Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Occup Environ Hyg ; 19(2): 102-110, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34895086

RESUMEN

COVID-19 has created shortages of personal protective equipment. In resource-constrained situations, limited cycles of disinfection and extended use of gloves is recommended by the U.S. Centers for Disease Control and Prevention to conserve supplies. However, these guidelines are based on limited evidence. In this study, serial cycles of hand hygiene were performed on gloved hands using an ethanol-based hand rub (six and 10 cycles), 0.1% sodium hypochlorite (bleach) solution (10 cycles), or soap and water (10 cycles) on latex and nitrile medical exam gloves from the United States and India. A modified water-leak test evaluated glove integrity after repeated applications of these disinfecting agents. When aggregated, dilute bleach demonstrated the lowest difference between treatment and control arms: -2.5 percentage points (95% CI: -5.3 to 0.3) for nitrile, 0.6 percentage points (95% CI: -2.6 to 3.8) for non-powdered latex. For U.S.-purchased gloves tested with six and 10 applications of ethanol-based hand rub, the mean difference in failure risk between treatment and control gloves was within the prespecified non-inferiority margin of five percentage points or less, though some findings were inconclusive since outside the margin. The aggregated difference in failure risk between treatment and control was 3.5 percentage points (0.6 to 6.4) for soap and water, and 2.3 percentage points (-0.5 to 5.0) and 5.0 percentage points (1.8 to 8.2) for 10 and 6 applications of ethanol-based hand rub, respectively. Most leaks occurred in the interdigital webs (35%) and on the fingers (34%). This indicates that some combinations of glove types and disinfection methods may allow for extended use. Ten applications of dilute bleach solution had the least impact on glove integrity. However, the majority of glove and exposure combinations were inconclusive. Additional testing of specific glove and disinfectant combinations may inform future strategies to guide extended use during glove shortages. Additional considerations, not evaluated here, include duration of use, disinfectant chemical permeation, and the effects of hand temperature, movement, and manipulation of instruments on glove integrity.


Asunto(s)
COVID-19 , Desinfectantes , Desinfección , Falla de Equipo , Guantes Protectores , Guantes Quirúrgicos , Humanos , SARS-CoV-2
2.
J Occup Environ Hyg ; 19(2): 111-121, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34895087

RESUMEN

Many healthcare professionals have been forced, under acute shortages, to extend medical exam gloves beyond their intended single use. Despite limited available literature, the CDC proposed a set of guidelines for repeated exam gloves use, indicating a maximum number of treatments for three widely available disinfectants. This study examines how these treatments affect the mechanical properties of latex and nitrile gloves. Furthermore, an acceptability threshold is proposed for changes in tensile property, specifically elastic modulus, as an indication of degradation. This proposed criterion was also applied to similar studies available in the literature to determine applicability and aid in recommendation development. Three different latex glove brands and three nitrile brands were exposed to repeated treatments of an alcohol-based hand rub, diluted bleach, or soap and water. Tensile tests of samples cut from untreated and treated gloves were performed to assess the change in elastic modulus induced by each treatment. The findings suggest that latex gloves performed well within the CDC recommended guidelines of six repeated treatments for an ethanol-based hand rub and 10 repeated treatments of either dilute bleach or soap and water. Nitrile exam gloves, on the other hand, showed significant changes in elastic modulus, with more inconclusive results among brands. This was especially true for treatment with dilute bleach and soap and water. Further research is needed to investigate the effects of disinfection products on the mechanical integrity of nitrile exam gloves. The results support the use of five repeated treatments of ethanol-based hand rub for nitrile exam gloves, a lower threshold than currently recommended by the CDC. This research also supports that the CDC recommendation of 10 repeated treatment with soap and water is appropriate for latex exam gloves, but not for nitrile exam gloves. Occupational safety and health professionals involved in the selection of disposable exam gloves for infection control should consider the compatibility of the glove polymer type with available disinfectants, especially if extended use with repeated disinfection becomes necessary.


Asunto(s)
Desinfectantes , Desinfección , 2-Propanol , Guantes Protectores , Látex
3.
J Endourol ; 36(10): 1355-1361, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35726396

RESUMEN

Introduction: Surgical skill evaluation while performing minimally invasive surgeries is a highly complex task. It is important to objectively assess an individual's technical skills throughout surgical training to monitor progress and to intervene when skills are not commensurate with the year of training. The miniaturization of wireless wearable platforms integrated with sensor technology has made it possible to noninvasively assess muscle activations and movement variability during performance of minimally invasive surgical tasks. Our objective was to use electromyography (EMG) to deconstruct the motions of a surgeon during robotic suturing (RS) and distinguish quantifiable movements that characterize the skill of an experienced expert urologic surgeon from trainees. Methods: Three skill groups of participants, novice (n = 11), intermediate (n = 12), and expert (n = 3), were enrolled in the study. A total of 12 wireless wearable sensors consisting of surface EMGs and accelerometers were placed along upper extremity muscles to assess muscle activations and movement variability, respectively. Participants then performed a RS task. Results: EMG-based parameters, total time, dominant frequency, and cumulative muscular workload, were significantly different across the three skill groups. We also found nonlinear movement variability parameters such as correlation dimension, Lyapunov exponent trended differently across the three skill groups. Conclusions: These findings suggest that economy of motion variables and nonlinear movement variabilities are affected by surgical experience level. Wearable sensor signal analysis could make it possible to objectively evaluate surgical skill level periodically throughout the residency training experience. Clinical Trial Registration Number: HS# 2018-4407.


Asunto(s)
Internado y Residencia , Robótica , Competencia Clínica , Electromiografía , Humanos , Urólogos
4.
Ann Otol Rhinol Laryngol ; 128(4): 293-299, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30607984

RESUMEN

OBJECTIVE:: Idiopathic subglottic stenosis (iSGS) is a rare disease with few local resources for individuals to use. With the explosive growth of online social networking, platforms such as Facebook possess compelling potential to facilitate user-driven sharing of health information and peer support. This study was performed to better understand the content shared in a busy online community for individuals with iSGS. METHODS:: The largest online community (OC) for individuals with iSGS, Living With Idiopathic Subglottic Stenosis (LwiSGS), was examined. A thematic content analysis of the communications shared in February of 2018 was performed. A conventional qualitative analysis model was employed to analyze aggregated data. The data were then codified. RESULTS:: Analysis demonstrated that communications primarily encompassed three major thematic elements: (1) information sharing; (2) emotional support, expression, and experience sharing; and (3) community building. Positively toned posts grossly overshadowed negatively toned posts by almost a factor of 3. A significant portion of group members requested information from their peers, suggesting a high level of trust toward the resources provided in this group, even those involving a surgical procedure or medication. CONCLUSION:: LwiSGS is a forum for patients with a rare chronic condition to share informational resources, personal experiences, and emotional support, as well as a community with their peers. These data suggest that LwiSGS could be a powerful resource for individuals with iSGS to share information, personal experiences, or emotional support.


Asunto(s)
Acceso a la Información , Manejo de la Enfermedad , Difusión de la Información/métodos , Internet , Laringoestenosis , Grupos de Autoayuda , Emociones , Femenino , Salud Global/tendencias , Humanos , Laringoestenosis/epidemiología , Laringoestenosis/psicología , Masculino , Sistemas de Apoyo Psicosocial , Grupos de Autoayuda/organización & administración , Grupos de Autoayuda/tendencias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA