Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Vascular ; 29(6): 927-937, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33459205

RESUMEN

OBJECTIVE: This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. METHODS: After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into "not opacified", "<50% stenosis", " 50 ̶70% stenosis", ">70% stenosis", and "occluded" for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. RESULTS: Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8-32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively (p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus (p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) (p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients (p = 0.319), respectively. CONCLUSION: Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste/administración & dosificación , Yohexol/administración & dosificación , Extremidad Inferior/irrigación sanguínea , Enfermedad Arterial Periférica/diagnóstico por imagen , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Flujo Sanguíneo Regional , Índice de Severidad de la Enfermedad
2.
Radiographics ; 39(3): 729-743, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31059394

RESUMEN

Photon-counting detector (PCD) CT is an emerging technology that has shown tremendous progress in the last decade. Various types of PCD CT systems have been developed to investigate the benefits of this technology, which include reduced electronic noise, increased contrast-to-noise ratio with iodinated contrast material and radiation dose efficiency, reduced beam-hardening and metal artifacts, extremely high spatial resolution (33 line pairs per centimeter), simultaneous multienergy data acquisition, and the ability to image with and differentiate among multiple CT contrast agents. PCD technology is described and compared with conventional CT detector technology. With the use of a whole-body research PCD CT system as an example, PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed. The potential clinical applications, diagnostic benefits, and challenges associated with this technology are then discussed, and examples with phantom, animal, and patient studies are provided. ©RSNA, 2019.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X/métodos , Animales , Medios de Contraste , Diseño de Equipo , Humanos , Compuestos de Yodo , Dosis de Radiación , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/tendencias
3.
J Comput Assist Tomogr ; 43(4): 612-618, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31268876

RESUMEN

OBJECTIVE: The aim of this study was to determine if computed tomography (CT) angiography using an individualized transition delay (CTA-ID) would facilitate reductions in injection rate and iodine dose. METHODS: The CTA-ID was performed in 20 patients with routine injection rate and iodine dose; 20 patients with injection rate lowered by 1 mL/s; and 40 patients with injection rate lowered by 1 mL/s with 29% less iodine. Routine CTAs in the same or size-matched patients served as controls. Diagnostic image quality and intra-arterial CT numbers were assessed. RESULTS: The median transition delay between aortic threshold and CTA-ID image acquisition was significantly longer than with conventional bolus tracking (mean increase, 13.3 seconds; P < 0.0001), with image quality being the same or better. Intra-arterial CT numbers were 200 Hounsfield units or greater for 80 of 80 CTA-ID, but not for 6 of 49 (12%) internal control or for 11 of 80 (14%) size-matched control patients. CONCLUSION: The CTA-ID bolus-tracking software alters transition delays to permit diagnostic CTA examinations despite slower injection rate and less iodine.


Asunto(s)
Abdomen , Aorta/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Medios de Contraste , Yodo , Abdomen/irrigación sanguínea , Abdomen/diagnóstico por imagen , Anciano , Angiografía por Tomografía Computarizada/métodos , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Medios de Contraste/administración & dosificación , Medios de Contraste/uso terapéutico , Humanos , Yodo/administración & dosificación , Yodo/uso terapéutico , Masculino , Radiografía Abdominal , Estudios Retrospectivos , Factores de Tiempo
4.
Radiology ; 289(2): 436-442, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30084728

RESUMEN

Purpose To compare a research photon-counting-detector (PCD) CT scanner to a dual-source, dual-energy CT scanner for the detection and characterization of renal stones in human participants with known stones. Materials and Methods Thirty study participants (median age, 61 years; 10 women) underwent a clinical renal stone characterization scan by using dual-energy CT and a subsequent research PCD CT scan by using the same radiation dose (as represented by volumetric CT dose index). Two radiologists were tasked with detection of stones, which were later characterized as uric acid or non-uric acid by using a commercial dual-energy CT analysis package. Stone size and contrast-to-noise ratio were additionally calculated. McNemar odds ratios and Cohen k were calculated separately for all stones and small stones (≤3 mm). Results One-hundred sixty renal stones (91 stones that were ≤ 3 mm in axial length) were visually detected. Compared with 1-mm-thick routine images from dual-energy CT, the odds of detecting a stone at PCD CT were 1.29 (95% confidence interval: 0.48, 3.45) for all stones. Stone segmentation and characterization were successful at PCD CT in 70.0% (112 of 160) of stones versus 54.4% (87 of 160) at dual-energy CT, and was superior for stones 3 mm or smaller at PCD CT (45 vs 25 stones, respectively; P = .002). Stone characterization agreement between scanners for stones of all sizes was substantial (k = 0.65). Conclusion Photon-counting-detector CT is similar to dual-energy CT for helping to detect renal stones and is better able to help characterize small renal stones. © RSNA, 2018.


Asunto(s)
Cálculos Renales/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Riñón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Fotones , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/instrumentación
5.
J Appl Clin Med Phys ; 19(4): 252-260, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29749048

RESUMEN

OBJECTIVES: Both projection and dual-energy (DE)-based methods have been used for metal artifact reduction (MAR) in CT. The two methods can also be combined. The purpose of this work was to evaluate these three MAR methods using phantom experiments for five types of metal implants. MATERIALS AND METHODS: Five phantoms representing spine, dental, hip, shoulder, and knee were constructed with metal implants. These phantoms were scanned using both single-energy (SE) and DE protocols with matched radiation output. The SE data were processed using a projection-based MAR (iMAR, Siemens) algorithm, while the DE data were processed to generate virtual monochromatic images at high keV (Mono+, Siemens). In addition, the DE images after iMAR were used to generate Mono+ images (DE iMAR Mono+). Artifacts were quantitatively evaluated using CT numbers at different regions of interest. Iodine contrast-to-noise ratio (CNR) was evaluated in the spine phantom. Three musculoskeletal radiologists and two neuro-radiologists independently ranked the artifact reduction. RESULTS: The DE Mono+ at high keV resulted in reduced artifacts but also lower iodine CNR. The iMAR method alone caused missing tissue artifacts in dental phantom. DE iMAR Mono+ caused wrong CT numbers in close proximity to the metal prostheses in knee and hip phantoms. All musculoskeletal radiologists ranked SE iMAR > DE iMAR Mono+ > DE Mono+ for knee and hip, while DE iMAR Mono+ > SE iMAR > DE Mono+ for shoulder. Both neuro-radiologists ranked DE iMAR Mono+ > DE Mono+ > SE iMAR for spine and DE Mono+ > DE iMAR Mono+ > SE iMAR for dental. CONCLUSIONS: The SE iMAR was the best choice for the hip and knee prostheses, while DE Mono+ at high keV was best for dental implants and DE iMAR Mono+ was best for spine and shoulder prostheses. Artifacts were also introduced by MAR algorithms.


Asunto(s)
Artefactos , Algoritmos , Humanos , Metales , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
6.
J Comput Assist Tomogr ; 40(4): 663-70, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27096399

RESUMEN

PURPOSE: A research photon-counting computed tomography (CT) system that consists of an energy-integrating detector (EID) and a photon-counting detector (PCD) was installed in our laboratory. The scanning fields of view of the EID and PCD at the isocenter are 500 and 275 mm, respectively. When objects are larger than the PCD scanning field of view, a data-completion scan (DCS) using the EID subsystem is needed to avoid truncation artifacts in PCD images. The goals of this work were to (1) find the impact of a DCS on noise of PCD images and (2) determine the lowest possible dose for a DCS such that truncation artifacts are negligible in PCD images. METHODS: First, 2 semianthropomorphic abdomen phantoms were scanned on the PCD subsystem. For each PCD scan, we acquired 1 DCS with the maximum effective mAs and 5 with lower effective mAs values. The PCD image reconstructed using the maximum effective mAs was considered as the reference image, and those using the lower effective mAs as the test images. The PCD image reconstructed without a DCS was considered the baseline image. Each PCD image was assessed in terms of noise and CT number uniformity; the results were compared among the baseline, test, and reference images. Finally, the impact of a DCS on PCD image quality was qualitatively assessed for other body regions using an anthropomorphic torso phantom. RESULTS: The DCS had a negligible impact on the noise magnitude in the PCD images. The PCD images with the minimum available dose (CTDIvol < 2 mGy) showed greatly enhanced CT number uniformity compared with the baseline images without noticeable truncation artifacts. Further increasing the effective mAs of a DCS did not yield noticeable improvement in CT number uniformity. CONCLUSIONS: A DCS using the minimum available dose had negligible effect on image noise and was sufficient to maintain satisfactory CT number uniformity for the PCD scans.


Asunto(s)
Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Protección Radiológica/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Imagen de Cuerpo Entero/instrumentación , Recuento Corporal Total/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Fantasmas de Imagen , Fotones , Dosis de Radiación , Protección Radiológica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Imagen de Cuerpo Entero/métodos , Recuento Corporal Total/métodos
7.
AJR Am J Roentgenol ; 205(6): 1203-7, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26587926

RESUMEN

OBJECTIVE: The purpose of this phantom study was to determine the utility of a third-generation dual-source CT scanner with increased dual-energy spectral separation in differentiating urinary stone composition. MATERIALS AND METHODS: Eighty-seven urinary stones from humans were scanned in 35-, 40-, 45-, and 50-cm wide anthropomorphic phantoms with a third-generation dual-source scanner (system A) with a high-energy beam of 150 kV plus 0.6-mm tin filtration (Sn). The low-energy data were acquired at 70, 80, 90, and 100 kV. A second-generation dual-source scanner (system B) was used to acquire data at 140 kV plus 0.4-mm Sn for the high-energy and 80 or 100 kV for the low-energy images. Volume CT dose index was matched for a given phantom size. CT number ratios were calculated and used to differentiate uric acid from non-uric acid stones and oxalate from apatite stones in an ROC analysis. RESULTS: The area under the curve (AUC) of the ROC curve for uric acid versus non-uric acid stones increased for large phantoms. For example, for imaging of the 45-cm wide phantom with system A at the 100- and 150-kV Sn low- and high-energy combination, the AUC was 0.99, whereas for system B at the 100- and 140-kV Sn combination, the AUC was 0.86. At each phantom size and for all energy combinations, the AUC values for oxalate versus apatite stones were higher for system A than they were for any energy combination for system B. CONCLUSION: Compared with use of second-generation dual-source CT, use of third-generation dual-source CT at the energy combination of 100 and 150 kV Sn improved classification of urinary stones across a wide range of phantom sizes and increased the ability to differentiate oxalate from apatite stones.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Cálculos Urinarios/química , Cálculos Urinarios/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador
8.
J Magn Reson Imaging ; 39(3): 735-41, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24123760

RESUMEN

PURPOSE: To evaluate the use of a modular MRI conditional respiratory monitoring and gating solution, designed to facilitate proper monitoring of subjects' vital signals and their respiratory efforts, during free-breathing and breathheld 19F, oxygen-enhanced, and Fourier-decomposition MRI-based acquisitions. MATERIALS AND METHODS: All Imaging was performed on a Siemens TIM Trio 3 Tesla MRI scanner, following Institutional Review Board approval. Gas delivery is accomplished through the use of an MR compatible pneumotachometer, in conjunction with two three-way pneumatically controlled Hans Rudolph Valves. The pneumatic valves are connected to Douglas bags used as the gas source. A mouthpiece (+nose clip) or an oro-nasal Hans Rudolph disposable mask is connected following the pneumatic valve to minimize dead-space and provide an airtight seal. Continuous monitoring/sampling of inspiratory and expiratory oxygen and carbon dioxide levels at the mouthpiece/mask is achieved through the use of an Oxigraf gas analyzer. RESULTS: Forty-four imaging sessions were successfully monitored, during Fourier-decomposition (n=3), fluorine-enhanced (n=29), oxygen-enhanced, and ultra short echo (n=12) acquisitions. The collected waveforms, facilitated proper monitoring and coaching of the subjects. CONCLUSION: We demonstrate an inexpensive, off-the-shelf solution for monitoring these signals, facilitating assessments of lung function. Monitoring of respiratory efforts and exhaled gas concentrations assists in understanding the heterogeneity of lung function visualized by gas imaging.


Asunto(s)
Asma/diagnóstico , Fibrosis Quística/diagnóstico , Imagen por Resonancia Magnética , Monitoreo Fisiológico/métodos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Pruebas de Función Respiratoria/métodos , Adolescente , Adulto , Anciano , Estudios de Cohortes , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intercambio Gaseoso Pulmonar , Valores de Referencia , Pruebas de Función Respiratoria/instrumentación , Mecánica Respiratoria , Fenómenos Fisiológicos Respiratorios , Adulto Joven
9.
Radiology ; 267(3): 747-56, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23192773

RESUMEN

PURPOSE: To compare measurements of regional pulmonary perfused blood volume (PBV) and pulmonary blood flow (PBF) obtained with computed tomography (CT) in two pig models. MATERIALS AND METHODS: The institutional animal care and use committee approved all animal studies. CT-derived PBF and PBV were determined in four anesthetized, mechanically ventilated, supine swine by using two methods for creating pulmonary parenchymal perfusion heterogeneity. Two animals were examined after sequentially moving a pulmonary arterial balloon catheter from a distal to a central location, and two others were examined over a range of static airway pressures, which varied the extents of regional PBF. Lung sections were divided into blocks and Pearson correlation coefficients calculated to compare matching regions between the two methods. RESULTS: CT-derived PBF, CT-derived PBV, and their associated coefficients of variation (CV) were closely correlated on a region-by-region basis in both the balloon occlusion (Pearson R = 0.91 and 0.73 for animals 1 and 2, respectively; Pearson R = 0.98 and 0.87 for comparison of normalized mean and CV for animals 1 and 2, respectively) and lung inflation studies (Pearson R = 0.94 and 0.74 for animals 3 and 4, respectively; Pearson R = 0.94 and 0.69 for normalized mean and CV for animals 3 and 4, respectively). When accounting for region-based effects, correlations remained highly significant at the P < .001 level. CONCLUSION: CT-derived PBV heterogeneity is a suitable surrogate for CT-derived PBF heterogeneity.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Volumen Sanguíneo/fisiología , Pulmón/irrigación sanguínea , Pulmón/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Animales , Medios de Contraste/administración & dosificación , Yopamidol/administración & dosificación , Modelos Animales , Porcinos
10.
Radiology ; 268(2): 572-80, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23592768

RESUMEN

PURPOSE: To evaluate the effects of lung volume differences on apparent diffusion coefficient (ADC) measurements on a regional basis, with breath holds at volumes adjusted for differences in lung size across individuals according to the subject's vital capacity (VC). MATERIALS AND METHODS: This study was approved by the local institutional review board and was compliant with HIPAA. Informed consent was obtained from all subjects. Imaging was performed under a physician's Investigational New Drug application from the Food and Drug Administration. ADC changes as a function of inflation levels were evaluated in 24 healthy never-smokers across three lung volumes (20%, 60%, and 100% VC) on the basis of the spirometric data collected from each subject. Response variables based on lung volume and anatomic position were assessed with multifactorial analysis of variance followed by posthoc pair-wise testing. Imaging was performed with a 1.5-T magnetic resonance (MR) unit with use of a two-dimensional gradient-echo fast low-angle shot sequence. RESULTS: Significant differences in ADCs between lung volumes were observed for all inflation levels (20%, 60%, and 100% VC; P < .001), along with significant dependent-nondependent vertical gradients at 20% VC (P < .0001) and 60% VC (P < .0001, left lung only). In addition, significant differences between mean values in the left and right lungs with respect to those in the whole lung were observed at the lower lung inflation levels (20% and 60% VC, P < .01), reaching more uniform expansion at 100% VC. CONCLUSION: The results confirm known anatomic differences in patterns of regional inflation and ventilation with corresponding lung volume changes, emphasizing the need for tight control over lung volume when performing hyperpolarized helium 3 ((3)He) lung studies if (3)He MR imaging is to be used to follow up small longitudinal changes in lung abnormalities.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Pulmón/fisiología , Adulto , Anciano , Análisis de Varianza , Femenino , Helio , Humanos , Mediciones del Volumen Pulmonar , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Espirometría , Capacidad Vital
11.
Abdom Radiol (NY) ; 47(6): 2158-2167, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35320381

RESUMEN

PURPOSE: To compare the utility of a novel metal artifact reduction algorithm to standard imaging in improving visualization of key structures, diagnostic confidence, and patient-level confidence in malignancy in patients with suspected bladder cancer. METHODS: Patients with hip implants undergoing CT urography for suspected bladder malignancy were enrolled. Images were reconstructed using 3 methods: (1) Filtered Back Projection (FBP), (2) Iterative Metal Artifact Reduction (iMAR), and (3) Adaptive Iterative Metal Artifact Reduction (AiMAR) strength 4. In multiple reading sessions, three radiologists graded visualization of critical anatomic structures and artifact severity (6-point scales, lower scores desirable), and diagnostic confidence in blinded fashion. They also graded patient-level confidence in malignancy based on imaging findings in each patient. RESULTS: Thirty-two patients (8 females) with a mean age of 74.5 ± 8.5 years were included. The median (range) visualization scores for FBP, iMAR, and AiMAR were 3.6 (1.1-4.9), 1.6 (0.3-2.8), and 1.6 (0.3-2.6), respectively. Both iMAR and AiMAR had anatomic visualization and artifact scores better than FBP (P < 0.001 for both) and similar to each other (P > 0.05). Structures with the most improvement in visualization score with the use of metal artifact reduction algorithms included the obturator internus muscle, internal and external iliac nodal chains, and vagina. iMAR and AiMAR improved diagnostic confidence (P < 0.001) and patient-level confidence in malignancy (P ≤ 0.24). CONCLUSION: For patients with hip prostheses and suspected bladder malignancy, the use of iMAR or AiMAR was shown to significantly reduce metal artifacts, thus improving diagnostic confidence and patient-level confidence in malignancy.


Asunto(s)
Prótesis de Cadera , Neoplasias de la Vejiga Urinaria , Anciano , Anciano de 80 o más Años , Algoritmos , Artefactos , Femenino , Humanos , Masculino , Metales , Tomografía Computarizada por Rayos X/métodos , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen
12.
IEEE Trans Med Imaging ; 40(1): 251-261, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32956046

RESUMEN

Electrical impedance tomography is clinically used to trace ventilation related changes in electrical conductivity of lung tissue. Estimating regional pulmonary perfusion using electrical impedance tomography is still a matter of research. To support clinical decision making, reliable bedside information of pulmonary perfusion is needed. We introduce a method to robustly detect pulmonary perfusion based on indicator-enhanced electrical impedance tomography and validate it by dynamic multidetector computed tomography in two experimental models of acute respiratory distress syndrome. The acute injury was induced in a sublobar segment of the right lung by saline lavage or endotoxin instillation in eight anesthetized mechanically ventilated pigs. For electrical impedance tomography measurements, a conductive bolus (10% saline solution) was injected into the right ventricle during breath hold. Electrical impedance tomography perfusion images were reconstructed by linear and normalized Gauss-Newton reconstruction on a finite element mesh with subsequent element-wise signal and feature analysis. An iodinated contrast agent was used to compute pulmonary blood flow via dynamic multidetector computed tomography. Spatial perfusion was estimated based on first-pass indicator dilution for both electrical impedance and multidetector computed tomography and compared by Pearson correlation and Bland-Altman analysis. Strong correlation was found in dorsoventral (r = 0.92) and in right-to-left directions (r = 0.85) with good limits of agreement of 8.74% in eight lung segments. With a robust electrical impedance tomography perfusion estimation method, we found strong agreement between multidetector computed and electrical impedance tomography perfusion in healthy and regionally injured lungs and demonstrated feasibility of electrical impedance tomography perfusion imaging.


Asunto(s)
Síndrome de Dificultad Respiratoria , Animales , Impedancia Eléctrica , Pulmón/diagnóstico por imagen , Perfusión , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Porcinos , Tomografía , Tomografía Computarizada por Rayos X
13.
Acta Radiol Open ; 10(7): 20584601211030658, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34377539

RESUMEN

BACKGROUND: Due to their easy accessibility, CT scans have been increasingly used for investigation of gastrointestinal (GI) bleeding. PURPOSE: To estimate the performance of a dual-phase, dual-energy (DE) GI bleed CT protocol in patients with overt GI bleeding in clinical practice and examine the added value of portal phase and DE images. MATERIALS AND METHODS: Consecutive patients with GI bleeding underwent a two-phase DE GI bleed CT protocol. Two gastroenterologists established the reference standard. Performance was estimated using clinical CT reports. Three GI radiologists rated confidence in GI bleeding in a subset of 62 examinations, evaluating first mixed kV arterial images, then after examining additional portal venous phase images, and finally after additional DE images (virtual non-contrast and virtual monoenergetic 50 keV images). RESULTS: 52 of 176 patients (29.5%) had GI bleeding by the reference standard. The overall sensitivity, specificity, and positive and negative predictive values of the CT GI bleed protocol for detecting GI bleeding were 65.4%, 89.5%, 72.3%, and 86.0%, respectively. In patients with GI bleeding, diagnostic confidence of readers increased after adding portal phase images to arterial phase images (p = 0.002), without additional benefit from dual energy images. In patients without GI bleeding, confidence in luminal extravasation appropriately decreased after adding portal phase, and subsequently DE images (p = 0.006, p = 0.018). CONCLUSION: A two-phase DE GI bleed CT protocol had high specificity and negative predictive value in clinical practice. Portal venous phase images improved diagnostic confidence in comparison to arterial phase images alone. Dual-energy images further improved radiologist confidence in the absence of bleeding.

14.
J Med Imaging (Bellingham) ; 7(5): 053501, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33033732

RESUMEN

Purpose: Conventional stenosis quantification from single-energy computed tomography (SECT) images relies on segmentation of lumen boundaries, which suffers from partial volume averaging and calcium blooming effects. We present and evaluate a method for quantifying percent area stenosis using multienergy CT (MECT) images. Approach: We utilize material decomposition of MECT images to measure stenosis based on the ratio of iodine mass between vessel locations with and without a stenosis, thereby eliminating the requirement for segmentation of iodinated lumen. The method was first assessed using simulated MECT images created with different spatial resolutions. To experimentally assess this method, four phantoms with different stenosis severity (30% to 51%), vessel diameters (5.5 to 14 mm), and calcification densities (700 to 1100 mgHA / cc ) were fabricated. Conventional SECT images were acquired using a commercial CT system and were analyzed with commercial software. MECT images were acquired using a commercial dual-energy CT (DECT) system and also from a research photon-counting detector CT (PCD-CT) system. Three-material-decomposition was performed on MECT data, and iodine density maps were used to quantify stenosis. Clinical radiation doses were used for all data acquisitions. Results: Computer simulation verified that this method reduced partial volume and blooming effects, resulting in consistent stenosis measurements. Phantom experiments showed accurate and reproducible stenosis measurements from MECT images. For DECT and two-threshold PCD-CT images, the estimation errors were 4.0% to 7.0%, 2.0% to 9.0%, 10.0% to 18.0%, and - 1.0 % to - 5.0 % (ground truth: 51%, 51%, 51%, and 30%). For four-threshold PCD-CT images, the errors were 1.0% to 3.0%, 4.0% to 6.0%, - 1.0 % to 9.0%, and 0.0% to 6.0%. Errors using SECT were much larger, ranging from 4.4% to 46%, and were especially worse in the presence of dense calcifications. Conclusions: The proposed approach was shown to be insensitive to acquisition parameters, demonstrating the potential to improve the accuracy and precision of stenosis measurements in clinical practice.

15.
Abdom Radiol (NY) ; 45(1): 45-54, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31705250

RESUMEN

PURPOSE: Prior iterative reconstruction (PIR) spatially registers CT image data from multiple phases of enhancement to reduce image noise. We evaluated PIR in contrast-enhanced multiphase liver CT. METHODS: Patients with archived projection CT data with proven malignant or benign liver lesions, or without lesions, by reference criteria were included. Lower-dose PIR images were reconstructed using validated noise insertion from multiphase CT exams (50% dose in 2 phases, 25% dose in 1 phase). The phase of enhancement most relevant to the diagnostic task was selected for evaluation. Four radiologists reviewed routine-dose and lower-dose PIR images, circumscribing liver lesions and rating confidence for malignancy (0 to 100) and image quality. JAFROC Figures of Merit (FOM) were calculated. RESULTS: 31 patients had 60 liver lesions (28 primary hepatic malignancies, 6 hepatic metastases, 26 benign lesions). Pooled JAFROC FOM for malignancy for routine-dose CT was 0.615 (95% CI 0.464, 0.767) compared to 0.662 for PIR (95% CI 0.527, 0.797). The estimated FOM difference between the routine-dose and lower-dose PIR images was + 0.047 (95% CI - 0.023, + 0.116). Pooled sensitivity/specificity for routine-dose images was 70%/68% compared to 73%/66% for lower-dose PIR. Lower-dose PIR had lower diagnostic image quality (mean 3.8 vs. 4.2, p = 0.0009) and sharpness (mean 2.3 vs. 2.0, p = 0.0071). CONCLUSIONS: PIR is a promising method to reduce radiation dose for multiphase abdominal CT, preserving observer performance despite small reductions in image quality. Further work is warranted.


Asunto(s)
Competencia Clínica/estadística & datos numéricos , Neoplasias Hepáticas/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Proyectos Piloto , Intensificación de Imagen Radiográfica/métodos , Sensibilidad y Especificidad
16.
Curr Probl Diagn Radiol ; 48(2): 152-160, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30449721

RESUMEN

OBJECTIVE: Chest computed tomography (CT) imaging enables detailed visualization of the pulmonary structures and diseases. This article reviews how continued innovation and improvements in modern CT system hardware and software now facilitate a wider range of image acquisition options and generate unique qualitative and quantitative information that can benefit patients RESULTS: Dual energy imaging utilizes two x-ray energies to highlight differences in tissue properties and increase iodine signal to improve diagnosis or reduce metal artifacts. Ultra-low dose imaging can be performed by using additional x-ray beam filtration, such as a tin filter, combined with iterative reconstruction algorithms to benefit lung cancer screening or pediatric imaging. Ultra-fast pitch spiral acquisition improves temporal resolution and reduces motion artifacts. Higher spatial resolution acquisition and reconstruction methods permit improved visualization of small structures. Radiomic analysis of chest CT image features permits risk stratification of pulmonary nodules and masses and reliable measures of change in pulmonary architecture and disease. CONCLUSIONS: Multiple new CT acquisition and reconstruction techniques, along with advanced post processing methods permit detailed analysis of changes in pulmonary architecture and function, and an expanded ability to adapt chest CT to the unique needs of different patients.


Asunto(s)
Enfermedades Pulmonares/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Artefactos , Humanos
17.
Invest Radiol ; 54(3): 129-137, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30461437

RESUMEN

OBJECTIVES: The aim of this study was to evaluate if a high-resolution photon-counting detector computed tomography (PCD-CT) system with a 1024×1024 matrix reconstruction can improve the visualization of fine structures in the lungs compared with conventional high-resolution CT (HRCT). MATERIALS AND METHODS: Twenty-two adult patients referred for clinical chest HRCT (mean CTDI vol, 13.58 mGy) underwent additional dose-matched PCD-CT (mean volume CT dose index, 13.37 mGy) after written informed consent. Computed tomography images were reconstructed at a slice thickness of 1.5 mm and an image increment of 1 mm with our routine HRCT reconstruction kernels (B46 and Bv49) at 512 and 1024 matrix sizes for conventional energy-integrating detector (EID) CT scans. For PCD-CT, routine B46 kernel and an additional sharp kernel (Q65, unavailable for EID) images were reconstructed at 1024 matrix size. Two thoracic radiologists compared images from EID and PCD-CT noting the highest level bronchus clearly identified in each lobe of the right lung, and rating bronchial wall conspicuity of third- and fourth-order bronchi. Lung nodules were also compared with the B46/EID/512 images using a 5-point Likert scale. Statistical analysis was performed using a Wilcoxon signed rank test with a P < 0.05 considered significant. RESULTS: Compared with B46/EID/512, readers detected higher-order bronchi using B46/PCD/1024 and Q65/PCD/1024 images for every lung lobe (P < 0.0015), but in only the right middle lobe for B46/EID/1024 (P = 0.007). Readers were able to better identify bronchial walls of the third- and fourth-order bronchi better using the Q65/PCD/1024 images (mean Likert scores of 1.1 and 1.5), which was significantly higher compared with B46/EID/1024 or B46/PCD/1024 images (mean difference, 0.8; P < 0.0001). The Q65/PCD/1024 images had a mean nodule score of 1 ± 1.3 for reader 1, and -0.1 (0.9) for reader 2, with one reader having improved nodule evaluation scores for both PCD kernels (P < 0.001), and the other reader not identifying any increased advantage over B46/EID/1024 (P = 1.0). CONCLUSIONS: High-resolution lung PCD-CT with 1024 image matrix reconstruction increased radiologists' ability to visualize higher-order bronchi and bronchial walls without compromising nodule evaluation compared with current chest CT, creating an opportunity for radiologists to better evaluate airway pathology.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Fotones , Estudios Prospectivos , Radiografía Torácica/métodos , Reproducibilidad de los Resultados
18.
Abdom Radiol (NY) ; 44(10): 3350-3358, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31422439

RESUMEN

PURPOSE: Prior iterative reconstruction (PIR) uses spatial information from one phase of enhancement to reduce image noise in other phases. We sought to determine if PIR could reduce radiation dose while preserving observer performance and CT number at multi-phase dual energy (DE) renal CT. METHODS: CT projection data from multi-phase DE renal CT examinations were collected. Images corresponding to 40% radiation dose were reconstructed using validated noise insertion and PIR. Three genitourinary radiologists examined routine and 40% dose PIR images. Probability of malignancy was assessed [from 0 to 100] with malignancy assumed at probability ≥ 75. Observer performance was compared on a per patient and per lesion level. CT number accuracy was measured. RESULTS: Twenty-three patients had 49 renal lesions (11 solid renal neoplasms). CT number was nearly identical between techniques (mean CT number difference: unenhanced 2 ± 2 HU; enhanced 4 ± 4 HU). AUC for malignancy was similar between multi-phase routine dose DE and lower dose PIR images [per patient: 0.950 vs. 0.916 (p = 0.356); per lesion: 0.931 vs. 0.884 (p = 0.304)]. Per patient sensitivity was also similar (78% routine dose vs. 82% lower dose [p ≥ 0.99]), as was specificity (91% routine dose vs. 93% lower dose PIR [p > 0.99]), with similar findings on a per lesion level. Subjective image quality was also similar (p = 0.34). CONCLUSIONS: Prior iterative reconstruction is a new reconstruction method for multi-phase CT examinations that promises to facilitate radiation dose reduction by over 50% for multi-phase DE renal CT exams without compromising CT number or observer performance.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Yohexol , Masculino , Persona de Mediana Edad , Proyectos Piloto , Imagen Radiográfica por Emisión de Doble Fotón , Estudios Retrospectivos
19.
Acad Radiol ; 25(10): 1270-1276, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29454545

RESUMEN

RATIONAL AND OBJECTIVES: This study aims to investigate the performance of a whole-body, photon-counting detector (PCD) computed tomography (CT) system in differentiating urinary stone composition. MATERIALS AND METHODS: Eighty-seven human urinary stones with pure mineral composition were placed in four anthropomorphic water phantoms (35-50 cm lateral dimension) and scanned on a PCD-CT system at 100, 120, and 140 kV. For each phantom size, tube current was selected to match CTDIvol (volume CT dose index) to our clinical practice. Energy thresholds at [25, 65], [25, 70], and [25, 75] keV for 100, 120, and 140 kV, respectively, were used to generate dual-energy images. Each stone was automatically segmented using in-house software; CT number ratios were calculated and used to differentiate stone types in a receiver operating characteristic (ROC) analysis. A comparison with second- and third-generation dual-source, dual-energy CT scanners with conventional energy integrating detectors (EIDs) was performed under matching conditions. RESULTS: For all investigated settings and smaller phantoms, perfect separation between uric acid and non-uric acid stones was achieved (area under the ROC curve [AUC] = 1). For smaller phantoms, performance in differentiation of calcium oxalate and apatite stones was also similar between the three scanners: for the 35-cm phantom size, AUC values of 0.76, 0.79, and 0.80 were recorded for the second- and third-generation EID-CT and for the PCD-CT, respectively. For larger phantoms, PCD-CT and the third-generation EID-CT outperformed the second-generation EID-CT for both differentiation tasks: for a 50-cm phantom size and a uric acid/non-uric acid differentiating task, AUC values of 0.63, 0.95, and 0.99 were recorded for the second- and third-generation EID-CT and for the PCD-CT, respectively. CONCLUSION: PCD-CT provides comparable performance to state-of-the-art EID-CT in differentiating urinary stone composition.


Asunto(s)
Tomografía Computarizada por Rayos X , Cálculos Urinarios/química , Cálculos Urinarios/diagnóstico por imagen , Oxalato de Calcio , Humanos , Fantasmas de Imagen , Fotones , Curva ROC , Ácido Úrico
20.
Invest Radiol ; 53(11): 655-662, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29847412

RESUMEN

OBJECTIVE: The aims of this study were to quantitatively assess two new scan modes on a photon-counting detector computed tomography system, each designed to maximize spatial resolution, and to qualitatively demonstrate potential clinical impact using patient data. MATERIALS AND METHODS: This Health Insurance Portability Act-compliant study was approved by our institutional review board. Two high-spatial-resolution scan modes (Sharp and UHR) were evaluated using phantoms to quantify spatial resolution and image noise, and results were compared with the standard mode (Macro). Patients were scanned using a conventional energy-integrating detector scanner and the photon-counting detector scanner using the same radiation dose. In first patient images, anatomic details were qualitatively evaluated to demonstrate potential clinical impact. RESULTS: Sharp and UHR modes had a 69% and 87% improvement in in-plane spatial resolution, respectively, compared with Macro mode (10% modulation-translation-function values of 16.05, 17.69, and 9.48 lp/cm, respectively). The cutoff spatial frequency of the UHR mode (32.4 lp/cm) corresponded to a limiting spatial resolution of 150 µm. The full-width-at-half-maximum values of the section sensitivity profiles were 0.41, 0.44, and 0.67 mm for the thinnest image thickness for each mode (0.25, 0.25, and 0.5 mm, respectively). At the same in-plane spatial resolution, Sharp and UHR images had up to 15% lower noise than Macro images. Patient images acquired in Sharp mode demonstrated better delineation of fine anatomic structures compared with Macro mode images. CONCLUSIONS: Phantom studies demonstrated superior resolution and noise properties for the Sharp and UHR modes relative to the standard Macro mode and patient images demonstrated the potential benefit of these scan modes for clinical practice.


Asunto(s)
Cálculos Renales/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Hombro/diagnóstico por imagen , Cráneo/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Humanos , Fantasmas de Imagen , Fotones , Estudios Prospectivos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA