Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am Heart J ; 269: 108-117, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38128897

RESUMEN

Hypertension remains a leading preventable cause of myocardial infarction, stroke, kidney disease, and cardiovascular death worldwide. Despite lifestyle modifications and intensification of medical therapy, suboptimal blood pressure control is common, spurring the development of device-based therapies for hypertension. The US Food and Drug Administration (FDA) assembled the Circulatory System Devices Panel on August 22-23, 2023, to discuss the safety and effectiveness of renal denervation devices manufactured by Recor Medical and Medtronic. After reviewing the ultrasound-based Recor Paradise renal denervation system the day prior, the panel reconvened to discuss the radiofrequency-based Medtronic Symplicity Spyral Renal Denervation System. In this manuscript, we summarize the data presented by the sponsor and FDA and detail the deliberation and discussion during the meeting.


Asunto(s)
Sistema Cardiovascular , Hipertensión , Estados Unidos , Humanos , United States Food and Drug Administration , Riñón/cirugía , Presión Sanguínea , Simpatectomía , Resultado del Tratamiento , Antihipertensivos/uso terapéutico
2.
Am Heart J ; 275: 21-34, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38815781

RESUMEN

Tricuspid regurgitation (TR) is common and associated with significant mortality and morbidity. Because the effectiveness and safety of medical and surgical treatments are limited, there is a significant unmet need for the treatment of this disease. Therefore, there is a growing market for percutaneous devices that offer safer, less invasive, and more effective treatment options in this patient population. On February 13, 2024, the US Food and Drug Administration (FDA) convened a meeting of the Circulatory System Devices Panel to discuss the safety and effectiveness of the TriClip Transcatheter Valve Repair System (Abbott, Santa Clara, CA, USA). Several important points were discussed, including newly published data from the TRILUMINATE Pivotal study, the use of patient-oriented outcomes for device approval, and a discussion about training requirements and rollout plans when approving a breakthrough device. In this manuscript, we summarize the data presented by the sponsor and FDA and describe the deliberations and discussions during the meeting.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38860616

RESUMEN

In the absence of standardized management guidelines, coronary artery aneurysms (CAAs) present therapeutic challenges. Percutaneous coronary intervention (PCI) is rarely explored, especially in giant aneurysms with persistent angina, where surgery might be presumed as a preferred option. We describe the technical aspects and feasibility of PCI using Gore Viabahn expanded polytetrafluoroethylene (ePTFE)-covered nitinol self-expanding stents in a 66-year-old woman with a complex medical history and an enlarging, symptomatic right coronary artery aneurysm. The case was complicated by endoleak after the first stent, but intravascular ultrasound guidance enabled the precise deployment of additional stents, resulting in the successful exclusion of the aneurysm. This case demonstrates steps to successful CAA PCI with Gore Viabahn ePTFE-covered nitinol self-expanding stents and emphasizes that in unsuitable surgical candidates, PCI might be a potential alternative for symptomatic CAAs.

4.
Catheter Cardiovasc Interv ; 104(1): 34-43, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38713867

RESUMEN

Hypertension continues to be a prominent, avoidable factor contributing to major vascular issues on a global scale. Even with lifestyle adjustments and more aggressive medical treatments, maintaining optimal blood pressure levels remains challenging. This challenge has driven the emergence of device-oriented approaches to address hypertension. To assess the safety and efficacy of the Recor Paradise Ultrasound Renal Denervation System, the Circulatory System Devices Panel was convened by the US Food and Drug Administration (FDA). This manuscript provides a condensed overview of the information put forth by the sponsor and the FDA, along with an account of the considerations and conversations that took place during the meeting.


Asunto(s)
Presión Sanguínea , Aprobación de Recursos , Hipertensión , Arteria Renal , Simpatectomía , United States Food and Drug Administration , Humanos , Estados Unidos , Simpatectomía/efectos adversos , Simpatectomía/instrumentación , Hipertensión/fisiopatología , Hipertensión/cirugía , Arteria Renal/inervación , Arteria Renal/diagnóstico por imagen , Resultado del Tratamiento , Riñón/irrigación sanguínea , Comités Consultivos , Diseño de Equipo , Factores de Riesgo
5.
Artículo en Inglés | MEDLINE | ID: mdl-38736245

RESUMEN

BACKGROUND: Malnutrition is associated with poor prognosis in several cardiovascular diseases; however, its role in patients with secondary mitral regurgitation (SMR) is poorly known. AIMS: To evaluate the impact of nutritional status, assessed using different scores, on clinical outcomes in patients with SMR undergoing transcatheter edge-to-edge repair (TEER) in a real-world setting. METHODS: A total of 658 patients with SMR and complete nutritional data were identified from the MIVNUT registry. Nutritional status has been assessed using controlling nutritional status index (CONUT), prognostic nutritional index (PNI), and geriatric nutritional risk index (GNRI) scores. Outcomes of interest were all-cause mortality and all-cause mortality or heart failure (HF) hospitalization. RESULTS: Any malnutrition grade was observed in 79.4%, 16.7%, and 47.9% of patients by using CONUT, PNI, and GNRI, respectively, while moderate to severe malnutrition was noted in 24.7%, 16.7%, and 25.6% of patients, respectively. At a median follow-up of 2.2 years, 212 patients (32.2%) died. Moderate-severe malnutrition was associated with a higher rate of all-cause mortality (HR: 2.46 [95% CI: 1.69-3.58], HR: 2.18 [95% CI: 1.46-3.26], HR: 1.97 [95% CI: 1.41-2.74] for CONUT, PNI, and GNRI scores, respectively). The combined secondary endpoint of all-cause mortality and HF rehospitalization occurred in 306 patients (46.5%). Patients with moderate-severe malnutrition had a higher risk of the composite endpoint (HR: 1.56 [95% CI: 1.20-2.28], HR: 1.55 [95% CI: 1.01-2.19], HR: 1.36 [95% CI: 1.02-1.80] for CONUT, PNI, and GNRI scores, respectively). After adjustment for multiple confounders, moderate-severe malnutrition remained independently associated with clinical outcomes. CONCLUSIONS: Moderate-severe malnutrition was common in patients with SMR undergoing TEER. It was independently associated with poor prognosis regardless of the different scores used.

6.
BMC Cardiovasc Disord ; 23(1): 304, 2023 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-37328829

RESUMEN

BACKGROUND: Transcatheter edge to edge repair (TEER) improves prognosis in patients with functional mitral regurgitation (FMR) receiving guideline directed medical therapy (GDMT). Many patients with FMR do not receive GDMT and the utility of TEER in this population remains unclear. METHODS: We retrospectively studied patients undergoing TEER. Clinical, echocardiographic and procedural variables were recorded. GDMT was defined as use of RAAS inhibitors and MRAs unless GFR was under 30 as well as beta blockers. The primary endpoint of the study was one year mortality. RESULTS: 168 patients (mean age 71.3 ± 9.3; 66% males) with FMR who underwent TEER were included of whom 116 (69%) received GDMT at the time of TEER and 52 (31%) did not. There were no significant demographic or clinical differences between the groups. There were no significant differences in procedural success and complications between groups. One year mortality was identical in the two groups (15% vs. 15%; RR 1.06, CI 0.43-2.63, P = 0.90). CONCLUSIONS: Our findings suggest that procedural success and one year mortality following TEER was not significantly different in HFREF patients with FMR with or without GDMT. Larger, prospective studies are necessary to define the benefit of TEER in this population.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Israel , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento
7.
Eur Heart J ; 43(7): 641-650, 2022 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-34463727

RESUMEN

AIMS: Severe mitral regurgitation (MR) following acute myocardial infarction (MI) is associated with high mortality rates and has inconclusive recommendations in clinical guidelines. We aimed to report the international experience of patients with secondary MR following acute MI and compare the outcomes of those treated conservatively, surgically, and percutaneously. METHODS AND RESULTS: Retrospective international registry of consecutive patients with at least moderate-to-severe MR following MI treated in 21 centres in North America, Europe, and the Middle East. The registry included patients treated conservatively and those having surgical mitral valve repair or replacement (SMVR) or percutaneous mitral valve repair (PMVR) using edge-to-edge repair. The primary endpoint was in-hospital mortality. A total of 471 patients were included (43% female, age 73 ± 11 years): 205 underwent interventions, of whom 106 were SMVR and 99 PMVR. Patients who underwent mitral valve intervention were in a worse clinical state (Killip class ≥3 in 60% vs. 43%, P < 0.01), but yet had lower in-hospital and 1-year mortality compared with those treated conservatively [11% vs. 27%, P < 0.01 and 16% vs. 35%, P < 0.01; adjusted hazard ratio (HR) 0.28, 95% confidence interval (CI) 0.18-0.46, P < 0.01]. Surgical mitral valve repair or replacement was performed earlier than PMVR [median of 12 days from MI date (interquartile range 5-19) vs. 19 days (10-40), P < 0.01]. The immediate procedural success did not differ between SMVR and PMVR (92% vs. 93%, P = 0.53). However, in-hospital and 1-year mortality rates were significantly higher in SMVR than in PMVR (16% vs. 6%, P = 0.03 and 31% vs. 17%, P = 0.04; adjusted HR 3.75, 95% CI 1.55-9.07, P < 0.01). CONCLUSIONS: Early intervention may mitigate the poor prognosis associated with conservative therapy in patients with post-MI MR. Percutaneous mitral valve repair can serve as an alternative for surgery in reducing MR for high-risk patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Anciano , Anciano de 80 o más Años , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Infarto del Miocardio/complicaciones , Infarto del Miocardio/terapia , Estudios Retrospectivos , Resultado del Tratamiento
8.
Isr Med Assoc J ; 24(3): 191-197, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35347935

RESUMEN

BACKGROUND: The pathogenesis of atherosclerosis is multifactorial, mainly driven by complex inflammatory processes. Colchicine is an anti-inflammatory drug used in a variety of clinical settings. The purpose of this review is to evaluate the role of colchicine in atherosclerotic vascular disease and more specifically, its promising impact on the outcome of patients with stable and acute coronary syndrome and to review its effect in patients undergoing angioplasty. A literature review was performed using the search terms colchicine, coronary heart disease, or acute coronary syndrome, stable coronary disease. We accessed PubMed, Google scholar, and the Cochrane Library databases to search for studies. Patients with chronic coronary disease may benefit from treatment with low dose colchicine to reduce the occurrence of a cardiovascular event. Among patients with a recent myocardial infarction, colchicine treatment was associated with reduced ischemic cardiovascular events, although without a meaningful difference in mortality. Colchicine was found to be a promising agent that can be potentially integrated into the armamentarium of treatments for patients with atherosclerotic coronary disease pending careful patient selection.


Asunto(s)
Síndrome Coronario Agudo , Aterosclerosis , Síndrome Coronario Agudo/complicaciones , Antiinflamatorios/uso terapéutico , Aterosclerosis/tratamiento farmacológico , Colchicina/uso terapéutico , Humanos
9.
Catheter Cardiovasc Interv ; 98(1): E139-E144, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33058433

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation related thrombocytopenia (TAVI-rTP) is an inevitable phenomenon. However, no study has been performed on TAVI-rTP in the current setting of extended clinical indications combined with technology improvements. METHODS: Patients with severe symptomatic aortic stenosis who underwent transfemoral TAVI, from January 2016 to December 2019 were enrolled. RESULTS: Two-hundred and one consecutive patients (mean age 81.1 ± 7.1 years, 96 men) enrolled. Platelet count was recorded before and after aortic valve implantation. Dropped platelet count (DPC) occurred in all but 11 patients who were included. Two groups were created: DPC <30 and DPC ≥30%. DPC was compared with in-hospital major adverse cardiovascular events. The mean DPC was 26 ± 14%. We found that 67 patients (33.3%) had DPC of more or equal to 30%. In the univariable analysis, the time of the procedure (94.4 ± 32.7 vs 79.4 ± 21.9, p = .002), the amount of the contrast used (125.4 ± 55.4 vs 108.4 ± 44.1, p = .02) and the residual AV gradient (13.3 ± 7.2 vs 14.7, p = .05) were related to a DCP ≥30%. A DPC ≥30% was associated with increased risk of life-threatening/major bleeding (11.9% vs 1.5%, p = .001), major vascular complications (16.4% vs 5.2% p = .009) and death (3.0% vs 0%, p = .044) at 30 days. After multivariable analysis, the factors associated with a higher DPC were time and contrast. CONCLUSION: Contemporary TAVI-rTP in this cohort of patients continues to be a common phenomenon but severe thrombocytopenia is less frequent. Patients developing a DPC ≥30% are associated with poor outcomes at 30 days.


Asunto(s)
Estenosis de la Válvula Aórtica , Trombocitopenia , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Factores de Riesgo , Trombocitopenia/inducido químicamente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 97(6): 1259-1267, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33600072

RESUMEN

OBJECTIVES: To assess outcomes in patients with acute mitral regurgitation (MR) following acute myocardial infarction (AMI) who received percutaneous mitral valve repair (PMVR) with the MitraClip device and to compare outcomes of patients who developed cardiogenic shock (CS) to those who did not (non-CS). BACKGROUND: Acute MR after AMI may lead to CS and is associated with high mortality. METHODS: This registry analyzed patients with MR after AMI who were treated with MitraClip at 18 centers within eight countries between January 2016 and February 2020. Patients were stratified into CS and non-CS groups. Primary outcomes were mortality and rehospitalization due to heart failure. Secondary outcomes were acute procedural success, functional improvement, and MR reduction. Multivariable Cox regression analysis evaluated association of CS with clinical outcomes. RESULTS: Among 93 patients analyzed (age 70.3 ± 10.2 years), 50 patients (53.8%) experienced CS before PMVR. Mortality at 30 days (10% CS vs. 2.3% non-CS; p = .212) did not differ between groups. After median follow-up of 7 months (IQR 2.5-17 months), the combined event mortality/re-hospitalization was similar (28% CS vs. 25.6% non-CS; p = .793). Likewise, immediate procedural success (90% CS vs. 93% non-CS; p = .793) and need for reintervention (CS 6% vs. non-CS 2.3%, p = .621) or re-admission due to HF (CS 13% vs. NCS 23%, p = .253) at 3 months did not differ. CS was not independently associated with the combined end-point (hazard ratio 1.1; 95% CI, 0.3-4.6; p = .889). CONCLUSIONS: Patients found to have significant MR during their index hospitalization for AMI had similar clinical outcomes with PMVR whether they presented in or out of cardiogenic shock, provided initial hemodynamic stabilization was first achieved before PMVR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Anciano , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Infarto del Miocardio/complicaciones , Sistema de Registros , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Resultado del Tratamiento
11.
Isr Med Assoc J ; 23(10): 657-661, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34672449

RESUMEN

BACKGROUND: Anti-endothelial cell antibodies (AECA) are a known biomarker of endothelial dysfunction and damage in clinical practice, especially in autoimmune disease. OBJECTIVES: To determine the relation between natural AECA levels and prognosis related to coronary artery disease. METHODS: Candidates for coronary angiography were prospectively enrolled. AECA levels were determined by ELISA assay. Mortality was evaluated after more than 5 years follow-up. RESULTS: Of a total 857 patients, 445 had high AECA levels (group 1) and 412 had low levels (< 1 OD unit, group 2). Both groups did not differ in age, sex, or presence of diabetes. The median follow up was 2293 days (76 months). Patients with high AECA levels were more likely to have normal coronary arteries on angiography (21.6% vs. 16.9%, P = 0.047) and less likely to have calcified lesions (19.0% vs. 26.6%, P = 0.028) and lower prevalence of abnormal renal functions (71.1 mg/dl vs. 66.5 mg/dl, P = 0.033). Patients with higher AECA levels had lower mortality levels (20.1% vs. 27.6%, P = 0.006). A logistic regression model demonstrated independent association between lower AECA levels and the presence of coronary atherosclerosis based on angiogram. CONCLUSIONS: After a median of more than 6 years, higher natural AECA levels were associated with less coronary artery disease and lower mortality rates in patients undergoing coronary angiography.


Asunto(s)
Autoanticuerpos/sangre , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Endotelio Vascular , Anciano , Biomarcadores/sangre , Angiografía Coronaria/métodos , Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/inmunología , Enfermedad de la Arteria Coronaria/mortalidad , Endotelio Vascular/inmunología , Endotelio Vascular/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Pruebas Inmunológicas/métodos , Israel/epidemiología , Masculino , Pronóstico , Factores Protectores , Reproducibilidad de los Resultados , Medición de Riesgo/métodos
12.
BMC Nephrol ; 21(1): 445, 2020 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-33097001

RESUMEN

BACKGROUND: Chronic kidney disease (CKD) is associated with poorer outcomes following percutaneous coronary intervention (PCI) with drug-eluting stents. Drug-eluting balloons are used for in-stent restenosis and selected cases of de-novo coronary lesions. Little is known regarding the outcomes of individuals with CKD who undergo PCI with drug-eluting balloons. The goal of this study was to assess outcomes of PCI with drug-eluting balloons in individuals with CKD. METHODS: In a retrospective analysis, outcomes of PCI with drug-eluting balloons were compared between 101 patients with CKD and 261 without CKD. CKD was defined as estimated glomerular filtration rate < 60 ml/min/1.73m2. We compared demographics, procedure data and clinical outcomes in the first and second years following the procedure. RESULTS: Rates of major adverse cardiac events (MACE) and myocardial infarction were higher in patients with than without CKD: 23.8% vs. 13.8%, P < 0.005 and 15.9% vs. 3.8%, P < 0.001, respectively. Rates of target lesion revascularization were similar, 14.9 and 11.5%, respectively, P = 0.4. Shorter duration of dual anti-platelet therapy was observed among patients with than without CKD (10.0 + 3.4 vs. 10.9 + 3.7 months, P < 0.05). First-year hemorrhage episodes were similar in the two groups (0.08 ± 0.4 and 0.03 ± 0.2, respectively, P = 0.2). In a multivariate regression analysis, CKD was associated with increased risks of first year MACE (OR 2.1; 95% confidence interval 1.0-4.3, P < 0.001). CONCLUSIONS: PCI with drug-eluting balloons was associated with increased cardiovascular morbidity and mortality in patients with than without CKD. However, rates of target lesion revascularization were similar in the two groups. Shorter duration of dual anti-platelet therapy was observed in the CKD group.


Asunto(s)
Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Insuficiencia Renal Crónica/complicaciones , Anciano , Esquema de Medicación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complicaciones Posoperatorias , Análisis de Regresión , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
13.
Am J Nephrol ; 50(6): 465-472, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31655801

RESUMEN

BACKGROUND: Chronic kidney disease (CKD) is associated with an increased risk of adverse cardiovascular outcomes, in patients with coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI). However, most studies used bare-metal stents or first-generation drug-eluting stents, and less guideline-directed therapy to reduce cardiovascular risk was reported in CKD patients. This study investigates the impact of moderate-CKD on patients undergoing PCI in the current era. METHODS: Patient level data were pooled from 2 multicenter randomized trials (BIONICS and NIREUS trials) with a near "all-comers" design, comparing PCI with ridaforolimus-eluting stents vs. zotarolimus-eluting stents in patients with CAD. Patients were classified according to the presence or absence of moderate-CKD, defined as creatinine clearance (CrCl) <60 mL/min. We compared baseline characteristics, angiographic findings, and clinical outcomes 1-year post-PCI. RESULTS: 236/2,201 (10.7%) patients had CKD, mean CrCl of 50.3 + 7.8 mL/min. These patients were generally older and more often with hypertension than non-CKD patients, but the use of guideline-directed therapy was similar between the groups. CKD was associated with an increased risk of cardiovascular death (hazard ratio [HR] 6.08; 95% CI 2.11-17.51; p < 0.001), but with a reduced occurrence of repeated revascularization, including ischemia-driven revascularization (HR 0.47; 95% CI 0.24-0.92; p < 0.05). The rate of repeated angiography per severe cardiovascular adverse event was significantly lower in the CKD than the non-CKD group (23/38 [61%] vs. 253/334 [76%], p < 0.05). CONCLUSIONS: Moderate-CKD in patients with CAD was associated with higher rates of all-cause and cardiovascular mortality, yet with a lower risk of revascularization 1-year following PCI. Lack of guideline-directed medical therapy does not explain the adverse outcome of CKD patients.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/estadística & datos numéricos , Insuficiencia Renal Crónica/epidemiología , Reoperación/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Angiografía/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Stents Liberadores de Fármacos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Intervención Coronaria Percutánea/instrumentación , Periodo Posoperatorio , Ensayos Clínicos Controlados Aleatorios como Asunto , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
14.
Cardiovasc Revasc Med ; 65: 75-80, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38565427

RESUMEN

Transcatheter heart valve (THV) procedures require careful planning and consideration to prevent coronary artery obstruction (CAO), which poses a significant and potentially life-threatening condition, especially in patients undergoing valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). Despite identifying predictors of CAO and utilization of computed tomography and inputting THV features, a significant uncertainty remains in predicting CAO. The ShortCut™ device (Pi-Cardia, Rehovot, Israel) was purposefully designed to modify the leaflets in patients undergoing TAVR, especially prior to ViV procedures, to overcome the risk for CAO. This review aims to detail the device's objectives, structure, procedural steps, the available clinical data, and future directions for its intended utilization in the structural arena for the prevention of CAO.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Oclusión Coronaria , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/prevención & control , Oclusión Coronaria/etiología , Oclusión Coronaria/terapia , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología
15.
Am J Cardiol ; 225: 52-60, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38906395

RESUMEN

Spontaneous coronary artery dissection (SCAD) is a rare cause of ST-segment elevation myocardial infarction (STEMI), predominantly affecting women. Because primary percutaneous coronary intervention (PPCI) is reserved for a select group of patients, vulnerable and minority patients may experience delays in appropriate management and adverse outcomes. We examined the racial differences in the outcomes for patients with SCAD who underwent PPCI for STEMI. Records of patients aged ≥18 years who underwent PPCI for SCAD-related STEMI between 2016 and 2020 were identified from the National Inpatient Sample database. Clinical, socioeconomic, and hospital characteristics were compared between non-White and White patients. Weighted multivariate analysis assessed the association of race with inpatient mortality, length of stay (LOS), and hospitalization costs. The total weighted estimate of patients with SCAD-STEMI who underwent PPCI was 4,945, constituting 25% non-White patients. Non-White patients were younger (56 vs 60.7 years, p <0.001); had a higher prevalence of diabetes, acute renal failure, and obesity; and were more likely to be uninsured and be in the lowest income group. Inpatient mortality (7.7% vs 8.4%, p = 0.74) and hospitalization costs ($34,213 vs $31,858, p = 0.27) were similar for non-White and White patients, and the adjusted analysis did not show any association between the patients' race and inpatient mortality (odds ratio 0.60, 95% confidence interval [CI] 0.32 to 1.13, p = 0.11) or hospitalization costs (ß [ß coefficient]: 215, 95% CI -4,193 to 4,623, p >0.90). Similarly, there was no association between the patients' race and LOS (incident rate ratio 1.20, 95% CI 1.00 to 1.45, p = 0.054). The weighted multivariate analysis showed that age; clinical co-morbidities such as diabetes, acute renal failure, valvular dysfunction, and obesity; low-income status; and hospitalization in the western region were associated with adverse outcomes. In conclusion, our study does not show any differences in inpatient mortality, LOS, and hospitalization costs between non-White and White patients who underwent PPCI for SCAD-related STEMI.

16.
Circ Cardiovasc Interv ; 17(7): e014143, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38853766

RESUMEN

Bioprosthetic aortic valve thrombosis is frequently detected after transcatheter and surgical aortic valve replacement due to advances in cardiac computed tomography angiography technology and standardized surveillance protocols in low-surgical-risk transcatheter aortic valve replacement trials. However, evidence is limited concerning whether subclinical leaflet thrombosis leads to clinical adverse events or premature structural valve deterioration. Furthermore, there may be net harm in the form of bleeding from aggressive antithrombotic treatment in patients with subclinical leaflet thrombosis. This review will discuss the incidence, mechanisms, diagnosis, and optimal management of bioprosthetic aortic valve thrombosis after transcatheter aortic valve replacement and bioprosthetic surgical aortic valve replacement.


Asunto(s)
Válvula Aórtica , Bioprótesis , Fibrinolíticos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Prótesis Valvulares Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/terapia , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Fibrinolíticos/efectos adversos , Fibrinolíticos/administración & dosificación , Incidencia , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Anticoagulantes/administración & dosificación , Medición de Riesgo , Valor Predictivo de las Pruebas
17.
Artículo en Inglés | MEDLINE | ID: mdl-39013705

RESUMEN

BACKGROUND: PROTECT IV is a current enrolling randomized controlled trial evaluating high-risk percutaneous coronary intervention (HR-PCI) with prophylactic Impella versus no Impella to reduce the composite primary endpoint of all-cause death, stroke, myocardial infarction (MI), or cardiovascular hospitalization. In a PROTECT IV-like cohort of patients who underwent HR-PCI without Impella, we aimed to report the rate of major adverse events to determine whether the trial is adequately powered. METHODS AND RESULTS: A total of 700 patients meeting similar inclusion/exclusion criteria of PROTECT IV who underwent HR-PCI without Impella at a single tertiary center from 2008 to 2022 were included in the analysis. The composite rates of all-cause death, MI, target lesion revascularization, and target vessel revascularization at 1, 2, and 3 years were estimated using the Kaplan-Meier method, and the results were used to calculate the sample size under the constant hazard ratio assumption and expected number of events to be observed used in planning PROTECT IV. The primary endpoint occurred in 30.8 % of patients at 2 years. PROTECT IV assumes a hazard ratio of 0.75 using a multivariate Cox regression, which, under a 5 % level and 90 % power, yields 516 events. This implies a 2-year primary outcome rate of 50 % for the non-Impella arm. CONCLUSION: Therefore, PROTECT IV estimates that a sample size of 1252 patients is required for Impella to be declared superior to the non-Impella group. Using our observed 2-year outcome of 30.8 %, we estimate that PROTECT IV requires 1966 patients, demonstrating that PROTECT IV is probably underpowered.

18.
ESC Heart Fail ; 11(2): 1218-1227, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38303542

RESUMEN

AIMS: Acute mitral regurgitation (MR) in the setting of myocardial infarction (MI) may be the result of papillary muscle rupture (PMR). This condition is associated with high morbidity and mortality. We aim to evaluate the feasibility of transcatheter edge-to-edge mitral valve repair (TEER) in this acute setting. METHODS AND RESULTS: We analysed data from the International Registry of MitraClip in Acute Mitral Regurgitation following acute Myocardial Infarction (IREMMI) of 30 centres in Europe, North America, and the middle east. We included patients with post-MI PMR treated with TEER as a salvage procedure, and we evaluated immediate and 30-day outcomes. Twenty-three patients were included in this analysis (9 patients suffered complete papillary muscle rupture, 9 partial and 5 chordal rupture). The patients' mean age was 68 ± 14 years. Patients were at high surgical risk with median EuroSCORE II 27% (IQR 16, 28) and 20 out of 23 (87% were in cardiogenic shock). All patients were treated with vasopressors, and 17 out of 23 patients required mechanical support. TEER procedure was performed on the median 6 days after the index MI date IQR (3, 11). Procedural success was achieved in 87% of patients. The grade of MR was significantly decreased after the procedure. MR reduction to 0 or 1 + was achieved in 13 patients (57%), to 2 + in 7 patients (30%), P < 0.01. V-Wave was reduced from 49 ± 8 mmHg to 26 ± 10 mmHg post-procedure, P < 0.01. Sixteen out of 23 patients (70%) were discharged from hospital and 5 of them required reintervention with surgical mitral valve replacement. No additional death at 1 year was documented. CONCLUSIONS: TEER is a feasible therapy in critically ill patients with PMR due to a recent MI. TEER may have a role as salvage treatment or bridge to surgery in this population.


Asunto(s)
Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Músculos Papilares , Infarto del Miocardio/complicaciones , Choque Cardiogénico/etiología
19.
Coron Artery Dis ; 34(6): 410-414, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37471280

RESUMEN

BACKGROUND: The ridaforolimus-eluting stent (RES) system is a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting ridaforolimus. The aim of this trial was to assess the performance of a 38 mm RES in long coronary lesions. METHODS: A prospective, multicenter, single-arm, open-label clinical trial. Clinical follow-up was performed at 30 days, 6 months, and 1 year after the procedure. Target lesions were located in native coronary arteries or bypass graft conduits, with visually estimated diameters of ≥2.75 mm to ≤4.25 mm. The primary endpoint was combined efficacy (final in-stent residual diameter stenosis <30%) without 30-day major adverse cardiovascular events (MACE) (composite of cardiac death, any myocardial infarction), or ischemia-driven target lesion revascularization. RESULTS: A total of 50 patients were enrolled in the study. Fourteen (28%) had acute coronary syndromes; 17 (34%) had diabetes. The mean lesion length was 32.4 mm ±â€…8.3, reference vessel diameter 2.88 mm ±â€…0.45, minimal lumen diameter 0.80 mm ±â€…0.41, and percent diameter stenosis 72.6% ±â€…13.2. The primary endpoint was achieved in 88% (44/50) of the patients (95% confidence interval: 75.7-95.5%). Thirty-day and 1-year MACE rates were 6% and 8%, respectively. Target lesion failure after 1 year occurred in three patients (6%). Forty-seven lesions (94%) were treated successfully, with final in-stent diameter stenosis of < 30% [95% confidence interval: (84-99%). CONCLUSION: Percutaneous coronary intervention (PCI) of long lesions with a 38 mm RES achieved satisfactory results, and support the safety and efficacy of PCI with RES in patients with long lesions. (ClinicalTrials.gov NCT03702608).


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Constricción Patológica , Estudios Prospectivos , Biónica , Stents , Resultado del Tratamiento
20.
J Pers Med ; 13(3)2023 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-36983740

RESUMEN

INTRODUCTION: Right heart catheterization (RHC) is a diagnostic procedure, the main purpose of which is to diagnose pulmonary hypertension and investigate its etiology and treatability. In addition to measuring blood pressure in heart chambers, it includes estimating cardiac output (CO) and calculation of pulmonary vascular resistance (PVR) derived from the CO. There are two common methods to evaluate the CO-the indirect Fick method and the thermodilution method. Depending on the clinical conditions, either of the two may be considered better. Several studies have showed that, in most cases, there is no difference between measurements rendered by the two methods. Other studies have raised suspicion of a discrepancy between the two methods in a substantial number of patients. A clear opinion on this matter is missing. AIM: To evaluate the agreement between the values of the CO and PVR found by the thermodilution and indirect Fick methods. METHODS: We retrospectively included patients that underwent RHC in Kaplan Medical Center during the last two years with a measurement of the CO using both the thermodilution and the indirect Fick methods. The measurements obtained upon RHC and the clinical data of the patients were collected. The values of the CO and PVR measured or calculated using the two methods were compared for each patient. RESULTS: We included 55 patients that met the inclusion criteria in this study. The mean CO measured by the thermodilution method was 4.94 ± 1.17 L/min and the mean CO measured by the indirect Fick method was 5.82 ± 1.97 L/min. The mean PVR calculated using the thermodilution method was 3.33 ± 3.04 Woods' units (WU) and the mean PVR calculated using the indirect Fick method was 2.71 ± 2.76 WU. Among the patients with normal mPAP, there was a strong and statistically significant correlation between the PVR values calculated by the two methods (Peasron's R2 = 0.78, p-value = 0.004), while among the patients with elevated mPAP, the correlation between the PVR values calculated by the two methods was not statistically significant. CONCLUSION: The findings of this small study demonstrate that, in a proportion of patients, the indirect Fick method and thermodilution method classify the PVR value differently. In our experience, it seems that, in these patients, the indirect Fick method misclassified patients with a pathological finding as normal. We, therefore, recommend that upon performing RHC, at least in patients with mPAP > 25 mmHg, both the thermodilution and indirect Fick methods be performed and, whenever they disagree, the values obtained from the thermodilution method should be preferred.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA