RELEVANCE: Specific drilling angles are necessary to avoid short tunnels or collisions between the drilled tunnels when FCL and PT femoral tunnels are performed in multiligament knee reconstructions.


Asunto(s)
Ligamento Cruzado Anterior/cirugía , Fémur/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Procedimientos de Cirugía Plástica/métodos , Ligamento Cruzado Posterior/cirugía , Anciano , Anciano de 80 o más Años , Artroscopía , Cadáver , Ligamentos Colaterales/trasplante , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Tendones/trasplante , Tomografía Computarizada por Rayos X
13.
Knee Surg Sports Traumatol Arthrosc ; 21(7): 1516-22, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22552617

RESUMEN

PURPOSE: To compare the functional and radiographic results between two different horn fixation techniques for meniscal allograft transplant. METHODS: This is a prospective study of 88 meniscal allograft transplants with a mean 5-year follow-up. Forty transplants were performed on the medial compartment and 48 on the lateral compartment. The same surgeon performed all surgeries. Thirty-three grafts were fixed only with sutures (Group A) and 55 only with bony fixation (Group B). Both groups were comparable in terms of age, laterality, time since meniscectomy and preoperative functional and radiographic status. Functional assessment was done with Lysholm and Tegner scores and the Visual Analogical Scale for pain. Joint space narrowing was evaluated in the Rosenberg view. RESULTS: There was a significant improvement in Lysholm, Tegner and VAS scores without differences between Group A and Group B (n.s.). Radiographic evaluation did not show any joint space narrowing (n.s.). No differences in the comparison of all the variables of the two compartments were found. There were complications in 33.3 % of patients in Group A that including 7 graft tears (21.4 %) and in which there was an allograft failure rate of 9 %. Group B showed complications in 16.4 % of the patients and included 4 graft tears (7.3 %, n.s.) with an allograft failure rate of 3.6 %. CONCLUSIONS: Meniscal allograft transplantation with either technique provided good functional and radiographic results at mid-term follow-up. Both graft fixation methods showed no differences relative to functional and radiographic results. There was a considerably higher rate of complications in transplantations performed with the only-suture technique than those with bony fixation, although the difference was not statistically significant with the numbers available. The results suggest that similar functional results should be expected whether the meniscal graft includes bone plugs or not. However, graft tears seem to happen more frequently if the MAT is performed without bony fixation. LEVEL OF EVIDENCE: Prospective comparative study, Level II.


Asunto(s)
Articulación de la Rodilla/cirugía , Meniscos Tibiales/trasplante , Técnicas de Sutura , Adolescente , Adulto , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Estudios Prospectivos , Radiografía , Recuperación de la Función , Trasplante Homólogo , Resultado del Tratamiento
14.
J Knee Surg ; 26 Suppl 1: S50-2, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23288776

RESUMEN

A 16-year-old male who had undergone 6 months before an anterior cruciate ligament (ACL) reconstruction with an autologous hamstring graft fixed with a suspensory fixation device (XoButton device; ConMed Linvatec, Largo, FL), complained of a slightly painful mass in the distal posterolateral aspect of the thigh. The knee was otherwise stable. A 79 × 60 × 17 mm multilobulated tumor surrounding the implant device was observed in magnetic resonance images. The revision arthroscopy showed an intact ACL graft. The tumor was excised through a longitudinal posterolateral approach. It had a myxoid appearance. The undamaged implant was also removed. Two months after surgery, the patient was already asymptomatic. Although most fixation device problems occur in the perioperative period due to an inadequate technique which may lead to graft instability, this case reminds clinicians of the possibility of later developing clinically relevant complications with suspensory fixation devices.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/instrumentación , Migración de Cuerpo Extraño/diagnóstico , Ganglión/diagnóstico , Dispositivos de Fijación Ortopédica/efectos adversos , Adolescente , Migración de Cuerpo Extraño/cirugía , Ganglión/cirugía , Humanos , Imagen por Resonancia Magnética , Masculino , Transferencia Tendinosa/instrumentación , Trasplante Autólogo
15.
Knee Surg Sports Traumatol Arthrosc ; 20(9): 1681-8, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22020961

RESUMEN

PURPOSE: Viable meniscal transplantation has been criticized as an expensive and logistically demanding technique. The purpose was to compare the standard culture medium with another culture medium that is more widely available and easier to work with and to assess the collagen net ultrastructure architecture and the capacity of the preserved cells to produce proteins. METHODS: Ten fresh lateral menisci were harvested. Each meniscus was divided into three parts; control group, fetal-bovinum-serum group and Insulin-Transferrin-Selenium group during 4 weeks. Cell metabolism was assessed with the gene expression of type I collagen, type II collagen and aggrecan. Collagen ultrastructure was assessed with transmission electron microscopy. The Collagen Meniscal Architecture scoring system was used to evaluate the degree of meniscal disarray. RESULTS: Type I collagen was expressed more in the fetal-bovinum-serum group than in the ITS group (P = 0.036). No differences were found between cultured samples and control groups. Type II collagen showed decreased expression in both cultured groups compared with the control group. No differences were observed in the gene expression of aggrecan in either group. No differences were observed when the Collagen Meniscal Architecture scoring system was applied. CONCLUSIONS: Insulin-Transferrin-Selenium-supplemented medium is at least as effective as the fetal-bovinum-serum-supplemented medium to preserve the net architecture of the meniscal tissue. Gene expression of the studied proteins was similar in the Insulin-Transferrin-Selenium group to that observed in the control group at 4 weeks. Insulin-Transferrin-Selenium might be a better alternative and might be used instead of fetal-bovinum-serum or an autologous host serum in order to preserve meniscal tissue, which precludes the necessity of obtaining host serum previously. Thus, viable meniscal transplantation would logistically be less complicated to perform.


Asunto(s)
Meniscos Tibiales/trasplante , Adulto , Anciano , Agrecanos/biosíntesis , Células Cultivadas , Colágeno Tipo I/biosíntesis , Colágeno Tipo II/biosíntesis , Medios de Cultivo , Femenino , Expresión Génica , Humanos , Masculino , Meniscos Tibiales/metabolismo , Meniscos Tibiales/ultraestructura , Microscopía Electrónica de Transmisión , Persona de Mediana Edad , Suero/metabolismo , Conservación de Tejido , Trasplante Homólogo
16.
Am J Sports Med ; 50(14): 3812-3818, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36322380

RESUMEN

BACKGROUND: There is a lack of information regarding the ability of imaging studies to predict clinical outcomes after fresh osteochondral allograft (FOCA) transplantation of the knee. PURPOSE: To determine the value of computed tomography (CT) scans to predict the clinical outcome of FOCA transplantation using the assessment computed tomography osteochondral allograft (ACTOCA) score. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: We prospectively collected data from all consecutive patients who underwent FOCA transplantation for osteochondral knee lesions at one institution between August 2017 and August 2019. All patients were followed up for a minimum of 2 years. CT scans performed 6 months after surgery were evaluated by a musculoskeletal radiologist using the ACTOCA scoring system. The radiologist was blinded to the patient's medical history. Clinical outcomes were assessed preoperatively and at 12 and 30 months postoperatively using the International Knee Documentation Committee (IKDC) score, the Kujala score, the Tegner activity scale, and the Western Ontario Meniscal Evaluation Tool (WOMET) score. RESULTS: A total of 38 cases were included. The ACTOCA score at 6 months after surgery showed a statistically significant correlation with clinical results at 12 and 30 months. The correlation was better at 30 months, showing a high negative correlation with the IKDC score (-0.663) and a moderate negative correlation with the Kujala, WOMET, and Tegner scores (-0.593; -0.547, and -0.593, respectively) (P < .001). CONCLUSION: A statistically significant correlation between the mean ACTOCA score on CT scans at 6 months and the clinical results measured by the IKDC, Kujala, WOMET, and Tegner scores at 30 months confirmed the predictive value of the ACTOCA score for use in clinical practice.


Asunto(s)
Tomografía Computarizada por Rayos X , Humanos , Pronóstico , Estudios de Cohortes , Ontario
17.
Bioengineering (Basel) ; 9(10)2022 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-36290483

RESUMEN

The preservation conditions of fresh osteochondral allografts for clinical applications are critical due their objective: to transplant mature hyaline cartilage containing viable chondrocytes, maintaining their metabolic activity and also preserving the structural and functional characteristics of the extracellular matrix. The aim of the present study was to compare fluorescence confocal microscopy and flow cytometry techniques to evaluate the viability of the chondrocytes present in the osteochondral tissue, in order to determine their effectiveness and thus ensure reproducibility and robustness of the analysis. To this end, osteochondral allografts from human cadaveric donors were preserved at 4 °C for 3 weeks in a preservation medium supplemented with antibiotic and antifungal agents. Cell viability of chondrocytes was determined by monitoring the cartilage for 3 weeks of preservation by confocal fluorescence microscopy and flow cytometry, obtaining cell viabilities of 83.7 ± 2.6% and 55.8 ± 7.8% for week three, respectively. The confocal fluorescence microscopy approach is more advantageous and accurate, as it correlates better with actual cell viability values for monitoring osteochondral graft preservation, detecting only the cells that died a natural death associated with the preservation method.

18.
Arthroscopy ; 27(7): 933-43, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21621373

RESUMEN

PURPOSE: The aim of the study was to evaluate the clinical outcome of a collagen meniscus graft implanted in an injured medial meniscus after a minimum of 10 years' follow-up. METHODS: Twenty-five patients underwent arthroscopic implantation of the collagen meniscus device. They had either persistent compartmental joint line pain due to a previous medial meniscus resection (5 cases) or a large irreparable meniscus tear at arthroscopy (20 cases). Implant failure was defined as infection due to the implant or mechanical failure of the device. Twenty-two patients returned for clinical, functional, and radiographic evaluation. Magnetic resonance imaging was also performed and was analyzed with the criteria of Genovese et al. (where type 3 indicates normal and type 1 indicates completely abnormal). All the aforementioned evaluations were carried out at a minimum of 10 years (range, 10.1 to 12.5 years) after the procedure. RESULTS: The mean Lysholm score improved from 59.9 preoperatively to 89.6 at 1 year (P < .001), and it was 87.5 at final follow-up (P < .001). The results were good or excellent in 83% of the population. No differences were observed when we compared the Lysholm score at 1 year of follow-up with the score at final follow-up (P > .05). The mean pain score on a visual analog scale improved by 3.5 points at final follow-up. Patient satisfaction with the procedure was 3.4 of 4 points. Radiographic evaluation showed either minimal or no narrowing of the joint line. Magnetic resonance imaging showed type 2 in 64% of cases and type 3 in 21%. All cases showed less volume than expected (size type 2 in 89%). The failure rate in the patient population was 8% (2 of 25). There were no complications related to the device. CONCLUSIONS: Although there were several different types of patients and acute and chronic tears were treated in a limited number of patients, meniscal substitution with the collagen meniscal implant provides significant pain relief and functional improvement after a minimum of 10 years' follow-up. The implant generally diminished in size, but the procedure proved to be safe and had a low rate of implant failure on a long-term basis. No development or progression of degenerative knee joint disease was observed in most cases. LEVEL OF EVIDENCE: Level IV, therapeutic case series.


Asunto(s)
Colágeno , Meniscos Tibiales/cirugía , Prótesis e Implantes , Adulto , Artralgia/etiología , Artralgia/cirugía , Artrografía , Artroscopía/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/patología , Laceraciones/etiología , Laceraciones/cirugía , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Procedimientos Ortopédicos/efectos adversos , Dimensión del Dolor , Cuidados Posoperatorios , Estudios Prospectivos , Lesiones de Menisco Tibial , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
19.
Arthroscopy ; 27(6): 817-24, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21624676

RESUMEN

PURPOSE: To compare drilling the femoral tunnel with an offset aimer and BullsEye guide (ConMed Linvatec, Largo, FL) to perform an anatomic single-bundle reconstruction of the anterior cruciate ligament (ACL) through the anteromedial portal. METHODS: Seven matched pairs of cadaveric knees were studied. The intent was to drill the femoral tunnel anatomically in all cases. In group A the femoral tunnel was drilled arthroscopically with an offset aimer. In group B the femoral tunnel was drilled arthroscopically with the BullsEye guide. Two tunnels were drilled through the same entry point in each knee. One was done at 110° of knee flexion and the other at 130°. They were scanned by computed tomography and reconstructed 3-dimensionally. Volume-rendering software was used to document relations of the drilled tunnel to the bony anatomy and tunnel length. RESULTS: In group B the femoral tunnel was placed at the center of the femoral insertion site. The center of the tunnel was 9.4 mm from the high cartilage margin and 8.6 mm from the low cartilage margin. In group A the tunnels were placed deeper (5.4 mm and 12.6 mm, respectively) (P = .018). There were no differences in tunnel length for either knee flexion degree. Three of the tunnels drilled at 110° in group A compromised the posterior tunnel wall and measured less than 25 mm in length. CONCLUSIONS: Accurate placement in the center of the femoral footprint of the ACL is better accomplished with the BullsEye guide rather than 5-mm offset aimers. Five-millimeter offset aimers might cause posterior tunnel blowout and present the risk of obtaining short tunnels when performing oblique femoral tunnel placement through the anteromedial portal at 110° of knee flexion. CLINICAL RELEVANCE: The BullsEye guide might be better than standard offset aimers in the performance of anatomic single-bundle ACL reconstruction.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirugía , Artroscopía/métodos , Fémur/diagnóstico por imagen , Modelos Anatómicos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Ligamento Cruzado Anterior/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior , Cadáver , Femenino , Fémur/cirugía , Humanos , Imagenología Tridimensional , Traumatismos de la Rodilla/diagnóstico por imagen , Traumatismos de la Rodilla/fisiopatología , Traumatismos de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Reproducibilidad de los Resultados
20.
Arthroscopy ; 26(12): 1633-40, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20851561

RESUMEN

PURPOSE: The purpose of this study was to evaluate the functional and radiographic results on a midterm basis, as well as complications, in an initial series of meniscal allograft transplantations performed with suture fixation without any bone block. METHODS: A series of 33 meniscal allograft transplantations were performed at our institution from January 2001 to October 2003. Inclusion criteria were patients with compartmental joint line pain due to a previous meniscectomy. There were 24 men and 9 women with a mean age of 38.8 years (range, 21 to 54 years). The functional outcomes were evaluated by use of Lysholm and Tegner scores at a mean and minimum follow-up of 6.5 years and 5 years, respectively. A visual analog scale for pain was also used. Radiographic assessment included joint space narrowing on the Rosenberg view and magnetic resonance imaging evaluation. RESULTS: The Lysholm and Tegner scores significantly improved from 65.4 to 88.6 (P < .001) and from 3.1 to 5.5 (P < .001), respectively, after surgery. The visual analog scale score significantly dropped from 6.4 to 1.5 (P < .001). The radiographic evaluation did not show any joint space narrowing (P = .38). Meniscal extrusion was a constant finding, averaging 36.3% of total meniscal size. According to the Van Arkel criteria, the survival rate was 87.8% at 6.5 years. The rate of complications was 33%. CONCLUSIONS: This study suggests that this procedure provides significant pain relief and functional improvement in selected symptomatic individuals on a midterm basis. However, there was a high rate of complications (33%) and revision surgery. LEVEL OF EVIDENCE: Level IV, therapeutic case series.


Asunto(s)
Artroscopía/métodos , Meniscos Tibiales/trasplante , Complicaciones Posoperatorias/cirugía , Adulto , Ligamento Cruzado Anterior/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Meniscos Tibiales/diagnóstico por imagen , Meniscos Tibiales/cirugía , Persona de Mediana Edad , Dimensión del Dolor , Complicaciones Posoperatorias/epidemiología , Radiografía , Recuperación de la Función , Recurrencia , Reoperación , Índice de Severidad de la Enfermedad , Encuestas y Cuestionarios , Técnicas de Sutura , Trasplante Homólogo , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA