Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 149(25): 1938-1948, 2024 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-38804148

RESUMEN

BACKGROUND: Ascending aorta dilation and aortic valve degeneration are common complications in patients with bicuspid aortic valve. Several retrospective studies have suggested the benefit of statins in reducing these complications. This study aimed to determine whether atorvastatin treatment is effective in reducing the growth of aortic diameters in bicuspid aortic valve and if it slows the progression of valve calcification. METHODS: In a randomized clinical trial, 220 patients with bicuspid aortic valve (43 women; 46±13 years of age) were included and treated with either 20 mg of atorvastatin per day or placebo for 3 years. Inclusion criteria were ≥18 years of age, nonsevere valvular dysfunction, nonsevere valve calcification, and ascending aorta diameter ≤50 mm. Computed tomography and echocardiography studies were performed at baseline and after 3 years of treatment. RESULTS: During follow-up, 28 patients (12.7%) discontinued medical treatment (15 on atorvastatin and 13 taking placebo). Thus, 192 patients completed the 36 months of treatment. Low-density lipoprotein cholesterol levels decreased significantly in the atorvastatin group (median [interquartile range], -30 mg/dL [-51.65 to -1.75 mg/dL] versus 6 mg/dL [-4, 22.5 mg/dL]; P<0.001). The maximum ascending aorta diameter increased with no differences between groups: 0.65 mm (95% CI, 0.45-0.85) in the atorvastatin group and 0.74 mm (95% CI, 0.45-1.04) in the placebo group (P=0.613). Similarly, no significant differences were found for the progression of the aortic valve calcium score (P=0.167) or valvular dysfunction. CONCLUSIONS: Among patients with bicuspid aortic valve without severe valvular dysfunction, atorvastatin treatment was not effective in reducing the progression of ascending aorta dilation and aortic valve calcification during 3 years of treatment despite a significant reduction in low-density lipoprotein cholesterol levels. REGISTRATION: URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2015-001808-57. URL: https://www.clinicaltrials.gov; Unique identifier: NCT02679261.


Asunto(s)
Válvula Aórtica , Atorvastatina , Enfermedad de la Válvula Aórtica Bicúspide , Calcinosis , Progresión de la Enfermedad , Enfermedades de las Válvulas Cardíacas , Inhibidores de Hidroximetilglutaril-CoA Reductasas , Humanos , Atorvastatina/uso terapéutico , Femenino , Masculino , Persona de Mediana Edad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/anomalías , Válvula Aórtica/efectos de los fármacos , Calcinosis/tratamiento farmacológico , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/tratamiento farmacológico , Enfermedades de las Válvulas Cardíacas/tratamiento farmacológico , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/patología , Adulto , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Dilatación Patológica/tratamiento farmacológico , Estudios de Seguimiento , Método Doble Ciego , Resultado del Tratamiento , Aorta/diagnóstico por imagen , Aorta/patología , Aorta/efectos de los fármacos , Enfermedad de la Válvula Aórtica/tratamiento farmacológico , Estenosis de la Válvula Aórtica
2.
Eur Radiol ; 34(8): 5190-5200, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38183450

RESUMEN

OBJECTIVES: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus. METHODS: Patients with chronic non-thrombosed or partially thrombosed FLs in the descending aorta after an aortic dissection underwent computed tomography angiography, cardiovascular magnetic resonance (CMR) angiography, and a 4D flow CMR study. A comprehensive quantitative analysis was performed to test the association between FL thrombus presence and extent (percentage of FL with thrombus) and FL anatomy (diameter, entry tear location and size), fluid dynamics (inflow, rotational flow, wall shear stress, kinetic energy, and flow acceleration and stasis), and biomechanics (pulse wave velocity). RESULTS: Sixty-eight patients were included. In multivariate logistic regression FL kinetic energy (p = 0.038) discriminated the 33 patients with partial FL thrombosis from the 35 patients with no thrombosis. Similarly, in separated multivariate linear correlations kinetic energy (p = 0.006) and FL inflow (p = 0.002) were independently related to the extent of the thrombus. FL vortexes, flow acceleration and stasis, wall shear stress, and pulse wave velocity showed limited associations with thrombus presence and extent. CONCLUSION: In patients with chronic descending aorta dissection, false lumen kinetic energy is related to the presence and extent of false lumen thrombus. CLINICAL RELEVANCE STATEMENT: In patients with chronic aortic dissection of the descending aorta, false lumen hemodynamic parameters are closely linked with the presence and extent of false lumen thrombosis, and these non-invasive measures might be important in patient management. KEY POINTS: • Partial false lumen thrombosis has been associated with aortic growth in patients with chronic descending aortic dissection; therefore, the identification of prothrombotic flow conditions is desirable. • The presence of partial false lumen thrombosis as well as its extent was related with false lumen kinetic energy. • The assessment of false lumen hemodynamics may be important in the management of patients with chronic aortic dissection of the descending aorta.


Asunto(s)
Aorta Torácica , Disección Aórtica , Hemodinámica , Trombosis , Humanos , Masculino , Femenino , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Disección Aórtica/complicaciones , Persona de Mediana Edad , Estudios Retrospectivos , Trombosis/diagnóstico por imagen , Trombosis/fisiopatología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Angiografía por Tomografía Computarizada/métodos , Enfermedad Crónica , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/complicaciones , Angiografía por Resonancia Magnética/métodos
3.
J Cardiovasc Magn Reson ; 26(1): 100992, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38211655

RESUMEN

BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.


Asunto(s)
Aorta Torácica , Enfermedades de la Aorta , Medios de Contraste , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Aorta Torácica/diagnóstico por imagen , Anciano , Medios de Contraste/administración & dosificación , Enfermedades de la Aorta/diagnóstico por imagen , Técnicas de Imagen Sincronizada Respiratorias , Adulto , Factores de Tiempo , Interpretación de Imagen Asistida por Computador , Técnicas de Imagen Sincronizada Cardíacas
4.
Am J Physiol Heart Circ Physiol ; 325(1): H1-H29, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37000606

RESUMEN

Arterial pulse waves (PWs) such as blood pressure and photoplethysmogram (PPG) signals contain a wealth of information on the cardiovascular (CV) system that can be exploited to assess vascular age and identify individuals at elevated CV risk. We review the possibilities, limitations, complementarity, and differences of reduced-order, biophysical models of arterial PW propagation, as well as theoretical and empirical methods for analyzing PW signals and extracting clinically relevant information for vascular age assessment. We provide detailed mathematical derivations of these models and theoretical methods, showing how they are related to each other. Finally, we outline directions for future research to realize the potential of modeling and analysis of PW signals for accurate assessment of vascular age in both the clinic and in daily life.


Asunto(s)
Arterias , Fotopletismografía , Humanos , Arterias/fisiología , Fotopletismografía/métodos , Análisis de la Onda del Pulso , Modelos Cardiovasculares
5.
J Ultrasound Med ; 42(10): 2183-2213, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37148467

RESUMEN

Non-invasive ultrasound (US) imaging enables the assessment of the properties of superficial blood vessels. Various modes can be used for vascular characteristics analysis, ranging from radiofrequency (RF) data, Doppler- and standard B/M-mode imaging, to more recent ultra-high frequency and ultrafast techniques. The aim of the present work was to provide an overview of the current state-of-the-art non-invasive US technologies and corresponding vascular ageing characteristics from a technological perspective. Following an introduction about the basic concepts of the US technique, the characteristics considered in this review are clustered into: 1) vessel wall structure; 2) dynamic elastic properties, and 3) reactive vessel properties. The overview shows that ultrasound is a versatile, non-invasive, and safe imaging technique that can be adopted for obtaining information about function, structure, and reactivity in superficial arteries. The most suitable setting for a specific application must be selected according to spatial and temporal resolution requirements. The usefulness of standardization in the validation process and performance metric adoption emerges. Computer-based techniques should always be preferred to manual measures, as long as the algorithms and learning procedures are transparent and well described, and the performance leads to better results. Identification of a minimal clinically important difference is a crucial point for drawing conclusions regarding robustness of the techniques and for the translation into practice of any biomarker.


Asunto(s)
Arterias , Ultrasonografía Doppler , Humanos , Ultrasonografía/métodos , Arterias/diagnóstico por imagen , Algoritmos , Tecnología
6.
Eur Radiol ; 32(3): 1997-2009, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34655311

RESUMEN

OBJECTIVES: Manual assessment of aortic diameters on double-oblique reformatted computed tomography angiograms (CTA) is considered the current standard, although the reproducibility for growth rates has not been reported. Deformable registration of CTA has been proposed to provide 3D aortic diameters and growth maps, but validation is lacking. This study aimed to quantify accuracy and inter-observer reproducibility of registration-based and manual assessment of aortic diameters and growth rates. METHODS: Forty patients with ≥ 2 CTA acquired at least 6 months apart were included. Aortic diameters and growth rate were obtained in the aortic root and the entire thoracic aorta using deformable image registration by two independent observers, and compared with the current standard at typical anatomical landmarks. RESULTS: Compared with manual assessment, the registration-based technique presented low bias (0.46 mm), excellent agreement (ICC = 0.99), and similar inter-observer reproducibility (ICC = 0.99 for both) for aortic diameters; and low bias (0.10 mm/year), good agreement (ICC = 0.82), and much higher inter-observer reproducibility for growth rates (root: ICC = 0.96 vs 0.68; thoracic aorta: ICC = 0.96 vs 0.80). Registration-based growth rate reproducibility over a 6-month-long follow-up was similar to that obtained by manual assessment after 2.7 years (LoA = [- 0.01, 0.33] vs [- 0.13, 0.21] mm/year, respectively). Mapping of diameter and growth rate was highly reproducible (ICC > 0.9) in the whole thoracic aorta. CONCLUSIONS: Registration-based assessment of aortic dilation on CTA is accurate and substantially more reproducible than the current standard, even at follow-up as short as 6 months, and provides robust 3D mapping of aortic diameters and growth rates beyond the pre-established anatomic landmarks. KEY POINTS: • Registration-based semi-automatic assessment of progressive aortic dilation on CTA is accurate and substantially more reproducible than the current standard. • The registration-based technique allows robust growth rate assessment at follow-up as short as 6 months, with a similar reproducibility to that obtained by manual assessment at around 3 years. • The use of image registration provides robust 3D mapping of aortic diameters and growth rates beyond the pre-established anatomic landmarks.


Asunto(s)
Angiografía por Tomografía Computarizada , Tomografía Computarizada por Rayos X , Aorta , Aorta Torácica/diagnóstico por imagen , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
7.
Eur Radiol ; 32(10): 7117-7127, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35976395

RESUMEN

OBJECTIVE: Three-dimensional (3D) time-resolved phase-contrast cardiac magnetic resonance (4D flow CMR) allows for unparalleled quantification of blood velocity. Despite established potential in aortic diseases, the analysis is time-consuming and requires expert knowledge, hindering clinical application. The present research aimed to develop and test a fully automatic machine learning-based pipeline for aortic 4D flow CMR analysis. METHODS: Four hundred and four subjects were prospectively included. Ground-truth to train the algorithms was generated by experts. The cohort was divided into training (323 patients) and testing (81) sets and used to train and test a 3D nnU-Net for segmentation and a Deep Q-Network algorithm for landmark detection. In-plane (IRF) and through-plane (SFRR) rotational flow descriptors and axial and circumferential wall shear stress (WSS) were computed at ten planes covering the ascending aorta and arch. RESULTS: Automatic aortic segmentation resulted in a median Dice score (DS) of 0.949 and average symmetric surface distance of 0.839 (0.632-1.071) mm, comparable with the state of the art. Aortic landmarks were located with a precision comparable with experts in the sinotubular junction and first and third supra-aortic vessels (p = 0.513, 0.592 and 0.905, respectively) but with lower precision in the pulmonary bifurcation (p = 0.028), resulting in precise localisation of analysis planes. Automatic flow assessment showed excellent (ICC > 0.9) agreement with manual quantification of SFRR and good-to-excellent agreement (ICC > 0.75) in the measurement of IRF and axial and circumferential WSS. CONCLUSION: Fully automatic analysis of complex aortic flow dynamics from 4D flow CMR is feasible. Its implementation could foster the clinical use of 4D flow CMR. KEY POINTS: • 4D flow CMR allows for unparalleled aortic blood flow analysis but requires aortic segmentation and anatomical landmark identification, which are time-consuming, limiting 4D flow CMR widespread use. • A fully automatic machine learning pipeline for aortic 4D flow CMR analysis was trained with data of 323 patients and tested in 81 patients, ensuring a balanced distribution of aneurysm aetiologies. • Automatic assessment of complex flow characteristics such as rotational flow and wall shear stress showed good-to-excellent agreement with manual quantification.


Asunto(s)
Aorta , Imagen por Resonancia Magnética , Aorta/diagnóstico por imagen , Válvula Aórtica , Velocidad del Flujo Sanguíneo , Humanos , Aprendizaje Automático , Imagen por Resonancia Magnética/métodos
8.
J Cardiovasc Magn Reson ; 24(1): 20, 2022 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-35346239

RESUMEN

BACKGROUND: Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. METHODS: Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. RESULTS: Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. CONCLUSIONS: In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Rigidez Vascular , Disección Aórtica/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso
9.
Eur Radiol ; 31(12): 9262-9272, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33977309

RESUMEN

OBJECTIVE: Bicuspid aortic valve (BAV), the most common congenital valve defect, is associated with increased risk of aortic dilation and related complications; however, current risk assessment is not effective. Most of BAV have three leaflets with a fusion between two of them of variable length. This study aimed to ascertain whether the extent of leaflet fusion (often called raphe) is related to aortic dilation and flow abnormalities in BAV with no significant valvular dysfunction. METHODS: One hundred and twenty BAV patients with no significant valvular dysfunction or history of surgical repair or aortic valve replacement were consecutively and prospectively enrolled (September 2014-October 2018). Cardiac magnetic resonance protocol included a 4D flow sequence for haemodynamic assessment. Moreover, a stack of double-oblique cine images of the aortic valve were used to quantify fusion length (in systole) and leaflet length (diastole). Inter- and intra-observer reproducibility was tested in 30 randomly selected patients. RESULTS: Aortic valve leaflet fusion was measurable in 112 of 120 (93%) cases with good reproducibility (ICC = 0.826). Fusion length varied greatly (range: 2.3-15.4 mm; mean: 7.8 ± 3.2 mm). After correction for demographic and clinical conditions, fusion length was independently associated with diameter and z-score at the sinus of Valsalva (p = 0.002 and p = 0.002, respectively) and ascending aorta (p = 0.028 and p = 0.046). Fusion length was positively related to flow asymmetry, vortices and circumferential wall shear stress, thereby possibly providing a pathophysiological link with aortic dilation. CONCLUSIONS: Aortic valve fusion length is related to aortic dilation and flow abnormalities in BAV patients. KEY POINTS: • The length of the fusion between leaflets in non-dysfunctional bicuspid aortic valves varies substantially and can be reliably measured by cine CMR. • Aortic valve leaflet fusion length is independently related to aortic sinus and ascending aorta diameter. • Increased flow asymmetry, circumferential wall shear stress and presence of vortices are positively related to aortic valve leaflet fusion length.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Válvula Aórtica/diagnóstico por imagen , Dilatación , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Reproducibilidad de los Resultados
10.
Arterioscler Thromb Vasc Biol ; 40(1): e10-e20, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31801375

RESUMEN

OBJECTIVE: To assess the relationship between regional wall shear stress (WSS) and oscillatory shear index (OSI) and aortic dilation in patients with bicuspid aortic valve (BAV). Approach and Results: Forty-six consecutive patients with BAV (63% with right-left-coronary-cusp fusion, aortic diameter ≤ 45 mm and no severe valvular disease) and 44 healthy volunteers were studied by time-resolved 3-dimensional phase-contrast magnetic resonance imaging. WSS and OSI were quantified at different levels of the ascending aorta and the aortic arch, and regional WSS and OSI maps were obtained. Seventy percent of BAV had ascending aorta dilation. Compared with healthy volunteers, patients with BAV had increased WSS and decreased OSI in most of the ascending aorta and the aortic arch. In both BAV and healthy volunteers, regions of high WSS matched regions of low OSI and vice versa. No regions of both low WSS and high OSI were identified in BAV compared with healthy volunteers. Patients with BAV with dilated compared with nondilated aorta presented low and oscillatory WSS in the aortic arch, but not in the ascending aorta where dilation is more prevalent. Furthermore, no regions of concomitant low WSS and high OSI were identified when BAV were compared according to leaflet fusion pattern, despite the well-known differences in regional dilation prevalence. CONCLUSIONS: Regions with low WSS and high OSI do not match those with the highest prevalence of dilation in patients with BAV, thus providing no evidence to support the low and oscillatory shear stress theory in the pathogenesis of proximal aorta dilation in the presence of BAV.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética/métodos , Flujo Sanguíneo Regional/fisiología , Resistencia al Corte/fisiología , Adulto , Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/fisiopatología , Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Estrés Mecánico
11.
Eur J Vasc Endovasc Surg ; 62(5): 797-807, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34511317

RESUMEN

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) is widely used for the treatment of patients with blunt traumatic thoracic aortic injury (BTAI). However, aortic haemodynamic and biomechanical implications of this intervention are poorly investigated. This study aimed to assess whether patients treated by TEVAR following BTAI have thoracic aortic abnormalities in geometry, stiffness, and haemodynamics. METHODS: Patients with BTAI treated by TEVAR at Vall d'Hebron Hospital between 1999 and 2019 were compared with propensity score matched healthy volunteers (HVs). All subjects underwent cardiovascular magnetic resonance (CMR) comprising a 4D flow CMR sequence. Spatially resolved aortic diameter, length, volume, and curvature were assessed. Pulse wave velocity, distensibility, and longitudinal strain (all measurements of aortic stiffness) were determined regionally. Moreover, advanced haemodynamic descriptors were quantified: systolic flow reversal ratio (SFRR), quantifying backward flow during systole, and in plane rotational flow (IRF), measuring in plane strength of helical flow. RESULTS: Twenty-six BTAI patients treated by TEVAR were included and matched with 26 HVs. They did not differ in terms of age, sex, and body surface area. Patients with TEVAR had a larger and longer ascending aorta (AAo) and marked abnormalities in local curvature. Aortic stiffness was greater in the aortic segments proximal and distal to TEVAR compared with controls. Moreover, TEVAR patients presented strongly altered flow dynamics compared with controls: a reduced IRF from the distal AAo to the proximal descending aorta and an increased SFRR in the whole thoracic aorta. These differences persisted adjusting for cardiovascular risk factors and were independent of time elapsed since TEVAR implantation. CONCLUSION: At long term follow up, previously healthy patients who underwent TEVAR implantation following BTAI had increased diameter, length and volume of the ascending aorta, and increased aortic stiffness and abnormal flow patterns in the whole thoracic aorta compared with matched controls. Further studies should address whether these alterations have clinical implications.


Asunto(s)
Aorta Torácica/lesiones , Aorta Torácica/cirugía , Heridas no Penetrantes/diagnóstico por imagen , Heridas no Penetrantes/cirugía , Adulto , Aorta Torácica/diagnóstico por imagen , Implantación de Prótesis Vascular , Estudios Transversales , Procedimientos Endovasculares , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Análisis de la Onda del Pulso , Heridas no Penetrantes/fisiopatología
12.
Neurocase ; 27(3): 319-322, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34338587

RESUMEN

We describe the first report on the genotype-phenotype patterns and [18F] fluoro-deoxygluycose (18F-FDG) Positron Emission Tomography (PET) findings in two disease-discordant monozygotic twins with Cri du Chat syndrome (CdcS) presenting deletion of 5p, 46, XY, del(5)(p14)/46, XY. One twin showed a severe phenotype; significant 18F-FDG PET hypometabolism (p=0.001) was revealed in the left and right hemispheres, thalamus, cerebellum, and midbrain, whereas hypermetabolism was detected in the left premotor cortex. The other twin presented a mild phenotype; significant hypometabolism was detected only in the right side (parahippoccampal gyrus and cerebellum). Further studies should investigate the causes of phenotypic discordance in twins with CdcS.


Asunto(s)
Síndrome del Maullido del Gato , Fluorodesoxiglucosa F18 , Cerebelo , Humanos , Tomografía de Emisión de Positrones , Gemelos Monocigóticos
13.
Eur Heart J ; 40(25): 2047-2055, 2019 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-30977783

RESUMEN

AIMS: Life expectancy in Marfan syndrome patients has improved thanks to the early detection of aortic dilation and prophylactic aortic root surgery. Current international clinical guidelines support the use of aortic root diameter as a predictor of complications. However, other imaging markers are needed to improve risk stratification. This study aim to ascertain whether proximal aorta longitudinal and circumferential strain and distensibility assessed by cardiac magnetic resonance (CMR) predict the aortic root dilation rate and aortic events in Marfan syndrome. METHODS AND RESULTS: One hundred and seventeen Marfan patients with no previous aortic dissection, cardiac/aortic surgery, or moderate/severe aortic regurgitation were prospectively included in a multicentre protocol of clinical and imaging follow-up. At baseline, CMR was performed and proximal aorta longitudinal strain and ascending aorta circumferential strain and distensibility were obtained. During follow-up (85.7 [75.0-93.2] months), the annual growth rate of aortic root diameter was 0.62 ± 0.65 mm/year. Fifteen patients underwent elective surgical aortic root replacement and four presented aortic dissection. Once corrected for baseline clinical and demographic characteristics and aortic root diameter, proximal aorta longitudinal strain, but not circumferential strain and distensibility, was an independent predictor of the aortic root diameter growth rate (P = 0.001, P = 0.823, and P = 0.997, respectively), z-score growth rate (P = 0.013, P = 0.672, and P = 0.680, respectively), and aortic events (P = 0.023, P = 0.096, and P = 0.237, respectively). CONCLUSION: Proximal aorta longitudinal strain is independently related to the aortic root dilation rate and aortic events in addition to aortic root diameter, clinical risk factors, and demographic characteristics in Marfan syndrome patients.


Asunto(s)
Aorta/patología , Enfermedades de la Aorta/diagnóstico , Dilatación Patológica/diagnóstico , Síndrome de Marfan/complicaciones , Adulto , Disección Aórtica/epidemiología , Aorta/diagnóstico por imagen , Enfermedades de la Aorta/cirugía , Presión Sanguínea/fisiología , Monitoreo Ambulatorio de la Presión Arterial/métodos , Diagnóstico Precoz , Femenino , Humanos , Espectroscopía de Resonancia Magnética/métodos , Masculino , Síndrome de Marfan/mortalidad , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , España/epidemiología
15.
Am J Med Genet A ; 179(8): 1525-1530, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31187941

RESUMEN

Skin picking (SP) disorder is characterized by recurrent SP resulting in skin lesions. Several studies estimated its prevalence as approximately 2-4 % of the general population. It is also present in a high percentage of patients with intellectual and developmental disabilities, such as Cri du chat (CdC) syndrome, a rare genetic disorder caused by variable size deletions of the short arm of chromosome 5. The aim of this study was to evaluate, in 97 patients with CdC syndrome, the following data: frequency of SP, patient's age at onset, type, and topographic-anatomic distribution of the lesions presented. The results show that 85% of patients confirm a SP disorder, usually concentrated on the hands, fingers, and the face, with onset between 6 and 10 years of age, regardless of patient's sex. Evidence for early appearance of SP behavior, high prevalence in stressful circumstances, and efficacy of distracting actions immediately suggest the possibility that proper parental information about SP behavior and parental education concerning the methods to deal with this problem may result in its efficient reduction already in childhood.


Asunto(s)
Deleción Cromosómica , Cromosomas Humanos Par 5 , Síndrome del Maullido del Gato/diagnóstico , Trastorno Obsesivo Compulsivo/diagnóstico , Estrés Psicológico/diagnóstico , Adolescente , Adulto , Distribución por Edad , Edad de Inicio , Niño , Preescolar , Síndrome del Maullido del Gato/epidemiología , Síndrome del Maullido del Gato/genética , Síndrome del Maullido del Gato/fisiopatología , Femenino , Humanos , Lactante , Italia/epidemiología , Masculino , Persona de Mediana Edad , Trastorno Obsesivo Compulsivo/epidemiología , Trastorno Obsesivo Compulsivo/genética , Trastorno Obsesivo Compulsivo/fisiopatología , Piel/lesiones , España/epidemiología , Estrés Psicológico/epidemiología , Estrés Psicológico/genética , Estrés Psicológico/fisiopatología , Encuestas y Cuestionarios
16.
Medicina (Kaunas) ; 55(7)2019 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-31284637

RESUMEN

Congenital sensorineural hearing loss may occur in association with inborn pigmentary defects of the iris, hair, and skin. These conditions, named auditory-pigmentary disorders (APDs), represent extremely heterogeneous hereditary diseases, including Waardenburg syndromes, oculocutaneous albinism, Tietz syndrome, and piebaldism. APDs are part of the neurocristopathies, a group of congenital multisystem disorders caused by an altered development of the neural crest cells, multipotent progenitors of a wide variety of different lineages, including those differentiating into peripheral nervous system glial cells and melanocytes. We report on clinical and genetic findings of two monozygotic twins from a large Albanian family who showed a complex phenotype featured by sensorineural congenital deafness, severe neuropsychiatric impairment, and inborn pigmentary defects of hair and skin. The genetic analyzes identified, in both probands, an unreported co-occurrence of a new heterozygous germline pathogenic variant (c.2484 + 5G > T splicing mutation) in the KIT gene, consistent with the diagnosis of piebaldism, and a heterozygous deletion at chromosome 15q13.3, responsible for the neuropsychiatric impairment. This case represents the first worldwide report of dual locus inherited syndrome in piebald patients affected by a complex auditory-pigmentary multisystem phenotype. Here we also synthesize the clinical and genetic findings of all known neurocristopathies characterized by a hypopigmentary congenital disorder.


Asunto(s)
Pérdida Auditiva Sensorineural/genética , Piebaldismo/genética , Femenino , Pérdida Auditiva Sensorineural/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Piebaldismo/complicaciones , Piebaldismo/fisiopatología , Reacción en Cadena de la Polimerasa/métodos , Gemelos/genética , Adulto Joven
17.
Magn Reson Med ; 79(5): 2816-2823, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-28980342

RESUMEN

PURPOSE: To decompose the 3D wall shear stress (WSS) vector field into its axial (WSSA ) and circumferential (WSSC ) components using a Laplacian finite element approach. METHODS: We validated our method with in silico experiments involving different geometries and a modified Poiseuille flow. We computed 3D maps of the WSS, WSSA , and WSSC using 4D flow MRI data obtained from 10 volunteers and 10 patients with bicuspid aortic valve (BAV). We compared our method with the centerline method. The mean value, standard deviation, root mean-squared error, and Wilcoxon signed rank test are reported. RESULTS: We obtained an error <0.05% processing analytical geometries. We found good agreement between our method and the modified Poiseuille flow for the WSS, WSSA , and WSSC . We found statistically significance differences between our method and a 3D centerline method. In BAV patients, we found a 220% significant increase in the WSSC in the ascending aorta with respect to volunteers. CONCLUSION: We developed a novel methodology to decompose the WSS vector in WSSA and WSSC in 3D domains, using 4D flow MRI data. Our method provides a more robust quantification of WSSA and WSSC in comparison with other reported methods. Magn Reson Med 79:2816-2823, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Anciano , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiología , Femenino , Análisis de Elementos Finitos , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Estrés Mecánico
18.
J Cardiovasc Magn Reson ; 20(1): 28, 2018 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-29695249

RESUMEN

BACKGROUND: In patients with bicuspid valve (BAV), ascending aorta (AAo) dilatation may be caused by altered flow patterns and wall shear stress (WSS). These differences may explain different aortic dilatation morphotypes. Using 4D-flow cardiovascular magnetic resonance (CMR), we aimed to analyze differences in flow patterns and regional axial and circumferential WSS maps between BAV phenotypes and their correlation with ascending aorta dilatation morphotype. METHODS: One hundred and one BAV patients (aortic diameter ≤ 45 mm, no severe valvular disease) and 20 healthy subjects were studied by 4D-flow CMR. Peak velocity, flow jet angle, flow displacement, in-plane rotational flow (IRF) and systolic flow reversal ratio (SFRR) were assessed at different levels of the AAo. Peak-systolic axial and circumferential regional WSS maps were also estimated. Unadjusted and multivariable adjusted linear regression analyses were used to identify independent correlates of aortic root or ascending dilatation. Age, sex, valve morphotype, body surface area, flow derived variables and WSS components were included in the multivariable models. RESULTS: The AAo was non-dilated in 24 BAV patients and dilated in 77 (root morphotype in 11 and ascending in 66). BAV phenotype was right-left (RL-) in 78 patients and right-non-coronary (RN-) in 23. Both BAV phenotypes presented different outflow jet direction and velocity profiles that matched the location of maximum systolic axial WSS. RL-BAV velocity profiles and maximum axial WSS were homogeneously distributed right-anteriorly, however, RN-BAV showed higher variable profiles with a main proximal-posterior distribution shifting anteriorly at mid-distal AAo. Compared to controls, BAV patients presented similar WSS magnitude at proximal, mid and distal AAo (p = 0.764, 0.516 and 0.053, respectively) but lower axial and higher circumferential WSS components (p < 0.001 for both, at all aortic levels). Among BAV patients, RN-BAV presented higher IRF at all levels (p = 0.024 proximal, 0.046 mid and 0.002 distal AAo) and higher circumferential WSS at mid and distal AAo (p = 0.038 and 0.046, respectively) than RL-BAV. However, axial WSS was higher in RL-BAV compared to RN-BAV at proximal and mid AAo (p = 0.046, 0.019, respectively). Displacement and axial WSS were independently associated with the root-morphotype, and circumferential WSS and SFRR with the ascending-morphotype. CONCLUSIONS: Different BAV-phenotypes present different flow patterns with an anterior distribution in RL-BAV, whereas, RN-BAV patients present a predominant posterior outflow jet at the sinotubular junction that shifts to anterior or right anterior in mid and distal AAo. Thus, RL-BAV patients present a higher axial WSS at the aortic root while RN-BAV present a higher circumferential WSS in mid and distal AAo. These results may explain different AAo dilatation morphotypes in the BAV population.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Imagen de Perfusión Miocárdica/métodos , Adulto , Anciano , Aorta Torácica/patología , Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Estudios de Casos y Controles , Dilatación Patológica , Femenino , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Fenotipo , Valor Predictivo de las Pruebas , Estudios Prospectivos , Flujo Sanguíneo Regional , Estrés Mecánico
19.
J Pediatr ; 183: 74-79.e1, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28153478

RESUMEN

OBJECTIVE: To evaluate the efficacy of combined pulse oximetry (POX) and perfusion index (PI) neonatal screening for severe congenital heart defects (sCHD) and assess different impacts of screening in tertiary and nontertiary hospitals. STUDY DESIGN: A multicenter, prospective study in 10 tertiary and 6 nontertiary maternity hospitals. A total of 42 169 asymptomatic newborns from among 50 244 neonates were screened; exclusion criteria were antenatal sCHD diagnosis, postnatal clinically suspected sCHD, and neonatal intensive care unit admission. Eligible infants underwent pre- and postductal POX and PI screening after routine discharge examination. Targeted sCHD were anatomically defined. Positivity was defined as postductal oxygen saturation (SpO2) ≤95%, prepostductal SpO2 gradient >3%, or PI <0.90. Confirmed positive cases underwent echocardiography for definitive diagnosis. Missed cases were identified by consulting clinical registries at 6 regional pediatric heart centers. Main outcomes were incidence of unexpected sCHD; proportion of undetected sCHD after discharge in tertiary and nontertiary hospitals; and specificity, sensitivity, positive predictive value, and negative predictive value of combined screening. RESULTS: One hundred forty-two sCHD were detected prenatally. Prevalence of unexpected sCHD was 1 in 1115 live births, similar in tertiary and nontertiary hospitals. Screening identified 3 sCHD (low SpO2, 2; coarctation for low PI, 1). Four cases were missed. In tertiary hospitals, 95% of unsuspected sCHDs were identified clinically, whereas only 28% in nontertiary units; in nontertiary units PI-POX screening increased the detection rate to 71%. CONCLUSIONS: PI-POX predischarge screening provided benefits in nontertiary units, where clinical recognition rate was low. PI can help identify coarctation cases missed by POX but requires further evaluation in populations with higher rates of missed cases.


Asunto(s)
Cardiopatías Congénitas/diagnóstico , Tamizaje Neonatal/métodos , Oximetría/métodos , Análisis de los Gases de la Sangre/métodos , Estudios de Cohortes , Cardiopatías Congénitas/epidemiología , Maternidades , Humanos , Incidencia , Recién Nacido , Unidades de Cuidado Intensivo Neonatal , Italia , Masculino , Consumo de Oxígeno/fisiología , Estudios Prospectivos , Medición de Riesgo , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Centros de Atención Terciaria
20.
ScientificWorldJournal ; 2017: 1940756, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29082306

RESUMEN

Early skin-to-skin contact (SSC) after birth is a physiological practice that is internationally recommended and has well-documented importance for the baby and for the mother. This study aims to examine SSC with a cohort of mothers or fathers in the operating room after a Cesarean section (C-section) and its relationship with duration of breastfeeding. From January 1, 2012, to December 31, 2012, at the Castelli Hospital in Verbania, Italy, a Baby Friendly designated hospital, 252 consecutive women who had a C-section were enrolled in the study and followed for 6 months. The sample was later divided into three groups depending on the real outcomes in the operating room: SSC with the mother (57.5%), SSC with the father (17.5%), and no SSC (25%). Our study showed a statistical association between skin-to-skin contact with the mother and the exclusive breastfeeding rates on discharge. This effect is maintained and statistically significant at three and six months, as compared to the groups that had paternal SSC or no SSC. After a C-section, skin-to-skin contact with the mother can be an important practice for support, promotion, and duration of breastfeeding.


Asunto(s)
Lactancia Materna , Cesárea , Relaciones Padres-Hijo , Tacto , Estudios de Cohortes , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Padres , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA