Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-38820201

RESUMEN

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Asunto(s)
Endocarditis , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/mortalidad , Endocarditis/cirugía , Endocarditis/mortalidad , Remoción de Dispositivos , Prótesis Valvulares Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Resultado del Tratamiento , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
2.
J Extra Corpor Technol ; 56(2): 55-64, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38888548

RESUMEN

BACKGROUND: The Perfusion Measures and Outcomes (PERForm) registry was established in 2010 to advance cardiopulmonary bypass (CPB) practices and outcomes. The registry is maintained through the Michigan Society of Thoracic and Cardiovascular Surgeons Quality Collaborative and is the official registry of the American Society of Extracorporeal Technology. METHODS: This first annual PERForm registry report summarizes patient characteristics as well as CPB-related practice patterns in adult (≥18 years of age) patients between 2019 and 2022 from 42 participating hospitals. Data from PERForm are probabilistically matched to institutional surgical registry data. Trends in myocardial protection, glucose, anticoagulation, temperature, anemia (hematocrit), and fluid management are summarized. Additionally, trends in equipment (hardware/disposables) utilization and employed patient safety practices are reported. RESULTS: A total of 40,777 adult patients undergoing CPB were matched to institutional surgical registry data from 42 hospitals. Among these patients, 54.9% underwent a CABG procedure, 71.6% were male, and the median (IQR) age was 66.0 [58.0, 73.0] years. Overall, 33.1% of the CPB procedures utilized a roller pump for the arterial pump device, and a perfusion checklist was employed 99.6% of the time. The use of conventional ultrafiltration decreased over the study period (2019 vs. 2022; 27.1% vs. 24.9%) while the median (IQR) last hematocrit on CPB has remained stable [27.0 (24.0, 30.0) vs. 27.0 (24.0, 30.0)]. Pump sucker termination before protamine administration increased over the study period: (54.8% vs. 75.9%). CONCLUSION: Few robust clinical registries exist to collect data regarding the practice of CPB. Although data submitted to the PERForm registry demonstrate overall compliance with published perfusion evidence-based guidelines, noted opportunities to advance patient safety and outcomes remain.


Asunto(s)
Puente Cardiopulmonar , Sistema de Registros , Humanos , Sistema de Registros/estadística & datos numéricos , Masculino , Anciano , Puente Cardiopulmonar/estadística & datos numéricos , Puente Cardiopulmonar/instrumentación , Persona de Mediana Edad , Femenino , Michigan , Adulto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA