1.
Neonatology ; 92(1): 1-7, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17596730

RESUMEN

BACKGROUND: Refinement of ventilatory techniques remains a challenge given the persistence of chronic lung disease of preterm infants. METHODS: To test the hypothesis that proportional assist ventilation (PAV) will allow to lower the ventilator pressure at equivalent fractions of inspiratory oxygen (FiO(2)) and arterial hemoglobin oxygen saturation in ventilator-dependent extremely low birth weight infants in comparison with standard patient-triggered ventilation (PTV). DESIGN: Randomized crossover design. SETTING: Two level-3 university perinatal centers. PATIENTS: 22 infants (mean (SD): birth weight, 705 g (215); gestational age, 25.6 weeks (2.0); age at study, 22.9 days (15.6)). INTERVENTIONS: One 4-hour period of PAV was applied on each of 2 consecutive days and compared with epochs of standard PTV. RESULTS: Mean airway pressure was 5.64 (SD, 0.81) cm H(2)O during PAV and 6.59 (SD, 1.26) cm H(2)O during PTV (p < 0.0001), the mean peak inspiratory pressure was 10.3 (SD, 2.48) cm H(2)O and 15.1 (SD, 3.64) cm H(2)O (p < 0.001), respectively. The FiO(2) (0.34 (0.13) vs. 0.34 (0.14)) and pulse oximetry readings were not significantly different. The incidence of arterial oxygen desaturations was not different (3.48 (3.2) vs. 3.34 (3.0) episodes/h) but desaturations lasted longer during PAV (2.60 (2.8) vs. 1.85 (2.2) min of desaturation/h, p = 0.049). PaCO(2) measured transcutaneously in a subgroup of 12 infants was similar. One infant met prespecified PAV failure criteria. No adverse events occurred during the 164 cumulative hours of PAV application. CONCLUSIONS: PAV safely maintains gas exchange at lower mean airway pressures compared with PTV without adverse effects in this population. Backup conventional ventilation breaths must be provided to prevent apnea-related desaturations.


Asunto(s)
Recien Nacido con Peso al Nacer Extremadamente Bajo/fisiología , Enfermedades Pulmonares/terapia , Respiración Artificial/métodos , Resistencia de las Vías Respiratorias/fisiología , Dióxido de Carbono/metabolismo , Enfermedad Crónica , Estudios Cruzados , Humanos , Recién Nacido , Recien Nacido Prematuro , Presión Parcial , Intercambio Gaseoso Pulmonar/fisiología
2.
Pediatrics ; 110(3): 529-33, 2002 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12205255

RESUMEN

OBJECTIVE: Volume guarantee (synchronized intermittent mandatory ventilation [SIMV]+VG) is a novel mode of SIMV for automatic adjustment of the peak inspiratory pressure to ensure a minimum set mechanical tidal volume (V(T mech)). The objective of this study was to compare the effects of SIMV+VG with conventional SIMV on ventilation and gas exchange in a group of very low birth weight infants recovering from acute respiratory failure. METHODS: Nine infants were initially studied during 2 consecutive 60-minute ventilatory modalities of conventional SIMV (ventilator settings by clinical team) and SIMV+VG 4.5 (V(T mech) set at 4.5 mL/kg) in random order. Eight additional infants were studied during the same ventilatory modalities plus 1 additional epoch consisting of SIMV+VG 3.0 (V(T mech) set at 3.0 mL/kg). RESULTS: Peak inspiratory pressure was significantly lower during SIMV+VG 3.0. Mean airway pressure, V(T mech), number of large V(T mech) (>7 mL/kg), and mechanical minute ventilation (V'(E)) were reduced during SIMV+VG 4.5 compared with SIMV and were further reduced during SIMV+VG 3.0. Spontaneous V'(E) increased during SIMV+VG 4.5 and was even higher during SIMV+VG 3.0. The resulting total V'(E) was higher during both SIMV+VG modes compared with SIMV. Arterial oxygen saturation by pulse oximetry, transcutaneous carbon dioxide tension, and fraction of inspired oxygen did not differ significantly, although transcutaneous carbon dioxide tension increased slightly during SIMV+VG 3.0. CONCLUSIONS: The short-term use of SIMV+VG resulted in automatic weaning of the mechanical support and enhancement of the spontaneous respiratory effort while maintaining gas exchange relatively unchanged in comparison to conventional SIMV.


Asunto(s)
Ventilación con Presión Positiva Intermitente , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Humanos , Recién Nacido , Recien Nacido Prematuro , Recién Nacido de muy Bajo Peso , Ventilación con Presión Positiva Intermitente/métodos , Pruebas de Función Respiratoria , Desconexión del Ventilador