Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Nature ; 606(7914): 467-468, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35705815
2.
Phys Rev Lett ; 127(11): 112501, 2021 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-34558921

RESUMEN

High-accuracy mass measurements of neutron-deficient Yb isotopes have been performed at TRIUMF using TITAN's multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS). For the first time, an MR-TOF-MS was used on line simultaneously as an isobar separator and as a mass spectrometer, extending the measurements to two isotopes further away from stability than otherwise possible. The ground state masses of ^{150,153}Yb and the excitation energy of ^{151}Yb^{m} were measured for the first time. As a result, the persistence of the N=82 shell with almost unmodified shell gap energies is established up to the proton drip line. Furthermore, the puzzling systematics of the h_{11/2}-excited isomeric states of the N=81 isotones are unraveled using state-of-the-art mean field calculations.

3.
Phys Rev Lett ; 113(12): 120405, 2014 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-25279611

RESUMEN

We present the concluding result from an Ives-Stilwell-type time dilation experiment using 7Li+ ions confined at a velocity of ß=v/c=0.338 in the storage ring ESR at Darmstadt. A Λ-type three-level system within the hyperfine structure of the 7Li+3S1 →3P2 line is driven by two laser beams aligned parallel and antiparallel relative to the ion beam. The lasers' Doppler shifted frequencies required for resonance are measured with an accuracy of <4×10(-9) using optical-optical double resonance spectroscopy. This allows us to verify the special relativity relation between the time dilation factor γ and the velocity ß, γ√1-ß2=1 to within ±2.3×10(-9) at this velocity. The result, which is singled out by a high boost velocity ß, is also interpreted within Lorentz invariance violating test theories.

4.
Phys Rev Lett ; 96(6): 063401, 2006 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-16605991

RESUMEN

A new determination of the decay rate of the negative ion of positronium (Ps-), using a beam-foil method and a stripping-based detection technique, is reported. The measured result of gamma = 2.089(15) ns(-1) is a factor of 6 more precise than the previous experimental value of gamma = 2.09(9) ns(-1), and is in excellent agreement with the theoretical value of gamma = 2.086(6) ns(-1).

5.
Phys Rev Lett ; 95(24): 243201, 2005 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-16384374

RESUMEN

Electron-ion recombination observed in storage ring experiments shows a strong enhancement relative to what standard radiative recombination rates predict. We simulate the effect of a transient motional electric field induced by the merging of an electron and an ion beam in the electron cooler which opens an additional pathway for free-bound transitions of electrons. We show that the measured rate contains a significant contribution from radiative stabilization of Rydberg states formed by this transient motional electric field. The absolute excess recombination rates obtained are in good agreement with the experimental data. The scaling of the rate with the ion charge and the magnetic guiding field is analyzed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA