Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Opt Lett ; 49(8): 1900-1903, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38621034

RESUMEN

We present a novel, to the best of our knowledge, and straightforward approach for the spatio-spectral characterization of ultrashort pulses. This minimally intrusive method relies on placing a mask with specially arranged pinholes in the beam path before the focusing optic and retrieving the spectrally resolved laser wavefront from the speckle pattern produced at focus. We test the efficacy of this new method by accurately retrieving chromatic aberrations, such as pulse-front tilt (PFT), pulse-front curvature (PFC), and higher-order aberrations introduced by a spherical lens. The simplicity and scalability of this method, combined with its compatibility with single-shot operation, make it a strong complement to existing tools for high-intensity laser facilities.

2.
Phys Med ; 108: 102571, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36989977

RESUMEN

PURPOSE: The Eiger 2X CdTe 1 M-W (Dectris ltd, Baden, Switzerland) single photon counting detector was characterized for imaging applications at the biomedical beamline ID17 of the European Synchrotron Radiation Facility. METHODS: Linearity, Modulation Transfer Function, Noise Power Spectrum and Detective Quantum Efficiency were measured as a function of photon energy and flux in the range 26-80 keV. RESULTS: The linearity was confirmed in the flux range specified by Dectris and a detection efficiency higher than 60 % was measured for energies up to 80 keV. The spatial resolution was inferred from the Modulation Transfer Function and was found to be compatible with the pixel size of the detector (75 µm), except at energies just above the K-edge of Cd and Te where it reached 150 µm. The study of the Noise Power Spectrum showed a time-dependency in the response of the sensor, which is mitigated at low photon fluxes (<2⨯108 ph mm-2 s-1). CONCLUSIONS: This work was the first characterization of the Eiger 2X CdTe 1 M-W for imaging applications with monochromatic synchrotron radiation. The spatial resolution and the quantum efficiency are compatible with low-dose imaging applications.


Asunto(s)
Compuestos de Cadmio , Puntos Cuánticos , Compuestos de Cadmio/química , Telurio/química , Fotones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA