Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Contemp Dent Pract ; 22(5): 557-561, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34318777

RESUMEN

AIM AND OBJECTIVE: The purpose of this study was to measure the refractive index of four commercially available enamel resin composites, using optical coherence tomography (OCT) and their relationship with the atomic composition of the composite resin fillers utilizing an energy-dispersive X-ray fluorescence spectrometer (EDX). MATERIALS AND METHODS: Four different enamel composites, namely Enamel HRi color UE3, Enamel HFO color GE3, Vit-l-escence color Pearl Frost, and Amelogen Plus color Enamel White were tested. For each composite, disks with different thicknesses were fabricated and then light-cured according to the manufacturer's instructions. The disks were then stored in deionized water under 36.5 °C for at least 7 days. Each of the samples from the four different groups was measured in five distinctive points to analyze the optical and physical length using optical coherence tomography (OCT). Elemental analysis of all four different enamel shades of the composite was done using an EDX. RESULTS: The filler contents showed interesting differences in elemental composition and concentration; however, Si seemed to be a common filler component. The HRi composite presented a distinctive composition compared to other materials and was the only composite that showed a smaller percentage of SiO2, and also was the only composite that contained compounds, such as P2O5, ZnO, CaO, La2O3, and V2O5. The optical coherence tomography analysis showed the refractive index values of all tested enamel composites. Among the four different enamel composite resins tested, the enamel HRi composite demonstrated the most ideal refractive index to mimic natural enamel. CONCLUSION: The enamel HRi composite demonstrated a distinctive filler composition and this could be the main reason behind its higher refractive index. Nonetheless, it remains unclear how much of an impact this feature has in the final esthetic outcome of anterior composite restorations, where many other optical phenomena are also important. CLINICAL SIGNIFICANCE: The clinical success of any esthetic restorative procedure depends on diagnosing the proper treatment plan and also on executing this treatment with the right materials. On direct esthetic restorations, knowing the optical properties of such materials is fundamental, as they should be able to replicate both natural enamel and dentin. How to cite this article: Beolchi RS, Mehta D, Pelissier B, et al. Influence of Filler Composition on the Refractive Index of Four Different Enamel Shades of Composite Resins. J Contemp Dent Pract 2021;22(5):557-561.


Asunto(s)
Materiales Dentales , Refractometría , Color , Resinas Compuestas , Esmalte Dental , Estética Dental , Ensayo de Materiales , Dióxido de Silicio
2.
J Mech Behav Biomed Mater ; 154: 106533, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38598918

RESUMEN

The present work aims to develop a production method of pre-sintered zirconia-toughened-alumina (ZTA) composite blocks for machining in a computer-aided design and computer-aided manufacturing (CAD-CAM) system. The ZTA composite comprised of 80% Al2O3 and 20% ZrO2 was synthesized, uniaxially and isostatically pressed to generate machinable CAD-CAM blocks. Fourteen green-body blocks were prepared and pre-sintered at 1000 °C. After cooling and holder gluing, a stereolithography (STL) file was designed and uploaded to manufacture disk-shaped specimens projected to comply with ISO 6872:2015. Seventy specimens were produced through machining of the blocks, samples were sintered at 1600 °C and two-sided polished. Half of the samples were subjected to accelerated autoclave hydrothermal aging (20h at 134 °C and 2.2 bar). Immediate and aged samples were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Optical and mechanical properties were assessed by reflectance tests and by biaxial flexural strength test, Vickers indentation and fracture toughness, respectively. Samples produced by machining presented high density and smooth surfaces at SEM evaluation with few microstructural defects. XRD evaluation depicted characteristic peaks of alpha alumina and tetragonal zirconia and autoclave aging had no effect on the crystalline spectra of the composite. Optical and mechanical evaluations demonstrated a high masking ability for the composite and a characteristic strength of 464 MPa and Weibull modulus of 17, with no significant alterations after aging. The milled composite exhibited a hardness of 17.61 GPa and fracture toughness of 5.63 MPa m1/2, which remained unaltered after aging. The synthesis of ZTA blocks for CAD-CAM was successful and allowed for the milling of disk-shaped specimens using the grinding method of the CAD-CAM system. ZTA composite properties were unaffected by hydrothermal autoclave aging and present a promising alternative for the manufacture of infrastructures of fixed dental prostheses.


Asunto(s)
Óxido de Aluminio , Cerámica , Ensayo de Materiales , Óxido de Aluminio/química , Cerámica/química , Propiedades de Superficie , Circonio/química , Diseño Asistido por Computadora , Materiales Dentales
3.
J Mech Behav Biomed Mater ; 135: 105451, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36162164

RESUMEN

To evaluate the effect of fatigue and aging on the crystalline content and reliability of a zirconia-toughened-alumina (ZTA) composite compared to its individual counterpart materials (3Y-TZP and Al2O3). Thirty-six disc-shaped specimens per group were obtained to comply with ISO 6872:2015. Crystalline content, microstructure and reliability of experimental groups were evaluated in four stages: 1) immediate; 2) aged; 3) fatigued; 4) aged + fatigue. Aging was performed in autoclave and Step-Stress-Accelerated-Life-Testing (SSALT) was performed using three stress profiles. Weibull statistics were used to determine Weibull parameters and life-expectancy. A significant increase in monoclinic phase in 3Y-TZP was observed after aging (19.31%), fatigue (17.88%) and aging + fatigue (55.81%), while ZTA evidenced minimal variation among all conditions (<5.69%). 3Y-TZP presented higher reliability than ZTA at 300 and 500 MPa, and ZTA outperformed Al2O3 at the same stress missions. None of the ceramics yielded acceptable reliability at 800 MPa. A higher characteristic strength was observed for 3Y-TZP, followed by ZTA and Al2O3. While after aging ZTA and Al2O3 remained stable, 3Y-TZP exhibited a significant increase in the characteristic stress. Aging did not affect the reliability of ZTA and Al2O3. 3Y-TZP demonstrated an increase in monoclinic content and characteristic strength after aging.


Asunto(s)
Óxido de Aluminio , Itrio , Anciano , Óxido de Aluminio/química , Cerámica/química , Materiales Dentales , Humanos , Ensayo de Materiales , Reproducibilidad de los Resultados , Propiedades de Superficie , Itrio/química , Circonio/química
4.
Materials (Basel) ; 14(5)2021 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-33673726

RESUMEN

The fight against cancer is an old challenge for mankind. Apart from surgery and chemotherapy, which are the most common treatments, use of radiation represents a promising, less invasive strategy that can be performed both from the outside or inside the body. The latter approach, also known as brachytherapy, relies on the use of implantable beta-emitting seeds or microspheres for killing cancer cells. A set of radioactive glasses have been developed for this purpose but their clinical use is still mainly limited to liver cancer. This review paper provides a picture of the biomedical glasses developed and experimented for brachytherapy so far, focusing the discussion on the production methods and current limitations of the available options to their diffusion in clinical practice. Highly-durable neutron-activatable glasses in the yttria-alumina-silica oxide system are typically preferred in order to avoid the potentially-dangerous release of radioisotopes, while the compositional design of degradable glass systems suitable for use in radiotherapy still remains a challenge and would deserve further investigation in the near future.

5.
J Biomed Mater Res B Appl Biomater ; 109(8): 1135-1144, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33314536

RESUMEN

To characterize the physicomechanical properties of an alumina-toughened zirconia (ATZ). ATZ synthesis consisted of the addition of alumina particles in an yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP) matrix. Specimens were obtained by uniaxial and isostatic pressing ATZ and 3Y-TZP powders and sintering at 1600°C/1 h and 1550°C/1 h, respectively. Crystalline content and residual stress were evaluated using X-ray diffraction (XRD). Microstructure was characterized by scanning electron microscopy (SEM). Optical properties were determined by reflectance test. Mechanical properties were assessed by biaxial flexural strength test. All analyses were performed before and after aging (134°C, 20 h, 2 bar). XRD and SEM revealed a typical ATZ and 3Y-TZP crystalline content, chiefly tetragonal phase, with a dense polycrystalline matrix, though a smaller grain size for ATZ. Aging triggered a similar monoclinic transformation for both systems; however, ATZ exhibited higher residual compressive stresses than 3Y-TZP. While as-processed 3Y-TZP demonstrated significantly higher characteristic strength relative to ATZ, no significant difference was observed after aging (~215 MPa increase in the ATZ strength). ATZ presented significantly higher opacity relative to 3Y-TZP, although aging significantly increased the translucency of both systems (increase difference significantly higher in the 3Y-TZP compared to ATZ). ATZ physicomechanical properties support its applicability in the dental field, with a lower detrimental effect of aging relative to 3Y-TZP.


Asunto(s)
Óxido de Aluminio/química , Materiales Dentales/química , Ensayo de Materiales , Circonio/química , Presión , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA