Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Cancers (Basel) ; 13(5)2021 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-33801459

RESUMEN

Liquid biopsies hold potential as minimally invasive sources of tumor biomarkers for diagnosis, prognosis, therapy prediction or disease monitoring. We present an approach for parallel single-object identification of circulating tumor cells (CTCs) and tumor-derived large extracellular vesicles (LEVs) based on automated high-resolution immunofluorescence followed by downstream multiplexed protein profiling. Identification of LEVs >6 µm in size and CTC enumeration was highly correlated, with LEVs being 1.9 times as frequent as CTCs, and additional LEVs were identified in 73% of CTC-negative liquid biopsy samples from metastatic castrate resistant prostate cancer. Imaging mass cytometry (IMC) revealed that 49% of cytokeratin (CK)-positive LEVs and CTCs were EpCAM-negative, while frequently carrying prostate cancer tumor markers including AR, PSA, and PSMA. HSPD1 was shown to be a specific biomarker for tumor derived circulating cells and LEVs. CTCs and LEVs could be discriminated based on size, morphology, DNA load and protein score but not by protein signatures. Protein profiles were overall heterogeneous, and clusters could be identified across object classes. Parallel analysis of CTCs and LEVs confers increased sensitivity for liquid biopsies and expanded specificity with downstream characterization. Combined, it raises the possibility of a more comprehensive assessment of the disease state for precise diagnosis and monitoring.

2.
J Mol Diagn ; 22(3): 319-337, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31978562

RESUMEN

Liquid biopsy allows assessment of multiple analytes, providing temporal information with potential for improving understanding of cancer evolution and clinical management of patients. Although liquid biopsies are intensely investigated for prediction and response monitoring, preanalytic variables are of primary concern for clinical implementation, including categories of collection method and sample storage. Herein, an integrated high-density single-cell assay workflow for morphometric and genomic analysis of the liquid biopsy is used to characterize the effects of preanalytical variation and reproducibility of data from a breast cancer cohort. Following prior work quantifying performance of commonly used blood collection tubes, this study completes the analysis of four time points to assay (24, 48, 72, and 96 hours), demonstrating precision up to 48 hours after collection for assay sensitivity, highly reproducible rare cell enumeration, morphometric characterization, and high efficiency and capacity for single-cell genomic analysis. For the cell-free analysis, both freezing and use of fresh plasma produced similar quality and quantity of cell-free DNA for sequencing. The genomic analysis (copy number variation and single-nucleotide variation) described herein is broadly applicable to liquid biopsy platforms capable of isolating cell-free and cell-based DNA. Morphometric parameters and genomic signatures of individual circulating tumor cells were evaluated in relation to patient clinical response, providing preliminary evidence of clinical validity as a potential biomarker aiding clinical diagnostics or monitoring progression.


Asunto(s)
Biomarcadores de Tumor , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/genética , Genómica , Biopsia Líquida , Ácidos Nucleicos Libres de Células , Variaciones en el Número de Copia de ADN , Femenino , Genómica/métodos , Humanos , Biopsia Líquida/métodos , Células Neoplásicas Circulantes , Polimorfismo de Nucleótido Simple , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Análisis de la Célula Individual/métodos , Flujo de Trabajo
3.
Oncotarget ; 10(66): 7016-7030, 2019 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-31903162

RESUMEN

As cancer care is transitioning to personalized therapies with necessary complementary or companion biomarkers there is significant interest in determining to what extent non-invasive liquid biopsies reflect the gold standard solid biopsy. We have established an approach for measuring patient-specific circulating and solid cell concordance by introducing tumor touch preparations to the High-Definition Single Cell Analysis workflow for high-resolution cytomorphometric characterization of metastatic colorectal cancer (mCRC). Subgroups of cells based on size, shape and protein expression were identified in both liquid and solid biopsies, which overall displayed high inter- and intra- patient pleomorphism at the single-cell level of analysis. Concordance of liquid and solid biopsies was patient-dependent and between 0.1-0.9. Morphometric variables displayed particularly high correlation, suggesting that circulating cells do not represent distinct subpopulations from the solid tumor. This was further substantiated by significant decrease in concentration of circulating cells after mCRC resection. Combined with the association of circulating cells with tumor burden and necrosis of hepatic lesions, our overall findings demonstrate that liquid biopsy cells can be informative biomarkers in the mCRC setting. Patient-specific level of concordance can readily be measured to establish the utility of circulating cells as biomarkers and define biosignatures for liquid biopsy assays.

4.
Microarrays (Basel) ; 5(2)2016 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-27600082

RESUMEN

Antibody microarrays have emerged as an important tool within proteomics, enabling multiplexed protein expression profiling in both health and disease. The design and performance of antibody microarrays and how they are processed are dependent on several factors, of which the interplay between the antibodies and the solid surfaces plays a central role. In this study, we have taken on the first comprehensive view and evaluated the overall impact of solid surfaces on the recombinant antibody microarray design. The results clearly demonstrated the importance of the surface-antibody interaction and showed the effect of the solid supports on the printing process, the array format of planar arrays (slide- and well-based), the assay performance (spot features, reproducibility, specificity and sensitivity) and assay processing (degree of automation). In the end, two high-end recombinant antibody microarray technology platforms were designed, based on slide-based (black polymer) and well-based (clear polymer) arrays, paving the way for future large-scale protein expression profiling efforts.

5.
Future Sci OA ; 1(3): FSO1, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28031876

RESUMEN

BACKGROUND: We introduce the combination of digital holographic microscopy (DHM) and antibody microarrays as a powerful tool to measure morphological changes in specifically antibody-captured cells. The aim of the study was to develop DHM for analysis of cell death of etoposide-treated suspension cells. RESULTS/METHODOLOGY: We demonstrate that the cell number, mean area, thickness and volume were noninvasively measured by using DHM. The cell number was stable over time, but the two cell lines showed changes of cell area and cell irregularity after treatment. The cell volume in etoposide-treated cells was decreased, whereas untreated cells showed stable volume. CONCLUSION: Our results provide proof of concept for using DHM combined with antibody-based microarray technology for detecting morphological changes in captured cells.

6.
Int J Proteomics ; 2015: 587250, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26587286

RESUMEN

Background. Pancreatic ductal adenocarcinoma (PDAC) is an aggressive disease with rapid tumor progression and poor prognosis. This study was motivated by the lack of sensitive and specific PDAC biomarkers and aimed to identify a diagnostic, serum protein signature for PDAC. Methods. To mimic a real life test situation, a multicenter trial comprising a serum sample cohort, including 338 patients with either PDAC or other pancreatic diseases (OPD) and controls with nonpancreatic conditions (NPC), was analyzed on 293-plex recombinant antibody microarrays targeting immunoregulatory and cancer-associated antigens. Results. Serum samples collected from different hospitals were analyzed and showed that (i) sampling from five different hospitals could not be identified as a preanalytical variable and (ii) a multiplexed biomarker signature could be identified, utilizing up to 10 serum markers that could discriminate PDAC from controls, with sensitivities and specificities in the 91-100% range. The first protein profiles associated with the location of the primary tumor in the pancreas could also be identified. Conclusions. The results demonstrate that robust enough serum signatures could be identified in a multicenter trial, potentially contributing to the development of a multiplexed biomarker immunoassay for improved PDAC diagnosis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA