Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Acta Radiol ; 64(2): 605-611, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35147046

RESUMEN

BACKGROUND: In muscular dystrophies, it is not only skeletal muscles that can be affected, but also the myocardium. This cardiac involvement can represent a major cause of morbidity and mortality. PURPOSE: To investigate cardiac involvement in Duchenne (DMD), Becker (BMD), and limb girdle muscular dystrophy (LGMD) patients, and carriers of DMD/BMD by cardiac magnetic resonance (CMR) imaging and to search for differences in the pattern of cardiac involvement. MATERIAL AND METHODS: All patients with genetically or histologically proven DMD, BMD, and LGMD, or confirmed carriers of DMD/BMD who had undergone CMR at our clinic between January 2008 and November 2018 were retrospectively included and re-evaluated for regional and global left ventricular function, increased trabecularization, and late enhancement. RESULTS: A total of 26 DMD, 10 BMD, 11 LGMD, and seven DMD/BMD carriers were included. Only one carrier of DMD presented with normal CMR results; all other participants showed cardiac abnormalities. Regional wall motion abnormalities (RWMA; prevalence in LGMD patients: 55%) and late enhancement (prevalence in LGMD patients: 82%) were frequent. RWMA were accentuated basal inferolateral in DMD/BMD carriers, while in LGMD they were accentuated apical. In all groups late enhancement was located mainly subepicardial/midmyocardial with a basal inferolateral accentuation. Apart from the different RWMA distribution, no further group-specific differences were found. CONCLUSION: We found a high rate of cardiac involvement not only in DMD/BMD, but also in LGMD and DMD/BMD carriers with a different RWMA accentuation (apical in LGMD and basal inferolateral in DMD/BMD) as a single group-specific difference.


Asunto(s)
Distrofia Muscular de Duchenne , Humanos , Distrofia Muscular de Duchenne/diagnóstico por imagen , Distrofia Muscular de Duchenne/patología , Estudios Retrospectivos , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/patología , Corazón , Imagen por Resonancia Magnética
2.
J Nucl Cardiol ; 25(3): 785-794, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-27638745

RESUMEN

OBJECTIVE: Besides cardiac sarcoidosis, FDG-PET is rarely used in the diagnosis of myocardial inflammation, while cardiac MRI (CMR) is the actual imaging reference for the workup of myocarditis. Using integrated PET/MRI in patients with suspected myocarditis, we prospectively compared FDG-PET to CMR and the feasibility of integrated FDG-PET/MRI in myocarditis. METHODS: A total of 65 consecutive patients with suspected myocarditis were prospectively assessed using integrated cardiac FDG-PET/MRI. Studies comprised T2-weighted imaging, late gadolinium enhancement (LGE), and simultaneous PET acquisition. Physiological glucose uptake in the myocardium was suppressed using dietary preparation. RESULTS: FDG-PET/MRI was successful in 55 of 65 enrolled patients: two patients were excluded due to claustrophobia and eight patients due to failed inhibition of myocardial glucose uptake. Compared with CMR (LGE and/or T2), sensitivity and specificity of PET was 74% and 97%. Overall spatial agreement between PET and CMR was κ = 0.73. Spatial agreement between PET and T2 (κ = 0.75) was higher than agreement between PET and LGE (κ = 0.64) as well as between LGE and T2 (κ = 0.56). CONCLUSION: In patients with suspected myocarditis, FDG-PET is in good agreement with CMR findings.


Asunto(s)
Fluorodesoxiglucosa F18 , Miocarditis/diagnóstico por imagen , Tomografía de Emisión de Positrones , Radiofármacos , Adulto , Medios de Contraste , Estudios de Factibilidad , Femenino , Gadolinio , Humanos , Imagen por Resonancia Magnética , Masculino , Imagen Multimodal , Estudios Prospectivos
3.
Neuroradiology ; 60(12): 1267-1272, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30219935

RESUMEN

PURPOSE: Computer-aided diagnosis (CAD) appears promising in early ischemic change detection computed tomography (CT). This study aimed to compare the performance of two new CAD systems (Frontier ASPECTS Prototype and Brainomix) with two experienced readers in selected patients with suspected acute ischemic stroke. METHODS: Retrospectively, non-contrast brain CTs of 150 patients suspected for acute middle cerebral artery ischemia were analyzed with respect to ASPECTS first separately, than in consensus by two senior radiologists, and by use of Frontier and Brainomix. Besides the fully automatic Frontier and Brainomix readings (Frontier_1, Brainomix_1), readings adjusted for the affected brain side (known by CT angiography or clinical presentation, Frontier_2, Brainomix_2) were assessed. Statistical analysis was performed by intraclass correlation and Bland-Altman statistics. RESULTS: The score-based ASPECTS readings of Brainomix_1, Brainomix_2, both radiologists, and the expert consensus reading correlated highly (r = 0.714 to 0.841; always p < 0.001), whereas Frontier_1 and Frontier_2 correlated only lowly or moderately with both radiologists, the expert consensus reading, and Brainomix (r = 0.471 to 0.680; always p < 0.001). Bland-Altman analysis revealed lower mean ASPECT difference and standard deviation of difference for Brainomix_2 (mean difference = -0.2; SD = 1.15) compared to Frontier_2 (mean difference = 1.2; SD = 1.76). Correlation of region-based ASPECTS reading with the expert consensus reading was moderate for Brainomix_2 (r = 0.534), but only low for Frontier_2 (r = 0283; always p < 0.001). CONCLUSION: We found high agreement in ASPECTS rating between both radiologists, expert consensus reading, and Brainomix, but only low to moderate agreement to Frontier.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Diagnóstico por Computador/instrumentación , Aumento de la Imagen/instrumentación , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Reconocimiento de Normas Patrones Automatizadas , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/instrumentación , Anciano , Anciano de 80 o más Años , Diagnóstico Precoz , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Programas Informáticos
4.
Acta Radiol ; 58(8): 922-928, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28273733

RESUMEN

Background Cardiac magnetic resonance imaging (MRI) relies on correct ECG-gating, which is hindered in arrhythmia. Purpose To examine whether a prototype free-breathing real-time cine sequence using SPARSE-SENSE (SPARSE) improves left ventricular quantification in atrial fibrillation. Material and Methods On a 1.5T MR system left ventricular short-axis stacks were acquired of the SPARSE sequence and of a "reference" steady-state free precession (SSFP) sequence with arrhythmia rejection in 20 patients with atrial fibrillation. Two radiologists independently rated arrhythmia-caused artifact severity in both sequences using a 4-point scale. Coefficients of variation of myocardial signal intensity for both sequences were acquired. Volumetry was performed twice by one reader and once by another reader. Correlation between artifact severity and employed sequence was analyzed by modified Fisher's exact test. Coefficients of variation and volumetric data were compared by paired t-test and intraclass correlation. Results Median arrhythmia-caused artifact severity was 2 in both readers for SSFP and 0 (reader 1)/1 (reader 2) for SPARSE, being significantly lower in SPARSE ( P < 0.001). Mean coefficient of variance was significantly smaller in SPARSE (0.11 ± 0.04) compared to SSFP (0.22 ± 0.13, P = 0.003), which was interpreted as a hint for fewer artifacts in SPARSE. Only a small difference of 9 ± 15 mL was seen for end-systolic volume ( P = 0.019) between sequences, otherwise no significant difference was detected (end-diastolic volume, P = 0.200; stroke volume, P = 0.554; ejection fraction, P = 0.136; myocardial mass, P = 0.353). Intraclass correlation between sequences was good to excellent (range, 0.80-0.97). Conclusion Real-time MRI with SPARSE data sampling is promising in atrial fibrillation because it reduces arrhythmia-caused artifacts.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Anciano , Anciano de 80 o más Años , Algoritmos , Artefactos , Estudios de Factibilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Estudios Prospectivos
5.
J Magn Reson Imaging ; 44(2): 366-74, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26789014

RESUMEN

PURPOSE: To assess two compressed sensing cine magnetic resonance imaging (MRI) sequences with high spatial or high temporal resolution in comparison to a reference steady-state free precession cine (SSFP) sequence for reliable quantification of left ventricular (LV) volumes. MATERIALS AND METHODS: LV short axis stacks of two compressed sensing breath-hold cine sequences with high spatial resolution (SPARSE-SENSE HS: temporal resolution: 40 msec, in-plane resolution: 1.0 × 1.0 mm(2) ) and high temporal resolution (SPARSE-SENSE HT: temporal resolution: 11 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) and of a reference cine SSFP sequence (standard SSFP: temporal resolution: 40 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) were acquired in 16 healthy volunteers on a 1.5T MR system. LV parameters were analyzed semiautomatically twice by one reader and once by a second reader. The volumetric agreement between sequences was analyzed using paired t-test, Bland-Altman plots, and Passing-Bablock regression. RESULTS: Small differences were observed between standard SSFP and SPARSE-SENSE HS for stroke volume (SV; -7 ± 11 ml; P = 0.024), ejection fraction (EF; -2 ± 3%; P = 0.019), and myocardial mass (9 ± 9 g; P = 0.001), but not for end-diastolic volume (EDV; P = 0.079) and end-systolic volume (ESV; P = 0.266). No significant differences were observed between standard SSFP and SPARSE-SENSE HT regarding EDV (P = 0.956), SV (P = 0.088), and EF (P = 0.103), but for ESV (3 ± 5 ml; P = 0.039) and myocardial mass (8 ± 10 ml; P = 0.007). Bland-Altman analysis showed good agreement between the sequences (maximum bias ≤ -8%). CONCLUSION: Two compressed sensing cine sequences, one with high spatial resolution and one with high temporal resolution, showed good agreement with standard SSFP for LV volume assessment. J. Magn. Reson. Imaging 2016;44:366-374.


Asunto(s)
Algoritmos , Compresión de Datos/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Aumento de la Imagen/métodos , Imagen por Resonancia Cinemagnética/métodos , Volumen Sistólico , Adulto , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Eur Radiol ; 26(11): 3923-3931, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26873493

RESUMEN

OBJECTIVES: To investigate the influence of intravenous gadolinium on cartilage T2 and T2* relaxation times and on morphological image quality at 7-T hip MRI. METHODS: Hips of 11 healthy volunteers were examined at 7 T. Multi-echo sequences for T2 and T2* mapping, 3D T1 volumetric interpolated breath-hold examination (VIBE) and double-echo steady-state (DESS) sequences were acquired before and after intravenous application of gadolinium according to a delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) protocol. Cartilage relaxation times were measured in both scans. Morphological sequences were assessed quantitatively using contrast ratios and qualitatively using a 4-point Likert scale. Student's t-test, Pearson's correlation (ρ) and Wilcoxon sign-rank test were used for statistical comparisons. RESULTS: Pre- and post-contrast T2 and T2* values were highly correlated (T2: acetabular: ρ = 0.76, femoral: ρ = 0.77; T2*: acetabular: ρ = 0.80, femoral: ρ = 0.72). Gadolinium enhanced contrasts between cartilage and joint fluid in DESS and T1 VIBE according to the qualitative (p = 0.01) and quantitative (p < 0.001) analysis. The delineation of acetabular and femoral cartilage and the labrum predominantly improved with gadolinium. CONCLUSIONS: Gadolinium showed no relevant influence on T2 or T2* relaxation times and improved morphological image quality at 7 T. Therefore, morphological and quantitative sequences including dGEMRIC can be conducted in a one-stop-shop examination. KEY POINTS: • Hip cartilage T2 values correlate highly before and after gadolinium at 7 T • Hip cartilage T2* values correlate highly before and after enhancement at 7 T • Morphological hip cartilage imaging benefits from intravenous gadolinium at 7 T • The delineation of acetabular and femoral cartilage can be improved by gadolinium • Morphological and quantitative sequences including dGEMRIC can be combined as a one-stop-shop examination.


Asunto(s)
Cartílago Articular/anatomía & histología , Medios de Contraste/administración & dosificación , Gadolinio DTPA/administración & dosificación , Acetábulo/anatomía & histología , Administración Intravenosa , Adulto , Cartílago Articular/efectos de los fármacos , Femenino , Voluntarios Sanos , Articulación de la Cadera/anatomía & histología , Humanos , Imagen por Resonancia Magnética/métodos , Masculino
7.
Eur Radiol ; 26(12): 4482-4489, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26960537

RESUMEN

OBJECTIVES: Improved real-time cardiac magnetic resonance (CMR) sequences have currently been introduced, but so far only limited practical experience exists. This study aimed at image reconstruction optimization and clinical validation of a new highly accelerated real-time cine SPARSE-SENSE sequence. METHODS: Left ventricular (LV) short-axis stacks of a real-time free-breathing SPARSE-SENSE sequence with high spatiotemporal resolution and of a standard segmented cine SSFP sequence were acquired at 1.5 T in 11 volunteers and 15 patients. To determine the optimal iterations, all volunteers' SPARSE-SENSE images were reconstructed using 10-200 iterations, and contrast ratios, image entropies, and reconstruction times were assessed. Subsequently, the patients' SPARSE-SENSE images were reconstructed with the clinically optimal iterations. LV volumetric values were evaluated and compared between both sequences. RESULTS: Sufficient image quality and acceptable reconstruction times were achieved when using 80 iterations. Bland-Altman plots and Passing-Bablok regression showed good agreement for all volumetric parameters. CONCLUSIONS: 80 iterations are recommended for iterative SPARSE-SENSE image reconstruction in clinical routine. Real-time cine SPARSE-SENSE yielded comparable volumetric results as the current standard SSFP sequence. Due to its intrinsic low image acquisition times, real-time cine SPARSE-SENSE imaging with iterative image reconstruction seems to be an attractive alternative for LV function analysis. KEY POINTS: • A highly accelerated real-time CMR sequence using SPARSE-SENSE was evaluated. • SPARSE-SENSE allows free breathing in real-time cardiac cine imaging. • For clinically optimal SPARSE-SENSE image reconstruction, 80 iterations are recommended. • Real-time SPARSE-SENSE imaging yielded comparable volumetric results as the reference SSFP sequence. • The fast SPARSE-SENSE sequence is an attractive alternative to standard SSFP sequences.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Isquemia Miocárdica/diagnóstico por imagen , Miocarditis/diagnóstico por imagen , Función Ventricular Izquierda , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Corazón/diagnóstico por imagen , Ventrículos Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Respiración , Volumen Sistólico , Adulto Joven
9.
Pharmaceuticals (Basel) ; 17(1)2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-38256934

RESUMEN

Transarterial chemoembolization (TACE) is currently the standard of care in patients with unresectable hepatocellular carcinoma (HCC), and selective internal radionuclide therapy (SIRT) with 90Y microspheres is mainly used as an alternative modality in patients considered poor candidates for TACE. Treatment with sorafenib is the recommended option for patients with progressive disease after TACE. This study aims to evaluate the safety and efficacy of SIRT with glass microspheres in patients with progressive HCC after repeated TACE who are not eligible for treatment with sorafenib. Forty-seven patients with progressive HCC after a median of three TACE sessions (range 2-14) underwent SIRT (3.5 ± 1.5 GBq; liver target dose 110-120 Gy). Toxicity was recorded 4 and 12 weeks after treatment and reported according to the Common Terminology Criteria for Adverse Events Version 5.0. Treatment response was assessed three months after SIRT using multiphase computed tomography and modified criteria in solid tumors (mRECIST). Survival analyses were performed using Kaplan-Meier curves and a Cox proportional hazards model for uni- and multivariate analyses. Significant but reversible hepatotoxicity (≥grade 3) occurred in five patients (11%). No radioembolization-induced liver disease (REILD) was observed. The number of previous TACE sessions and cumulative administered activity did not predict the incidence of post-SIRT significant hepatotoxicity. Treatment responses consisted of partial responses in 26 (55%), stable disease in 12 (26%), and progressive disease in 9 (19%) patients. The median overall survival (OS) was 11 months (95% confidence interval (CI), 9-13), and objective responses to SIRT were associated with a longer OS (p = 0.008). Significant hepatotoxicity (≥grade 3) after SIRT was a contributor to impaired survival (median OS 6 months (95% CI, 4-8) vs. 12 months (95% CI, 10-14), p < 0.001). SIRT with glass microspheres is a safe and effective salvage treatment for patients with progressive HCC refractory to TACE who are considered poor candidates for sorafenib treatment.

10.
GMS Hyg Infect Control ; 14: Doc05, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31198659

RESUMEN

Aim: To quantify the frequency of bacterial contamination of the injected contrast agent/saline solution by an automated contrast injection system, and to evaluate whether usage of a novel tube system can reduce it. Methods: For bacterial contamination quantification two identical automated piston pump MRI contrast injectors were used in combination with a standard tube system. 3-5 ml of the contrast agent/saline solution was collected from the system prior to its connection to the patients' venous cannula in 104 consecutive patients. To test, whether a novel tube system reduces contamination, a tube system with shielded screw connections was used with the same contrast injectors and contrast agent/saline samples were collected in further 101 patients. Specimens were microbiologically analyzed. Frequencies of contamination were compared using Fisher exact test. Results: With the standard tube system, bacterial contamination was observed in 5.8% (6 out of 104 specimens). With the novel tube system, contamination was observed in 2.0% (2 out of 101 specimens, p=0.280). Staphylococcus epidermidis was the most common germ (5 cases) followed by Micrococcus luteus (2 cases) and Oligella ureolytica (1 case). Conclusion: Bacterial contaminations of MRI contrast injectors occurred in a non-negligible frequency especially with S. epidermidis. A trend towards reduced bacterial contamination was seen when a novel tube system with shielded screw connections was used.

11.
Acad Radiol ; 26(10): e298-e304, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30587388

RESUMEN

RATIONALE AND OBJECTIVES: Mechanical thrombectomy is common practice in proximal anterior vessel occlusion. However, it remains unclear whether peripheral artery occlusions should be treated as well. This retrospective study aimed to prove the effectiveness of endovascular recanalization treatment for the M2 segment by comparison of intracranial internal carotid artery (ICA), M1 segment, and M2 segment thrombectomy. MATERIALS AND METHODS: All patients who received endovascular treatment for distal ICA, M1, or M2 segment occlusions between January 2010 and July 2017 at our center were re-analyzed with respect to reperfusion success, interventional and clinical parameters. Statistical analysis was performed by Mann Whitney test, Chi square test, and Spearman correlation analysis. RESULTS: A total of 261 patients (median age, 72 years), 100 with ICA, 137 with M1, and 24 with M2 segment occlusion, were included. Duration of endovascular treatment was significantly longer in ICA occlusions (median, 83 minutes, p < 0.001) compared to M1 (56 minutes) or M2 segment occlusions (49 minutes). Recanalization and reperfusion success and rate of endovascular complications did not differ between occlusion sites (AOL, p = 0.071; mTICI, p = 0.540; complications, p = 0.064). No significant difference in revascularization success was found between the different thrombectomy devices (direct thrombus aspiration, stent retrieving, or a sequential combined approach; p = 0.112). Successful M2 recanalization (mTICI 2b-3) correlated significantly with stronger posttherapeutic NIHSS reduction (r = 0.691, p < 0.001). CONCLUSION: We found endovascular treatment of M2 segment occlusions as safe and successful as endovascular therapy of the ICA or M1 segment, with stronger posttherapeutic NIHSS reduction after successful compared to insufficient M2 recanalization.


Asunto(s)
Arteriopatías Oclusivas/cirugía , Arteria Carótida Interna/cirugía , Procedimientos Endovasculares/métodos , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Anciano , Femenino , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
12.
Eur J Radiol Open ; 5: 159-164, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30225274

RESUMEN

INTRODUCTION: This study examined the feasibility of aortic valve planimetry at 7 T ultrahigh field MRI in intraindividual comparison to 3 T and 1.5 T MRI. MATERIAL AND METHODS: Aortic valves of eleven healthy volunteers (mean age, 26.4 years) were examined on a 7 T, 3 T, and 1.5 T MR system using FLASH and TrueFISP sequences. Two experienced radiologists evaluated overall image quality, the presence of artefacts, tissue contrast ratios, identifiability, and image details of the aortic valve opening area (AVOA). Furthermore, AVOA was quantified twice by reader 1 and once by reader 2. Correlation analysis between artefact severity and employed magnetic field strength was performed by modified Fisher's exact-test. Paired t-test was used to analyse for AVOA differences, and Bland-Altman plots were used to analyse AVOA intra-rater and inter-rater variability. RESULTS: Aortic valve imaging at 7 T, 3 T, and 1.5 T with using FLASH was less hampered by artefacts than TrueFISP imaging at 3 T and 1.5 T. Tissue contrast and image details were rated best at 7 T. AVOA was measured slightly smaller at 7 T compared to 3 T (TrueFISP, p-value = 0.057; FLASH, p-value = 0.016) and 1.5 T (TrueFISP, p-value = 0.029; FLASH, p-value = 0.018). Intra-rater and inter-rater variability of AVOA tended to be slightly smaller at 7 T than at 3 T and 1.5 T. CONCLUSION: Aortic valve planimetry at 7 T ultrahigh field MRI is technically feasible and in healthy volunteers offers an improved tissue contrast and a slightly better reproducibility than MR planimetry at 1.5 T and 3 T.

13.
J Cancer Res Clin Oncol ; 143(12): 2527-2533, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28825135

RESUMEN

PURPOSE: Standardized computer-aided tumor response assessment is common in clinical trials. In contrast, unstructured free text reporting (UFTR) is common in daily routine. Therefore, this study aimed to discern and quantify differences between UFTR and computer-aided standardized tumor response evaluation based on RECIST 1.1 criteria (RECIST), serving as gold standard, in clinical workflow. METHODS: One-hundred consecutive patients with cancer eligible for RECIST 1.1 evaluation, who received five follow-up CTs of the trunk, were retrospectively included. All UFTRs were assigned to RECIST response categories [complete response, partial response (PR), stable disease (SD), progressive disease (PD)]. All CTs were re-evaluated using dedicated software (mint lesion™) applying RECIST 1.1. The accordance in tumor response ratings was analyzed using Cohen's kappa. RESULTS: At the first follow-up, 47 cases were rated differently with an SD underrepresentation and a PR and PD overrepresentation in UFTR. In the subsequent follow-ups, categorical differences were seen in 38, 44, 37, and 44%. Accordance between UFTR and RECIST was fair to moderate (Cohen's kappa: 0.356, 0.477, 0.390, 0.475, 0.376; always p < 0.001). Differences were mainly caused by the rating of even small tumor burden changes as PD or PR in UFTR or by comparison to the most recent prior CT scan in UFTR instead of comparison to nadir or baseline. CONCLUSIONS: Significant differences in tumor response ratings were detected comparing UFTR and computer-aided standardized evaluation based on RECIST 1.1. Thus, standardized reporting should be implemented in daily routine workflow.


Asunto(s)
Documentación/métodos , Neoplasias/diagnóstico por imagen , Criterios de Evaluación de Respuesta en Tumores Sólidos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico por Computador , Femenino , Control de Formularios y Registros , Registros de Salud Personal , Humanos , Masculino , Persona de Mediana Edad , Neoplasias/terapia , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Carga Tumoral , Adulto Joven
14.
PLoS One ; 12(7): e0181488, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28708902

RESUMEN

INTRODUCTION: Radioembolization for the treatment of hepatocellular carcinoma (HCC) induces liver volume changes referred to as "atrophy-hypertrophy complex". The aim of this study was to investigate lobar liver volume changes after unilateral radioembolization and to search for factors associated with hypertrophy of the untreated lobe. MATERIALS AND METHODS: Seventy-five patients were retrospectively evaluated. Inclusion criteria were: (1) right-lobar radioembolization for unresectable unilateral HCC, (2) available liver computed tomography scans before, 1, 3, and at least 6 months after radioembolization. Baseline patient characteristics included clinical features, laboratory results, spleen volume, and liver computed tomography. Absolute and relative (referred to the whole liver volume) liver lobe volumes (LLV) as well as relative LLV (rLLV) change per month were evaluated and compared. RESULTS: Absolute and relative contralateral LLV continuously increased after radioembolization (p<0.001). Mean relative contralateral LLV increased from 36±11.6% before radioembolization to 50±15.3% 6 months after radioembolization. Median contralateral rLLV increase/month (within first 6 months) was 2.5%. Contralateral rLLV increase/month was significantly lower in patients with ascites (p = 0.017) or platelet count <100/nl (p = 0.009). An inverse correlation of contralateral rLVV increase/month with spleen volume (p = 0.017), patient age (p = 0.024), Child Pugh score (p = 0.001), and tumor burden (p = 0.001) was found. CONCLUSIONS: Significant contralateral hypertrophy and ipsilateral atrophy were common after unilateral radioembolization. Small spleen volume, low patient age, low Child Pugh score, absence of ascites, platelet count ≥100/nl, and low tumor burden were associated with increased contralateral hypertrophy, indicating that younger patients with compensated cirrhosis might benefit most from radioembolization in a "bridge-to-resection" setting.


Asunto(s)
Carcinoma Hepatocelular/terapia , Embolización Terapéutica , Hepatomegalia/etiología , Neoplasias Hepáticas/terapia , Factores de Edad , Anciano , Carcinoma Hepatocelular/mortalidad , Carcinoma Hepatocelular/patología , Femenino , Hepatomegalia/diagnóstico por imagen , Humanos , Hígado/diagnóstico por imagen , Hígado/fisiología , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Recuento de Plaquetas , Radiofármacos/química , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Bazo/diagnóstico por imagen , Bazo/fisiología , Tomografía Computarizada por Rayos X , Carga Tumoral , Radioisótopos de Itrio/química
15.
PLoS One ; 11(5): e0155591, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27219329

RESUMEN

OBJECTIVES: T1 mapping allows quantitative myocardial assessment, but its value in clinical routine remains unclear. We investigated, whether the average native myocardial T1 value can be used as a diagnostic classifier between healthy and diffuse diseased myocardium. METHODS: Native T1 mapping was performed in 54 persons with healthy hearts and in 150 patients with diffuse myocardial pathologies (coronary artery disease (CAD): n = 76, acute myocarditis: n = 19, convalescent myocarditis: n = 26, hypertrophic cardiomyopathy (HCM): n = 12, dilated cardiomyopathy (DCM): n = 17) at 1.5 Tesla in a mid-ventricular short axis slice using a modified Look-Locker inversion recovery (MOLLI) sequence. The average native myocardial T1 value was measured using dedicated software for each patient. The mean as well as the range of the observed average T1 values were calculated for each group, and compared using t-test. The ability of T1 mapping to differentiate between healthy and diffuse diseased myocardium was assessed using receiver operating characteristic analysis (ROC). RESULTS: The mean T1 value of the group "healthy hearts" (955±34ms) differed significantly from that of the groups DCM (992±37ms, p<0.001), HCM (980±44ms, p = 0.035), and acute myocarditis (974±36ms, p = 0.044). No significant difference was observed between the groups "healthy hearts" and CAD (951±37ms, p = 0.453) or convalescent myocarditis (965±40ms, p = 0.240). The average native T1 value varied considerably within all groups (range: healthy hearts, 838-1018ms; DCM, 882-1034ms; HCM, 897-1043ms; acute myocarditis, 925-1025ms; CAD, 867-1082ms; convalescent myocarditis, 890-1071ms) and overlapped broadly between all groups. ROC analysis showed, that the average native T1 value does not allow for differentiating between healthy and diffuse diseased myocardium, except for the subgroup of DCM. CONCLUSIONS: The average native T1 value in cardiac MR imaging does not allow differentiating between healthy and diffusely diseased myocardium in individual cases.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Miocarditis/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Estudios Retrospectivos , Adulto Joven
16.
PLoS One ; 11(12): e0167596, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27907162

RESUMEN

INTRODUCTION: The objective of this study was to assess the diagnostic value of integrated 11C- methionine PET/MRI for suspected primary brain tumors, in comparison to MRI alone. MATERIAL AND METHODS: Forty-eight consecutive patients with suspected primary brain tumor were prospectively enrolled for an integrated 11C-methionine PET/MRI. Two neuro-radiologists separately evaluated the MRI alone and the integrated PET/MRI data sets regarding most likely diagnosis and diagnostic confidence on a 5-point scale. Reference standard was histopathology or follow-up imaging. RESULTS: Fifty-one suspicious lesions were detected: 16 high-grade glioma and 25 low-grade glioma. Ten non-malignant cerebral lesions were described by the reference standard. MRI alone and integrated PET/MRI each correctly classified 42 of the 51 lesions (82.4%) as neoplastic lesions (WHO grade II, III and IV) or non-malignant lesions (infectious and neoplastic lesions). Diagnostic confidence for all lesions, low-grade astrocytoma and high-grade astrocytoma (3.7 vs. 4.2, 3,1 vs. 3.8, 4.0 vs. 4,7) were significantly (p < 0.05) better with integrated PET/MRI than in MRI alone. CONCLUSIONS: The present study demonstrates the high potential of integrated 11C-methionine-PET/MRI for the assessment of suspected primary brain tumors. Although integrated methionine PET/MRI does not lead to an improvement of correct diagnoses, diagnostic confidence is significantly improved.


Asunto(s)
Neoplasias Encefálicas/diagnóstico , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Adulto , Anciano , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Medios de Contraste/administración & dosificación , Femenino , Humanos , Masculino , Metionina/administración & dosificación , Persona de Mediana Edad , Imagen Multimodal , Radioisótopos/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA