Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Opt Lett ; 49(2): 190-193, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38194525

RESUMEN

Compared to the most commonly used on-chip direct absorption spectroscopy (DAS) gas detection technique, the second harmonic (2f) based on-chip wavelength modulation spectroscopy (WMS) proposed by our group has the faculty to suppress noise and improve performance, but the accuracy of 2f WMS is easily affected by optical power variation. A mid-infrared auto-correction on-chip gas sensor based on 2f/1f WMS was proposed for decreasing the influence of the variation of optical power. The limit of detection of methane (CH4) obtained by a chalcogenide waveguide with a length of 10 mm is 0.031%. Compared with the 2f WMS, the maximum relative concentration error of the auto-correction on-chip gas sensor was decreased by ∼5.6 times. The measurement error is ≤2% in a temperature variation range of 30°C. This auto-correction sensor without a complicated manual calibration is helpful to the high accuracy measurement for on-chip integrated gas sensing.

2.
Nano Lett ; 23(23): 11082-11090, 2023 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-37991828

RESUMEN

Quasi-2D perovskites, multiquantum well materials with the energy cascade structure, exhibit impressive optoelectronic properties and a wide range of applications in various optoelectronic devices. However, the insufficient exciton energy transfer caused by the excess of small-n phases that induce nonradiative recombination and the spatially random phase distribution that impedes charge transport severely inhibit the device performance of light-emitting diodes (LEDs). Here, a faster energy transfer process and efficient carrier recombination are achieved by introducing the multifunctional additive 2-(methylsulfonyl)-4-(trifluoromethyl)benzoic acid (MTA) to manipulate the crystallization process of perovskites. The introduction of MTA not only constrains the PEA and restrains the formation of small-n phases to improve the energy transfer process but also optimizes the crystal orientation to promote charge transport. As a result, highly efficient pure green quasi-2D perovskite LEDs with a peak EQE of 25.9%, a peak current efficiency of 108.1 cd A-1, and a maximum luminance of 288798 cd m-2 are achieved.

3.
Opt Express ; 29(15): 23213-23224, 2021 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-34614589

RESUMEN

A trace gas sensing technique of light-induced off-axis cavity-enhanced thermoelastic spectroscopy (OA-CETES) in the near-infrared was demonstrated by combing a high-finesse off-axis integrated cavity and a high Q-factor resonant quartz tuning fork (QTF). Sensor parameters of the cavity and QTF were optimized numerically and experimentally. As a proof-of-principle, we employed the OA-CETES for water vapor (H2O) detection using a QTF (Q-factor ∼12000 in atmospheric pressure) and a 10cm-long Fabry-Perot cavity (finesse ∼ 482). By probing a H2O line at 7306.75 cm-1, the developed OA-CETES sensor achieved a minimum detection limit (MDL) of 8.7 parts per million (ppm) for a 300 ms integration time and a normalized noise equivalent absorption (NNEA) coefficient of 4.12 × 10-9cm-1 WHz-1/2. Continuous monitoring of indoor and outdoor atmospheric H2O concentration levels was performed for verifying the sensing applicability. The realization of the proposed OA-CETES technique with compact QTF and long effective path cavity allows a class of optical sensors with low cost, high sensitivity and potential for long-distance and multi-point sensing.

4.
ACS Sens ; 9(2): 820-829, 2024 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-38288631

RESUMEN

Cavity-enhanced direct frequency comb spectroscopy (CE-DFCS) is widely used as a highly sensitive gas sensing technology in various gas detection fields. For the on-axis coupling incidence scheme, the detection accuracy and stability are seriously affected by the cavity-mode noise, and therefore, stable operation inevitably requires external electronic mode-locking and sweeping devices, substantially increasing system complexity. To address this issue, we propose off-axis cavity-enhanced optical frequency comb spectroscopy from both theoretical and experimental aspects, which is applied to the detection of single- and dual-gas of carbon monoxide (CO) and carbon dioxide (CO2) in the near-infrared. An erbium-doped fiber frequency comb with a repetition frequency of ∼41.709 MHz is coupled into a resonant cavity with a length of ∼360 mm in an off-axis manner, exciting numerous high-order modes to effectively suppress cavity-mode noise. The performance of multiple machine learning models is compared for the inversion of a single/dual gas concentration. A few absorbance spectra are collected to build a sample data set, which is then utilized for model training and learning. The results demonstrate that the Particle Swarm Optimization Support Vector Machine (PSO-SVM) model achieves the highest predictive accuracy for gas concentration and is ultimately applied to the detection system. Based on Allan deviation, the detection limit for CO in single-gas detection can reach 8.247 parts per million by volume (ppmv) by averaging 87 spectra. Meanwhile, for simultaneous CO2/CO measurement with highly overlapping absorbance spectra, the LoD can be reduced to 13.196 and 4.658 ppmv, respectively. The proposed optical gas sensing technique indicates the potential for the development of a field-deployable and intelligent sensor system capable of simultaneous detection of multiple gases.


Asunto(s)
Dióxido de Carbono , Gases , Monóxido de Carbono , Aprendizaje Automático , Análisis Espectral
5.
ACS Nano ; 17(18): 17761-17770, 2023 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-37379223

RESUMEN

On-chip waveguide sensors are potential candidates for deep-space exploration because of their high integration and low power consumption. Since the fundamental absorption of most gas molecules exists in the mid-infrared (e.g., 3-12 µm), it is of great significance to fabricate wideband mid-infrared sensors with high external confinement factor (ECF). To overcome the limited transparency window and strong waveguide dispersion, a chalcogenide suspended nanorib waveguide sensor was proposed for ultra-wideband mid-infrared gas sensing, and three waveguide sensors (WG1-WG3) with optimized dimensions exhibit a wide waveband of 3.2-5.6 µm, 5.4-8.2 µm, and 8.1-11.5 µm with exceptionally high ECFs of 107-116%, 107-116%, and 116-128%, respectively. The waveguide sensors were fabricated by a two-step lift-off method without dry etching to reduce the process complexity. Experimental ECFs of 112%, 110%, and 110% were obtained at 3.291 µm, 4.319 µm, and 7.625 µm, respectively, through methane (CH4) and carbon dioxide (CO2) measurements. A limit of detection of 5.9 ppm was achieved for an averaging time of 64.2 s through the Allan deviation analysis of CH4 at 3.291 µm, leading to a comparable noise equivalent absorption sensitivity of 2.3 × 10-5 cm-1 Hz-1/2 as compared to the hollow-core fiber and on-chip gas sensors.

6.
Spectrochim Acta A Mol Biomol Spectrosc ; 256: 119745, 2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-33819761

RESUMEN

We demonstrated a novel multi-input multi-output (MIMO) laser-to-cavity coupling scheme in off-axis integrated cavity output spectroscopy (OA-ICOS) for cavity mode noise suppression. Theoretical investigation was performed to explore the relation between the number of splitting beams and the MIMO parameters. Mode distribution and propagation inside the cavity was simulated. The noise suppression factor of the MIMO scheme and the noise level and dominated noise in the cavity were studied based on cavity mode simulation. Methane measurements were carried out using a dual-input dual-output (DIDO, N = 2) sensor system to validate the presented scheme, and good agreement was found between simulation and experiment.

7.
Artículo en Inglés | MEDLINE | ID: mdl-34795779

RESUMEN

OBJECTIVE: To analyze the efficacy of androgen deprivation therapy (ADT) combined with radiation therapy (also known as radiotherapy) for prostate cancer. METHODS: The clinical data of 94 prostate cancer patients treated in the Oncology Department of Xiangzhou People's Hospital from January 2017 to January 2018 were retrospectively analyzed, and the patients were divided into the combined group and the reference group according to their admission order, with 47 cases each. The patients in the reference group only received the radiotherapy, and on this basis, those in the combined group accepted ADT, so as to evaluate the efficacy of different treatment methods by comparing the patients' serum total prostate-specific antigen (T-PSA), vascular endothelial growth factor (VEGF), and other indicators and analyze the relevant factors affecting patients' prognosis by Cox single-factor and multi-factor regression models. RESULTS: Compared with the reference group after treatment, the patients in the combined group obtained significantly lower T-PSA and VEGF levels (P < 0.001), significantly higher objective remission rate and disease control rate (P < 0.05), and remarkably longer modified progression-free survival (mPFS) and overall survival (OS) (P < 0.001), and after the multi-factor research, it was found that the Gleason score of 8-10, positive lymphatic metastasis, and single radiotherapy were the factors affecting the clinical prognosis of prostate cancer. CONCLUSION: Combining ADT with radiotherapy ensures a better survival benefit for prostate cancer patients and has a fairly well efficacy. Further study will be conducive to establishing a better solution for such patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA