Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Clin Radiol ; 74(11): 896.e17-896.e22, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31466797

RESUMEN

AIM: To investigate the three-dimensional anatomy and shape of the proximal femur, comparing patients with secondary osteoarthritis (OA) due to mild developmental dysplasia of the hip (DDH) and primary hip OA. MATERIALS AND METHODS: This retrospective radiographic computed tomography (CT)-based study investigated proximal femoral anatomy in a consecutive series of 84 patients with secondary hip OA due to mild DDH (Crowe type I&II/Hartofilakidis A) compared to 84 patients with primary hip OA, matched for gender, age at surgery, and body mass index. RESULTS: Men with DDH showed higher neck shaft angles (127±5° vs. 123±4°; p<0.001), whereas women with DDH had a larger femoral head diameter (46±4 vs. 44±3 mm; p=0.002), smaller femoral offset (36±5 vs. 40±4 mm; p<0.001), decreased leg torsion (25±13° vs. 31±16°; p=0.037), and a higher neck shaft angle (128±7° vs. 123±4°; p<0.001) compared to primary OA patients. Similar patterns of the three-dimensional endosteal canal shape of the proximal femur, but a high inter-individual variability for femoral canal torsion at the meta-diaphyseal level were found for DDH and primary OA patients. CONCLUSION: Standard cementless stem designs are suitable to treat patients with secondary hip OA due to mild DDH; however, high patient variability and subtle anatomical differences in the proximal femur should be respected.


Asunto(s)
Fémur/patología , Luxación Congénita de la Cadera/patología , Osteoartritis de la Cadera/patología , Artroplastia de Reemplazo de Cadera , Femenino , Luxación Congénita de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Osteoartritis de la Cadera/cirugía , Estudios Retrospectivos , Caracteres Sexuales , Tomografía Computarizada por Rayos X
2.
Skeletal Radiol ; 46(6): 831-836, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28285449

RESUMEN

A number of previous studies have reported a potential risk of malignancy, particularly hematological malignancy, developing in patients receiving a metal-on-metal (MoM) hip replacement. We report a case of malignant lymphoma that arose in a patient who had an MoM hip arthroplasty complicated by development of a pseudotumour. The tumour was a B cell follicular lymphoma that involved lymph nodes and bone. Metal ions are known to have a genotoxic effect on lymphoid cells. Although epidemiological studies have not established that there is an increased risk of lymphoma associated with MoM implants, only a relatively short time period has elapsed since re-introduction of this type of implant and long-term follow-up of patients with MoM implants is indicated.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera/efectos adversos , Linfoma Folicular/diagnóstico por imagen , Prótesis Articulares de Metal sobre Metal/efectos adversos , Diseño de Prótesis , Femenino , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Linfoma Folicular/cirugía , Imagen por Resonancia Magnética , Persona de Mediana Edad , Radiografía , Ultrasonografía
3.
Bone Joint J ; 101-B(8): 902-909, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31362559

RESUMEN

AIMS: This study of patients with osteoarthritis (OA) of the hip aimed to: 1) characterize the contribution of the hip, spinopelvic complex, and lumbar spine when moving from the standing to the sitting position; 2) assess whether abnormal spinopelvic mobility is associated with worse symptoms; and 3) identify whether spinopelvic mobility can be predicted from static anatomical radiological parameters. PATIENTS AND METHODS: A total of 122 patients with end-stage OA of the hip awaiting total hip arthroplasty (THA) were prospectively studied. Patient-reported outcome measures (PROMs; Oxford Hip Score, Oswestry Disability Index, and Veterans RAND 12-Item Health Survey Score) and clinical data were collected. Sagittal spinopelvic mobility was calculated as the change from the standing to sitting position using the lumbar lordosis angle (LL), sacral slope (SS), pelvic tilt (PT), pelvic-femoral angle (PFA), and acetabular anteinclination (AI) from lateral radiographs. The interaction of the different parameters was assessed. PROMs were compared between patients with normal spinopelvic mobility (10° ≤ ∆PT ≤ 30°) or abnormal spinopelvic mobility (stiff: ∆PT < ± 10°; hypermobile: ∆PT > ± 30°). Multiple regression and receiver operating characteristic (ROC) curve analyses were used to test for possible predictors of spinopelvic mobility. RESULTS: Standing to sitting, the hip flexed by a mean of 57° (sd 17°), the pelvis tilted backwards by a mean of 20° (sd 12°), and the lumbar spine flexed by a mean of 20° (sd 14°); strong correlations were detected. There was no difference in PROMs between patients in the different spinopelvic mobility groups. Maximum hip flexion, standing PT, and standing AI were independent predictors of spinopelvic mobility (R2 = 0.42). The combined thresholds for standing was PT ≥ 13° and hip flexion ≥ 88° in the clinical examination, and had 90% sensitivity and 63% specificity of predicting spinopelvic stiffness, while SS ≥ 42° had 84% sensitivity and 67% specificity of predicting spinopelvic hypermobility. CONCLUSION: The hip, on average, accounts for three-quarters of the standing-to-sitting movement, but there is great variation. Abnormal spinopelvic mobility cannot be screened with PROMs. However, clinical and standing radiological features can predict spinopelvic mobility with good enough accuracy, allowing them to be used as reliable screening tools. Cite this article: Bone Joint J 2019;101-B:902-909.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera/fisiopatología , Osteoartritis de la Cadera/diagnóstico , Pelvis/fisiopatología , Rango del Movimiento Articular , Columna Vertebral/fisiopatología , Anciano , Femenino , Cadera/fisiopatología , Humanos , Región Lumbosacra/fisiopatología , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/fisiopatología , Osteoartritis de la Cadera/cirugía , Estudios Prospectivos , Sensibilidad y Especificidad
4.
Bone Joint J ; 101-B(5): 540-546, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31039002

RESUMEN

AIMS: Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied. PATIENTS AND METHODS: In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements. RESULTS: None of the MoMHRA patients showed clinically significant cardiac functional abnormality. The MoMHRA patients had larger indexed right and left end diastolic volumes (left ventricular (LV): 74 ml/m2vs 67 ml/m2, p = 0.045; right ventricular: 80 ml/m2vs 71 ml/m2, p = 0.02). There was a small decrease in T2 time in the MoMHRA patients (median 49 ms vs 54 ms; p = 0.0003). Higher metal ion levels were associated with larger LV volumes and with shorter T2 time. CONCLUSION: Although cardiac function is not clinically adversely affected in patients with well-functioning MoMHRA, modern imaging is able to demonstrate subtle changes in structure and function of the heart. As these changes correlate with systemic ion measurements, they may be consequences of wear debris deposition. Longer, longitudinal studies are necessary to determine whether cardiac function will become affected. Cite this article: Bone Joint J 2019;101-B:540-546.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Corazón/diagnóstico por imagen , Articulación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Imagen por Resonancia Cinemagnética/métodos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Adulto , Anciano , Estudios de Casos y Controles , Cromo/sangre , Cobalto/sangre , Femenino , Corazón/fisiopatología , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología
5.
Bone Joint J ; 100-B(10): 1280-1288, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30295537

RESUMEN

AIMS: This study aims to: determine the difference in pelvic position that occurs between surgery and radiographic, supine, postoperative assessment; examine how the difference in pelvic position influences subsequent component orientation; and establish whether differences in pelvic position, and thereafter component orientation, exist between total hip arthroplasties (THAs) performed in the supine versus the lateral decubitus positions. PATIENTS AND METHODS: The intra- and postoperative anteroposterior pelvic radiographs of 321 THAs were included; 167 were performed with the patient supine using the anterior approach and 154 were performed with the patient in the lateral decubitus using the posterior approach. The inclination and anteversion of the acetabular component was measured and the difference (Δ) between the intra- and postoperative radiographs was determined. The target zone was inclination/anteversion of 40°/20° (± 10°). Changes in the tilt, rotation, and obliquity of the pelvis on the intra- and postoperative radiographs were calculated from Δinclination/anteversion using the Levenberg-Marquardt algorithm. RESULTS: The mean postoperative inclination/anteversion was 40° (± 8°)/23° (± 9°) with Δinclination and/or Δanteversion > ± 10° in 74 (21%). Intraoperatively, the pelvis was anteriorly tilted by a mean of 4° (± 10°), internally rotated by a mean of 1° (± 10°) and adducted by a mean of 1° (± 5°). Having Δinclination and/or Δanteversion > ± 10° was associated with a 3.5 odds ratio of having the acetabular component outside the target zone. A greater proportion of THAs that were undertaken with the patient in the lateral decubitus position had Δinclination and/or Δanteversion > ± 10° (35.3%, 54/153) compared with those in the supine position (4.8%, 8/167; p < 0.001). A greater number of acetabular components were within the target zone in THAs undertaken with the patient in the supine position (72%, 120/167), compared with those in the lateral decubitus position (44%, 67/153; p < 0.001). Intraoperatively, the pelvis was more anteriorly tilted (p < 0.001) and more internally rotated (p = 0.04) when the patient was in the lateral decubitus position. CONCLUSION: The pelvic position is more reliable when the patient is in the supine position, leading to more consistent orientation of the acetabular component. Significant differences in pelvic tilt and rotation are seen with the patient in the lateral decubitus position. Cite this article: Bone Joint J 2018;100-B:1280-8.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Anteversión Ósea/prevención & control , Posicionamiento del Paciente/métodos , Huesos Pélvicos/fisiopatología , Complicaciones Posoperatorias/prevención & control , Posición Supina , Acetábulo , Anciano , Artroplastia de Reemplazo de Cadera/instrumentación , Anteversión Ósea/diagnóstico por imagen , Anteversión Ósea/etiología , Femenino , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Huesos Pélvicos/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Radiografía , Estudios Retrospectivos
6.
Bone Joint J ; 99-B(5): 614-622, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28455470

RESUMEN

AIMS: Advocates of debridement, antibiotics and implant retention (DAIR) in hip periprosthetic joint infection (PJI) argue that a procedure not disturbing a sound prosthesis-bone interface is likely to lead to better survival and functional outcome compared with revision. This case-control study aims were to compare outcome of DAIRs for infected primary total hip arthroplasty (THA) with outcomes following primary THA and two-stage revision of infected primary THAs. PATIENTS AND METHODS: We retrospectively reviewed all DAIRs, performed for confirmed infected primary hip arthropasty (n = 82) at out institution, between 1997 and 2013. Data recorded included full patient information and type of surgery. Outcome measures included complications, mortality, implant survivorship and functional outcome. Outcome was compared with two control groups matched for gender and age; a cohort of primary THAs (n = 120) and a cohort of two-stage revisions for infection (n = 66). RESULTS: Mean age at DAIR was 69 years (33 to 87) and mean follow-up was eight years (2 to 17; standard deviation (sd) 5). A total of 52 (63%) of DAIRs were for early PJI (less than six weeks). Greater success in the eradication of infection with DAIR was identified with early PJI, comprising an interval less than a week between onset of symptoms and exchange of modular components with the DAIR procedure. Eradication of infection, complications and re-operation rates were similar in the DAIR and two-stage revision groups. For hips with successful eradication of infection with DAIR, the five-year survival (98%; 95% confidence interval (CI) 94 to 100) was similar to the primary THA group (98%; 95% CI 95 to 100) (n = 43; p = 0.3). The DAIR group had inferior mean Oxford Hip Scores (OHS) (38; 12 to 48) compared with the primary THA group (42; 15 to 48) (p = 0.02) but a significantly better mean OHS compared with the two-stage revision group (31; 0 to 48) (p = 0.008). Patients who required only one DAIR for eradication of infection had a similar mean OHS (41; 20 to 48) to the primary THA group (p = 0.2). CONCLUSION: The DAIR procedure is associated with a similar complication rate and ability to eradicate infection as two-stage revision. This study emphasises the need for exchange of modular components for improved chances of eradication of infection. This is the first study showing that DAIR is better than a two-stage revision regarding functional outcome. Cite this article: Bone Joint J 2017;99-B:614-22.


Asunto(s)
Antibacterianos/uso terapéutico , Artroplastia de Reemplazo de Cadera/métodos , Desbridamiento/métodos , Prótesis de Cadera/efectos adversos , Infecciones Relacionadas con Prótesis/terapia , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Estudios de Casos y Controles , Terapia Combinada , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Reoperación/métodos , Estudios Retrospectivos , Resultado del Tratamiento
7.
Bone Joint J ; 98-B(11): 1463-1470, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27803221

RESUMEN

OBJECTIVES: A possible solution for the management of proximal femoral bone loss is a modular femoral endoprosthesis (EPR). Although the outcome of EPRs in tumour surgery has been well described, the outcome of their use in revision hip surgery has received less attention. The aim of this study was to describe the outcome of using EPR for non-neoplastic indications. METHODS: A retrospective review of 79 patients who underwent 80 EPRs for non-neoplastic indications was performed, including the rates of complication and survival and the mean Oxford Hip Scores (OHS), at a mean of five years post-operatively. The mean age at the time of surgery was 69 years (28 to 93) and the mean number of previous operations on the hip was 2.4 (0 to 17). The most common indications for EPR implantation were periprosthetic joint infection (PJI) (n = 40), periprosthetic fracture (n = 12) and failed osteosynthesis of a proximal femoral fracture or complex trauma (n = 11). RESULTS: Salvage was achieved in all patients. A total of 25 patients (25 EPRs, 31.6%) had a complication, the most common being infection (n = 9) and dislocation (n = 3). Further surgery was required for 18 EPRs (22%), nine of which were revision procedures. The five year survival of the EPR was 87% (95%CI: 76% to 98%). The mean OHS was 28 (4 to 48). Inferior survival and outcomes were seen in EPRs which were performed for the treatment of infection. However, the eradication of infection was achieved in 33 of the 40 (82.5%) which were undertaken for this indication. CONCLUSION: We recommend the continued use of proximal femoral EPRs for non-neoplastic indications, including PJI. Cite this article: Bone Joint J 2016;98-B:1463-70.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Fracturas del Fémur/cirugía , Estudios de Seguimiento , Fijación Interna de Fracturas , Fracturas no Consolidadas/cirugía , Prótesis de Cadera , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Fracturas Periprotésicas/cirugía , Falla de Prótesis , Infecciones Relacionadas con Prótesis/cirugía , Reoperación/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
8.
Virchows Arch ; 466(5): 595-601, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25687172

RESUMEN

A heavy neutrophil polymorph infiltrate [>5 per high-power field (HPF) after examination of at least 5 HPF by Musculoskeletal Infection Society (MSIS) criteria] is characteristically seen in peri-implant tissues of infected prosthetic hip and knee joints. We determined whether chloroacetate esterase (CAE) staining facilitated the identification of neutrophil polymorphs in peri-implant tissues in cases of hip and knee arthroplasty infection and reassessed MSIS criteria in the light of our findings. Frozen and paraffin sections of peri-prosthetic tissues of 76 cases of failed hip and knee arthroplasties classified as septic or aseptic loosening microbiologically were analysed histologically by both haematoxylin-eosin and CAE staining. The extent of the neutrophil polymorph infiltrate was determined semiquantitatively and correlated with the microbiological and clinical diagnosis. CAE staining facilitated identification of neutrophil polymorphs in arthroplasty tissues. All cases of aseptic loosening contained fewer than two neutrophil polymorphs per HPF. CAE staining showed that in some cases of septic loosening, fewer than five neutrophil polymorphs per HPF (on average) are present in peri-prosthetic tissues. The histological criterion of more than two neutrophil polymorphs per HPF showed increased sensitivity and accuracy for the diagnosis of septic loosening. CAE is a useful stain that facilitates the identification of neutrophil polymorphs in both frozen and paraffin sections of peri-implant tissues. CAE staining shows that some microbiologically confirmed cases of septic loosening contain relatively few neutrophil polymorphs, indicating that the MSIS histological criterion of more than five neutrophil polymorphs per HPF is too high an index figure for the diagnosis of all cases of hip and knee arthroplasty infection.


Asunto(s)
Infecciones Bacterianas/diagnóstico , Hidrolasas de Éster Carboxílico , Inmunohistoquímica/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Infecciones Bacterianas/etiología , Prótesis de Cadera , Humanos , Prótesis de la Rodilla , Coloración y Etiquetado
9.
Bone Joint J ; 97-B(1): 94-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25568420

RESUMEN

National Institute of Clinical Excellence guidelines state that cemented stems with an Orthopaedic Data Evaluation Panel (ODEP) rating of > 3B should be used for hemiarthroplasty when treating an intracapsular fracture of the femoral neck. These recommendations are based on studies in which most, if not all stems, did not hold such a rating. This case-control study compared the outcome of hemiarthroplasty using a cemented (Exeter) or uncemented (Corail) femoral stem. These are the two prostheses most commonly used in hip arthroplasty in the UK. Data were obtained from two centres; most patients had undergone hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients were matched for all factors that have been shown to influence mortality after an intracapsular fracture of the neck of the femur. Outcome measures included: complications, re-operations and mortality rates at two, seven, 30 and 365 days post-operatively. Comparable outcomes for the two stems were seen. There were more intra-operative complications in the uncemented group (13% vs 0%), but the cemented group had a greater mortality in the early post-operative period (n = 6). There was no overall difference in the rate of re-operation (5%) or death (365 days: 26%) between the two groups at any time post-operatively. This study therefore supports the use of both cemented and uncemented stems of proven design, with an ODEP rating of 10A, in patients with an intracapsular fracture of the neck of the femur.


Asunto(s)
Cementos para Huesos/uso terapéutico , Cementación/métodos , Fracturas del Cuello Femoral/cirugía , Hemiartroplastia/métodos , Fracturas Periprotésicas/epidemiología , Factores de Edad , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Cementación/efectos adversos , Femenino , Fracturas del Cuello Femoral/diagnóstico por imagen , Fracturas del Cuello Femoral/mortalidad , Estudios de Seguimiento , Hemiartroplastia/efectos adversos , Prótesis de Cadera , Humanos , Modelos Lineales , Masculino , Análisis Multivariante , Fracturas Periprotésicas/diagnóstico por imagen , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/fisiopatología , Radiografía , Estudios Retrospectivos , Medición de Riesgo , Factores Sexuales , Estadísticas no Paramétricas , Tasa de Supervivencia , Resultado del Tratamiento
10.
Bone Joint J ; 97-B(2): 164-72, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25628277

RESUMEN

We assessed the orientation of the acetabular component in 1070 primary total hip arthroplasties with hard-on-soft, small diameter bearings, aiming to determine the size and site of the target zone that optimises outcome. Outcome measures included complications, dislocations, revisions and ΔOHS (the difference between the Oxford Hip Scores pre-operatively and five years post-operatively). A wide scatter of orientation was observed (2sd 15°). Placing the component within Lewinnek's zone was not associated withimproved outcome. Of the different zone sizes tested (± 5°, ± 10° and ± 15°), only ± 15° was associated with a decreased rate of dislocation. The dislocation rate with acetabular components inside an inclination/anteversion zone of 40°/15° ± 15° was four times lower than those outside. The only zone size associated with statistically significant and clinically important improvement in OHS was ± 5°. The best outcomes (ΔOHS > 26) were achieved with a 45°/25° ± 5° zone. This study demonstrated that with traditional technology surgeons can only reliably achieve a target zone of ±15°. As the optimal zone to diminish the risk of dislocation is also ±15°, surgeons should be able to achieve this. This is the first study to demonstrate that optimal orientation of the acetabular component improves the functional outcome. However, the target zone is small (± 5°) and cannot, with current technology, be consistently achieved.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Acetábulo , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Diseño de Prótesis , Resultado del Tratamiento
11.
Bone Joint J ; 96-B(7): 876-83, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24986939

RESUMEN

The orientation of the acetabular component is influenced not only by the orientation at which the surgeon implants the component, but also the orientation of the pelvis at the time of implantation. Hence, the orientation of the pelvis at set-up and its movement during the operation, are important. During 67 hip replacements, using a validated photogrammetric technique, we measured how three surgeons orientated the patient's pelvis, how much the pelvis moved during surgery, and what effect these had on the final orientation of the acetabular component. Pelvic orientation at set-up, varied widely (mean (± 2, standard deviation (sd))): tilt 8° (2sd ± 32), obliquity -4° (2sd ± 12), rotation -8° (2sd ± 14). Significant differences in pelvic positioning were detected between surgeons (p < 0.001). The mean angular movement of the pelvis between set-up and component implantation was 9° (sd 6). Factors influencing pelvic movement included surgeon, approach (posterior > lateral), procedure (hip resurfacing > total hip replacement) and type of support (p < 0.001). Although, on average, surgeons achieved their desired acetabular component orientation, there was considerable variability (2sd ± 16) in component orientation. We conclude that inconsistency in positioning the patient at set-up and movement of the pelvis during the operation account for much of the variation in acetabular component orientation. Improved methods of positioning and holding the pelvis are required.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Posicionamiento del Paciente , Acetábulo/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pelvis/fisiología , Fotogrametría , Estudios Prospectivos , Rotación
12.
Bone Joint J ; 96-B(10): 1290-7, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25274911

RESUMEN

There is great variability in acetabular component orientation following hip replacement. The aims of this study were to compare the component orientation at impaction with the orientation measured on post-operative radiographs and identify factors that influence the difference between the two. A total of 67 hip replacements (52 total hip replacements and 15 hip resurfacings) were prospectively studied. Intra-operatively, the orientation of the acetabular component after impaction relative to the operating table was measured using a validated stereo-photogrammetry protocol. Post-operatively, the radiographic orientation was measured; the mean inclination/anteversion was 43° (sd 6°)/ 19° (sd 7°). A simulated radiographic orientation was calculated based on how the orientation would have appeared had an on-table radiograph been taken intra-operatively. The mean difference between radiographic and intra-operative inclination/anteversion was 5° (sd 5°)/ -8° (sd 8°). The mean difference between simulated radiographic and intra-operative inclination/anteversion, which quantifies the effect of the different way acetabular orientation is measured, was 3°/-6° (sd 2°). The mean difference between radiographic and simulated radiographic orientation inclination/anteversion, which is a manifestation of the change in pelvic position between component impaction and radiograph, was 1°/-2° (sd 7°). This study demonstrated that in order to achieve a specific radiographic orientation target, surgeons should implant the acetabular component 5° less inclined and 8° more anteverted than their target. Great variability (2 sd about ± 15°) in the post-operative radiographic cup orientation was seen. The two equally contributing causes for this are variability in the orientation at which the cup is implanted, and the change in pelvic position between impaction and post-operative radiograph.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Luxación de la Cadera/prevención & control , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Cirugía Asistida por Computador/métodos , Acetábulo/diagnóstico por imagen , Adulto , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Luxación de la Cadera/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Periodo Posoperatorio , Estudios Prospectivos , Diseño de Prótesis , Radiografía
13.
Maturitas ; 77(2): 185-90, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24289896

RESUMEN

The burden of revision total hip replacement (THR) surgery is increasing. With an increasing life expectancy and younger age of primary surgery this trend is set to continue. There are few data on the long-term outcome of revision THR. This retrospective study of 1176 consecutive revision THRs with a minimum 10-year follow-up from a University Teaching Hospital was undertaken to review implant survival and patient reported outcomes. Mean follow-up was 11 years with implant survival at 10 years of 82% (CI: 80-85). Implant survival varied between 58% (unexplained pain) to 84% (aseptic loosening) depending on the indication for revision surgery. Positive predictors of survival were age greater than 70 at the time of surgery (p=0.011), revision for aseptic loosening (p<0.01) and revision of both components or just the acetabular component (p<0.01). At the last review, mean Oxford Hip Score (OHS) was 34 (SD: 11.3) and 92% of the living patients with unrevised hips were satisfied with the outcome of revision surgery. This long term study has demonstrated that positive predictors of survival and outcome of revision THR surgery are age greater than 70 years, revision for aseptic loosening and component revision. This should aid surgeons in their counselling of patients prior to surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente/estadística & datos numéricos , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Adulto Joven
14.
J Bone Joint Surg Br ; 94(9): 1180-6, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22933488

RESUMEN

Recent events have highlighted the importance of implant design for survival and wear-related complications following metal-on-metal hip resurfacing arthroplasty. The mid-term survival of the most widely used implant, the Birmingham Hip Resurfacing (BHR), has been described by its designers. The aim of this study was to report the ten-year survival and patient-reported functional outcome of the BHR from an independent centre. In this cohort of 554 patients (646 BHRs) with a mean age of 51.9 years (16.5 to 81.5) followed for a mean of eight years (1 to 12), the survival and patient-reported functional outcome depended on gender and the size of the implant. In female hips (n = 267) the ten-year survival was 74% (95% confidence interval (CI) 83 to 91), the ten-year revision rate for pseudotumour was 7%, the mean Oxford hip score (OHS) was 43 (SD 8) and the mean UCLA activity score was 6.4 (SD 2). In male hips (n = 379) the ten-year survival was 95% (95% CI 92.0 to 97.4), the ten-year revision rate for pseudotumour was 1.7%, the mean OHS was 45 (SD 6) and the mean UCLA score was 7.6 (SD 2). In the most demanding subgroup, comprising male patients aged < 50 years treated for primary osteoarthritis, the survival was 99% (95% CI 97 to 100). This study supports the ongoing use of resurfacing in young active men, who are a subgroup of patients who tend to have problems with conventional THR. In contrast, the results in women have been poor and we do not recommend metal-on-metal resurfacing in women. Continuous follow-up is recommended because of the increasing incidence of pseudotumour with the passage of time.


Asunto(s)
Artroplastia de Reemplazo de Cadera/mortalidad , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Análisis de Falla de Equipo/estadística & datos numéricos , Granuloma de Células Plasmáticas/epidemiología , Adolescente , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , Causalidad , Comorbilidad , Femenino , Pinzamiento Femoroacetabular/epidemiología , Fracturas de Cadera/epidemiología , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación/mortalidad , Distribución por Sexo , Factores Sexuales , Propiedades de Superficie , Adulto Joven
15.
J Bone Joint Surg Br ; 92(11): 1527-34, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21037347

RESUMEN

Pseudotumour is a rare but important complication of metal-on-metal hip resurfacing that occurs much more commonly in women than in men. We examined the relationship between head-neck ratio (HNR) and pseudotumour formation in 18 resurfaced hips (18 patients) revised for pseudotumour and 42 asymptomatic control resurfaced hips (42 patients). Patients in whom pseudotumour formation had occurred had higher pre-operative HNR than the control patients (mean 1.37 (sd 0.10) vs mean 1.30 (sd 0.08) p = 0.001). At operation the patients with pseudotumours had a greater reduction in the size of their femoral heads (p = 0.035) and subsequently had greater neck narrowing (mean 10.1% (sd 7.2) vs mean 3.8% (sd 3.2) p < 0.001). No female patient with a pre-operative HNR ≤ 1.3 developed a pseudotumour. We suggest that reducing the size of the femoral head, made possible by a high pre-operative HNR, increases the risk of impingement and edge loading, and may contribute to high wear and pseudotumour formation. As the incidence of pseudotumour is low in men, it appears safe to perform resurfacing in men. However, this study suggests that it is also reasonable to resurface in women with a pre-operative HNR ≤ 1.3.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Enfermedades Óseas/etiología , Cabeza Femoral/patología , Cuello Femoral/patología , Granuloma de Células Plasmáticas/etiología , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Enfermedades Óseas/fisiopatología , Métodos Epidemiológicos , Femenino , Cabeza Femoral/cirugía , Granuloma de Células Plasmáticas/fisiopatología , Articulación de la Cadera/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Reoperación , Factores Sexuales
16.
J Bone Joint Surg Br ; 92(8): 1072-8, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20675749

RESUMEN

Pseudotumours are a rare complication of hip resurfacing. They are thought to be a response to metal debris which may be caused by edge loading due to poor orientation of the acetabular component. Our aim was to determine the optimal acetabular orientation to minimise the risk of pseudotumour formation. We matched 31 hip resurfacings revised for pseudotumour formation with 58 controls who had a satisfactory outcome from this procedure. The radiographic inclination and anteversion angles of the acetabular component were measured on anteroposterior radiographs of the pelvis using Einzel-Bild-Roentgen-Analyse software. The mean inclination angle (47 degrees, 10 degrees to 81 degrees) and anteversion angle (14 degrees, 4 degrees to 34 degrees) of the pseudotumour cases were the same (p = 0.8, p = 0.2) as the controls, 46 degrees (29 degrees to 60 degrees) and 16 degrees (4 degrees to 30 degrees) respectively, but the variation was greater. Assuming an accuracy of implantation of +/- 10 degrees about a target position, the optimal radiographic position was found to be approximately 45 degrees of inclination and 20 degrees of anteversion. The incidence of pseudotumours inside the zone was four times lower (p = 0.007) than outside the zone. In order to minimise the risk of pseudotumour formation we recommend that surgeons implant the acetabular component at an inclination of 45 degrees (+/- 10) and anteversion of 20 degrees (+/- 10) on post-operative radiographs. Because of differences between the radiographic and the operative angles, this may be best achieved by aiming for an inclination of 40 degrees and an anteversion of 25 degrees.


Asunto(s)
Acetábulo/patología , Artroplastia de Reemplazo de Cadera/efectos adversos , Granuloma de Células Plasmáticas/etiología , Acetábulo/diagnóstico por imagen , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Granuloma de Células Plasmáticas/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Orientación , Radiografía , Reoperación
17.
J Bone Joint Surg Br ; 91(8): 1019-24, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19651827

RESUMEN

Inflammatory pseudotumours occasionally occur after metal-on-metal hip resurfacing and often lead to revision. Our aim was to determine the severity of this complication by assessing the outcome of revision in these circumstances and by comparing this with the outcome of other metal-on-metal hip resurfacing revisions as well as that of matched primary total hip replacements. We identified 53 hips which had undergone metal-on-metal hip resurfacing and required revision at a mean of 1.59 years (0.01 to 6.69) after operation. Of these, 16 were revised for pseudotumours, 21 for fracture and 16 for other reasons. These were matched by age, gender and diagnosis with 103 patients undergoing primary total hip replacement with the Exeter implant. At a mean follow-up of three years (0.8 to 7.2) the outcome of metal-on-metal hip resurfacing revision for pseudotumour was poor with a mean Oxford hip score of 20.9 (sd 9.3) and was significantly worse (p < 0.001) than the outcome for fracture with a mean Oxford hip score of 40.2 (sd 9.2) or that for other causes with a mean Oxford hip score of 37.8 (sd 9.4). The clinical outcome of revision for pseudotumour was also significantly worse (p < 0.001) than the outcome of matched primary total hip replacements. By contrast, the outcome for fracture and other causes was not significantly different from that of matched primary total hip replacements (p = 0.065). After revision for pseudotumour there were three cases of recurrent dislocation, three of palsy of the femoral nerve, one of stenosis of the femoral artery and two of loosening of the component. Five hips required further revision. In three of these there was evidence of recurrent pseudotumour, and one is currently awaiting further revision. The incidence of major complications after revision for pseudotumour (50%) was significantly higher (p = 0.018) than that after revision for other causes (14%). The outcome of revision for pseudotumour is poor and consideration should be given to early revision to limit the extent of the soft-tissue destruction. The outcome of resurfacing revision for other causes is good.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Epífisis/cirugía , Fracturas del Fémur/cirugía , Necrosis de la Cabeza Femoral/cirugía , Granuloma de Células Plasmáticas/cirugía , Osteoartritis de la Cadera/cirugía , Adulto , Anciano , Epífisis/fisiopatología , Femenino , Fracturas del Fémur/fisiopatología , Necrosis de la Cabeza Femoral/fisiopatología , Granuloma de Células Plasmáticas/fisiopatología , Humanos , Masculino , Metales , Persona de Mediana Edad , Osteoartritis de la Cadera/fisiopatología , Pronóstico , Diseño de Prótesis , Falla de Prótesis , Reoperación/estadística & datos numéricos , Índice de Severidad de la Enfermedad , Adulto Joven
18.
Development ; 127(24): 5355-65, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11076757

RESUMEN

Overexpression of Hoxa2 in the chick first branchial arch leads to a transformation of first arch cartilages, such as Meckel's and the quadrate, into second arch elements, such as the tongue skeleton. These duplicated elements are fused to the original in a similar manner to that seen in the Hoxa2 knockout, where the reverse transformation of second to first arch morphology is observed. This confirms the role of Hoxa2 as a selector gene specifying second arch fate. When first arch neural crest alone is targeted, first arch elements are lost, but the Hoxa2-expressing crest is unable to develop into second arch elements. This is not due to Hoxa2 preventing differentiation of cartilages. Upregulation of a second arch marker in the first arch, and homeotic transformation of cartilage elements is only produced after global Hoxa2 overexpression in the crest and the surrounding tissue. Thus, although the neural crest appears to contain some patterning information, it needs to read cues from the environment to form a coordinated pattern. Hoxa2 appears to exert its effect during differentiation of the cartilage elements in the branchial arches, rather than during crest migration, implying that pattern is determined quite late in development.


Asunto(s)
Región Branquial/embriología , Genes Homeobox , Animales , Tipificación del Cuerpo/genética , Región Branquial/metabolismo , Cartílago/embriología , Cartílago/metabolismo , Embrión de Pollo , Regulación del Desarrollo de la Expresión Génica , Marcación de Gen , Hibridación in Situ , Músculo Esquelético/embriología , Músculo Esquelético/metabolismo , Lengua/embriología , Lengua/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA