Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Neoplasma ; 67(5): 1032-1041, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32453598

RESUMEN

Nasopharyngeal cancer (NPC) is a type of head and neck cancer with a high rate of metastasis. Circular RNAs (circRNAs) were reported to be related to the development of human cancers. This research aimed to investigate the functional mechanism of circRNA circ_0000615 in NPC. The gene expression was examined by quantitative real-time polymerase chain reaction (qRT-PCR) or western blot. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay was employed to assess cell proliferation ability. Transwell assay was used to measure cell migratory and invasive abilities. Furthermore, the interaction between miR-338-3p and circ_0000615 or fibroblast growth factor 2 (FGF2) was predicted by starBase v.2.0 and then confirmed by the dual-luciferase reporter assay. Besides, the mouse xenograft experiment was carried out to explore the effect of circ_0000615 on tumor growth in vivo. We detected increased levels of circ_0000615 and FGF2, along with a decreased level of miR-338-3p in NPC tissues and cells. Circ_0000615 knockdown suppressed the proliferation, migration, invasion, and EMT of NPC cells. Interestingly, circ_0000615 interacted with miR-338-3p, and miR-338-3p targeted FGF2. Circ_0000615 inhibited miR-338-3p expression to upregulate the FGF2 level. Furthermore, both miR-338-3p depletion and FGF2 overexpression weakened the effect of circ_0000615 knockdown on NPC cell progression. Besides, circ_0000615 knockdown repressed tumor growth in vivo. In conclusion, our findings demonstrated that circ_0000615 knockdown suppressed the growth of NPC cells via modulating miR-338-3p/FGF2 axis, providing a theoretical basis for the treatment of NPC.


Asunto(s)
Factor 2 de Crecimiento de Fibroblastos/genética , MicroARNs/genética , Neoplasias Nasofaríngeas , ARN Circular/genética , Animales , Línea Celular Tumoral , Movimiento Celular , Técnicas de Silenciamiento del Gen , Humanos , Ratones , Neoplasias Nasofaríngeas/genética , Neoplasias Nasofaríngeas/patología
2.
Zhonghua Yan Ke Za Zhi ; 56(4): 279-285, 2020 Apr 11.
Artículo en Zh | MEDLINE | ID: mdl-32306620

RESUMEN

Objective: To elevated the retinal toxicity of intravitreal ganciclovir in albino rabbit eyes. Methods: Experimental study. Twenty-four New Zealand albino rabbits (forty-eight eyes) were divided into four groups by random. Three groups were prepared for ganciclovir experiment, named A, B, C. Each group received intravitreal injection ganciclovir dose at 400 µg/0.05 ml, 2 mg/0.05 ml and 5 mg/0.05 ml respectively. The other group named D served as a control accepted intravitreal injection 0.9% normal saline 0.1 ml. Before and after 1, 2 and 4 weeks, flicker full field electroretina gram (ERG) was recorded. After 1, 2 and 4 weeks light and electron microscopic tests were recorded for further toxicity study. Results: There was significant difference in amplitude of maximal combined response a wave in one week(χ(2)=8.319, P=0.04), and pairwise comparison the 5 mg group (140.50 µV) was significantly lower than the control group (165.00 µV) (χ(2)=-2.830, P=0.028). Maximal combined response b wave in four weeks(χ(2)=-10.626, P=0.014), and pairwise comparison the 5 mg group (261.50 µV) was significantly lower than the control group (398.00 µV) (χ(2)=-2.973, P=0.018). 30 Hz flicker response in one, two and four weeks(χ(2)=17.589, 8.225, 8.997, P=0.001, 0.042, 0.02), and pairwise comparison the 5 mg group (71.3µV, 106.00µV, 63.60µV) was significantly lower than the control group (118.50µV, 129.00µV, 116.50µV) (χ(2)=-4.142, -2.826, -2.713, P=0.000, 0.028, 0.040). There was no histologic retinal toxicity evidence of group 400 µg and control group observed by light microscopy in any stage of the study. Histologic changes of group 2 mg four week later, group 5 mg two and four week later include inner nuclear layer loose arranged, nuclear of ganglia were widened and outer plexiform layer stained less in four week later. By electron microscopic observation, the ultrastructure of retina changed to different degrees and became worse in each experimental group with significant mitochondrial swelling and hydropic changes were seen in the inner segments of photoreceptors, loosely arranged and disordered in the outer segment of photoreceptors four weeks later. Conclusions: The retinal function and morphology were normal in group 400 µg. Group 2 mg and 5 mg had retinal toxicity, and 5 mg was more severe. Therefore, the clinical application of ganciclovir in the treatment of acute retinal necrosis (ARN) should select the minimum effective dose to avoid the occurrence of retinal toxicity. (Chin J Ophthalmol, 2020, 56:279-285).


Asunto(s)
Ganciclovir/toxicidad , Retina/efectos de los fármacos , Animales , Inyecciones Intravítreas , Conejos , Distribución Aleatoria , Retina/patología , Retina/ultraestructura , Pruebas de Toxicidad
3.
Opt Express ; 27(2): 470-482, 2019 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-30696132

RESUMEN

Molecular emission can be used for isotopic analysis in laser-induced breakdown spectroscopy (LIBS) due to its large isotopic shift. However, spectral weakness and interference have become the main flaws in molecular isotopic analysis, causing deterioration of quantitative accuracy and sensitivity. Here, to overcome these problems, laser-induced radical fluorescence (LIRF) was applied to enhance the molecular spectra and eliminate the spectral interference. The root mean square errors of cross validation (RMSECVs) of boron and carbon isotopes (11BO, 10BO, 12CN, and 13CN) improved to 2.632, 5.721, 5.990, and 1.543 at.%, as compared with 16.96, 35.79, 57.10, and 13.89 at.%, respectively, obtained in the case without LIRF. The limits of detection (LoDs) of 11BO, 10BO, 12CN, and 13CN were 0.9858, 0.8470, 1.606, and 1.193 at.%, respectively. This work demonstrates the feasibility of LIBS-LIRF to achieve isotopic determination with high accuracy and sensitivity.

4.
Opt Express ; 26(18): 22926-22933, 2018 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-30184949

RESUMEN

The calibration-free laser-induced breakdown spectroscopy (CF-LIBS) and its variations are low cost, short time consumption, and high adaptability. However, seeking a more flexible and simple quantitative analysis method remains a challenge. A one-point and multi-line calibration (OP-MLC) was presented as a simple quantitative analysis method of LIBS. The results showed that OP-MLC-LIBS method can achieve quantitative analysis using only one standard sample, and the average relative errors (AREs) are 9, 22, 21 and 36% for Mn, Cr, Ni and Ti elements in six tested low-alloy steel samples, respectively. The method requires neither a large number of standard samples nor complicated calculations, which provides a flexible and low-cost quantitative analysis approach for development and application of LIBS.

5.
Opt Express ; 26(3): 2634-2642, 2018 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-29401800

RESUMEN

Boron is an essential element for industry, but it is hard to accurately and rapidly determine high boron content with conventional laser-induced breakdown spectroscopy (LIBS), due to the matrix and self-absorption effect. Using molecular emission is an alternative method for boron content analysis, but its weak spectra are major challenges. Here, boron monoxide (BO) radicals were used to establish calibration assisted by LIBS and laser-induced radical fluorescence (LIBS-LIRF). Two types of BO radical excitations, vibrational ground state excitation (LIRFG) and vibrational excited state excitation (LIRFE), were compared. The results showed that LIRFG achieved better sensitivity with a limit of detection of 0.0993 wt.%, while the LIRFE was more accurate with a root mean square error of cross validation of 0.2514 wt.%. In conclusion, this work provided a potential approach for molecular emission analysis with LIBS-LIRF.

6.
Opt Express ; 24(23): 26521-26528, 2016 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-27857385

RESUMEN

The self-absorption at reduced air pressure for quantitative analysis of Mn and Cu elements in steel using laser-induced breakdown spectroscopy was investigated. The calibration curves of Mn and Cu elements at the air pressures of 100, 80, 50, 20, and 1 kPa were studied. The results show that, the nonlinearity of calibration curves which caused by self-absorption effects at atmosphere could be significantly improved by reducing the air pressure to 1 kPa, and the coefficients of determination (R2) of linear calibration curves of Mn and Cu lines are all higher than 0.99. The further study explored that the reason for the improvement was that the induced plasma became low density and the self-absorption coefficient was close to 1 when the air pressure reduced to 1 kPa.

7.
Opt Express ; 24(3): 2607-18, 2016 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-26906833

RESUMEN

The matrix effect of powder samples, especially for soil samples, is significant in laser-induced breakdown spectroscopy (LIBS), which affects the prediction accuracy of the element concentration. In order to reduce this effect of the soil samples in LIBS, the standard addition method (SAM) based on background removal by wavelet transform algorithm was investigated in this work. Five different kinds of certified reference soil samples (lead (Pb) concentrations were 110, 283, 552, 675, and 1141 ppm, respectively) were used to examine the accuracy of this method. The root mean square error of prediction (RMSEP) was more than 303 ppm by using the conventional calibration method. After adoption of SAM with background removal by wavelet transform algorithm, the RMSEP was reduced to 25.7 ppm. Therefore, the accuracy of the Pb element was improved significantly. The mechanism of background removal by wavelet transform algorithm based on SAM is discussed. Further study demonstrated that this method can also improve the predicted accuracy of the Cd element.


Asunto(s)
Rayos Láser , Suelo/química , Análisis Espectral/métodos , Algoritmos , Cadmio/análisis , Calibración , Análisis de Ondículas
8.
Opt Express ; 24(12): 13410-7, 2016 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-27410358

RESUMEN

In this study, chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy (CR-SENLIBS) was for the first time applied to improve the detection sensitivities of trace heavy metal elements in aqueous solutions. Utilizing chemical replacement effect, heavy metal ions in aqueous solution were enriched on the magnesium alloy surface as a solid replacement layer through reacting with the high chemical activity metallic magnesium (Mg) within 1 minute. Unitary and mixed solutions with Cu, Pb, Cd, and Cr elements were prepared to construct calibration curves, respectively. The CR-SENLIBS showed a much better detection sensitivity and accuracy for both unitary and mixed solutions. The coefficients of determination R2 of the calibration curves were above 0.96, and the LoDs were of the same order of magnitude, i.e., in the range of 0.016-0.386 µg/mL for the unitary solution, and in the range of 0.025-0.420 µg/mL for the mixed solution. These results show that CR-SENLIBS is a feasible method for improving the detection sensitivity of trace element in liquid sample, which definitely provides a way for wider application of LIBS in water quality monitoring.

9.
Opt Express ; 23(6): 7795-801, 2015 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-25837118

RESUMEN

Laser-induced breakdown spectroscopy (LIBS) with partial least squares regression (PLSR) has been applied to measuring the acidity of iron ore, which can be defined by the concentrations of oxides: CaO, MgO, Al2O3, and SiO2. With the conventional internal standard calibration, it is difficult to establish the calibration curves of CaO, MgO, Al2O3, and SiO2 in iron ore due to the serious matrix effects. PLSR is effective to address this problem due to its excellent performance in compensating the matrix effects. In this work, fifty samples were used to construct the PLSR calibration models for the above-mentioned oxides. These calibration models were validated by the 10-fold cross-validation method with the minimum root-mean-square errors (RMSE). Another ten samples were used as a test set. The acidities were calculated according to the estimated concentrations of CaO, MgO, Al2O3, and SiO2 using the PLSR models. The average relative error (ARE) and RMSE of the acidity achieved 3.65% and 0.0048, respectively, for the test samples.

10.
Genet Mol Res ; 14(2): 6786-95, 2015 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-26125886

RESUMEN

Two rice doubled haploid (DH) populations derived from the crosses of ZYQ8/JX17 and CJ06/TN1 were used to detect quantitative trait loci (QTLs) for flag leaf length (FLL), width (FLW), and angle (FLA) under long-day conditions in Hangzhou (subtropical zone) and short-day conditions in Hainan (tropical zone), China. The four parents differed significantly in all 3 traits. FLL was found to be positively correlated with FLW in the 2 populations. A total of 30 QTLs were identified for flag leaf traits, with a contribution to the phenotypic variation of each QTL from 4.49 to 26.30%. Among these, qFLL-4b, qFLW-12, and qFLA-2a showed larger additive effects on the phenotype and explained more variations compared to the other QTLs. qFLL-1a and qFLL-8 were detected in both environments, while qFLL-2, qFLL-3, qFLL-10, qFLL-12, qFLW11, qFLW2, and qFLA8 were novel QTLs, which may be beneficial to rice ideal-type breeding.


Asunto(s)
Genoma de Planta , Haploidia , Oryza/genética , Hojas de la Planta/genética , Sitios de Carácter Cuantitativo , Cruzamiento , China , Mapeo Cromosómico , Cruzamientos Genéticos , Genotipo , Oryza/anatomía & histología , Fenotipo , Fotoperiodo , Hojas de la Planta/anatomía & histología , Clima Tropical
11.
Opt Express ; 22(4): 3895-901, 2014 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-24663709

RESUMEN

A new approach to polymer identification by laser-induced breakdown spectroscopy (LIBS) with adjusting spectral weightings (ASW) was developed in this work aiming at improving the identification accuracy. This approach has been achieved through increasing the intensities of specific characteristic spectral lines which are important to polymer identification but difficult to be excited. Using the ASW method, the identification accuracies of all 11 polymers were increased to nearly 100%, while the accuracies of PE, PU, PP and PC were only 98%, 74%, 90% and 98%, respectively, without using the ASW method.

12.
Opt Express ; 22(9): 10233-8, 2014 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-24921726

RESUMEN

A modified algorithm of background removal based on wavelet transform was developed for spectrum correction in laser-induced breakdown spectroscopy (LIBS). The optimal type of wavelet function, decomposition level and scaling factor γ were determined by the root-mean-square error of calibration (RMSEC) of the univariate regression model of the analysis element, which is considered as the optimization criteria. After background removal by this modified algorithm with RMSEC, the root-mean-square error of cross-validation (RMSECV) and the average relative error (ARE) criteria, the accuracy of quantitative analysis on chromium (Cr), vanadium (V), cuprum (Cu), and manganese (Mn) in the low alloy steel was all improved significantly. The results demonstrated that the algorithm developed is an effective pretreatment method in LIBS to significantly improve the accuracy in the quantitative analysis.

13.
Opt Express ; 21(15): 18188-95, 2013 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-23938689

RESUMEN

To improve the accuracy of quantitative analysis in laser-induced breakdown spectroscopy, the plasma produced by a Nd:YAG laser from steel targets was confined by a cavity. A number of elements with low concentrations, such as vanadium (V), chromium (Cr), and manganese (Mn), in the steel samples were investigated. After the optimization of the cavity dimension and laser fluence, significant enhancement factors of 4.2, 3.1, and 2.87 in the emission intensity of V, Cr, and Mn lines, respectively, were achieved at a laser fluence of 42.9 J/cm(2) using a hemispherical cavity (diameter: 5 mm). More importantly, the correlation coefficient of the V I 440.85/Fe I 438.35 nm was increased from 0.946 (without the cavity) to 0.981 (with the cavity); and similar results for Cr I 425.43/Fe I 425.08 nm and Mn I 476.64/Fe I 492.05 nm were also obtained. Therefore, it was demonstrated that the accuracy of quantitative analysis with low concentration elements in steel samples was improved, because the plasma became uniform with spatial confinement. The results of this study provide a new pathway for improving the accuracy of quantitative analysis of LIBS.


Asunto(s)
Algoritmos , Rayos Láser , Ensayo de Materiales/métodos , Metales/química , Metales/efectos de la radiación , Análisis Espectral/métodos , Sensibilidad y Especificidad
14.
Opt Express ; 20(2): 1436-43, 2012 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-22274487

RESUMEN

In laser-induced breakdown spectroscopy (LIBS), a pair of aluminum-plate walls were used to spatially confine the plasmas produced in air by a first laser pulse (KrF excimer laser) from chromium (Cr) targets with a second laser pulse (Nd:YAG laser at 532 nm, 360 mJ/pulse) introduced parallel to the sample surface to re-excite the plasmas. Optical emission enhancement was achieved by combing the spatial confinement and dual-pulse LIBS (DP-LIBS), and then optimized by adjusting the distance between the two walls and the interpulse delay time between both laser pulses. A significant enhancement factor of 168.6 for the emission intensity of the Cr lines was obtained at an excimer laser fluence of 5.6 J/cm(2) using the combined spatial confinement and DP-LIBS, as compared with an enhancement factor of 106.1 was obtained with DP-LIBS only. The enhancement mechanisms based on shock wave theory and reheating in DP-LIBS are discussed.


Asunto(s)
Láseres de Excímeros , Láseres de Estado Sólido , Análisis Espectral/instrumentación , Análisis Espectral/métodos , Aluminio/química , Cromo/química , Espacios Confinados , Diseño de Equipo , Flúor/química , Criptón/química
15.
Opt Express ; 19(11): 10997-1006, 2011 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-21643361

RESUMEN

Improved spectral resolutions were achieved in laser-induced breakdown spectroscopy (LIBS) through generation of high-temperature and low-density plasmas. A first pulse from a KrF excimer laser was used to produce particles by perpendicularly irradiating targets in air. A second pulse from a 532 nm Nd:YAG laser was introduced parallel to the sample surface to reablate the particles. Optical scattering from the first-pulse plasmas was imaged to elucidate particle formation in the plasmas. Narrower line widths (full width at half maximums: FWHMs) and weaker self-absorption were observed from time-integrated LIBS spectra. Estimation of plasma temperatures and densities indicates that high temperature and low density can be achieved simultaneously in plasmas to improve LIBS resolutions.

16.
Opt Express ; 19(15): 14067-75, 2011 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-21934768

RESUMEN

To enhance optical emission in laser-induced breakdown spectroscopy, both a pair of permanent magnets and an aluminum hemispherical cavity (diameter: 11.1 mm) were used simultaneously to magnetically and spatially confine plasmas produced by a KrF excimer laser in air from pure metal and alloyed samples. High enhancement factors of about 22 and 24 in the emission intensity of Co and Cr lines were acquired at a laser fluence of 6.2 J/cm2 using the combined confinement, while enhancement factors of only about 11 and 12 were obtained just with a cavity. The mechanism of enhanced optical emission by combined confinement, including shock wave in the presence of a magnetic field, is discussed. The Si plasmas, however, were not influenced by the presence of magnets as Si is hard to ablate and ionize and hence has less free electrons and positive ions. Images of the laser-induced Cr and Si plasmas show the difference between pure metallic and semiconductor materials in the presence of both a cavity and magnets.

17.
Eur Rev Med Pharmacol Sci ; 20(18): 3877-3885, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27735027

RESUMEN

OBJECTIVE: These case series present a retrospective analysis of clinical effects that an allogeneic amniotic cell transplantation can have in treating 4 patients with type 2 diabetes. PATIENTS AND METHODS: Eligible diabetic patients were onset within 3 years, with fasting blood glucose > 7.0 mmol/l. Stem - cells that are collected from neonatal amniotic membrane when a child is born (2 x 107 cells) - are used for the treatment of these patients. Measured by the flow cytometry, stem cells transfer clusters of differentiation CD113 and CD34 at a high level, and through the femoral artery on the left, they are administered into the patient's pancreatic dorsal artery. RESULTS: The major outcome of the study is the improvement of glycemic control. After withdrawing insulin completely, 13.2 months later, there is a reincrease in the level of blood glucose of the patient. After adjusting their treatment again, no one required using insulin again; only need metformin (250-500 mg/day) to control blood glucose levels. CONCLUSIONS: Since this therapy showed no effects on C-peptide, our results suggested one plausible therapeutic strategy improving glycemic control by increasing insulin sensitivity.


Asunto(s)
Diabetes Mellitus Tipo 2/orina , Trasplante de Células Madre , Adulto , Glucemia/metabolismo , Femenino , Estudios de Seguimiento , Humanos , Hipoglucemiantes/administración & dosificación , Insulina , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
18.
Eur Rev Med Pharmacol Sci ; 19(19): 3643-8, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26502854

RESUMEN

OBJECTIVE: To evaluate the factors that may have an impact on the prognosis of ischemic stroke. PATIENTS AND METHODS: The study included 973 patients who were diagnosed with an ischemic stroke. The patients were divided into 6 groups according their eosinophil counts' level and occurred times. All patients were supervised by NIHSS score in three months. RESULTS: Baseline characteristics of all study groups were comparable. Thirty-four patients in group 2 and group 5 had higher eosinophil counts. In addition, the patients experienced impaired function on the face, but no impairment of limbs. All patients in these groups recovered quicker than the other groups (p < 0.05). Furthermore, 169 patients in both group 3 and group 6 had lower eosinophil counts. These patients experienced functional impairment in limbs and difficulty recovering from the disease. The NIHSS score was lower in both group 2 and group 5, compared with group 3 and group 6 (p < 0.05). CONCLUSIONS: This study suggests that eosinophil counts may have a significant impact on outcomes in stroke patients. The data underscore the importance in further investigating eosinophil dysregulation as well as the potential relationship between eosinophil dysregulation and organ functions in stroke patients.


Asunto(s)
Eosinófilos/fisiología , Accidente Cerebrovascular/sangre , Accidente Cerebrovascular/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Recuento de Leucocitos/métodos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Activación Plaquetaria/fisiología , Pronóstico
19.
Bioresour Technol ; 87(3): 341-7, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12507877

RESUMEN

The effects of planting three eucalypt species and irrigating with meatworks effluent on soil were assessed during the first 3-year rotation of a short rotation forest regime at Oringi, Dannevirke, New Zealand. The results showed tree planting alone reduced the soil infiltration rates, but had little influence on soil nutrient concentration other than reduction of nitrate levels. Species variation had limited influence on soil change. Effluent irrigation relieved the reduction of infiltration rates by tree planting, and increased nutrient concentrations, but reduced the soil pH. These changes should be considered when managing eucalypt short rotation forests sustainably in the longer term, either linked with effluent irrigation or not.


Asunto(s)
Eucalyptus , Suelo , Abastecimiento de Agua , Agricultura , Concentración de Iones de Hidrógeno , Nueva Zelanda , Nitratos/análisis , Árboles
20.
Bioresour Technol ; 85(3): 273-83, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12365495

RESUMEN

Accumulation of biomass and nutrients (N, P, K, Ca, Mg and Mn) was measured during the first 3-year rotation of three Eucalyptus short rotation forest species (E. botryoides, E. globulus and E. ovata) irrigated with meatworks effluent compared with no irrigation. E. globulus had the highest biomass and nutrient accumulation either irrigated with effluent or without irrigation. After 3-year growth, E. globulus stands irrigated with effluent accumulated 72 oven dry t/ha of above-ground total biomass with a total of 651 kg N, 55 kg P, 393 kg K, 251 kg Ca, 35 kg Mg and 67 kg Mn. Effluent irrigation increased the accumulation of biomass, N, P, K and Mn, but tended to reduce the leaf area index and leaf biomass, and decreased the accumulation of Ca and Mg.


Asunto(s)
Biomasa , Ecosistema , Eucalyptus/crecimiento & desarrollo , Eucalyptus/metabolismo , Fertilizantes , Árboles/metabolismo , Mataderos , Calcio/metabolismo , Eucalyptus/clasificación , Agricultura Forestal/métodos , Magnesio/metabolismo , Manganeso/metabolismo , Nueva Zelanda , Nitrógeno/metabolismo , Fósforo/metabolismo , Potasio/metabolismo , Eliminación de Residuos/métodos , Sensibilidad y Especificidad , Especificidad de la Especie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA