Phys Med Biol ; 54(12): 3755-71, 2009 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-19478373

RESUMEN

A two-dimensional position-sensitive dosimetry system based on a scintillating gas detector is being developed for pre-treatment verification of dose distributions in particle therapy. The dosimetry system consists of a chamber filled with an Ar/CF(4) scintillating gas mixture, inside which two gas electron multiplier (GEM) structures are mounted (Seravalli et al 2008b Med. Phys. Biol. 53 4651-65). Photons emitted by the excited Ar/CF(4) gas molecules during the gas multiplication in the GEM holes are detected by a mirror-lens-CCD camera system. The intensity distribution of the measured light spot is proportional to the 2D dose distribution. In this work, we report on the characterization of the scintillating GEM detector in terms of those properties that are of particular importance in relative dose measurements, e.g. response reproducibility, dose dependence, dose rate dependence, spatial and time response, field size dependence, response uniformity. The experiments were performed in a 150 MeV proton beam. We found that the detector response is very stable for measurements performed in succession (sigma = 0.6%) and its response reproducibility over 2 days is about 5%. The detector response was found to be linear with the dose in the range 0.05-19 Gy. No dose rate effects were observed between 1 and 16 Gy min(-1) at the shallow depth of a water phantom and 2 and 38 Gy min(-1) at the Bragg peak depth. No field size effects were observed in the range 120-3850 mm(2). A signal rise and fall time of 2 micros was recorded and a spatial response of

Asunto(s)
Conteo por Cintilación/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Protones , Reproducibilidad de los Resultados , Conteo por Cintilación/métodos , Sensibilidad y Especificidad
2.
Phys Med Biol ; 53(21): 6195-209, 2008 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-18854612

RESUMEN

A two-dimensional position-sensitive dosimetry system based on a scintillating gas detector is being developed with the aim of using it for pre-treatment verification of dose distributions in charged particle therapy. The dosimetry system consists of a chamber filled with an Ar/CF(4) scintillating gas mixture, inside which two cascaded gas electron multipliers (GEMs) are mounted. A GEM is a thin kapton foil with copper cladding structured with a regular pattern of sub-mm holes. In such a system, light quanta are emitted by the scintillating gas mixture during the electron avalanches in the GEM holes when radiation traverses the detector. The light intensity distribution is proportional to the energy deposited in the detector's sensitive volume by the beam. In the present work, we investigated the optimization of the scintillating GEM detector light yield. The light quanta are detected by means of a CCD camera or a photomultiplier tube coupled to a monochromator. The GEM charge signal is measured simultaneously. We have found that with 60 microm diameter double conical GEM holes, a brighter light signal and a higher electric signal are obtained than with 80 microm diameter holes. With an Ar + 8% CF(4) volume concentration, the highest voltage across the GEMs and the largest light and electric signals were reached. Moreover, we have found that the emission spectrum of Ar/CF(4) is independent of (1) the voltages applied across the GEMs, (2) the x-ray beam intensity and (3) the GEM hole diameter. On the other hand, the ratio of Ar to CF(4) peaks in the spectrum changes when the concentration of the latter gas is varied.


Asunto(s)
Electrones , Gases , Radiometría/instrumentación , Argón , Fluorocarburos , Laboratorios , Dosificación Radioterapéutica , Sensibilidad y Especificidad , Análisis Espectral , Terapia por Rayos X , Rayos X
3.
Phys Med Biol ; 53(17): 4651-65, 2008 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-18695295

RESUMEN

A two-dimensional position sensitive dosimetry system based on a scintillating gas detector has been developed for pre-treatment verification of dose distributions in hadron therapy. The dosimetry system consists of a chamber filled with an Ar/CF4 scintillating gas mixture, inside which two cascaded gas electron multipliers (GEMs) are mounted. A GEM is a thin kapton foil with copper cladding structured with a regular pattern of sub-mm holes. The primary electrons, created in the detector's sensitive volume by the incoming beam, drift in an electric field towards the GEMs and undergo gas multiplication in the GEM holes. During this process, photons are emitted by the excited Ar/CF4 gas molecules and detected by a mirror-lens-CCD camera system. Since the amount of emitted light is proportional to the dose deposited in the sensitive volume of the detector by the incoming beam, the intensity distribution of the measured light spot is proportional to the 2D hadron dose distribution. For a measurement of a 3D dose distribution, the scintillating gas detector is mounted at the beam exit side of a water-bellows phantom, whose thickness can be varied in steps. In this work, the energy dependence of the output signal of the scintillating gas detector has been verified in a 250 MeV/u clinical 12C ion beam by means of a depth-dose curve measurement. The underestimation of the measured signal at the Bragg peak depth is only 9% with respect to an air-filled ionization chamber. This is much smaller than the underestimation found for a scintillating Gd2O2S:Tb ('Lanex') screen under the same measurement conditions (43%). Consequently, the scintillating gas detector is a promising device for verifying dose distributions in high LET beams, for example to check hadron therapy treatment plans which comprise beams with different energies.


Asunto(s)
Carbono , Radiometría/métodos , Procesamiento de Señales Asistido por Computador , Cobre , Diseño de Equipo , Gases , Iones , Luz , Modelos Estadísticos , Fotones , Radiometría/instrumentación , Dosificación Radioterapéutica , Reproducibilidad de los Resultados