Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Ann Vasc Surg ; 61: 468.e1-468.e3, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31376543

RESUMEN

We treated a 73-year-old female patient with a giant thoracic proximal aortic aneurysm above a previous multibranched thoracoabdominal graft without a distal neck for a standard endovascular approach. A procedure with sandwich technique was performed using the new Valiant Navion Evo Thoracic Endograft® to preserve visceral graft. Postoperative angio-computed tomography scan demonstrated the correct position of the endoprosthesis without any leakage with patency of visceral graft.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Diseño de Prótesis , Resultado del Tratamiento
2.
Ann Vasc Surg ; 57: 272.e15-272.e17, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30684606

RESUMEN

We treated an 89-year-old patient affected by a descending thoracic aorta lesion due to a rib fracture with a penetrating costal stump. An urgent combined thoracic and endovascular surgical approach was performed, removing the rib fragment and positioning an aortic endoprosthesis simultaneously. Postoperative angio-computed tomography scan demonstrated the correct position of the endoprosthesis without any leakage or periaortic hemorrhage.


Asunto(s)
Aorta Torácica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Fracturas de las Costillas/etiología , Lesiones del Sistema Vascular/cirugía , Heridas no Penetrantes/cirugía , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/lesiones , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Fracturas de las Costillas/diagnóstico por imagen , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Heridas no Penetrantes/diagnóstico por imagen , Heridas no Penetrantes/etiología
3.
Thorac Cardiovasc Surg ; 63(4): 292-7, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25361016

RESUMEN

BACKGROUND: Saphenous vein conduits are still used in a large proportion of coronary artery bypass graft (CABG) operations. A recently commercialized nitinol mesh seems to improve venous graft patency. The aim of this study was to control nitinol mesh vein graft patency in a series of isolated CABG patients by computed tomographic (CT) scan. METHODS: In 25 patients (mean age: 61.0 ± 9.65 years), operated for isolated CABG, the eSVS nitinol mesh (Kips Bay Medical Inc., Minneapolis, Minnesota, United States) was used to wrap one vein graft in each patient. Nitinol mesh vein graft was used to revascularize the right coronary (4 patients; 16%), the posterior descending (18 patients; 72%), and the obtuse marginal (3 patients; 12%) arteries. CT scans were performed at 1, 6, and 12 months postoperatively. RESULTS: The procedure was uneventful in all patients. CT controls showed an overall patency rate of 86.9, 42.7, and 34.1% at 1, 6, and 12 months, respectively. The 4 mm mesh had a significantly higher patency rate at 12 months (83.33%) than the 3.5 mm one which showed quite unsatisfactory results (20%) (p = 0.02). Patients with graft occlusion underwent stress testing which was mildly positive in two cases. One of them underwent a percutaneous revascularization. CONCLUSION: Despite promising early results, use of nitinol mesh for saphenous veins was disappointing in our experience. Further refinements are probably needed.


Asunto(s)
Aleaciones , Puente de Arteria Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/cirugía , Vena Safena/trasplante , Mallas Quirúrgicas , Anciano , Angiografía Coronaria/métodos , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Diseño de Equipo , Femenino , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Vena Safena/diagnóstico por imagen , Vena Safena/fisiopatología , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA