Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Neurosurg Rev ; 47(1): 123, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38503965

RESUMEN

Low-profile stents may provide significant advantages in Y-stent-assisted coiling due to their miniaturized design and capability to be delivered through a 0.0165-inch microcatheter. We aim to investigate the safety and efficacy of using these newer versions of stents in Y-stent-assisted coiling for the treatment of wide-necked bifurcation aneurysms. We conducted a systematic review of the PubMed, Embase, Cochrane Library, and Web of Science databases up to September 2023, following the PRISMA guidelines. Eligible studies included ≥ 5 patients with intracranial wide-necked bifurcation aneurysms treated with Y-stent-assisted coiling using low-profile stents, providing angiographic and clinical outcomes. Two authors independently handled the search and selection. Primary outcomes were immediate and follow-up aneurysm occlusion, procedure-related complications, aneurysm recanalization, and retreatment. Secondary outcomes included technical success, procedure-related morbidity, procedure-related mortality, procedure-related stroke, and in-stent stenosis at follow-up. We analyzed the data using random-effects meta-analysis. In total, 19 studies including 507 patients with 509 aneurysms were included. 95% of the treated aneurysms were managed using the crossing Y-configuration. Technical success rate was 99%. Immediate adequate aneurysm occlusion was 90%. Follow-up angiographies were available for 443 aneurysms. The mean angiographic follow-up duration was 15.6 ± 1.9 months. The rates for follow-up adequate aneurysm occlusion and complete occlusion were 98% and 89%, respectively. After a mean clinical follow-up of 15 ± 2.4 months, a good clinical outcome was observed in 98% of patients. Overall, procedure-related morbidity and mortality rates were 1.3%, and 0.4%, respectively. Low-profile stents in Y-stent-assisted coiling outperform previous stent versions in terms of safety, efficacy, and technical success rates.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Stents , Humanos , Aneurisma Intracraneal/terapia , Embolización Terapéutica/métodos , Embolización Terapéutica/instrumentación , Resultado del Tratamiento , Procedimientos Endovasculares/métodos
2.
Neurosurg Rev ; 47(1): 217, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38736006

RESUMEN

Dural Arteriovenous Fistulas (dAVFs) of the anterior cranial fossa (ACF) are uncommon but carry a high risk of hemorrhage and pose substantial treatment challenges. Recent advancements in endovascular treatment (EVT), including the introduction of novel liquid embolic agents, have markedly bolstered EVT's role in managing ACF-dAVFs, with notable series published in the last five years. We aimed to assess the feasibility, safety, and efficacy of EVT for ACF-dAVFs. We searched Medline, Scopus, Web of Science, and Cochrane Library databases following PRISMA guidelines. Eligible studies included those with ≥ 5 patients undergoing embolization of ACF-dAVFs, detailing both angiographic and clinical outcomes. We used single proportion analysis with 95% confidence intervals under a random-effects model, I2 to assess heterogeneity, and Baujat and sensitivity analysis to address high heterogeneity. Publication bias was assessed by funnel-plot analysis and Egger's test. Outcomes included complete occlusion following embolization, unsuccessful endovascular embolization attempts, incomplete occlusion following embolization, symptom resolution or clinical improvement following embolization, recurrence; procedure-related complications, morbidity, and mortality. Additionally, a subanalysis for studies exclusively utilizing Onyx™ embolic system was done. Eighteen studies comprising 231 ACF-dAVF were included. Unsuccessful endovascular embolization attempts rate was 2%. Complete occlusion rate was 85%, with 4% of complications. Incomplete occlusion rate was 10%. Successfully embolized patients experienced either symptom resolution or clinical improvement in 94% of cases. Morbidity and mortality rates were 1% and 0%, respectively. Onyx subanalyses showed an overall rate of 0% for unsuccessful attempts, 95% for complete occlusion, and 5% for incomplete occlusion. Symptom resolution or clinical improvement was 98% and recurrence rate was 0%. EVT for ACF-dAVF is highly feasible, effective, and safe, with a low rate of complications, morbidity, and mortality. The subanalyses focusing on Onyx embolizations revealed superior efficacy and safety outcomes compared to the findings of the primary analyses involving all included studies.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central , Fosa Craneal Anterior , Embolización Terapéutica , Procedimientos Endovasculares , Polivinilos , Humanos , Malformaciones Vasculares del Sistema Nervioso Central/terapia , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Polivinilos/uso terapéutico , Resultado del Tratamiento , Dimetilsulfóxido/uso terapéutico , Estudios de Factibilidad
3.
Neurosurg Rev ; 47(1): 722, 2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39358561

RESUMEN

Meta-analyses are highly valued in medical science, yet accurately reporting complications in neurosurgical studies remains challenging. Examples include inconsistencies in defining and classifying complications and variations in reporting methods. This lack of reproducibility and comparability, along with other issues related to biases, hinders the ability of meta-analyses to yield significant advancements. This systematic review investigated the challenges and limitations inherent in meta-analyses of complications in neurosurgery. Based on the identified challenges and our group's experience, we developed a practical checklist to mitigate and avoid common errors in meta-analyses of complications in neurosurgery.We searched PubMed, Embase, and Web of Science for studies addressing challenges in assessing complications in neurosurgery. The main findings were qualitatively synthesized to identify common challenges and limitations. The proposed checklist was developed using a modified Delphi technique. Eleven studies were included, uncovering heterogeneity and a lack of standardization regarding the classification of complications in neurosurgery across various authors and institutions. They suggested solutions such as implementing a more uniform classification system. Additionally, the NeuroComp Meta-Analysis Checklist was developed, comprising 23 items divided into 5 domains, with a practical approach and suggestions on how to deal with the challenges when meta-analyzing.We identified numerous challenges and concerns when assessing complications in the neurosurgical field. The NeuroComp Meta-Analysis Checklist incorporated methodologies and approaches we utilized in several previously published meta-analyses. While we acknowledge that the proposal cannot solve all the issues involved in comparing and meta-analyzing complications in neurosurgery, it has the potential to enhance the informativeness of future meta-analyses and help authors mitigate common errors. Ultimately, this tool has the potential to contribute to the advancement of accumulating real-world evidence in neurosurgical science.


Asunto(s)
Lista de Verificación , Procedimientos Neuroquirúrgicos , Complicaciones Posoperatorias , Humanos , Procedimientos Neuroquirúrgicos/métodos , Procedimientos Neuroquirúrgicos/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Metaanálisis como Asunto , Neurocirugia
5.
Neuroradiol J ; 37(5): 603-610, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38622821

RESUMEN

INTRODUCTION: Wide-necked bifurcation aneurysms pose significant challenges for endovascular treatment. A recent innovation, the stent plus balloon-assisted coiling technique, combines a stent and a balloon to address these aneurysms effectively. PURPOSE: To evaluate the safety and efficacy of the stent plus balloon-assisted coiling for the treatment of wide-necked bifurcation aneurysms. METHODS: We conducted a retrospective review of our endovascular database to identify patients who were treated with this technique and had a satisfactory angiographic follow-up of at least 24 months. Technical success, initial clinical and angiographic outcomes, procedural complications, and follow-up results were analyzed. Angiographic and clinical outcomes were assessed using Modified Raymond-Roy Classification and Modified Rankin Scale, respectively. RESULTS: Our study included 37 aneurysms in 36 patients (26 females) with a mean age of 56.6 years. Mean aneurysm and neck sizes were 7.3 ± 3.5 mm and 3.7 ± 1.0 mm, respectively. Technical success reached 97.2%, with an immediate occlusion rate of 65.7%. At a mean follow-up of 36.5 ± 9.7 months, final angiographic follow-up showed a 91.9% complete occlusion rate. Three aneurysms did not achieve complete occlusion; however, none required retreatment. Complications developed in 32.4% of the procedures. Mortality and morbidity rates were 5.4% and 2.7%, respectively. A good clinical outcome was observed in 91.9% of patients. CONCLUSION: Our results showed that stent plus balloon-assisted coiling technique allows good angiographic outcomes for wide-necked bifurcation aneurysms. However, overall complication rate is high. Subgroup analysis indicated promising safety and efficacy for MCA bifurcation aneurysms, suggesting this technique could be a valuable option for select aneurysms.


Asunto(s)
Angiografía Cerebral , Aneurisma Intracraneal , Stents , Humanos , Femenino , Aneurisma Intracraneal/terapia , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Anciano , Oclusión con Balón/métodos , Adulto , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/instrumentación , Embolización Terapéutica/métodos , Embolización Terapéutica/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA