1.
Am J Transplant ; 16(7): 2181-6, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26718625

RESUMEN

Transplant recipients receiving a kidney from an extended-criteria donor (ECD) are exposed to calcineurin inhibitor (CNI) nephrotoxicity, as demonstrated by severe delayed graft function and/or a low GFR. Belatacept is a nonnephrotoxic drug that is indicated as an alternative to CNIs. We reported 25 cases of conversion from a CNI to belatacept due to CNI intolerance within the first 6 mo after transplantation. The mean age of the recipients was 59 years, and 24 of 25 patients received ECD kidneys. At the date of the medication switch, 12 of 25 patients displayed a calculated GFR (cGFR) <15 mL/min, six patients remained on dialysis, and the biopsies showed evidence of acute tubular damage associated with severe vascular or tubulointerstitial chronic lesions. Three patients did not recover renal function, and three patients died during the follow-up period. Among the remaining patients, renal function improved: The cGFR was 18.28 ± 12.3 mL/min before the medication switch compared with 34.9 ± 14.5 mL/min at 1 year after conversion to belatacept (p = 0.002). Tolerance of and compliance with belatacept were good, and only one patient experienced acute rejection. Belatacept is an effective therapy that preserves renal function in kidney transplant patients who are intolerant of CNIs.


Asunto(s)
Abatacept/uso terapéutico , Inhibidores de la Calcineurina/efectos adversos , Resistencia a Medicamentos/efectos de los fármacos , Rechazo de Injerto/tratamiento farmacológico , Fallo Renal Crónico/cirugía , Trasplante de Riñón/efectos adversos , Anciano , Funcionamiento Retardado del Injerto/tratamiento farmacológico , Funcionamiento Retardado del Injerto/etiología , Femenino , Estudios de Seguimiento , Tasa de Filtración Glomerular , Rechazo de Injerto/etiología , Supervivencia de Injerto/efectos de los fármacos , Humanos , Inmunosupresores/uso terapéutico , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Receptores de Trasplantes
2.
Anal Chem ; 72(3): 591-8, 2000 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-10695147

RESUMEN

Recent advances in column heating technology have made possible very fast linear temperature programming for high-speed gas chromatography. A fused-silica capillary column is contained in a tubular metal jacket, which is resistively heated by a precision power supply. With very rapid column heating, the rate of peak-capacity production is significantly enhanced, but the total peak capacity and the boiling-point resolution (minimum boiling-point difference required for the separation of two nonpolar compounds on a nonpolar column) are reduced relative to more conventional heating rates used with convection-oven instruments. As temperature-programming rates increase, elution temperatures also increase with the result that retention may become insignificant prior to elution. This results in inefficient utilization of the down-stream end of the column and causes a loss in the rate of peak-capacity production. The rate of peak-capacity production is increased by the use of shorter columns and higher carrier gas velocities. With high programming rates (100-600 degrees C/min), column lengths of 6-12 m and average linear carrier gas velocities in the 100-150 cm/s range are satisfactory. In this study, the rate of peak-capacity production, the total peak capacity, and the boiling point resolution are determined for C10-C28 n-alkanes using 6-18 m long columns, 50-200 cm/s average carrier gas velocities, and 60-600 degrees C/min programming rates. It was found that with a 6-meter-long, 0.25-mm i.d. column programmed at a rate of 600 degrees C/min, a maximum peak-capacity production rate of 6.1 peaks/s was obtained. A total peak capacity of about 75 peaks was produced in a 37-s long separation spanning a boiling-point range from n-C10 (174 degrees C) to n-C28 (432 degrees C).

3.
Nucl Med Biol ; 24(1): 85-92, 1997 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9080479

RESUMEN

105Rh(III)Cl2 complexes with a limited series of [14]ane- and [16]ane- thia macrocycles were prepared and their biodistributions in Sprague-Dawley rats studied. These studies demonstrate that modifications in the structure and composition of the 105Rh-thia macrocycle complexes produce significant differences in their uptake and retention in both the liver and kidneys. The results indicate that the cis-Rh(III)Cl2-[14]ane thiamacrocycles exhibit less kidney retention than the corresponding trans-Rh(III)Cl2-[16]ane thiamacrocycles. In addition, the presence of a side chain containing a carboxylate group will produce decreased retention of activity in the kidneys. HPLC analysis of urine from these animals indicates no observable in vivo metabolism or dissociation of these chelates in the blood stream.


Asunto(s)
Compuestos Heterocíclicos/síntesis química , Compuestos Heterocíclicos/farmacocinética , Rodio , Animales , Ligandos , Radioisótopos , Ratas , Ratas Sprague-Dawley , Estereoisomerismo , Relación Estructura-Actividad , Distribución Tisular
5.
Anal Chem ; 72(11): 2507-13, 2000 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-10857627

RESUMEN

A pressure-tunable ensemble of two series-coupled capillary columns operated at subambient outlet pressure is described. The ensemble consists of a 4.5-m length of nonpolar dimethyl polysiloxane column followed by a 7.5-m length of polar trifluoropropylmethyl polysiloxane column. Air at an inlet pressure of 1.0 atm is used as carrier gas, and a vacuum pump is used to pull the carrier gas and injected samples through the column ensemble. Detection is provided by a photoionization detector operated at a pressure of 0.3 psia. Ensemble selectivity is controlled by means of an electronic pressure controller located at the junction point between the columns. The minimum pressure step size is 0.1 psi, and 50 different set-point pressures can be used, each one producing a different pattern of peaks eluting from the column ensemble. Measured ensemble retention factors for a set of target compounds produce straight lines when plotted versus the ratio of the calculated holdup time of the first column in the ensemble to the total ensemble holdup time. A component band trajectory model is used to describe the effects of ensemble junction-point pressure on the elution patterns generated by the ensemble. Ensemble retention times predicted by the model are in good agreement with values obtained from chromatograms. The use of on-the-fly set-point pressure changes during a separation (selectivity programming) is demonstrated and used to improve the quality of the separation of a 19-component test mixture.


Asunto(s)
Cromatografía de Gases/instrumentación
6.
Anal Chem ; 71(22): 5199-205, 1999 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-10575966

RESUMEN

The development of lightweight, portable GC instrumentation is handicapped by the need for compressed carrier gas to drive the separation. The use of air as carrier gas eliminates the need for compressed gas tanks. If a vacuum pump is used to pull carrier gas and injected samples through the column, atmospheric pressure air can be used as carrier gas. Vacuum outlet operation also improves performance for high-speed separations by reducing detector dead time and by shifting optimal carrier gas velocity to higher values. Under vacuum outlet conditions using atmospheric pressure air as carrier gas, a 6-m-long, 0.25-mm-i.d. capillary column can generate approximately 12,500 theoretical plates, and a 12-m-long column can generate approximately 44,000 plates but with a 3-4-fold increase in separation time. The principal issues in column selection for high-speed GC with air as a carrier gas are efficiency and stability. Several bonded and nonbonded stationary phases were evaluated for use with air as carrier gas in the analysis of volatile organic compounds of interest in airmonitoring applications. These include dimethylpolysiloxane, 50% phenyl-50% methyl polysiloxane, 50% cycanopropylphenyl-50% methyl polysiloxane, trifluoropropyl polysiloxane, poly(ethylene glycol), and dicyanoallyl polysiloxane (nonbonded). The dimethyl polysiloxane and the trifluoropropyl polysiloxane columns showed good efficiency and no significant deterioration after 5 days of continuous operation with air as carrier gas. The 50% phenyl-50% methyl polysiloxane and the 50% cycanopropylphenyl-50% methyl polysiloxane columns showed poorer efficiency, and the poly(ethylene glycol) and dicyanoallyl polysiloxane columns showed excessive deterioration in air.


Asunto(s)
Cromatografía de Gases , Aire , Presión Atmosférica
7.
Anal Chem ; 71(11): 2123-9, 1999 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-21662747

RESUMEN

Fast temperature programming (20-50 °C/min) is used with relatively short separation columns to achieve high-speed separations of mixtures covering a wide boiling point range. A cryofocusing inlet is used to obtain narrow injection plugs. High-speed temperature-programmed chromatograms are evaluated by considering local peak capacity as a function of carbon number and boiling point for the normal alkanes in the range C(8)-C(19). The peak capacity generation rate (peaks per second) as a function of carbon number and the total cumulative peak capacity as a function of time are also considered for various column lengths and carrier gas flow rates. Column lengths in the range 3.6-25.4 m and average carrier gas velocity values in the range 50-200 cm/s are considered. For a 6.8-m-long, 0.25-mm-i.d. column operated at an average carrier gas velocity of about 100 cm/s and using a nominal programming rate of 50 °C/min, C(19) elutes in 178 s with a total peak capacity of 168 peaks. If the programming rate is reduced to 20 °C/min, the C(19) elution time more than doubles but the total peak capacity increases by only 20%. For a 25.4-m-long column using a nominal 50 °C/min programming rate, the C(19) retention time is 262 s with a peak capacity of 279 peaks. The use of average carrier gas flow rates greater than about 100 cm/s, which is common in isothermal high-speed GC, results in a considerable loss in total peak capacity with remarkably little reduction in analysis time.

8.
Environ Sci Technol ; 35(1): 163-9, 2001 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-11352005

RESUMEN

A pressure-tunable, series-coupled column ensemble was used with atmospheric pressure air as carrier gas for the vacuum-outlet GC analysis of 42 volatile and semivolatile organic compounds commonly encountered as indoor air pollutants. Separation strategies applicable to a field-portable instrument that will employ a dual-stage preconcentrator and a microsensor array as the detector were developed, where coelution of certain analytes can be tolerated. The capillary column ensemble consists of a 4.5-m segment of nonpolar dimethyl polysiloxane followed by a 7.5-m segment of polar trifluoropropylmethyl polysiloxane. Good long-term thermal stability of the column ensemble was observed for continuous operation in air at temperatures up to 210 degrees C. A computer-driven pressure controller at the column junction point is used to adjust vapor retention for specified sets of target compounds. The compounds were divided into two groups according to retention order, and high-speed analysis conditions were determined for the two groups individually as well as for the entire mixture. The earlier eluting group of 21 compounds was analyzed isothermally at 30 degrees C in about 160 s using a single, on-the-fly junction-point pressure change during the separation. The later eluting group of 21 compounds was analyzed in about 200 s with temperature programming and a constant (tuned) junction-point pressure. The entire mixture was analyzed in about 400 s using a two-step temperature program and a three-step pressure program, with minimal overlap in eluting peaks. Separations are adequate for analysis by a sensor array capable of discriminating among small groups of coeluting vapors on the basis of their response patterns.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Cromatografía de Gases/métodos , Compuestos Orgánicos/análisis , Temperatura , Vacio
9.
Anal Biochem ; 298(2): 327-36, 2001 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-11700990

RESUMEN

Arachidonic acid (AA) can be metabolized by cytochrome P450 (CYP) enzymes to many biologically active compounds including 5,6-, 8,9-, 11,12-, and 14,15-epoxyeicosatrienoic acids (EETs), their corresponding dihydroxyeicosatrienoic acids (DHETs), and 20-hydroxyeicosatetraenoic acid (20-HETE). These eicosanoids are potent regulators of vascular tone. We developed a liquid chromatography-electrospray ionization-mass spectrometry method to simultaneously determine 5,6-, 8,9-, 11,12-, and 14,15-EETs; 5,6-, 8,9-, 11,12-, and 14,15-DHETs; and 20-HETE. [2H8]EETs, [2H8]DHETs, and [2H2]20-HETE were used as internal standards. These compounds are readily separated on a C18 reverse-phase column using water:acetonitrile with 0.005% acetic acid as a mobile phase. The internal standards, [2H8]EETs, [2H8]DHETs, and [2H2]20-HETE, eluted slightly faster than the natural eicosanoids. The samples were ionized by electrospray with fragmentor voltage of 120 V and detected in a negative mode. The negative ion detection gave a lower background than the positive ion detection for these compounds. These eicosanoids exhibited high abundance of the ions corresponding to [M - 1]-. The m/z = 319, 337, and 319 ions were used for quantitation of EETs, DHETs, and 20-HETE, respectively. The detection limits using selected ion monitoring of these compounds are about 1 pg per injection. The position of functional groups and water content of mobile phase had a significant effect on the sensitivity of detection. Water content of 40% was found to give maximal sensitivity. The method was used to determine EETs, DHETs, and 20-HETE in bovine coronary artery endothelial cells, dog plasma, rat astrocytes, and rat kidney microsome samples.


Asunto(s)
Ácido Araquidónico/análisis , Sistema Enzimático del Citocromo P-450/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Animales , Astrocitos/química , Bovinos , Cromatografía Liquida/métodos , Perros , Endotelio Vascular/química , Riñón/química , Masculino , Microsomas/química , Miocardio/química , Ratas , Ratas Sprague-Dawley , Estándares de Referencia
10.