RESUMEN
AIMS: Peripheral arteries are constantly exposed to deformation (elongation, twisting, shortening, compression) making bioresorbable scaffolds (BRS) a potentially attractive therapeutic alternative to metallic stents. We conducted a long-term pilot preclinical study of a novel sirolimus-eluting BRS in peripheral arteries. METHODS AND RESULTS: Fourteen BRS were deployed in iliofemoral arteries of seven healthy Yucatan miniswine and examined with imaging, pharmacokinetic, histopathologic, and polymer degradation techniques at 0, 30, 90, 180 days, 1, 2, and 3.3 years. Angiographic late luminal loss remained unchanged at 30 and 180 days but significantly decreased from 1 to 3.3 years. optical coherence tomography (OCT) showed late increase in lumen area (1 year: 14.70 ± 3.58 mm2 , 2 years 22.04 ± 3.81 mm2 , and 3.3 years 23.45 ± 7.07 mm2 ; p < .05) primarily due to scaffold area enlargement between 1 and 3.3 years, while there was no difference in the percent area stenosis at all time points. Histologic evidence of scaffold degradation was observed starting at 2 years, with minimal inflammatory reaction. At 3.3 years, BRS struts were rarely discernible by OCT, confirmed by a nearly complete polymer degradation by molecular weight analysis. CONCLUSIONS: In this pilot study, novel sirolimus-eluting BRS showed promising acute and chronic performance in the iliofemoral arteries of Yucatan miniswine.
Asunto(s)
Implantes Absorbibles , Angioplastia de Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Arteria Femoral/efectos de los fármacos , Arteria Ilíaca/efectos de los fármacos , Sirolimus/administración & dosificación , Angioplastia de Balón/efectos adversos , Animales , Fármacos Cardiovasculares/farmacocinética , Diseño de Equipo , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/patología , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/patología , Ensayo de Materiales , Modelos Animales , Proyectos Piloto , Sirolimus/farmacocinética , Porcinos , Porcinos Enanos , Factores de TiempoRESUMEN
OBJECTIVE: To compare the 1-year outcomes of complete percutaneous approach versus surgical vascular approach for transfemoral transcatheter aortic valve implantation (TAVI), among "real-world" patients from the multi-center Brazilian TAVI registry. BACKGROUND: Vascular access still remains a major challenge for TAVI via transfemoral approach. Vascular access through complete percutaneous approaches or through open surgical vascular techniques seems to be acutely similar. However, the long-term outcomes of both techniques remain poorly described. METHODS: The study population comprised all patients treated via transfemoral route in the Brazilian TAVI registry, a "real-world", nation-based, multi-center study. Patients were divided according to the initial vascular access approach (percutaneous vs. surgical) and clinically followed-up for 1 year. The primary endpoint was the incidence of combined adverse events all-cause mortality, life-threatening bleeding, and/or major vascular complication at 1 year. RESULTS: A total of 402 patients from 18 centers comprised the study population (percutaneous approach in 182 patients; surgical cutdown approach 220 patients). The incidence of combined adverse events was not different in the percutaneous and the surgical groups at 30 days (17.6% vs. 16.3%; P = 0.8) and at 1 year (primary endpoint) (30.9% vs. 28.8%; P = 0.8). Also, the study groups overall were comparable regarding the incidence of each individual safety adverse events at 30 days and at 1 year. CONCLUSION: Total percutaneous techniques or surgical cutdown and closure may provide similar safety and effectiveness during the first year of follow-up in patients undergoing transfemoral TAVI.
Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Arteria Femoral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Brasil , Comorbilidad , Femenino , Humanos , Masculino , Sistema de Registros , Factores de Riesgo , Resultado del TratamientoRESUMEN
Previous reports prove the safety and efficacy of cardiac pacing employing a guidewire in the left ventricle as unipolar pacing electrode. We describe the use of left ventricular guidewire pacing as an alternative to conventional transvenous temporary right ventricular pacing in the context of transcatheter aortic valve implantation.
Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco , Estimulación Cardíaca Artificial/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Marcapaso Artificial , Función Ventricular Izquierda , Anciano , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Diseño de Equipo , Humanos , Masculino , Índice de Severidad de la Enfermedad , Resultado del TratamientoRESUMEN
Percutaneous left atrial appendage closure (LAAC) has proven to be an effective alternative to oral anticoagulation (OAC) for stroke prevention in patients with non-valvular atrial fibrillation (NVAF). International guidelines traditionally recommend LAAC for NVAF patients at high thromboembolic risk and contraindication to or at high risk for OAC. However, there are many other clinical situations in which this procedure may also be beneficial. This paper discusses the potential role of LAAC in specific haemorrhagic diseases (cerebral amyloid angiopathy, age-related macular degeneration, hereditary haemorrhagic telangiectasia, and Moyamoya disease), after left atrial appendage (LAA) electrical isolation, in cases of persistent thrombus inside the LAA, in end-stage renal disease and in special groups of patients for whom low compliance and persistence to OAC may be anticipated.
RESUMEN
Although the incidence and severity of rheumatic mitral stenosis have declined in developed countries, the disease is still highly prevalent in many of the poorer and most densely populated areas of the globe, remaining a major public health issue and reflecting the socioeconomic status of the region. In the last 30 years, mitral stenosis therapy has undergone a reorientation with the introduction of percutaneous mitral valvuloplasty. This manuscript is an updated review of percutaneous dilation of mitral stenosis in its different aspects, encompassing traditional techniques, technical innovations, the most significant case loads worldwide, an analysis of the procedure as well as immediate and late outcomes.
Asunto(s)
Cateterismo Cardíaco , Cateterismo/métodos , Estenosis de la Válvula Mitral/terapia , Válvula Mitral/patología , HumanosRESUMEN
AIMS: Percutaneous left atrial appendage (LAA) occlusion is an alternative to oral anticoagulation for the prevention of stroke in patients with non-valvular atrial fibrillation (NVAF). Due to the great anatomic variability of the LAA, complete closure may not always be obtained with a single device. We report cases in which adequate closure of the LAA was achieved with implantation of two devices. METHODS AND RESULTS: Five out of 223 consecutive patients who underwent LAA occlusion without guidance with transoesophageal echocardiography (TOE) had a second device implanted to treat significant residual leaks or uncovered parts of the LAA after first device implantation. All procedures were successful, with no complications. Two patients received two AMPLATZER Cardiac Plugs (ACP); one patient received one ACP and one AMPLATZER Vascular Plug; one patient received one AMPLATZER Septal Occluder (ASO) and one ACP prototype; and one patient received two ASOs. TOE performed at least four months after the procedure showed complete closure of the LAA in all patients, without thrombus formation on the devices. After 14 patient-years there were no strokes, peripheral thromboemboli, or device embolisations. CONCLUSIONS: When necessary, the implantation of two devices to achieve complete LAA occlusion in patients with NVAF is feasible and leads to favourable results during follow-up. Potentially, this technical innovation may widen LAA occlusion indications by permitting occlusion of LAAs with large ostia or complex anatomy.
Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Dispositivo Oclusor Septal , Anciano , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Radiografía , Resultado del TratamientoRESUMEN
The patient is a male with risk factors for coronary artery disease, who was referred for cardiac catheterization after acute myocardial infarction in the inferior wall. The patient underwent transluminal coronary angioplasty in the right coronary artery with successful stent implantation.
Asunto(s)
Enfermedad de la Arteria Coronaria/etiología , Anomalías de los Vasos Coronarios/complicaciones , Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria/terapia , Anomalías de los Vasos Coronarios/terapia , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/terapia , Factores de Riesgo , StentsRESUMEN
BACKGROUND: Unfavorable immediate or delayed results after transcatheter aortic valve implantation (TAVI) may be a consequence of bioprosthesis malfunctioning, malpositioning, embolization, or degeneration. Deployment of a second valve within the first one implanted (TAVI-in-TAV) may be a potentially helpful therapeutic strategy. METHODS: Six out of 412 patients undergoing TAVI had TAVI-in-TAV implantation for the treatment of a too high (n = 4) or too low position (n = 2) of the first implanted valve. RESULTS: All TAVI-in-TAV procedures were successfully performed. The calculated valve area after second valve implantation was 1.6 ± 0.3 cm(2) with a mean gradient of 7.3 ± 2.2 mm Hg. Residual aortic regurgitation (AR) was mild in 5 patients and moderate in 1. At mid-term follow-up (30-724 days) neither the mean valve area (1.47 ± 0.31 cm(2)), the mean gradient (7.5 ± 3.6 mm Hg; 3.0-13.0 mm Hg) nor the degree of AR had changed significantly. CONCLUSION: TAVI-in-TAV for correction of malpositioned or embolized valves is technically feasible and leads to favorable functional results during mid-term follow-up.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Falla de Prótesis , Resultado del TratamientoRESUMEN
OBJECTIVES: We sought to test the efficacy and safety of the implantation of a stent covered with biosynthetic cellulose compared to a conventional bare-metal stent (BMS) in a rabbit iliac artery model. BACKGROUND: Biosynthetic cellulose is a biocompatible film used in several fields of medicine. Stents covered with biosynthetic cellulose are devices with the potential of achieving total lesion coverage, acting as a physical barrier to the migration of smooth muscle cells from the artery wall to the arterial lumen, and capturing circulating endothelial progenitor cells that may form a functional endothelial layer. METHODS AND RESULTS: Seven BMS and 7 stents covered with biosynthetic cellulose were implanted in the iliac arteries of 7 rabbits. Angiographic restudy and morphometric analysis of the specimens were performed after 4 weeks. No intrastent angiographic restenosis was observed, either with BMS or with stents covered with biosynthetic cellulose. There was also no acute or late vessel occlusion caused by stent thrombosis in either group. In the BMS and biosynthetic cellulose stented groups, respectively, mean neointimal thicknesses were 0.18 +/- 0.02 mm and 0.35 +/- 0.02 mm*; lumen area, 4.6 +/- 0.43 mm2 and 4.04 +/- 0.42 mm2; neointimal area, 0.58 +/- 0.09 mm2 and 2.13 +/- 0.11 mm(2)*; % lumen, 79.09 +/- 1.6% and 58.44 +/- 3.26%*; % stenosis, 10.97 +/- 1.23% and 35.55 +/- 3.39%* (*p < 0.05 vs. bare-metal). CONCLUSIONS: Implantation of stents covered with biosynthetic cellulose was safe, with no acute or late vessel occlusion caused by stent thrombosis, although it resulted in a more pronounced absolute neointimal thickness when compared to BMS.
Asunto(s)
Angioplastia de Balón/instrumentación , Celulosa/efectos adversos , Materiales Biocompatibles Revestidos/efectos adversos , Arteria Ilíaca/fisiología , Stents/efectos adversos , Angiografía , Angioplastia de Balón/métodos , Animales , Constricción Patológica/epidemiología , Constricción Patológica/prevención & control , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/patología , Incidencia , Modelos Animales , Conejos , Flujo Sanguíneo Regional/fisiología , Factores de Riesgo , Trombosis/epidemiología , Trombosis/prevención & control , Túnica Íntima/diagnóstico por imagen , Túnica Íntima/patologíaRESUMEN
The metallic commissurotome (MC) technique is a cheaper alternative to the Inoue balloon (IB) technique for percutaneous mitral valvuloplasty (PMV). There are no randomized trials comparing these techniques with longer follow-up of the patients. The objective of this study was to compare the immediate results and short- and medium-term follow-up of PMV using either the IB or the MC technique. Fifty patients with rheumatic mitral stenosis were randomly assigned to PMV using the IB (n = 27) or the MC (n = 23) technique. There were no significant differences between the groups regarding baseline clinical, echocardiographic, and hemodynamic data. Clinical and echocardiographic follow-up were done 6 months and 3 years after the procedure. The success rate was 100% in the IB group and 91.3% in the MC group (P = 0.15); two patients in the latter group developed mitral regurgitation grade 3/4, requiring elective surgery. The mean final mitral valve area was bigger in the MC group (2.17 +/- 0.13 vs. 2.00 +/- 0.36 cm2; P = 0.04), but after 6-month and 3-year follow-up, this difference was no longer significant (2.06 +/- 0.27 vs. 1.98 +/- 0.38 cm2, P = 0.22, and 1.86 +/- 0.32 vs. 1.87 +/- 0.34 cm2, P = 0.89, respectively). This finding suggests valve stretching as an important mechanism of valve dilation with the MC. Three patients in the MC group and two patients in the IB group (P = 0.65) developed mitral valve restenosis; one of them underwent repeat PMV and the other four, all asymptomatic, were clinically followed. PMV performed either with the IB or the MC technique is effective and provides excellent short- and medium-term outcomes regardless of the technique employed.
Asunto(s)
Cateterismo/instrumentación , Estenosis de la Válvula Mitral/terapia , Cardiopatía Reumática/terapia , Adolescente , Adulto , Ecocardiografía , Electrocardiografía , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/fisiopatología , Estudios Retrospectivos , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/fisiopatología , Resultado del TratamientoRESUMEN
A case of a 62-year-old patient with Ebstein's anomaly is presented. Despite the severe anatomical abnormalities, he was asymptomatic until 61 years of age. Anatomic aspects, clinical features and the diagnostic techniques used are analyzed.
Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Anomalía de Ebstein , Ecocardiografía , ElectrocardiografíaRESUMEN
Aneurysm of the left main coronary artery is a rare angiographic finding, with few cases described in the international literature. We report the case of a 42-year-old male with a previous history of acute myocardial infarction, whose coronariography indicated triple vessel coronary disease and an aneurysm of the left main coronary artery. A review of the etiology, clinical aspects, and surgical management of coronary arterial aneurysm is presented
Asunto(s)
Humanos , Masculino , Adulto , Aneurisma Coronario/etiología , Aneurisma Coronario/cirugía , Vasos Coronarios/patologíaRESUMEN
The patient is a male with risk factors for coronary artery disease, who was referred for cardiac catheterization after acute myocardial infarction in the inferior wall. The patient underwent transluminal coronary angioplasty in the right coronary artery with successful stent implantation