1.
Catheter Cardiovasc Interv ; 102(4): 569-576, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37548088

RESUMEN

BACKGROUND: Acute myocardial infarction complicated by cardiogenic shock (AMI-CS) is the most common cause of mortality following AMI, and treatment algorithms vary widely. We report the results of an analysis using time-sensitive, hemodynamic goals in the treatment of AMI-CS in a single center study. METHODS: Consecutive patients with AMI-CS from November 2016 through December 2021 were included in our retrospective analysis. Clinical characteristics and outcomes were analyzed using the electronic medical records. We identified 63 total patients who were admitted to our center with AMI-CS, and we excluded patients who did not have clear timing of AMI onset or CS onset. We evaluated the rate of survival to hospital discharge based on the quantity of certain time-sensitive hemodynamic goals were met. RESULTS: We identified 63 patients who met criteria for AMI-CS, 39 (62%) of whom survived to hospital discharge. Odds of survival were closely related to the achievement of four time-dependent goals: cardiac power output (CPO) >0.6 Watts (W), pulmonary artery pulsatility index (PAPi) >1, lactate <4 mmol/L, and <2 vasopressors required. Of the 63 total patients, 36 (57%) received intra-aortic balloon pump (IABP) and 18 (29%) received an Impella CP (Abiomed) as an initial mechanical circulatory support strategy. Six patients were escalated from IABP to Impella CP for additional hemodynamic support. Nine patients were treated with vasopressors/inotropes alone. Regarding the 39 patients who survived to hospital discharge, 75% of patients met 3 or 4 goals at 24 h, whereas only 16% of deceased patients met 3 or 4 goals at 24 h. Of the 24 patients who did not survive to hospital discharge, 18 (75%) met either 0-1 goal at 24 h. There was no effect of the initial treatment strategy on achieving 3-4 goals at 24 h. CONCLUSION: Our study evaluated the association of meeting 4 time-sensitive goals (CPO >0.6 W, PAPi >1, <2 vasopressors, and lactate <4 mmol/L) at 24 h after treatment for AMI-CS with in-hospital mortality. Our data show, in line with previous data, that the higher number of goals met at 24 h was associated with improved in-hospital mortality regardless of treatment strategy.


Asunto(s)
Corazón Auxiliar , Infarto del Miocardio , Humanos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Estudios Retrospectivos , Objetivos , Resultado del Tratamiento , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia , Hemodinámica , Contrapulsador Intraaórtico/efectos adversos , Corazón Auxiliar/efectos adversos , Lactatos
2.
Transfusion ; 59(9): 2783-2787, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31271458

RESUMEN

BACKGROUND: In a recent study, we determined that 30% of frequent plateletpheresis donors collected using the Trima Accel Automated Blood Collection System (Terumo BCT) had a CD4+ T-cell count below 200 cells/µL. Whether CD4+ T-cell lymphopenia is associated with donation using other plateletpheresis instruments is unknown. STUDY DESIGN AND METHODS: We obtained blood samples from 30 current frequent Fenwal Amicus plateletpheresis donors. All participants had made 20 to 24 plateletpheresis donations in the most recent 365-day period, and all had previously donated over 50 times on the Fenwal Amicus instrument. Blood samples were analyzed to determine blood counts, including CD4+ and CD8+ counts. RESULTS: Of 30 study participants, none had a CD4+ count below 200 cells/µL. There was one participant with a CD4+ count between 200 and 300 cells/µL. This individual was over the age of 55 and had a history of more than 300 lifetime plateletpheresis sessions. One participant had a CD8+ count below the lower limit of normal (125 cells/µL) and a normal CD4+ count. CONCLUSION: We did not detect severe CD4+ lymphopenia in frequent platelet donors undergoing plateletpheresis with the Fenwal Amicus. Since the Fenwal Amicus does not incorporate a leukoreduction system chamber, this finding supports the hypothesis that such chambers-found in the Trima Accel instrument-contribute to CD4+ lymphopenia in frequent platelet donors.


Asunto(s)
Donantes de Sangre/estadística & datos numéricos , Linfocitos T CD4-Positivos/patología , Linfopenia/epidemiología , Plaquetoferesis/instrumentación , Plaquetoferesis/estadística & datos numéricos , Anciano , Estudios de Cohortes , Diseño de Equipo , Femenino , Humanos , Incidencia , Linfopenia/etiología , Linfopenia/patología , Masculino , Persona de Mediana Edad , Plaquetoferesis/métodos , Índice de Severidad de la Enfermedad
3.
ASAIO J ; 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38810218

RESUMEN

Currently, the fully magnetically levitated left ventricular assist device (LVAD) HeartMate 3 (HM3) is the only commercially available device for advanced heart failure (HF) patients. However, the left ventricular (LV) functional and structural changes following mechanical unloading and circulatory support (MCS) with the HM3 have not been investigated. We compared the reverse remodeling induced by the HM3 to older generation continuous-flow LVADs. Chronic HF patients (n = 405) undergoing MCS with HeartWare Ventricular Assist Device (HVAD, n = 115), HM3 (n = 186), and HeartMate II (HM2, n = 104) at four programs were included. Echocardiograms were obtained preimplant and at 1, 3, 6, and 12 months following LVAD implantation. There were no differences in the postimplant serial LV ejection fraction (LVEF) between the devices. The postimplant LV internal diastolic diameter (LVIDd) was significantly lower for HM2 at 3 and 6 months compared with HVAD and HM3. The proportion of patients achieving "cardiac reverse remodeling responder" status (defined as LVEF improvement to ≥40% and LVIDD ≤5.9 cm) was 11.9%, and was similar between devices. HeartMate 3 appears to result in similar cardiac reverse remodeling as older generation CF-LVADs, suggesting that the fully magnetically levitated device technology could provide an effective platform to further study and promote cardiac reverse remodeling.

4.
Clin Appl Thromb Hemost ; 28: 10760296211072820, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35018865

RESUMEN

BACKGROUND: Patients with end-stage renal disease (ESRD) often present with an increased risk of cardiovascular disease. Conditions of compromised cardiovascular health such as atrial fibrillation (AFIB) and peripheral arterial disease (PAD) may alter biomarker levels in a way that reflects worsening ESRD. This study profiled biomarkers and laboratory parameters of endothelium dysfunction in patients with ESRD, categorized by additional AFIB and PAD conditions. METHODS: Citrated blood samples were collected from 95 patients with ESRD. Biomarker levels were measured from plasma samples using sandwich ELISAs, including tissue plasminogen activator (tPA), D-dimer, and nitrotyrosine. Lab parameters, including BUN, calcium, creatinine, parathyroid hormone, phosphate, alkaline phosphatase, ferritin, transferrin, and total iron capacity, and patient comorbidities were obtained from patient medical records. The comorbidities were determined through provider notes, and evidence of applicable testing. RESULTS: 14.89% of patients were found to have atrial fibrillation (n = 14), 30.85% of patients were found to have peripheral arterial disease (n = 29), and 6.38% of patients were found to have both peripheral arterial disease and atrial fibrillation (n = 6). When compared to patients with only ESRD, patients with ESRD and PAD showed elevated levels of D-Dimer (p = .0314) and nitrotyrosine (p = .0330). When compared to patients with only ESRD, patients with atrial fibrillation showed elevated levels of D-Dimer (p = .0372), nitrotyrosine (p = .0322), and tPA (p = .0198). CONCLUSION: When compared to patients with just ESRD, patients with concomitant PAD had elevated levels of Nitrotyrosine and D-dimer; while patients with concomitant Afib had elevated levels of nitrotyrosine, D-dimer, as well as tPA.


Asunto(s)
Síndrome Cardiorrenal/etiología , Productos de Degradación de Fibrina-Fibrinógeno/metabolismo , Fallo Renal Crónico/complicaciones , Anciano , Biomarcadores/sangre , Síndrome Cardiorrenal/sangre , Síndrome Cardiorrenal/epidemiología , Femenino , Humanos , Incidencia , Fallo Renal Crónico/epidemiología , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Diálisis Renal/métodos , Factores de Riesgo , Estados Unidos/epidemiología