Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Vasc Surg ; 67(5): 1438-1447, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29169878

RESUMEN

OBJECTIVE: The objective of this study was to demonstrate the 3-year outcome of the covered endovascular reconstruction of the aortic bifurcation (CERAB) technique for the treatment of extensive aortoiliac occlusive disease (AIOD). METHODS: Between February 2009 and July 2016, all patients treated with the CERAB technique for AIOD were identified in the local databases of two centers and analyzed. Demographics and lesion characteristics were scored. Follow-up consisted of clinical assessment, duplex ultrasound, and ankle-brachial indices. Patency rates and clinically driven target lesion revascularization were calculated by Kaplan-Meier analysis. RESULTS: Of 130 patients (69 male and 61 female) treated, 68% were diagnosed with intermittent claudication and 32% suffered from critical limb ischemia. The majority (89%) were TransAtlantic Inter-Society Consensus II D lesions, and the remaining were B and C lesions (both 5%). Median follow-up was 24 months (range, 0-67 months). The technical success rate was 97%, and 67% of cases were performed completely percutaneously. The ankle-brachial index improved significantly from 0.65 ± 0.22 preoperatively to 0.88 ± 0.15 after the procedure. The 30-day minor and major complication rate was 33% and 7%. The median hospital stay was 2 days (range, 1-76 days). At 1 year and 3 years of follow-up, 94% and 96% of the patients clinically improved at least one Rutherford category (2% and 0% unchanged, 4% and 4% worsened). Limb salvage rate was 98% at 1 year and 97% at 3 years of follow-up. Primary, primary assisted, and secondary patency was 86%, 91%, and 97% at 1 year; 84%, 89%, and 97% at 2 years; and 82%, 87%, and 97% at 3 years. Freedom from clinically driven target lesion revascularization was 87% at 1-year follow-up and 86% at both 2-year and 3-year follow-up. CONCLUSIONS: The CERAB technique is a safe and feasible technique for the treatment of extensive AIOD with good 3-year results regarding patency and clinical improvement.


Asunto(s)
Enfermedades de la Aorta/cirugía , Arteriopatías Oclusivas/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Stents , Adulto , Anciano , Anciano de 80 o más Años , Índice Tobillo Braquial , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/fisiopatología , Aortografía/métodos , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Bélgica , Implantación de Prótesis Vascular/efectos adversos , Distribución de Chi-Cuadrado , Procedimientos Endovasculares/efectos adversos , Femenino , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/terapia , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Estimación de Kaplan-Meier , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Países Bajos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular
2.
J Vasc Surg ; 66(1): 251-260.e1, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-27743806

RESUMEN

BACKGROUND: Endovascular treatment of aortoiliac occlusive disease entails the use of multiple stents to reconstruct the aortic bifurcation. Different configurations have been applied and geometric variations exist, as quantified in previous work. Other studies concluded that specific stent geometry seems to affect patency. These variations may affect local flow patterns, resulting in different wall shear stress (WSS) and oscillating shear index (OSI). The aim of this study was to compare the effect of different stent configurations on flow perturbations (recirculation and fluid stasis), WSS, and OSI in an in vitro setup. METHODS: Three different stent configurations were deployed in transparent silicone models: bare-metal kissing (BMK) stents, covered kissing (CK) stents, and the covered endovascular reconstruction of the aortic bifurcation (CERAB) configuration. Transparent covered stents were created with polyurethane to enable visualization. Models were placed in a circulation setup under physiologic flow conditions. Time-resolved laser particle image velocimetry techniques were used to quantify the flow, and WSS and OSI were calculated. RESULTS: The BMK configuration did not show flow disturbances at the inflow section, and WSS values were similar to the control. An area of persistent low flow was observed throughout the cardiac cycle in the area between the anatomic bifurcation and neobifurcation. The CK model showed recirculation zones near the inflow area of the stents with a resulting low average WSS value and high OSI. The proximal inflow of the CERAB configuration did not show flow disturbances, and WSS values were comparable to control. Near the inflow of the limbs, a minor zone of recirculation was observed without changes in WSS values. Flow, WSS, and OSI on the lateral wall of the proximal iliac artery were undisturbed in all models. CONCLUSIONS: The studied aortoiliac stent configurations have distinct locations where flow disturbances occur, and these are related to the radial mismatch. The CERAB configuration is the most unimpaired physiologic reconstruction, whereas BMK and CK stents have their typical zones of flow recirculation.


Asunto(s)
Angioplastia de Balón/instrumentación , Enfermedades de la Aorta/terapia , Arteriopatías Oclusivas/terapia , Hemodinámica , Arteria Ilíaca/fisiopatología , Stents , Enfermedades de la Aorta/diagnóstico , Enfermedades de la Aorta/fisiopatología , Arteriopatías Oclusivas/diagnóstico , Arteriopatías Oclusivas/fisiopatología , Velocidad del Flujo Sanguíneo , Constricción Patológica , Humanos , Modelos Anatómicos , Modelos Cardiovasculares , Diseño de Prótesis , Flujo Sanguíneo Regional , Factores de Tiempo
3.
J Endovasc Ther ; 24(1): 19-24, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27742898

RESUMEN

PURPOSE: To show feasibility of the covered endovascular repair of the aortic bifurcation (CERAB) technique in conjunction with chimney grafts in aortic side branches for complex aortoiliac occlusive disease. METHODS: Two European centers and one facility located in New Zealand participated in a retrospective observational study that enrolled 14 consecutive patients (mean age 61.2±8.9 years; 11 men) treated with CERAB in conjunction with chimney graft(s) between December 2012 and May 2015. Indications for treatment included disabling claudication in 9 and critical limb ischemia in 5. Lesions were classified as TransAtlantic Inter-Society Consensus II B (n=1), C (n=1), or D (n=12). RESULTS: A total of 15 chimney grafts were used to perfuse the inferior mesenteric artery (n=8), the right renal artery (n=4), and the left renal artery (n=3). Technical success was achieved in all cases. Procedural complications included 5 unintended dissections and 1 vessel thrombosis, all of which were successfully treated intraoperatively. Five patients developed access-site hematoma/ecchymosis (3 at the brachial access). Mean follow-up was 12 months (range 6-24) without death or loss to follow-up. One patient suffered occlusion of a CERAB limb and an IMA chimney graft; the former was recanalized, but the IMA graft was not; there were no signs of bowel ischemia. Ankle-brachial indices significantly increased from 0.54 (range 0.47-0.60) preoperatively to 0.97 (range 0.90-1.00) in 11 patients examined at 12 months, and all patients had an improvement in the Rutherford category. All CERAB limbs, including the one recanalized, were patent at the most recent follow-up, as were 14 of 15 chimney grafts. CONCLUSION: Chimney-CERAB is technically feasible and may offer an alternative to open surgery for complex aortoiliac occlusive disease. Further prospective studies are needed to confirm these findings.


Asunto(s)
Enfermedades de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Enfermedad Arterial Periférica/cirugía , Stents , Anciano , Índice Tobillo Braquial , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/fisiopatología , Aortografía , Bélgica , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Masculino , Persona de Mediana Edad , Países Bajos , Nueva Zelanda , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
4.
J Vasc Surg ; 61(5): 1306-11, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24486037

RESUMEN

OBJECTIVE: Kissing stents (KS) are commonly used to treat aortoiliac occlusive disease, but patency results are often lower than those of isolated stents. The Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) technique was recently introduced to reconstruct the aortic bifurcation in a more anatomical and physiological fashion. The aim of this study is to compare the geometrical consequences of various stent configurations in vitro. METHODS: Anatomic vessel phantoms of the aortoiliac bifurcation were created to accommodate stent configurations. Self-expandable nitinol KS, balloon-expandable covered KS, and two versions of the CERAB configuration were deployed, one with the iliac legs positioned inside the tapered part of the aortic cuff (1) and one with the legs deployed above this level (2). Computed tomography data were obtained to assess the geometry. The conformation ratio (D-ratio) was calculated by use of the ratio of the major and minor axes. The proximal mismatch area, mean mismatch area, and total mismatch volume were calculated. RESULTS: The highest D-ratios were observed in the nitinol KS and the CERAB configuration, implying an ideal "double-D" shape. The proximal and mean mismatch areas were four- to sixfold lower in the CERAB (1) configuration when compared with nitinol KS and CERAB (2), respectively, whereas the covered KS had the highest mismatch area. Nitinol and covered KS had the largest mismatch volume, whereas the mismatch volume was the lowest in the CERAB (1) configuration. CONCLUSIONS: Although nitinol self-expandable stents have a high stent conformation, the lowest radial mismatch was found in the CERAB (1) configuration, supporting the hypothesis that the CERAB configuration is the most anatomical and physiological reconstruction of the aortic bifurcation. Within the CERAB configuration, the two limbs are ideally positioned inside the tapering portion of the cuff, minimizing mismatch.


Asunto(s)
Aleaciones , Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Diseño de Equipo , Arteria Ilíaca/cirugía , Modelos Cardiovasculares , Stents , Aorta Abdominal/diagnóstico por imagen , Humanos , Arteria Ilíaca/diagnóstico por imagen , Técnicas In Vitro , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA