Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ultrasound Obstet Gynecol ; 61(5): 552-558, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36412550

RESUMEN

OBJECTIVE: To evaluate outcomes of dichorionic twin pregnancies undergoing early vs late selective termination of pregnancy (ST). METHODS: MEDLINE, EMBASE, CINAHL and the Web of Science databases were searched electronically up to March 2022. The primary outcome of this study was pregnancy loss prior to 24 weeks' gestation. The secondary outcomes included preterm birth (PTB) before 37, 34, and 32 weeks, preterm prelabor rupture of membranes (PPROM), gestational age (GA) at delivery, Cesarean delivery, mean birth weight, 5-min Apgar score < 7, overall neonatal morbidity and neonatal survival. Only prospective or retrospective studies reporting data on the outcome of early (before 18 weeks) vs late (at or after 18 weeks) ST in dichorionic twin pregnancies were considered suitable for inclusion. Quality assessment of the included studies was performed using the Newcastle-Ottawa scale for cohort studies. Random-effects head-to-head meta-analysis was used to analyze the data. RESULTS: Seven studies reporting on 649 dichorionic twin pregnancies were included in this systematic review. The risk of pregnancy loss prior to 24 weeks was significantly lower in dichorionic twin pregnancies undergoing early compared with late ST (1% vs 8%; odds ratio (OR), 0.25 (95% CI, 0.10-0.65); P = 0.004). The risk of PTB was significantly lower in dichorionic twin pregnancies undergoing early compared with late ST when considering PTB before 37 weeks (19% vs 45%; OR, 0.36 (95% CI, 0.23-0.57); P < 0.00001), before 34 weeks (4% vs 19%; OR, 0.24 (95% CI, 0.11-0.54); P = 0.0005) and before 32 weeks (4% vs 20%; OR, 0.21 (95% CI, 0.05-0.85); P = 0.03). The mean birth weight was significantly greater in the early-ST group (mean difference (MD), 392.2 g (95% CI, 59.1-726.7 g); P = 0.02), as was the mean GA at delivery (MD, 2.47 weeks (95% CI, 0.04-4.91 weeks); P = 0.049). There was no significant difference between dichorionic twin pregnancies undergoing early compared with late ST in terms of PPROM (P = 0.27), Cesarean delivery (P = 0.38), 5-min Apgar score < 7 (P = 0.35) and neonatal survival of the non-reduced twin (P = 0.54). CONCLUSIONS: The risk of pregnancy loss prior to 24 weeks and the rate of PTB before 37, 34 and 32 weeks were significantly higher in dichorionic twin pregnancies undergoing late vs early ST, thus highlighting the importance of early diagnosis of fetal anomalies in twin pregnancies. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Aborto Espontáneo , Nacimiento Prematuro , Embarazo , Femenino , Recién Nacido , Humanos , Embarazo Gemelar , Nacimiento Prematuro/epidemiología , Peso al Nacer , Estudios Retrospectivos , Estudios Prospectivos , Edad Gestacional , Resultado del Embarazo/epidemiología
2.
Ultrasound Obstet Gynecol ; 59(3): 296-303, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34405927

RESUMEN

OBJECTIVE: To evaluate the methodology of studies reporting reference ranges for fetal brain structures on magnetic resonance imaging (MRI). METHODS: MEDLINE, EMBASE, CINAHL and the Web of Science databases were searched electronically up to 31 December 2020 to identify studies investigating biometry and growth of the fetal brain and reporting reference ranges for brain structures using MRI. The primary aim was to evaluate the methodology of these studies. A list of 26 quality criteria divided into three domains, including 'study design', 'statistical and reporting methods' and 'specific aspects relevant to MRI', was developed and applied to evaluate the methodological appropriateness of each of the included studies. The overall quality score of a study, ranging between 0 and 26, was defined as the sum of scores awarded for each quality criterion and expressed as a percentage (the lower the percentage, the higher the risk of bias). RESULTS: Fifteen studies were included in this systematic review. The overall mean quality score of the studies evaluated was 48.7%. When focusing on each domain, the mean quality score was 42.0% for 'study design', 59.4% for 'statistical and reporting methods' and 33.3% for 'specific aspects relevant to MRI'. For the 'study design' domain, sample size calculation and consecutive enrolment of women were the items found to be at the highest risk of bias. For the 'statistical and reporting methods' domain, the presence of regression equations for mean and SD for each measurement, the number of measurements taken for each variable and the presence of postnatal assessment information were the items found to be at the highest risk of bias. For the 'specific aspects relevant to MRI' domain, whole fetal brain assessment was not performed in any of the included studies and was therefore considered to be the item at the highest risk of bias. CONCLUSIONS: Most of the previously published studies reporting fetal brain reference ranges on MRI are highly heterogeneous and have low-to-moderate quality in terms of methodology, which is similar to the findings reported for ultrasound studies. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Espectroscopía de Resonancia Magnética , Embarazo , Valores de Referencia , Ultrasonografía
3.
Ultrasound Obstet Gynecol ; 57(4): 551-559, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33030767

RESUMEN

OBJECTIVE: To report the outcome of fetuses with congenital cytomegalovirus (CMV) infection and normal ultrasound at the time of diagnosis, and to evaluate the rate of an additional anomaly detected only on magnetic resonance imaging (MRI). METHODS: Medline, EMBASE, CINAHL and Cochrane databases were searched for studies reporting on the outcome of fetuses with congenital CMV infection. Inclusion criteria were fetuses with confirmed CMV infection and normal ultrasound assessment at the time of the initial evaluation. The outcomes observed were an anomaly detected on a follow-up ultrasound scan, an anomaly detected on prenatal MRI but missed on ultrasound, an anomaly detected on postnatal assessment but missed prenatally, perinatal mortality, symptomatic infection at birth, neurodevelopmental outcome and hearing and visual deficits. Neurodevelopmental outcome was assessed only in cases of isolated CMV infection confirmed at birth. Subgroup analysis was performed according to the trimester in which maternal infection occurred. Random-effects meta-analysis of proportions was used to analyze the data. RESULTS: Twenty-six studies were included, comprising 2603 fetuses with congenital CMV infection, of which 1178 (45.3%) had normal ultrasound at the time of diagnosis and were included in the analysis. The overall rate of an associated central nervous system (CNS) anomaly detected on a follow-up ultrasound scan was 4.4% (95% CI, 1.4-8.8%) (32/523; 15 studies), while the rates of those detected exclusively on prenatal MRI or on postnatal imaging were 5.8% (95% CI, 1.9-11.5%) (19/357; 11 studies) and 3.2% (95% CI, 0.3-9.0%) (50/660; 17 studies), respectively. The rate of an associated extra-CNS anomaly detected on a follow-up ultrasound scan was 2.9% (95% CI, 0.8-6.3%) (19/523; 15 studies), while the rates of those detected exclusively on MRI or on postnatal imaging were 0% (95% CI, 0.0-1.7%) (0/357; 11 studies) and 0.9% (95% CI, 0.3-1.8%) (4/660; 17 studies), respectively. Intrauterine death and perinatal death each occurred in 0.7% (95% CI, 0.3-1.4%) (2/824; 23 studies) of cases. In cases without an associated anomaly detected pre- or postnatally, symptomatic infection was found in 1.5% (95% CI, 0.7-2.7%) (6/548; 19 studies) of infants, the overall rate of a neurodevelopmental anomaly was 3.1% (95% CI, 1.6-5.1%) (16/550; 19 studies), and hearing problems affected 6.5% (95% CI, 3.8-10.0%) (36/550; 19 studies) of children. Subanalyses according to the trimester in which maternal infection occurred were affected by the very small number of included cases and lack of comparison of the observed outcomes in the original studies. Compared with fetuses infected in the second or third trimester, those infected in the first trimester had a relatively higher risk of having an additional anomaly detected on follow-up ultrasound or MRI, abnormal neurodevelopmental outcome and hearing problems. CONCLUSIONS: In fetuses with congenital CMV infection in which no anomalies are detected on prenatal ultrasound or MRI, the risk of adverse postnatal outcome is lower than that reported previously in the published literature when not considering the role of antenatal imaging assessment. The results from this review also highlight the potential role of MRI, even in fetuses with no anomalies detected on ultrasound, as an anomaly can be detected exclusively on MRI in about 6% of cases. The findings from this study could enhance prenatal counseling of pregnancies with congenital CMV infection with normal prenatal imaging. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Infecciones por Citomegalovirus/embriología , Feto/diagnóstico por imagen , Malformaciones del Sistema Nervioso/diagnóstico por imagen , Complicaciones Infecciosas del Embarazo/diagnóstico por imagen , Diagnóstico Prenatal/métodos , Adulto , Citomegalovirus , Infecciones por Citomegalovirus/congénito , Femenino , Feto/virología , Humanos , Imagen por Resonancia Magnética , Malformaciones del Sistema Nervioso/embriología , Malformaciones del Sistema Nervioso/virología , Embarazo , Complicaciones Infecciosas del Embarazo/virología , Resultado del Embarazo , Ultrasonografía Prenatal
4.
J Biol Regul Homeost Agents ; 35(3 Suppl. 1): 19-28, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34289661

RESUMEN

The purpose of this work was to assess the discomfort perceived by the patient during the intraoral scan procedure using the iTero Scanner. A sample of 33 patients was selected on the basis of parameters that identify a complete dentition. All treated patients underwent a traditional polyvinylsiloxane impression with double procedure and an intraoral scan in the same session. Subsequently they were given a questionnaire concerning the discomfort perceived by both procedures. Once the completed questionnaires were obtained, preliminary statistical tests were carried out to check if the distribution of scores assigned by patients to the two procedures differed significantly from a Gaussian distribution. Furthermore, the discomfort/preference indexes for the two procedures were compared using the Wilcoxon test for paired data. Finally, the Spearman correlation test was used. From the results of the preliminary normality tests, it was decided to use nonparametric type tests that gives the intraoral scan procedure more favorable scores relative to a minor discomfort. The use of intraoral scanning and more specifically of the iTero 2.9 scanner (despite a not small wand), represents an option largely preferred by patients in terms of reduction of discomfort and classic discomfort related to relief systems traditional imprint.


Asunto(s)
Diseño Asistido por Computadora , Procedimientos de Cirugía Plástica , Técnica de Impresión Dental , Humanos , Imagenología Tridimensional , Modelos Dentales , Percepción , Encuestas y Cuestionarios
5.
Clin Radiol ; 76(9): 708.e1-708.e8, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34112509

RESUMEN

Fetal magnetic resonance imaging (MRI) has become a valuable adjunct to ultrasound (US) in diagnosing fetal abnormalities. This review is intended to highlight the contribution of MRI in parental counselling and perinatal treatment. A state-of-the-art fetal MRI protocol with experts of maternal-fetal medicine present in the MRI suite allows emphasis on patient-centred care and maximises therapeutic options.


Asunto(s)
Anomalías Congénitas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Atención Prenatal/métodos , Diagnóstico Prenatal/métodos , Femenino , Humanos , Embarazo
6.
BMC Oral Health ; 21(1): 350, 2021 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-34271907

RESUMEN

BACKGROUND: Bond strength of orthodontic composite is strongly influenced by molecular and structural mechanisms. Aim of this in vitro study was to compare bond strength of light-cure orthodontic composites by measuring debonding forces and evaluating locations of bond failure. Investigations on chemical compositions clarified adhesive behaviors and abilities, exploring effects of ageing processes in this junction materials. METHODS: Twelve enamel discs, from human premolars, were randomly coupled to one orthodontic adhesive system (Transbond XT™ 3 M UNITEK, USA, Light-Cure Orthodontic Paste, LEONE, Italy and Bisco Ortho Bracket Paste LC, BISCO, Illinois) and underwent to Shear Bond Strength test. Metallic brackets were bonded to twenty-seven human premolar, with one of the adhesive systems, to quantify, at FE-SEM magnifications, after debonding, the residual material on enamel and bracket base surfaces. Raman Spectroscopy analysis was performed on eight discs of each composites to investigate on chemical compositions, before and after accelerated aging procedures in human saliva and sugary drink. RESULTS: Orthodontic adhesive systems showed similar strength of adhesion to enamel. The breakage of adhesive-adherent bond occurs in TXT at enamel-adhesive interface while in Bisco and Leone at adhesive-bracket interface. Accelerated in vitro aging demonstrated good physical-chemical stability for all composites, Bisco only, was weakly contaminated with respect to the other materials. CONCLUSION: A similar, clinically adequate and acceptable bond strength to enamel for debonding maneuvers was recorded in all orthodontic adhesive systems under examination. No significant chemical alterations are recorded, even in highly critical situations, not altering the initial mechanical properties of materials.


Asunto(s)
Recubrimiento Dental Adhesivo , Soportes Ortodóncicos , Cementos Dentales , Análisis del Estrés Dental , Humanos , Italia , Ensayo de Materiales , Cementos de Resina , Resistencia al Corte , Estrés Mecánico , Propiedades de Superficie
7.
Ultrasound Obstet Gynecol ; 54(2): 164-171, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30549340

RESUMEN

OBJECTIVES: To report the rate of additional central nervous system (CNS) anomalies detected exclusively on prenatal magnetic resonance imaging (MRI) in fetuses diagnosed with isolated mild or moderate ventriculomegaly (VM) on ultrasound, according to the type of ultrasound protocol adopted (dedicated neurosonography vs standard assessment of the fetal brain), and to explore whether the diagnostic performance of fetal MRI in detecting such anomalies is affected by gestational age at examination and laterality and degree of ventricular dilatation. METHODS: MEDLINE, EMBASE, CINAHL and Clinicaltrials.gov were searched for studies reporting on the prenatal MRI assessment of fetuses diagnosed with isolated mild or moderate VM (ventricular dilatation of 10-15 mm) on ultrasound. Additional anomalies detected only on MRI were classified as callosal, septal, posterior fossa, white matter, intraventricular hemorrhage, cortical, periventricular heterotopia, periventricular cysts or complex malformations. The rate of additional anomalies was compared between fetuses diagnosed on dedicated neurosonography, defined as a detailed assessment of the fetal brain, according to the International Society of Ultrasound in Obstetrics and Gynecology guidelines, and those diagnosed on standard fetal brain assessment. The rate of additional CNS anomalies missed on prenatal MRI and detected only at birth was calculated and compared between fetuses that had early (at or before 24 weeks' gestation) and those that had late (after 24 weeks) MRI. Subanalysis was performed according to the laterality (uni- vs bilateral) and degree (mild vs moderate, defined as ventricular dilatation of 10-12 and 13-15 mm, respectively) of ventricular dilatation. Whether MRI assessment led to a significant change in prenatal management was explored. Random-effects meta-analysis of proportions was used. RESULTS: Sixteen studies (1159 fetuses) were included in the systematic review. Overall, MRI detected an anomaly not identified on ultrasound in 10.0% (95% CI, 6.2-14.5%) of fetuses. However, when stratifying the analysis according to the type of ultrasound assessment, the rate of associated anomalies detected only on MRI was 5.0% (95% CI, 3.0-7.0%) when dedicated neurosonography was performed compared with 16.8% (95% CI, 8.3-27.6%) in cases that underwent a standard assessment of the fetal brain in the axial plane. The overall rate of an additional anomaly detected only at birth and missed on prenatal MRI was 0.9% (95% CI, 0.04-1.5%) (I2 , 0%). There was no difference in the rate of an associated anomaly detected only after birth when fetal MRI was carried out before, compared with after, 24 weeks of gestation (P = 0.265). The risk of detecting an associated CNS abnormality on MRI was higher in fetuses with moderate than in those with mild VM (odds ratio, 8.1 (95% CI, 2.3-29.0); P = 0.001), while there was no difference in those presenting with bilateral, compared with unilateral, dilatation (P = 0.333). Finally, a significant change in perinatal management, mainly termination of pregnancy owing to parental request, following MRI detection of an associated anomaly, was observed in 2.9% (95% CI, 0.01-9.8%) of fetuses undergoing dedicated neurosonography compared with 5.1% (95% CI, 3.2-7.5%) of those having standard assessment. CONCLUSIONS: In fetuses undergoing dedicated neurosonography, the rate of a CNS anomaly detected exclusively on MRI is lower than that reported previously. Early MRI has an excellent diagnostic performance in identifying additional CNS anomalies, although the findings from this review suggest that MRI performed in the third trimester may be associated with a better detection rate for some types of anomaly, such as cortical, white matter and intracranial hemorrhagic anomalies. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Feto/anomalías , Hidrocefalia/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Malformaciones del Sistema Nervioso/diagnóstico por imagen , Aborto Inducido/estadística & datos numéricos , Encéfalo/anomalías , Encéfalo/diagnóstico por imagen , Enfermedades del Sistema Nervioso Central , Cuerpo Calloso/diagnóstico por imagen , Diagnóstico Precoz , Femenino , Feto/diagnóstico por imagen , Edad Gestacional , Humanos , Embarazo , Tercer Trimestre del Embarazo , Diagnóstico Prenatal/métodos , Estudios Retrospectivos , Ultrasonografía Doppler Transcraneal/normas , Ultrasonografía Prenatal/métodos
8.
Prenat Diagn ; 37(13): 1343-1349, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29119613

RESUMEN

PURPOSE: Real-time virtual sonography (RVS) is a new technique that synchronizes real-time ultrasonography (US) and multiplanar reconstructed magnetic resonance imaging (MRI). The purpose of this study was to evaluate the feasibility and ability of RVS to assess the main pathologies in fetuses with suspected US anomalies. METHOD AND MATERIALS: Real-time virtual sonography (Hitachi, HI VISION Ascendus) was offered to 30 patients who had undergone fetal MRI. The acquired MRI image dataset was loaded into the fusion system and displayed together with the real-time US image. The ability of RVS to assess the main anatomical sites and fetal anomalies was evaluated. RESULTS: Real-time virtual sonography was technically possible in all cases. From a total of 30 patients, RVS helped the diagnosis in 10 cases. In 15 cases of encephalic pathology, fusion imaging improved the accuracy of the diagnosis; in the other 5 cases, MRI was superior to US even when using the RVS. CONCLUSION: This is a study on the feasibility and practical use of RVS. Thanks to information from both US and MRI, RVS allowed better identification of the fetal pathologies and improved the performance of the ultrasound examination. In our experience, it was really helpful in pathologies that would benefit from US follow-up.


Asunto(s)
Imagen por Resonancia Magnética , Malformaciones del Sistema Nervioso/diagnóstico por imagen , Neuroimagen/métodos , Ultrasonografía Prenatal/métodos , Estudios de Factibilidad , Femenino , Humanos , Embarazo , Estudios Prospectivos
9.
Childs Nerv Syst ; 30(8): 1445-8, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24566675

RESUMEN

BACKGROUND: The birth prevalence of Apert syndrome is estimated at 1:64,500 and accounts for about 4.5 % of all craniosynostosis with a male/female ratio equal to 1:1. It is associated to allelic mutations in the fibroblast growth factor receptor 2 (FGFR2) gene. Majority cases are sporadic. Prenatal ultrasound diagnosis is based on the detection of abnormal cranial shape, midfacial hypoplasia and bilateral syndactyly of hands and feet, hypertelorism, and exorbitism. Other abnormalities includes central nervous system anomalies, congenital heart diseases, cleft palate, and urogenital diseases. CASE REPORT: A 37-year-old Caucasian woman, gravida 2, para 1, was referred to our center of Prenatal Diagnosis for routine ultrasound at 21 weeks of gestation. We detected irregular head shape, dolicocephaly, prominent forehead, bilateral mild ventriculomegaly, suspicion of partial agenesis of the corpus callosum, hypertelorism, and midfacial hypoplasia, with a depressed nasal bridge and syndactyly, prompting a suspicion for Apert syndrome. Magnetic resonance excluded agenesis of corpus callosum and confirmed bilateral mild ventriculomegaly. A follow-up ultrasound, performed at 23 weeks, confirmed the anomalies showed in the previous scan. An amniocentesis was performed. The results showed a normal male karyotype, while the molecular genetic test confirmed a mutation in FGFR2 gene. Fetus macroscopic analysis showed compatible features. CONCLUSIONS: Our case underlines the complementary role of ultrasound and magnetic resonance imaging in the early prenatal diagnosis of Apert syndrome.


Asunto(s)
Acrocefalosindactilia/diagnóstico por imagen , Acrocefalosindactilia/patología , Diagnóstico Prenatal/métodos , Adulto , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Ultrasonografía Doppler
10.
Clin Exp Obstet Gynecol ; 41(5): 581-2, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25864265

RESUMEN

The X6-1 xmatrix array transducer allows a completely new approach to the diagnostic ultrasound: it permits visualization of fetal heart in real time, without the need for gating, and it is unaffected by motion artefacts. It is obtained in real time, without any spatial reconstruction. The authors compared this technology with the traditional one in two case reports: a diagnostic doubt of small muscular ventricular septal defect was solved using this new technique; a diagnosis of complete atrioventricular septal defect was confirmed. Three-dimensional real-time imaging would seem very precise in the study of fetal heart: the defects were fully visualized from any angulations. This new technology is promising but from the authors' limited experience, there is no evidence to use it in routine practice. It should be very useful to commence a prospective study on fetuses at risk while testing the superiority of this technique.


Asunto(s)
Ecocardiografía Tridimensional/instrumentación , Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Transductores , Ultrasonografía Prenatal/instrumentación , Adulto , Diagnóstico Diferencial , Diseño de Equipo , Femenino , Cardiopatías Congénitas/embriología , Humanos , Masculino , Embarazo
11.
Clin Exp Obstet Gynecol ; 41(5): 599-600, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25864271

RESUMEN

The only prostaglandin analogue licensed in Italy for induction of labour in spontaneous and therapeutic abortion is gemeprost. The authors report a case of spontaneous uterine rupture of a scarred uterus, for previous caesarean sections, in a woman at 20 weeks of gestation with a diagnosis of spontaneous abortion. She received a pessary of gemeprost every three hours. After the fifth pessary, she complained of severe pain. At the ultrasound examination, uterine cavity appeared empty and the dead fetus was dislocated in the abdomen. Emergency laparotomy was performed and uterine tear was repaired. To induce labour for fetal demise or therapeutic abortion in second trimester in women with scarred uterus, the authors decided to lengthen the time between administrations of pessary from four to five hours depending on patient's symptoms. However the appropriate drug regimen has still to be found and more data are necessary.


Asunto(s)
Aborto Espontáneo , Alprostadil/análogos & derivados , Trabajo de Parto Inducido/efectos adversos , Rotura Uterina/inducido químicamente , Abortivos no Esteroideos/administración & dosificación , Abortivos no Esteroideos/efectos adversos , Administración Intravaginal , Adulto , Alprostadil/administración & dosificación , Alprostadil/efectos adversos , Femenino , Muerte Fetal , Humanos , Masculino , Embarazo , Segundo Trimestre del Embarazo , Prostaglandinas E Sintéticas , Ultrasonografía Prenatal , Rotura Uterina/diagnóstico
12.
J Obstet Gynaecol ; 33(7): 675-7, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24127951

RESUMEN

The rate of multiple pregnancies is showing a significant increase in Western countries. Twin gestations should be considered a high-risk condition because they are responsible for a disproportionate amount of overall perinatal morbidity and mortality. We used a specialised ultrasound protocol based on chorionicity to monitor 44 twin pregnancies (61% dichorionic diamniotic (DD) and 39% monochorionic diamniotic (MD)). Adverse pregnancy outcomes and pre-term deliveries were more common in MD pregnancies than in DD pregnancies; the rate of extreme pre-term delivery (< 32 weeks) was almost three-times higher in MD than in DD pregnancies (41% vs 15%) and perinatal complications were more frequent in MD than in DD pregnancies (59% vs 22%), but fetal anomalies were more frequent in DD than in MD pregnancies (30% vs 24%). Periodic ultrasound follow-up would predict the pregnancies that are at greater risk for fetal and neonatal complications and these should be monitored more closely.


Asunto(s)
Embarazo Gemelar , Ultrasonografía Prenatal , Adulto , Femenino , Humanos , Embarazo , Resultado del Embarazo , Embarazo Gemelar/estadística & datos numéricos , Estudios Retrospectivos
13.
Eur J Paediatr Dent ; 24(3): 241-246, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37668457

RESUMEN

BACKGROUND: Proper development of deciduous and mixed dentition is essential to the oral health of growing patients, and early interceptive orthopedic or orthodontic treatments are indicated in specific clinical situations. Nowadays, orthodontists are subjected to a lot of pressure from growing patients and their parents about the orthodontic appliances that should be used. The aim of this article is to indicate how, when and why it is possible to effectively use aligners in growing patients. CASE REPORT: Two case reports are illustrated, one with a Cl.II subdivision, mono lateral cross-bite and vertical growth, and the other with a skeletal and dental Cl.II, vertical skeletal pattern, proclined and fractured upper incisors. The efficacy/efficiency ratio of aligners is analyzed in order to evaluate the suitability of this appliance for the treatment. Limits and advantages of aligners are widely discussed. CONCLUSION: Aligner treatment in growing patients shall be carefully studied to reach an optimal result. At present, a hybrid treatment strategy represents the best solution in growing patients with a complex clinical situation.


Asunto(s)
Atención Odontológica , Dentición Mixta , Humanos , Incisivo , Salud Bucal , Aparatos Ortodóncicos
14.
Acta Trop ; 248: 107037, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37805040

RESUMEN

Data on cellular immunity mediators in the early phase of human leishmaniasis are still limited and controversial. In order to mimic the changes of humoral mediators during the early phase of human natural infection, some Th1, Th2, Treg, and Breg cytokines, MCP-1, and the nitric oxide (NO) from human PBMC, stimulated by Leishmania infantum, Leishmania major, Leishmania donovani and Leishmania tropica infective metacyclic promastigotes, were determined. After 4 h of L. major, L. donovani, and L. tropica challenge, TNFα, IL-1ß, IL-6 levels were significantly higher than negative control cultures with saline (SF) instead of Leishmania promastigotes, unlike L. infantum-stimulated TNFα and L. major-stimulated IL-1ß. We obtained higher levels of IL-4 and IL-10 cytokines after stimulation of human PBMCs by L. infantum and L. donovani, compared to those observed after the challenge of PBMCs by L. major and L. tropica. Regarding IL-35, such cytokine levels were significantly increased following infection with L. infantum and L. donovani, in contrast to L. major and L. tropica. Up to our knowledge, we are the first to study the effect of four different species of Leishmania on IL-35 levels in human cells. Our study highlights how several Leishmania species can up-regulate different groups of cytokines (Th1, Th2, Treg and Breg) and modulate NO release in a different way. This original aspect can be explained by different Leishmania cell products, such as LPG, obtained from different strains/species of live parasites. Our findings would contribute to the development of new therapeutics or vaccination strategies.


Asunto(s)
Leishmania donovani , Leishmania infantum , Leishmaniasis Visceral , Leishmaniasis , Parásitos , Animales , Humanos , Factor de Necrosis Tumoral alfa , Leucocitos Mononucleares , Leishmaniasis/parasitología , Citocinas , Interleucinas , Progresión de la Enfermedad
15.
Infection ; 40(3): 299-302, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22173948

RESUMEN

PURPOSE: Universal anti-hepatitis B vaccination of infants and of 12-year-old children became mandatory in Italy in 1991. The purpose of this study was to evaluate the persistence of anti-hepatitis B surface (HBs) antibodies several years after a primary course of vaccination. METHODS: In 2010, anti-HBs titers were measured in all subjects aged between 5 and 25 years residing in a southern Italian town. Individuals with an anti-hepatitis B antibody concentration of 10 IU/ml or more were considered to be protected. RESULTS: Of the 671 subjects evaluated, 149 (30%) lacked protective antibodies. Fifty-three (29.4%) of the subjects had been vaccinated ≤10 years earlier and 96 (30.3%) more than 10 years earlier (P = not significant). Subjects vaccinated in infancy were more likely to lack protective anti-HBs antibodies than subjects vaccinated at 12 years of age, regardless of the years elapsed since immunization. CONCLUSIONS: Most subjects maintained protective antibodies for a considerable number of years after vaccination. Vaccination in adolescence results in more prolonged immunogenicity than vaccination in infancy.


Asunto(s)
Anticuerpos contra la Hepatitis B/sangre , Vacunas contra Hepatitis B/inmunología , Hepatitis B/inmunología , Adolescente , Adulto , Niño , Preescolar , Ensayo de Inmunoadsorción Enzimática , Femenino , Hepatitis B/prevención & control , Antígenos del Núcleo de la Hepatitis B/sangre , Antígenos del Núcleo de la Hepatitis B/inmunología , Antígenos de Superficie de la Hepatitis B/sangre , Antígenos de Superficie de la Hepatitis B/inmunología , Vacunas contra Hepatitis B/administración & dosificación , Virus de la Hepatitis B/aislamiento & purificación , Humanos , Italia , Masculino , Factores de Tiempo , Adulto Joven
16.
Clin Exp Obstet Gynecol ; 39(3): 384-7, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23157052

RESUMEN

Fetal mediastinal masses are rare congenital formations that could complicate pregnancy. They are usually discovered as space occupying lesions in the fetal chest during routine ultrasound scan. The most important prognostic factors of mediastinal masses are mass location, compressing effect causing pulmonary hypoplasia and/or heart failure, and the presence or absence of hydrops. We report a case of fetal mediastinal teratoma and a review of the literature. A 32-year-old woman carrying a fetus with hydrops due to a mediastinal mass underwent cesarean section at 32 1/7 weeks' gestation. A well encapsulated tumor was excised by surgery at one day of life. The baby is now eight months old without respiratory difficulty. To our knowledge, this is the fourth case report of a mediastinal teratoma associated with nonimmune hydrops in a fetus that survived the neonatal period. Fetal mediastinal teratoma requires close surveillance and multidisciplinary management by obstetricians, neonatologists, and pediatric surgeons.


Asunto(s)
Enfermedades Fetales/diagnóstico , Neoplasias del Mediastino/diagnóstico , Neoplasias del Mediastino/embriología , Teratoma/diagnóstico , Teratoma/embriología , Adulto , Cesárea , Femenino , Edad Gestacional , Humanos , Hidropesía Fetal/diagnóstico , Recién Nacido , Masculino , Neoplasias del Mediastino/cirugía , Embarazo , Pronóstico , Teratoma/cirugía
17.
Eur J Paediatr Dent ; 12(1): 60-2, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21434738

RESUMEN

AIM: The objective of this paper is to show an alternative use of an Essix based appliance in the treatment of anterior single-tooth crossbite malocclusion in a patient with Nickel allergy. MATERIALS AND METHODS: Anterior crossbite malocclusion of one or more teeth, without posterior crossbite association, is a relatively frequent condition both in the mixed and the permanent dentition. This kind of malocclusion is usually treated with either fixed or removable appliances. The use of preformed Essix appliances could be an alternative to traditional removable and fixed orthodontic devices in patients with Nickel allergy as well as in every patient. RESULTS: The treatment was successfully completed in 12 weeks, the anterior single tooth crossbite was corrected using three full arch Essix-based appliances planned on the set-up casting, providing a gradual vestibular movement. Patient compliance was requested in order to provide the planned dental movement. CONCLUSION: The Essix appliance can be successfully used to correct a single-tooth crossbite even in allergic subjects in a short time with patient cooperation.


Asunto(s)
Hipersensibilidad/complicaciones , Maloclusión/terapia , Níquel/efectos adversos , Diseño de Aparato Ortodóncico , Aparatos Ortodóncicos Removibles , Ortodoncia Correctiva/instrumentación , Niño , Contraindicaciones , Humanos , Masculino , Maloclusión/complicaciones , Soportes Ortodóncicos , Retenedores Ortodóncicos , Alambres para Ortodoncia , Planificación de Atención al Paciente
18.
Diagn Microbiol Infect Dis ; 101(2): 115485, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34365091

RESUMEN

Antimicrobial Susceptibility Testing is mandatory for Bloodstream Infections management in order to establish appropriate antimicrobial therapy. Herein we evaluated new approach based on AST results directly from positive blood cultures, using Microscan WA to carry out rapid phenotypical profile of antibiotic resistance. Our investigations allow to reduce time versus traditional results.


Asunto(s)
Antibacterianos/farmacología , Bacteriemia/microbiología , Bacterias/efectos de los fármacos , Farmacorresistencia Bacteriana , Cultivo de Sangre , Diagnóstico Precoz , Humanos , Fenotipo , Factores de Tiempo
19.
Minerva Ginecol ; 62(6): 551-8, 2010 Dec.
Artículo en Italiano | MEDLINE | ID: mdl-21413168

RESUMEN

AIM: Systematic lupus erythematosus (SLE) is the most common autoimmune disease associated with pregnancy. The aim of this study was to evaluate management and outcome of pregnancy complicated by SLE. METHODS: Twenty pregnant women affected by SLE were admitted to Prenatal Diagnosis Centre of University "Sapienza" from January 2007 to July 2009. Pregnancy was monitored from diagnosis to delivery by at least a monthly consultation. At each visit general blood laboratory assessment were registered. An ultrasound examination was performed to evaluate fetal growth. From 26 weeks of gestation an estimation of fetal weight was calculated according to the standard of Lubchenco. At birth newborns weight was registered. RESULTS: Patient mean age was 32.9 years. There were 18 live births (90%), and 2 spontaneous abortions; 50% of pregnancy ended with a preterm delivery. 20% of the patient had signs of disease activity during pregnancy. Fifteen percent of women presented gestational hypertension. An high rate of small for gestational age was registered and 2 cases of intrauterine growth retardation (IUGR). Ultrasound evaluation at 28-30 weeks of gestation showed a normal weight (≥ 50th percentile) in 83% fetuses. Only 45% of the newborns presented ≥ 50th percentile. The mean weight of the newborns was 2700 grams. CONCLUSION: Pregnancy outcome could be improved by close obstetrical and ultrasound monitoring in a multidisciplinary setting.


Asunto(s)
Lupus Eritematoso Sistémico/epidemiología , Complicaciones del Embarazo/epidemiología , Aborto Espontáneo/epidemiología , Adulto , Femenino , Humanos , Hipertensión Inducida en el Embarazo/epidemiología , Recién Nacido , Recien Nacido Prematuro , Italia/epidemiología , Lupus Eritematoso Sistémico/complicaciones , Lupus Eritematoso Sistémico/diagnóstico , Lupus Eritematoso Sistémico/inmunología , Lupus Eritematoso Sistémico/terapia , Embarazo , Complicaciones del Embarazo/diagnóstico , Complicaciones del Embarazo/inmunología , Complicaciones del Embarazo/terapia , Resultado del Embarazo , Nacimiento Prematuro/epidemiología , Estudios Retrospectivos , Factores de Riesgo
20.
Case Rep Dent ; 2020: 8861653, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33194233

RESUMEN

INTRODUCTION: The concept of orthodontic retention is moving toward the idea that teeth will move unless retained indefinitely. However, permanent retention implies permanent supervision, and that is where reality clashes with stability. The cornerstone of Essix permanent retention is the complete delegation of responsibility to the patient. Essix retainers have nothing to adjust, but maximum collaboration of the patient is essential to achieve long-term stability. The purpose of this paper is to show the effectiveness of the thermoplastic appliance as a retainer, using a clinical case with a 10-year follow-up. Case Report. A 33-year-old male patient presented with a class II malocclusion division 2 and normal skeletal pattern. According to the patient's desire, a treatment plan was proposed to obtain the aesthetic result of the smile, maintaining the molar and canine class II relationship. The orthodontic therapy was performed by using the Invisalign System. In this case, it was possible to appreciate a posterior occlusal stability after 10 years. CONCLUSION: Currently, among orthodontists, the use of removable plastic devices is gaining popularity thanks to their capability to encapsulate and retain both posterior and anterior teeth. In this article, the technical features of thermoformed retainers will be described and one clinical case with a 10-year follow-up will be presented to emphasize the effectiveness of these retainers.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA