Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38592419

RESUMEN

Medical imaging is both valuable and essential in the care of patients. Much of this imaging depends on ionizing radiation with attendant responsibilities for judicious use when performing an examination. This responsibility applies in settings of both individual as well as multiple (recurrent) imaging with associated repeated radiation exposures. In addressing the roles and responsibilities of the medical communities in the paradigm of recurrent imaging, both the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) have issued position statements, each affirmed by other organizations. The apparent difference in focus and approach has resulted in a lack of clarity and continued debate. Aiming towards a coherent approach in dealing with radiation exposure in recurrent imaging, the IAEA convened a panel of experts, the purpose of which was to identify common ground and reconcile divergent perspectives. The effort has led to clarifying recommendations for radiation exposure aspects of recurrent imaging, including the relevance of patient agency and the provider-patient covenant in clinical decision-making. CLINICAL RELEVANCE STATEMENT: An increasing awareness, generating some lack of clarity and divergence in perspectives, with patients receiving relatively high radiation doses (e.g., ≥ 100 mSv) from recurrent imaging warrants a multi-stakeholder accord for the benefit of patients, providers, and the imaging community. KEY POINTS: • Recurrent medical imaging can result in an accumulation of exposures which exceeds 100 milli Sieverts. • Professional organizations have different perspectives on roles and responsibilities for recurrent imaging. • An expert panel reconciles differing perspectives for addressing radiation exposure from recurrent medical imaging.

2.
Radiology ; 298(3): E141-E151, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33170104

RESUMEN

Background There is lack of guidance on specific CT protocols for imaging patients with coronavirus disease 2019 (COVID-19) pneumonia. Purpose To assess international variations in CT utilization, protocols, and radiation doses in patients with COVID-19 pneumonia. Materials and Methods In this retrospective data collection study, the International Atomic Energy Agency coordinated a survey between May and July 2020 regarding CT utilization, protocols, and radiation doses from 62 health care sites in 34 countries across five continents for CT examinations performed in patients with COVID-19 pneumonia. The questionnaire obtained information on local prevalence, method of diagnosis, most frequent imaging, indications for CT, and specific policies on use of CT in COVID-19 pneumonia. Collected data included general information (patient age, weight, clinical indication), CT equipment (CT make and model, year of installation, number of detector rows), scan protocols (body region, scan phases, tube current and potential), and radiation dose descriptors (CT dose index and dose length product). Descriptive statistics and generalized estimating equations were performed. Results Data from 782 patients (median age, 59 years [interquartile range, 15 years]) from 54 health care sites in 28 countries were evaluated. Less than one-half of the health care sites used CT for initial diagnosis of COVID-19 pneumonia and three-fourths used CT for assessing disease severity. CT dose index varied based on CT vendors (7-11 mGy; P < .001), number of detector rows (8-9 mGy; P < .001), year of CT installation (7-10 mGy; P = .006), and reconstruction techniques (7-10 mGy; P = .03). Multiphase chest CT examinations performed at 20% of sites (11 of 54) were associated with higher dose length product compared with single-phase chest CT examinations performed in 80% of sites (43 of 54) (P = .008). Conclusion CT use, scan protocols, and radiation doses in patients with coronavirus disease 2019 pneumonia showed wide variation across health care sites within the same and between different countries. Many patients were imaged multiple times and/or with multiphase CT scan protocols. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Lee in this issue.


Asunto(s)
COVID-19/diagnóstico por imagen , Protocolos Clínicos , Internacionalidad , Pulmón/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , SARS-CoV-2
3.
Can Assoc Radiol J ; 72(3): 381-387, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32063009

RESUMEN

PURPOSE: To assess the frequency, appropriateness, and radiation doses associated with multiphase computed tomography (CT) protocols for routine chest and abdomen-pelvis examinations in 18 countries. MATERIALS AND METHODS: In collaboration with the International Atomic Energy Agency, multi-institutional data on clinical indications, number of scan phases, scan parameters, and radiation dose descriptors (CT dose-index volume; dose-length product [DLP]) were collected for routine chest (n = 1706 patients) and abdomen-pelvis (n = 426 patients) CT from 18 institutions in Asia, Africa, and Europe. Two radiologists scored the need for each phase based on clinical indications (1 = not indicated, 2 = probably indicated, 3 = indicated). We surveyed 11 institutions for their practice regarding single-phase and multiphase CT examinations. Data were analyzed with the Student t test. RESULTS: Most institutions use multiphase protocols for routine chest (10/18 institutions) and routine abdomen-pelvis (10/11 institutions that supplied data for abdomen-pelvis) CT examinations. Most institutions (10/11) do not modify scan parameters between different scan phases. Respective total DLP for 1-, 2-, and 3-phase routine chest CT was 272, 518, and 820 mGy·cm, respectively. Corresponding values for 1- to 5-phase routine abdomen-pelvis CT were 400, 726, 1218, 1214, and 1458 mGy cm, respectively. For multiphase CT protocols, there were no differences in scan parameters and radiation doses between different phases for either chest or abdomen-pelvis CT (P = 0.40-0.99). Multiphase CT examinations were unnecessary in 100% of routine chest CT and in 63% of routine abdomen-pelvis CT examinations. CONCLUSIONS: Multiphase scan protocols for the routine chest and abdomen-pelvis CT examinations are unnecessary, and their use increases radiation dose.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Procedimientos Innecesarios/estadística & datos numéricos , Abdomen/diagnóstico por imagen , Adulto , África , Asia , Protocolos Clínicos , Pruebas Diagnósticas de Rutina/estadística & datos numéricos , Europa (Continente) , Femenino , Humanos , Masculino , Pelvis/diagnóstico por imagen , Radiografía Torácica , Encuestas y Cuestionarios , Cavidad Torácica/diagnóstico por imagen
4.
Eur Radiol ; 23(3): 623-31, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22940731

RESUMEN

OBJECTIVE: To survey procedures and protocols in paediatric computed tomography (CT) in 40 less resourced countries. METHODS: Under a project of the International Atomic Energy Agency, 146 CT facilities in 40 countries of Africa, Asia, Europe and Latin America responded to an electronic survey of CT technology, exposure parameters, CT protocols and doses. RESULTS: Modern MDCT systems are available in 77 % of the facilities surveyed with dedicated paediatric CT protocols available in 94 %. However, protocols for some age groups were unavailable in around 50 % of the facilities surveyed. Indication-based protocols were used in 57 % of facilities. Estimates of radiation dose using CTDI or DLP from standard CT protocols demonstrated wide variation up to a factor of 100. CTDI(vol) values for the head and chest were between two and five times those for an adult at some sites. Sedation and use of shielding were frequently reported; immobilisation was not. Records of exposure factors were kept at 49 % of sites. CONCLUSION: There is significant potential for improvement in CT practice and protocol use for children in less resourced countries. Dose estimates for young children varied widely. This survey provides critical baseline data for ongoing quality improvement efforts by the IAEA.


Asunto(s)
Accesibilidad a los Servicios de Salud/estadística & datos numéricos , Pediatría/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Protección Radiológica/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , África/epidemiología , Asia/epidemiología , Europa (Continente)/epidemiología , Encuestas de Atención de la Salud , Humanos , América Latina/epidemiología , Dosis de Radiación
5.
Phys Med ; 111: 102618, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37311337

RESUMEN

PURPOSE: Safety in Radiation Oncology (SAFRON) is a reporting and learning system on radiotherapy and radionuclide therapy incidents and near misses. The primary aim of this paper is to examine whether any discernible patterns exist in the causes of reported incidents and safety barriers within the SAFRON system concerning external beam radiotherapy. METHODS AND MATERIALS: This study focuses on external beam radiotherapy incidents, reviewing 1685 reports since the inception of SAFRON until December 2021. Reports that did not identify causes of incidents and safety barriers were excluded from the final study population. RESULTS: Simple two-dimensional radiotherapy or electron beam therapy were represented by 97 reports, three-dimensional conformal radiotherapy by 39 reports, modulated arc therapy by 12 reports, intensity modulated radiation therapy by 11 reports, stereotactic radiosurgery by 4 reports, and radiotherapy with protons or other particles by 1 report, while for 92 of them, no information on treatment method had been provided. Most of the reported incidents were minor incidents and were discovered by the radiation therapist. Inadequate direction/information in staff communication was the most frequently reported cause of incident, and regular independent chart check was the most common safety barrier. CONCLUSIONS: The results indicate that the majority of incidents were reported by radiation therapists, and the majority of these incidents were classified as minor. Communication problems and failure to follow standards/procedures/practices were the most frequent causes of incidents. Furthermore, regular independent chart checking was the most frequently identified safety barrier.


Asunto(s)
Oncología por Radiación , Radiocirugia , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Humanos , Aprendizaje , Gestión de Riesgos/métodos
6.
AJR Am J Roentgenol ; 198(5): 1021-31, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22528891

RESUMEN

OBJECTIVE: The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use. MATERIALS AND METHODS: Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT facilities at 126 hospitals. RESULTS: The lowest frequency of pediatric CT examinations in 2009 was in European facilities (4.3%), and frequencies in Asia (12.2%) and Africa (7.8%) were twice as high. Head CT is the most common CT examination in children, amounting to nearly 75% of all pediatric CT examinations. Although regulations in many countries assign radiologists with the main responsibility of deciding whether a radiologic examination should be performed, in fact, radiologists alone were responsible for only 6.3% of situations. Written referral guidelines for imaging were not available in almost one half of the CT facilities. Appropriateness criteria for CT examinations in children did not always follow guidelines set by agencies, in particular, for patients with accidental head trauma, infants with congenital torticollis, children with possible ventriculoperitoneal shunt malfunction, and young children (< 5 years old) with acute sinusitis. In about one third of situations, nonavailability of previous images and records on previously received patient doses have the potential to lead to unnecessary examinations and radiation doses. CONCLUSION: With increasing use of CT in children and a lack of use of appropriateness criteria, there is a strong need to implement guidelines to avoid unnecessary radiation doses to children.


Asunto(s)
Pautas de la Práctica en Medicina/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , África , Asia , Niño , Preescolar , Europa (Continente) , Humanos , Lactante , Recién Nacido , Agencias Internacionales , América Latina , Dosis de Radiación , Protección Radiológica , Encuestas y Cuestionarios
7.
Phys Med ; 102: 27-32, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36049319

RESUMEN

PURPOSE: The purpose of our retrospective study was to assess the effect of barium sulfate contrast medium on radiation dose and diagnostic quality of CT Pulmonary Angiography (CTPA) in an in-vivo study of pregnant patients. METHODS: Our retrospective study included 33 pregnant patients who underwent CTPA to exclude pulmonary embolism. The patients received oral 40% w/v barium solution just prior to the acquisition of their planning radiograph. All CTPA were performed on 64-slice, single-source CT scanners with AEC with noise index = 28.62-31.64 and the allowed mA range of 100-450. However, only 5/33 patients had mA modulation (AEC 100-450 mA range), while 28/33 patients had mA maxed out at the set maximum mA of 450 over the entire scan range. We recorded CTDIvol (mGy), DLP (mGy.cm) and scan length. The same information was recorded in weight-and scanner-matched, non-pregnant patients. Statistical tests included descriptive data (median and interquartile range) and Mann-Whitney test. RESULTS: There were no significant differences in CTDIvol and DLP between the barium and control group patients (p > 0.1). The median mA below the diaphragm was significantly higher in each patient with barium compared to the weight and scanner-matched patient without barium. Evaluation of lung and subsegmental lower lobe pulmonary arteries was limited in 85% barium group. Due to thin prospective section thickness (1.25 mm), most patients were scanned at maximum allowed mA for AEC. CONCLUSION: Use of AEC with thick barium in pregnant patients undergoing CTPA as an internal radioprotective shield produces counterproductive artifacts and tube current increments.


Asunto(s)
Angiografía , Sulfato de Bario , Humanos , Angiografía/efectos adversos , Bario , Angiografía por Tomografía Computarizada , Medios de Contraste , Pulmón/diagnóstico por imagen , Estudios Prospectivos , Dosis de Radiación , Estudios Retrospectivos
8.
Clin Transl Radiat Oncol ; 34: 57-66, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35345867

RESUMEN

Background: The Southeast European (SEE) region of 10 countries and about 43 million people differs from Western Europe in that most SEE countries lack active cancer registries and have fewer diagnostic imaging devices and radiotherapy (RT) units. The main objective of this research is to initiate a common platform for gathering SEE regional cancer data from the ground up to help these countries develop common cancer management strategies. Methods: To obtain detailed on-the-ground information, we developed separate questionnaires for two SEE groups: a) ONCO - oncologists regarding cancer treatment modalities and the availability of diagnostic imaging and radiotherapy equipment; and b) REG - national radiation protection and safety regulatory bodies regarding diagnostic imaging and radiotherapy equipment in SEE facilities. Results: Based on responses from 13/17 ONCO participants (at least one from each country) and from 9/10 REG participants (all countries but Albania), cancer incidence rates are higher in those SEE countries that have greater access to diagnostic imaging equipment while cancer mortality-to-incidence (MIR) ratios are higher in countries that lack radiotherapy equipment. Conclusion: By combining unique SEE region information with data available from major global databases, we demonstrated that the availability of diagnostic imaging and radiotherapy equipment in the SEE countries is related to their economic development. While immediate diagnostic imaging and radiation therapy capacity building is necessary, it is also essential to develop both national and SEE-regional cancer registries in order to understand the heterogeneity of each country's needs and to establish regional collaborative strategies for combating cancer.

9.
Adv Radiat Oncol ; 6(6): 100772, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34805620

RESUMEN

PURPOSE: A recent initiative was launched for establishing the South-East European International Institute for Sustainable Technologies (SEEIIST), which will provide a cutting-edge Hadron radiation therapy treatment and research institute for treating cancer patients with Hadron therapy (HT). To justify the initiative for building the SEEIIST facility, a study was conducted to estimate the number of patients with cancer from the SEE region that would be eligible for HT. METHODS AND MATERIALS: Two different methods for projecting the future annual cancer incidence have been applied: (1) using the International Agency on Research on Cancer@World Health Organization's (WHO) Globocan model which uses country's demographic factors, and (2) averaging the crude incidence data of 3 SEE countries with available national cancer registries, using a linear regression model of combined incidence per 100,000, and applying it to the entire SEE region. Cancer epidemiology data were collected and studied by using the countries' cancer datasheets from WHO. The top 10 cancers were presented for the SEE region. Studies of other countries were used to develop a primordial model for estimating the number of SEE patients who could be treated most successfully with HT upon SEEIIST commissioning in 2030. RESULTS: A model was developed to estimate the number of eligible patients for HT from SEE. It is estimated that 2900 to 3200 patients per year would be eligible for HT in the new SEEIIST facility in 2030. CONCLUSIONS: After commissioning, SEEIIST will initially treat approximately 400 patients per year, progressing toward 1000. Creation of SEEIIST dedicated patient selection criteria will be both necessary and highly challenging.

10.
Eur J Radiol ; 126: 108923, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32171911

RESUMEN

PURPOSE: Patients with hematuria and renal colic often undergo CT scanning. The purpose of our study was to assess variations in CT protocols and radiation doses for evaluation of hematuria and urinary stones in 20 countries. METHOD: The International Atomic Energy Agency (IAEA) surveyed practices in 51 hospitals from 20 countries in the European region according to the IAEA Technical cooperation classification and obtained following information for three CT protocols (urography, urinary stones, and routine abdomen-pelvis CT) for 1276 patients: patient information (weight, clinical indication), scanner information (scan vendor, scanner name, number of detector rows), scan parameters (such as number of phases, scan start and end locations, mA, kV), and radiation dose descriptors (CTDIvol, DLP). Two radiologists assessed the appropriateness of clinical indications and number of scan phases using the ESR Referral Guidelines and ACR Appropriateness Criteria. Descriptive statistics and Student's t tests were performed. RESULTS: Most institutions use 3-6 phase CT urography protocols (80 %, median DLP 1793-3618 mGy.cm) which were associated with 2.4-4.9-fold higher dose compared to 2-phase protocol (20 %, 740 mGy.cm) (p < 0.0001). Likewise, 52 % patients underwent 3-5 phase routine abdomen- pelvis CT (1574-2945 mGy.cm) as opposed to 37 % scanned with a single-phase routine CT (676 mGy.cm). The median DLP for urinary stones CT (516 mGy.cm) were significantly lower than the median DLP for the other two CT protocols (p < 0.0001). CONCLUSIONS: Few institutions (4/13) use low dose CT for urinary stones. There are substantial variations in CT urography and routine abdomen-pelvis CT protocols result in massive radiation doses (up to 2945-3618 mGy.cm).


Asunto(s)
Hematuria/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Cálculos Urinarios/diagnóstico por imagen , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema Urinario/diagnóstico por imagen , Urografía/métodos
11.
Dentomaxillofac Radiol ; 48(8): 20190157, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31530009

RESUMEN

OBJECTIVES: Cone beam CT (CBCT) in dentistry and maxillofacial surgery is a widely used imaging method for the assessment of various maxillofacial and dental pathological conditions. The objective of this study was to summarize the results of a multinational retrospective-prospective study that focused on patient exposure in this modality. METHODS: The study included 27 CBCT units and 325 adult and paediatric patients, in total. Data on patients, clinical indications, technical parameters of exposure, patient dose indicator, or, alternatively, dose to phantom were collected. The dose indicator used was air kerma-area product, PKA. RESULTS: In most scanners operators are offered with a variety of options regarding technical parameters, especially the field of view size. The median and the third quartile value of PKA for adult patients in 14 different facilities were 820 mGy cm² and 1000 mGy cm² (interquartile range = 1058 mGy cm²), and 653 mGy cm² and 740 mGy cm² (interquartile range = 1179 mGy cm²) for children, as reported by four different institutions. Phantom dose data were reported from 15 institutions, and median PKA ranged from 125 mGy cm² to 1951 mGy cm². Median PKA values varied by more than a 10-fold between institutions, mainly due to differences in imaging protocol used, in particular field of view and tube current-exposure time product. CONCLUSIONS: The results emphasize the need for a cautious approach to using dental CBCT. Imaging only when the clinical indications are clear, accompanied with the appropriate radiographic techniques and the optimum imaging protocol, will help reduce radiation dose to patients.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Pautas de la Práctica en Odontología , Dosis de Radiación , Adulto , Niño , Europa (Continente) , Humanos , Fantasmas de Imagen , Estudios Prospectivos , Estudios Retrospectivos , Encuestas y Cuestionarios
12.
Eur J Radiol ; 115: 31-38, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31084756

RESUMEN

AIM: The aim of this paper is to present baseline imaging data and the improvement that was achieved by the participating centers after applying practice-specific interventions that were identified during the course of a multicentric multinational research coordinated project. INTRODUCTION: The incidence and mortality rates from breast cancer are rising worldwide and particularly rapidly across the countries with limited resources. Due to lack of awareness and screening options it is usually detected at a later stage. Breast cancer screening programs and even clinical services on breast cancer have been neglected in such countries particularly due to lack of available equipment, funds, organizational structure and quality criteria. MATERIALS AND METHODS: A harmonized form was designed in order to facilitate uniformity of data collection. Baseline data such as type of equipment, number of exams, type and number of biopsy procedures, stage of cancer at detection were collected from 10 centers (9 countries: Bosnia-Herzegovina, Costa Rica, Egypt, India, North Macedonia, Pakistan, Slovenia, Turkey, Uganda) were collected. Local practices were evaluated for good practice and specific interventions such as training of professionals and quality assurance programs were identified. The centers were asked to recapture the data after a 2-year period to identify the impact of the interventions. RESULTS: The data showed increase in the number of training of relevant professionals, positive changes in the mammography practice and image guided interventions. All the centers achieved higher levels of success in the implementation of the quality assurance procedures. CONCLUSION: The study has encountered different levels of breast imaging practice in terms of expertise, financial and human resources, infrastructure and awareness. The most common challenges were the lack of appropriate quality assurance programs and lack of trained skilled personnel and lack of high-quality equipment. The project was able to create higher levels of breast cancer awareness, collaboration amongst participating centers and professionals. It also improved quality, capability and expertise in breast imaging particularly in centers involved diagnostic imaging.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Detección Precoz del Cáncer/normas , Mamografía/normas , Atención a la Salud/normas , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Cooperación Internacional , Garantía de la Calidad de Atención de Salud , Mejoramiento de la Calidad
13.
Phys Med ; 48: 127-134, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29599081

RESUMEN

PURPOSE: The International Atomic Energy Agency (IAEA) through a Coordinated Research Project on "Enhancing Capacity for Early Detection and Diagnosis of Breast Cancer through Imaging", brought together a group of mammography radiologists, medical physicists and radiographers; to investigate current practices and improve procedures for the early detection of breast cancer by strengthening both the clinical and medical physics components. This paper addresses the medical physics component. METHODS: The countries that participated in the CRP were Bosnia and Herzegovina, Costa Rica, Egypt, India, Kenya, the Frmr. Yug. Rep. of Macedonia, Mexico, Nigeria, Pakistan, Philippines, Slovenia, Turkey, Uganda, United Kingdom and Zambia. Ten institutions participated using IAEA quality control protocols in 9 digital and 3 analogue mammography equipment. A spreadsheet for data collection was generated and distributed. Evaluation of image quality was done using TOR MAX and DMAM2 Gold phantoms. RESULTS: QC results for analogue equipment showed satisfactory results. QC tests performed on digital systems showed that improvements needed to be implemented, especially in thickness accuracy, signal difference to noise ratio (SDNR) values for achievable levels, uniformity and modulation transfer function (MTF). Mean glandular dose (MGD) was below international recommended levels for patient radiation protection. Evaluation of image quality by phantoms also indicated the need for improvement. CONCLUSIONS: Common activities facilitated improvement in mammography practice, including training of medical physicists in QC programs and infrastructure was improved and strengthened; networking among medical physicists and radiologists took place and was maintained over time. IAEA QC protocols provided a uniformed approach to QC measurements.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Detección Precoz del Cáncer , Agencias Internacionales , Colaboración Intersectorial , Relación Señal-Ruido
14.
Phys Med ; 48: 55-64, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29728229

RESUMEN

This article aims to present the protocol on Quality Controls in Digital Mammography published online in 2015 by the European Federation of Organisations for Medical Physics (EFOMP) which was developed by a Task Force under the Mammo Working Group. The main objective of this protocol was to define a minimum set of easily implemented quality control tests on digital mammography systems that can be used to assure the performance of a system within a set and acceptable range. Detailed step-by-step instructions have been provided, limiting as much as possible any misinterpretations or variations by the person performing. It is intended that these tests be implemented as part of the daily routine of medical physicists and system users throughout Europe in a harmonised way so allowing results to be compared. In this paper the main characteristics of the protocol are illustrated, including examples, together with a brief summary of the contents of each chapter. Finally, instructions for the download of the full protocol and of the related software tools are provided.


Asunto(s)
Mamografía/normas , Garantía de la Calidad de Atención de Salud/métodos , Sociedades Científicas , Humanos , Mamografía/efectos adversos , Mamografía/instrumentación , Dosis de Radiación , Exposición a la Radiación
15.
Phys Med ; 39: 67-72, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28602688

RESUMEN

The aim of the guideline presented in this article is to unify the test parameters for image quality evaluation and radiation output in all types of cone-beam computed tomography (CBCT) systems. The applications of CBCT spread over dental and interventional radiology, guided surgery and radiotherapy. The chosen tests provide the means to objectively evaluate the performance and monitor the constancy of the imaging chain. Experience from all involved associations has been collected to achieve a consensus that is rigorous and helpful for the practice. The guideline recommends to assess image quality in terms of uniformity, geometrical precision, voxel density values (or Hounsfield units where available), noise, low contrast resolution and spatial resolution measurements. These tests usually require the use of a phantom and evaluation software. Radiation output can be determined with a kerma-area product meter attached to the tube case. Alternatively, a solid state dosimeter attached to the flat panel and a simple geometric relationship can be used to calculate the dose to the isocentre. Summary tables including action levels and recommended frequencies for each test, as well as relevant references, are provided. If the radiation output or image quality deviates from expected values, or exceeds documented action levels for a given system, a more in depth system analysis (using conventional tests) and corrective maintenance work may be required.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Fantasmas de Imagen , Control de Calidad , Programas Informáticos , Guías como Asunto , Humanos , Radiografía Dental , Radiología Intervencionista , Radiocirugia , Informe de Investigación
16.
Eur J Radiol ; 81(9): 2161-8, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21665395

RESUMEN

PURPOSE: The objective is to study mammography practice from an optimisation point of view by assessing the impact of simple and immediately implementable corrective actions on image quality. MATERIALS AND METHODS: This prospective multinational study included 54 mammography units in 17 countries. More than 21,000 mammography images were evaluated using a three-level image quality scoring system. Following initial assessment, appropriate corrective actions were implemented and image quality was re-assessed in 24 units. RESULTS: The fraction of images that were considered acceptable without any remark in the first phase (before the implementation of corrective actions) was 70% and 75% for cranio-caudal and medio-lateral oblique projections, respectively. The main causes for poor image quality before corrective actions were related to film processing, damaged or scratched image receptors, or film-screen combinations that are not spectrally matched, inappropriate radiographic techniques and lack of training. Average glandular dose to a standard breast was 1.5 mGy (mean and range 0.59-3.2 mGy). After optimisation the frequency of poor quality images decreased, but the relative contributions of the various causes remained similar. Image quality improvements following appropriate corrective actions were up to 50 percentage points in some facilities. CONCLUSIONS: Poor image quality is a major source of unnecessary radiation dose to the breast. An increased awareness of good quality mammograms is of particular importance for countries that are moving towards introduction of population-based screening programmes. The study demonstrated how simple and low-cost measures can be a valuable tool in improving of image quality in mammography.


Asunto(s)
Interpretación de Imagen Asistida por Computador/normas , Mamografía/estadística & datos numéricos , Mamografía/normas , Guías de Práctica Clínica como Asunto , Garantía de la Calidad de Atención de Salud/estadística & datos numéricos , Radiometría/estadística & datos numéricos , Radiometría/normas , África , Asia , Europa Oriental , Humanos , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Eur J Radiol ; 79(2): e70-3, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21507590

RESUMEN

The purpose of this work was to investigate status of imaging technology and practice in five countries in Eastern-European region and evaluate the impact of IAEA projects on radiation protection of patients. Information collected using standardized IAEA protocol included status of technology, practices and patient dose levels in interventional procedure, radiography, mammography and computed tomography (CT). In spite of increased number of digital units, single phase generators or units older than 30 year are still in use. Examples of obsolete practice such as using fluoroscopy for positioning, photofluorography, chest fluoroscopy and soft-beam technique for chest radiography are also in use. Modern multi-slice CT or digital mammography units are available; however, there is lack of adequate radiation protection and medical physics support in hospitals. Information on patient doses in interventional procedures, conventional radiography, mammography and CT was collected to have baseline data and corrective measures were proposed with appropriate follow up actions taken.


Asunto(s)
Diagnóstico por Imagen , Control de Calidad , Protección Radiológica/normas , Adulto , Niño , Europa Oriental , Femenino , Fluoroscopía , Humanos , Masculino , Mamografía , Posicionamiento del Paciente , Estudios Prospectivos , Dosis de Radiación , Radiometría/métodos , Encuestas y Cuestionarios , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA