Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Clin Oral Investig ; 26(10): 6105-6118, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35641836

RESUMEN

OBJECTIVES: To evaluate the force delivered by removable thermoplastic appliances (RTAs, aligners), altered with Hilliard precision thermopliers, on an upper central incisor to tip it in the palatal and vestibular directions. MATERIALS AND METHODS: A total of 10 aligners made from Ideal Clear® (polyethylene terephthalate glycol copolyester, PET-G) with a thickness of 1 mm were used in force analysis. Different-sized spot-thermoformed protuberances (bumps) were generated by activating the thermoplier (thin and thick) up to 30°, 60° and 90° in the centre of the palatal and vestibular surfaces of the aligner in 15° steps. The tipping (Fx) and intrusive (Fz) force components were measured on the isolated upper central incisor as part of a standardized resin model, with or without vertical loading by a weight equivalent. RESULTS: Thermoplier activation at 30°, 60° and 90° resulted in different bump heights. The analysis revealed significantly higher Fx and Fz values with increasing bump heights for every activation step in all cases (p < 0.0001, respectively). Overall, the values of the Fx force component were higher than those observed for Fz. Significant differences between the palatal and vestibular tipping procedures were found depending on the resulting force components when the thin thermoplier was used; in contrast, the thick thermoplier resulted in a larger dispersion of the force magnitudes. CONCLUSIONS: Aligners modified with Hilliard precision thermopliers showed altered biomechanical parameters. This approach could be an option for treatment modification. CLINICAL RELEVANCE: The instrumental examination provided informative results for daily practice, as activation, force dosage and different force values under chewing pressure can be estimated more precisely based on the determined force levels.


Asunto(s)
Incisivo , Aparatos Ortodóncicos Removibles , Análisis del Estrés Dental/métodos , Diseño de Aparato Ortodóncico , Técnicas de Movimiento Dental
2.
BMC Oral Health ; 22(1): 318, 2022 07 30.
Artículo en Inglés | MEDLINE | ID: mdl-35907826

RESUMEN

BACKGROUND: To test the hypothesis that cephalometric parameters in two-dimensional routine dental radiographs correlate with the bone volume of intraoral bone donor sites. METHODS: One-hundred and eight radiographs [36 panoramic radiographs (PRs), 36 lateral cephalometric radiographs (LCRs), and 36 cone-beam computed tomography scans (CBCT)] of 36 patients (all three imaging techniques applied according to the needs of treatment planning), were analyzed individually. Cephalometric parameters (PR and LCR) were correlated with the bone volume measurement in three-dimensional CBCT scans in three intraoral donor sites (chin, mandibular retromolar region, and zygomatic alveolar crest). RESULTS: The mean bone volumes measured for the chin were (3.10 ± 1.11 cm³ SD), the mandibular retromolar region (1.66 ± 0.54 cm³ SD), and the zygomatic alveolar crest (0.17 ± 0.04 cm³ SD). Cephalometric parameters were significantly correlated (all p-values < 0.05) with the bone volume in the chin and the mandibular retromolar region. The bone volume of the zygomatic alveolar crest exhibited no correlations (p > 0.05) with cephalometric parameters. However, it was significantly correlated (p < 0.01) with the mandibular retromolar bone volume. No gender-specific differences (p > 0.05) were observed concerning bone volumes in all bone harvesting regions. Nevertheless, the male population's interforaminal distance in the chin region was significantly higher (p = 0.001). CONCLUSIONS: PRs and LCRs can be used at the initial stage of peri-implant augmentation planning to deduce conclusions about the bone volume in different intraoral bone donor sites. It can help describe indications and justify additional diagnostic options, such as three-dimensional radiologic techniques.


Asunto(s)
Tomografía Computarizada de Haz Cónico Espiral , Cefalometría/métodos , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Imagenología Tridimensional/métodos , Masculino , Mandíbula/diagnóstico por imagen , Radiografía Panorámica
4.
Clin Oral Implants Res ; 26(11): 1321-7, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25039481

RESUMEN

OBJECTIVES: The aim of this study was to test the hypothesis that recombinant human growth and differentiation factor-5 (rhGDF-5) induces an increased and homogenous distribution of new bone formation across the entire volume of sinus floor augmentation in 12 Goettingen Minipigs. MATERIAL AND METHODS: In a randomized split-mouth design, one maxillary sinus was augmented with the bone substitute ß-TCP, whereas a combination of ß-TCP and the osteoinductive growth factor rhGDF-5 was used on the contralateral side. To evaluate the influence of dose and time on the effectiveness of the factor, two different concentrations of rhGDF-5 (400 µg and 800 µg) and healing periods (4 and 12 weeks) were each analysed. RESULTS: After 4 weeks, a homogenous gradient of bone formation could be observed for all dosage groups, with decreasing bone density from the local bone towards the sinus membrane. Both test groups, however, achieved a higher total level of bone formation compared with the control group, which was only significant in the low-dose group (P = 0.0184). After 12 weeks, the influence of the growth factor significantly depends on the region (P = 0.023). In the low-dose group, the new bone formation did not differ significantly within the examined regions of the graft (P = 0.1118), suggesting a homogeneous bone formation over the entire augmentation. The gradient of the high-dose group was similar to the control group with a decrease of local bone development. CONCLUSIONS: rhGDF-5 delivered on a ß-TCP scaffold material leads to an increase in homogeneous new bone formation across the entire volume of the sinus floor augmentation.


Asunto(s)
Regeneración Ósea/efectos de los fármacos , Factor 5 de Diferenciación de Crecimiento/farmacología , Osteogénesis/efectos de los fármacos , Elevación del Piso del Seno Maxilar , Animales , Sustitutos de Huesos , Femenino , Modelos Animales , Elevación del Piso del Seno Maxilar/métodos , Porcinos , Porcinos Enanos , Factores de Tiempo , Cicatrización de Heridas
5.
Clin Exp Dent Res ; 8(6): 1440-1448, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35938927

RESUMEN

OBJECTIVES: To test the hypothesis that routine dental radiographs can be used to draw conclusions regarding the mandibular canal (MC) localization. MATERIAL AND METHODS: A total of 108 radiographs (36 orthopantomograms [OPTs], 36 lateral cephalograms [LCs], and 36 cone-beam computed tomograms [CBCTs]) of 36 patients were analyzed. Statistical analysis included all cephalometric parameters obtained by OPTs, LCs, and CBCTs. Potential influencing parameters were calculated using linear and logistic regression with a backward removal algorithm. For predictability of MC localization, parameters were correlated using Pearson's correlation. RESULTS: The MC ran along the lingual half (n = 24) twice as often as in the buccal half (n = 12) in the population studied. The position was always symmetrical contralaterally. No sex-specific influence was observed (p = .34). Lingual and buccal MC courses were statistically significantly correlated to increased and decreased jaw angles (LC/OPT), respectively (p = .003; r = -.48/p = .010; r = -.42). An increased jaw angle was significantly correlated with a more cranial MC position (p = .013; r = -.41); a deep and distal bite position was significantly correlated with a caudal and buccal MC position (p = .004; r = -.47/p = .001; r = .57). Moreover, an increase of 1 point in the Hasund score predicted an increased probability of a buccal MC position by 18.6%. The jaw angle analyzed in OPT and LC images were positively correlated (r = .89, p < .001). CONCLUSIONS: Routine dental radiographs provide informative guidance on the location of the MC in the vertical and transverse levels. This finding could be used in the initial consultation and treatment planning to consider more invasive diagnostic methods further down the line.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Mandíbula , Humanos , Mandíbula/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Canal Mandibular , Radiografía Panorámica , Planificación de Atención al Paciente
6.
Eur J Orthod ; 33(6): 628-35, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21262934

RESUMEN

The aim of the study was to establish whether juveniles with a Class II malocclusion change the neuromuscular control of mandibular movements during the course of orthodontic treatment with removable functional appliances (RFAs). Neuromuscular control can be indirectly evaluated by recording cyclic planar mandibular movements which were freely carried out by the patients (28 girls, 14 boys, aged 11.1 ± 1.1 years at the start of treatment) and measured with an ultrasonic device before, during, and after Class II functional appliance therapy, with either an activator or a bite jumping plate. The cyclic movements represented simultaneous rotations of the mandible around a maxillary and mandibular fixed axis (MFHA) and could be characterized by µ(α)-diagrams (µ = swing angle of MFHA, α = mouth opening angle) and path length (L) of the MFHA. The µ(α)-diagrams clearly divided into four parts: movement representing protrusion, mouth opening, and two parts of backward closing as known from Posselt diagrams. Parameters from the Posselt and µ(α)-diagrams were checked by one-factor analysis of variance on a 5 per cent significance level for group dependency. For one-third of the patients investigated, no significant changes were seen in any parameter pre- or post-therapy. However, patients showing an initially large mouth opening capacity or a very short condylar path changed their neuromuscular control to that of Class I subjects. Analysis of µ(α)-diagrams provides the possibility of assessing changes in the neuromuscular control of the mandible during Class II treatment.


Asunto(s)
Maloclusión Clase II de Angle/terapia , Mandíbula/fisiopatología , Aparatos Ortodóncicos Funcionales , Aparatos Ortodóncicos Removibles , Aparatos Activadores , Adolescente , Algoritmos , Niño , Femenino , Estudios de Seguimiento , Humanos , Estudios Longitudinales , Masculino , Maloclusión Clase II de Angle/fisiopatología , Cóndilo Mandibular/fisiopatología , Movimiento , Unión Neuromuscular/fisiología , Rango del Movimiento Articular/fisiología , Rotación , Ultrasonido/instrumentación
7.
Angle Orthod ; 80(2): 239-46, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19905847

RESUMEN

OBJECTIVE: To determine the forces and moments delivered to a maxillary central incisor during rotation by three different thermoplastic appliances with identical thickness. MATERIALS AND METHODS: Five identical appliances were manufactured from each of three materials (Ideal Clear 1.0 mm, Erkodur 1.0 mm, Biolon 1.0 mm). An upper central incisor fixed in a measuring device was rotated around its central axis in 0.5-degree steps to +/-2.5 degrees, +/-5 degrees, and +/-7.5 degrees (equivalent to an activation of +/-0.17 mm, +/-0.34 mm, and +/-0.51 mm of the incisor edge) in the clockwise and anticlockwise directions with the respective appliance fixed in place. For statistical analysis, the moments Tz (rotation) and forces Fz (intrusion) were tested. Means and standard deviations for Tz and median and 25% and 75% quantiles for Fz were calculated. An analysis of variance (ANOVA) was performed. RESULTS: The minimal moment was determined at a rotation of -0.17 mm (-7.3 Nmm, +/-0.8), and the maximal moment at a deflection of -0.51 mm (-71.8 Nmm. +/-2.5) was recorded. The minimal value for Fz was measured at an activation of -0.17 mm (0.0 N), and the highest intrusive forces were evaluated for a rotation of -0.51 mm (-5.8 N). The particular material sometimes had a significant (P < .05) influence on the forces delivered and the moments. CONCLUSIONS: During rotation with aligners, an intrusive force can also be observed. The direction of rotation, and the materials used all exert an influence on the force delivery properties of the appliance.


Asunto(s)
Análisis del Estrés Dental , Incisivo/fisiopatología , Aparatos Ortodóncicos Removibles , Técnicas de Movimiento Dental/instrumentación , Análisis de Varianza , Humanos , Maxilar , Diseño de Aparato Ortodóncico , Plásticos , Rotación
8.
Eur J Orthod ; 32(6): 607-13, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20462912

RESUMEN

The forces delivered by aligners during torquing have still not been investigated. The purpose of this study was to measure the forces delivered to an upper central incisor during torquing with three different materials of the same thickness, and to describe the biomechanical principles of torquing with aligners. Five identical appliances were manufactured from each of three materials, all with a thickness of 1.0 mm (Ideal Clear®, Erkodur®, and Biolon®). An upper central incisor, as part of the measuring device, was torqued in defined steps in the vestibular and palatal directions with the respective appliance in place. For statistical analysis, the resulting forces, Fx (forces acting in the palatal and facial directions) and Fz (intrusive force as a side-effect) at a displacement of ±0.15 and ±0.8 mm from the tooth at the gingival margin were calculated. The mean Fx forces for ±0.15 mm displacement ranged from -1.89 N [standard deviation (SD) 0.48] to 0.11 N (SD 0.1). The mean Fz forces were between -0.97 N (SD 0.57) and -0.07 N (SD 0.22). The highest intrusive forces were measured during palatal displacement of the measuring tooth. An influence of direction of displacement on the levels of force was observed, especially for Fz at the greater displacement of ±0.8 mm. In relation to the intended amount of root movement during torquing, aligners tend to 'lift up' and therefore no effective force couple can be established for further root control. The force delivery properties are also influenced by the material used and the shape of the tooth.


Asunto(s)
Análisis del Estrés Dental , Incisivo/patología , Aparatos Ortodóncicos Removibles , Técnicas de Movimiento Dental/instrumentación , Resinas Acrílicas , Fenómenos Biomecánicos , Humanos , Maxilar , Diseño de Aparato Ortodóncico , Estadísticas no Paramétricas , Torque
9.
J Craniofac Surg ; 20(6): 2061-6, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19881367

RESUMEN

Nonsyndromic orofacial clefts might affect family functioning and probably reduce the quality of life in school-age children and their parents. One hundred seventy consecutive children with orofacial clefts between 8 and 12 years and their families were asked to answer the Impact on Family Scale and KINDL. The results were compared with the quality of life in an age- and sex-matched group of unaffected schoolchildren. One hundred thirty-two families participated in this study. Family functioning was found superior in families with children with cleft lip than in families with children with cleft palate only or cleft lip and palate. Sex had no significant influence on family functioning. The quality of life in schoolchildren with orofacial clefts was found superior to the control group. Reductions were observed in children with cleft lip and palate in the dimensions "family" and "friends," indicating problems in the social field. Boys with orofacial clefts experienced a lower quality of life than girls. Children with cleft lip and palate and cleft palate only experienced a lower quality of life than children with cleft lip. Even years after successful cleft reconstruction, coping and mastering the diagnosis of orofacial cleft is a relevant concern for affected families. Several limitations of the quality of life in schoolchildren were identified, mostly affecting their social role.


Asunto(s)
Labio Leporino/psicología , Fisura del Paladar/psicología , Calidad de Vida , Adaptación Psicológica , Adulto , Estudios de Casos y Controles , Niño , Relaciones Familiares , Femenino , Humanos , Masculino , Padres/psicología , Autoimagen , Encuestas y Cuestionarios
10.
Am J Orthod Dentofacial Orthop ; 136(1): 12.e1-7; discussion 12-3, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19577136

RESUMEN

INTRODUCTION: The aim of the study was to quantify the forces delivered by thermoplastic appliances made of 2 materials with 2 thicknesses to a maxillary central incisor during tipping. METHODS: Two materials were tested, each in 2 thicknesses: Erkodur (Erkodent Erich Kopp GmbH, Pfalzgrafenweiler, Germany) 1.0 and 0.8 mm, and Biolon (Dreve Dentamid GmbH, Unna, Germany), 1.0 and 0.75 mm. For each material, 5 appliances were produced. To measure the forces applied, an isolated measuring tooth, part of a standardized resin model, was deflected in 0.05 degrees steps from 0 degrees to 0.42 degrees in the vestibular and palatine directions, after placing the respective appliance on the model. For statistical analysis, the force components Fx/tipping and Fz/intrusion at a displacement of +/- 0.151 mm from the incisor edge were selected. Means and standard deviations were calculated. The Wilcoxon 2-sample test for group pairings was used. RESULTS: The norms for the mean Fx forces ranged from 1.62 (SD, 0.41) to 5.35 N (SD, 0.63). The mean Fz forces were between 0.07 (SD, 0.13) and -2.47 N (SD, 0.34). The highest intrusive forces were measured during vestibular displacement of the measuring tooth. The forces delivered by the thick appliances were overall significantly higher (P <0.0001) than those of the thin materials. The forces delivered by the Biolon appliances were generally significantly higher (P <0.0001) than those for the Erkodur materials. CONCLUSIONS: The forces applied were mostly too high when compared with those stated in the literature as ideal. In addition to thickness, the thermoforming process influences the magnitude of the force delivered by a thermoformed appliance.


Asunto(s)
Materiales Dentales/química , Incisivo/fisiopatología , Diseño de Aparato Ortodóncico , Plásticos/química , Técnicas de Movimiento Dental/instrumentación , Humanos , Ensayo de Materiales , Maxilar , Movimiento , Diseño de Aparato Ortodóncico/instrumentación , Diseño de Aparato Ortodóncico/métodos , Polietilenos/química , Polivinilos/química , Estrés Mecánico , Propiedades de Superficie , Temperatura , Torque
11.
Eur J Orthod ; 31(6): 625-31, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19525441

RESUMEN

The force properties of thermoformed appliances have not been systematically investigated. Therefore, the aim of the present study was to quantify the forces delivered by thermoplastic appliances manufactured from three different materials, with the same thickness, on a central upper incisor, during tipping. Five identical appliances were manufactured from three different materials all with a thickness of 1.0 mm (Ideal Clear, Erkodur, and Biolon). For measuring the forces, an isolated measuring tooth, as part of a standardized resin model incorporated in a newly developed measuring device, was tipped in nine 2.7 arc minute (0.04629 degree) steps, from 0 to 0.416 degrees in the vestibular and palatal directions around a rotational axis through the virtual apex, after positioning an appliance on the model. For statistical analysis, the force components Fx/tipping and Fz/intrusion at a displacement of +/-0.151 mm from the incisor edge were determined. Means and standard deviations (SDs) were calculated. The Kruskal-Wallis test for overall effects and the Wilcoxon two-sample test for individual group pairings were used (P < 0.05 significance level). The mean Fx forces ranged from -2.82 N (SD 0.62) to 5.42 N (SD 0.56). The mean Fz forces were between -0.14 N (SD 0.52) and -2.3 N (SD 0.43). The highest intrusive forces were measured during vestibular displacement of the measuring tooth. The forces delivered by the Biolon appliance were found to be much greater (P < 0.01) than those of the other materials. The forces delivered by the materials investigated were mostly higher than those stated in the literature.


Asunto(s)
Análisis del Estrés Dental , Incisivo/fisiopatología , Diseño de Aparato Ortodóncico , Aparatos Ortodóncicos Removibles , Técnicas de Movimiento Dental , Análisis del Estrés Dental/instrumentación , Humanos , Maxilar , Modelos Dentales , Aparatos Ortodóncicos Removibles/efectos adversos , Plásticos , Avulsión de Diente/etiología , Técnicas de Movimiento Dental/instrumentación , Dimensión Vertical
12.
Eur J Orthod ; 30(5): 433-6, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18687989

RESUMEN

The aim of this study was to evaluate the time requirement of a newly developed device made of neodymium-iron-boron (NdFeB) magnets for positioning a multi-stranded, canine-to-canine retainer during bonding compared with dental floss and a transfer tray. Forty-five patients aged between 12 and 33 years (26 male, 19 female) previously treated with fixed appliances were enrolled in the study. The patients were randomly allocated to three groups (15 per group). For each group a mandibular canine-to-canine retainer of 0.018 inch Dentaflex multi-stranded wire (Dentaurum) was prefabricated for each patient on a cast. The bonding procedure was identical, except for the method of positioning the wire during adhesive fixation: group A dental floss, group B a small prefabricated transfer tray of dental resin and group C the NdFeB magnet device. For each group, the time required for the complete bonding process was measured. Kruskal-Wallis and Wilcoxon-Mann-Whitney tests were used for group and pairwise comparisons, respectively. The three methods required statistically significant different times (P < 0.001). The Wilcoxon-Mann-Whitney test revealed that wire positioning with the magnet device was significantly faster [4.98 minutes; standard deviation (SD) 0.68 minutes] than with dental floss (7.65 minutes, SD 1.14 minutes; P = 0.0001) or with transfer tray (5.75 minutes, SD 0.57 minutes; P = 0.001). The NdFeB magnet device is a timesaving appliance for positioning a multi-stranded, canine-to-canine retainer during bonding when compared with dental floss and an individually prefabricated transfer tray.


Asunto(s)
Aleaciones Dentales , Recubrimiento Dental Adhesivo/instrumentación , Magnetismo/instrumentación , Retenedores Ortodóncicos , Alambres para Ortodoncia , Adolescente , Adulto , Boro , Niño , Femenino , Humanos , Hierro , Masculino , Neodimio , Proyectos Piloto , Estadísticas no Paramétricas , Factores de Tiempo , Adulto Joven
13.
Ann Anat ; 189(4): 339-41, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17695988

RESUMEN

Examinations of the curvature morphology of the temporomandibular joints (TMJs) in macerated human skulls yielded that in initial protrusive cranial border motion, parts of the condylar articulating surfaces are only functional under force transmission. These areas were found on the lateral-central side of the condyle. In contrast to the Cercopithecus mona, a monkey species, the human TMJ apparently possesses a distinctly higher spatial performance range.


Asunto(s)
Articulación Temporomandibular/anatomía & histología , Adulto , Humanos , Cóndilo Mandibular/anatomía & histología , Cóndilo Mandibular/fisiología , Cráneo/anatomía & histología , Cráneo/fisiología , Articulación Temporomandibular/fisiología
14.
Ann Anat ; 189(4): 390-2, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17695999

RESUMEN

The primary aim of the study was to reveal whether the free opening movement of the mandible can be determined by only 2 rotational axes as suggested in recent literature. For this purpose, the free opening movement of the mandible was registered in 20 asymptomatic patients using an ultrasonic measuring system. Subsequently, the locations of the instantaneous centers of rotation (ICR) were determined directly from the raw data. In a second approach, the same data were used to construct a mandibular and maxillar rotational axis according to the dimeric link chain (DLC) concept. On the basis of the angular velocities around these 2 axes, the positions of the ICR were calculated in the sagittal-vertical plane. Calculating the ICR by the DLC method provides similar results to that of the conventional approaches. It can be concluded that the DLC method is a valid approach and that considering the planar mandibular movement as a movement with 2 degrees of freedom is justified.


Asunto(s)
Mandíbula/anatomía & histología , Mandíbula/fisiología , Humanos , Modelos Biológicos , Movimiento , Rotación
15.
Ann Anat ; 189(4): 393-6, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17696000

RESUMEN

For the physiological intact stomatognathic system, the three main functional states (occlusat articular functions, free mandibular movements, and ideal bolus function) were biomechanically discussed concerning the structure of movement, rolling-gliding characteristics, and force transfer in the temporomandibular joint (TMJ). In all three cases, rolling is not possible in the TMJ since the instantaneous rotational axis is positioned outside of the joint-rolling is not necessary because the TMJ is not loaded by appreciable forces. In the aged stomatognathic system with a lost discus and considerable Loads in the TMJ, however, the attrition of the joint is eased by rolling movement at the articulating surfaces. The destruction of the discus can be seen as a physiological adaptation which brings back the joint to an original odontogen condition.


Asunto(s)
Mandíbula/fisiología , Articulación Temporomandibular/fisiología , Anciano , Envejecimiento , Fenómenos Biomecánicos , Humanos , Actividad Motora , Movimiento , Cráneo/fisiología , Articulación Temporomandibular/crecimiento & desarrollo
16.
Ann Anat ; 189(4): 404-6, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17696002

RESUMEN

The subject of this study was to analyse how functional parameters of stomatognathic systems are influenced by growth. For this purpose, two cephalometric radiographs of 65 patients with class-II-relation treated with functional appliances were superimposed on the occlusal plane. The two patient groups consisted of 32 open bite and 33 deep bite cases. The direction of the condylar growth significantly differed for both cases. Nevertheless the hypothesis could be confirmed that the original functional structure was hardly affected by growth.


Asunto(s)
Oclusión Dental , Maloclusión Clase I de Angle/fisiopatología , Mandíbula/fisiología , Envejecimiento/fisiología , Fenómenos Biomecánicos , Fuerza de la Mordida , Humanos , Mandíbula/crecimiento & desarrollo , Cóndilo Mandibular/anatomía & histología , Cóndilo Mandibular/fisiopatología
17.
Prog Orthod ; 18(1): 28, 2017 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-28845511

RESUMEN

BACKGROUND: The present study aimed to evaluate the force delivery of removable thermoplastic appliances (RTAs), modified by different sized incisal cuts, during tipping of a maxillary central incisor in palatal and vestibular direction. METHODS: Forty-five RTAs from three different materials (Biolon®, Erkodur®, Ideal Clear®) of the same thickness (1 mm) were used. Analysis was performed on a separated maxillary central incisor which was part of a resin model with a complete dentition. In 15 RTAs, of different material, a cut was inserted at the incisal edge of tooth 11. In 15 other appliances, the cut was extended to teeth 12 and 21. Fifteen aligners remained uncut. The experimental tooth was tipped starting from the zero position in 0.05° steps to a maximal deflection of ± 0.42° of the incisal edge in vestibular and palatal direction, after positioning the RTA onto the model. RESULTS: The horizontal (Fx) and the vertical (Fz) force components were decreased by approximately half with increasing cut size. Fz values changed during palatal tipping from a weak intrusive force, for aligners without cut, to an extrusive force with increasing cut size. Compared to both other materials used (Erkodur® and Ideal Clear®), the Biolon® aligners showed significantly higher Fx and Fz values (p < 0.0001, respectively). CONCLUSIONS: RTAs modified by different sized incisal cuts show altered biomechanical properties and an inversion of the vertical force component, during tipping of a maxillary central incisor.


Asunto(s)
Diseño de Dentadura , Aparatos Ortodóncicos Removibles , Fenómenos Biomecánicos , Incisivo
18.
Artículo en Inglés | MEDLINE | ID: mdl-27720655

RESUMEN

OBJECTIVE: We compared the intraindividual effects of increasing zoledronic acid (ZA) concentrations on osteoblast-like cells with different embryologic origins. STUDY DESIGN: Cultured osteoblast-like cells from mandible and iliac crest bone samples of domestic pigs were exposed to increasing concentrations of ZA (0, 10-8, 10-6, and 10-4 M). Proliferation was assessed by cell counting. Receptor activator of nuclear factor kB ligand and osteoprotegerin (OPG) messenger RNA expression were assessed at 0, 1, 4, 7, and 10 days. RESULTS: The OPG expression level was higher in the iliac crest than in the mandible. Neither ZA concentration nor the cells' origin affected the expression of receptor activator of nuclear factor kB ligand. At 10-6 M, OPG expression from both locations reached the same level after 7 days of cultivation, as OPG expression increased to a greater extent in the mandible in comparison to the iliac crest. CONCLUSION: Cultured mandibular osteoblast-like cells reacted more sensitively to high ZA concentrations than did osteoblast-like cells from the iliac crest.


Asunto(s)
Difosfonatos/farmacología , Imidazoles/farmacología , Osteoblastos/efectos de los fármacos , Osteoblastos/metabolismo , Animales , Células Cultivadas , Femenino , Ilion/citología , Mandíbula/citología , Osteoprotegerina/metabolismo , Proyectos Piloto , ARN Mensajero/metabolismo , Receptor Activador del Factor Nuclear kappa-B/metabolismo , Sus scrofa , Porcinos , Ácido Zoledrónico
19.
Oral Maxillofac Surg ; 19(3): 301-7, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25908245

RESUMEN

PURPOSE: This clinical trial aimed to test the hypothesis that piezosurgery causes reduced nerval irritations and, thus, reduced somatosensory impairment when used in orthognathic surgery of the mandible. METHODS: To this end, 37 consecutive patients with Angle Class II and III malocclusion were treated using bilateral sagittal split osteotomies (BSSO) of the mandible. In a split mouth design, randomized one side of the mandible was operated using a conventional saw, while a piezosurgery device was used on the contralateral side. In order to test the individual qualities of somatosensory function, quantitative sensory testings (QSTs) were performed 1 month, 6 months and 1 year after surgery. RESULTS: A comparison of the data using a two-way analysis of variance (ANOVA) revealed a significant reduction in postoperative impairment in warm detection threshold (WDT) (P = 0.046), a decreased dynamic mechanical allodynia (ALL) (P = 0.002) and a decreased vibration detection threshold (VDT) (P = 0.030) on the piezosurgery side of the mandible as opposed to the conventionally operated control side. In the remaining QSTs, minor deviations from the preoperative baseline conditions and a more rapid regression could be observed. CONCLUSIONS: Piezosurgery caused reduced somatosensory impairment and a faster recovery of somatosensory functions in the present investigation.


Asunto(s)
Hiperalgesia/diagnóstico , Hiperalgesia/fisiopatología , Maloclusión de Angle Clase III/cirugía , Maloclusión Clase II de Angle/cirugía , Mandíbula/inervación , Mandíbula/cirugía , Cirugía Ortognática/métodos , Osteotomía Sagital de Rama Mandibular/métodos , Piezocirugía/métodos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/fisiopatología , Umbral Sensorial/fisiología , Sensación Térmica/fisiología , Vibración , Adolescente , Adulto , Femenino , Humanos , Masculino , Recuperación de la Función , Adulto Joven
20.
Angle Orthod ; 82(1): 145-50, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21812573

RESUMEN

OBJECTIVE: To conduct a pilot study to investigate the potentiality to determine the midpalatal sutural width radiographically with a flat-panel volume computed tomography (fpVCT) in a porcine model. MATERIALS AND METHODS: Bone samples from the midpalatal suture of five young (16 weeks) and five old (200 weeks) sus scrofa domestica were gathered. The midpalatal suture width was measured via fpVCT and compared to respective histological preparations. Results with P < .05 were considered significant. RESULTS: The data obtained by fpVCT and by histomorphometric analysis reveal a highly significant age dependency of the measured suture width (both P < .0001), with lower suture width values in older subjects compared to the younger group. The averaged suture widths measured in the fpVCT images shows a distinctively higher mean compared to the histomorphometric data with high statistical significance (P < .0001). The evaluated difference between both methods was almost constant. CONCLUSION: fpVCT is a powerful tool for determining midpalatal sutural width.


Asunto(s)
Cefalometría/instrumentación , Tomografía Computarizada de Haz Cónico , Suturas Craneales/anatomía & histología , Paladar Duro/anatomía & histología , Factores de Edad , Animales , Suturas Craneales/diagnóstico por imagen , Suturas Craneales/crecimiento & desarrollo , Desarrollo Maxilofacial , Tamaño de los Órganos , Paladar Duro/diagnóstico por imagen , Paladar Duro/crecimiento & desarrollo , Sus scrofa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA