1.
Clin Chem Lab Med ; 2024 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-39323320

RESUMEN

OBJECTIVES: Serum cystatin C (CysC) is a reliable and ideal endogenous marker for accurately assessing early changes in glomerular filtration rate (GFR), surpassing the limitations of creatinine-based estimated GFR. To improve the precision of GFR calculation, the development of strategies for accurately measuring serum CysC is crucial. METHODS: In this study, the full-length CysC pure product and fully recombinant 15N-labeled CysC internal standard were subjected to protein cleavage. Subsequently, an LC-MS/MS method was developed for the absolute quantification of serum CysC. The traceability of the method was assigned calibrator using the amino acid reference measurement procedure (RMP). It involved calibrating the instrument using an amino acid reference material with known amino acid concentrations for calibration and comparison purposes. RESULTS: The total imprecision of the method was determined to be ≤8.2 %, and a lower functional limit of quantification (LLoQ) was achieved. The recoveries ranged from 97.36 to 103.26 %. The relative bias between this candidate RMP for measurement of ERM-DA471-IFCC and the target value was 1.74 %. The linearity response was observed within the concentration range of 0.21-10.13 mg/L, with a high R2 value of 0.999. The results obtained using our method was consistent with those obtained using other certified RMPs. CONCLUSIONS: With the establishment of this highly selective and accurate serum CysC measurement method, it is now possible to assess the correlation between immunoassay results of serum CysC and the intended target when discrepancies are suspected in the clinical setting.

2.
Anal Bioanal Chem ; 416(22): 4897-4906, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38953919

RESUMEN

A candidate reference measurement procedure (RMP) for serum theophylline via isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. With a single-step precipitation pretreatment and a 6-min gradient elution, the method achieved baseline separation of theophylline and its analogs on a C18-packed column. A bracketing calibration method was used to ensure repeatable signal intensity and high measurement precision. The intra-assay and inter-assay imprecisions were 1.06%, 0.84%, 0.72% and 0.47%, 0.41%, 0.25% at concentrations of 4.22 µg/mL (23.40 µmol/L), 8.45 µg/mL (46.90 µmol/L), and 15.21 µg/mL (84.43 µmol/L), respectively. Recoveries ranged from 99.35 to 102.34%. The limit of detection (LoD) was 2 ng/mL, and the lowest limit of quantification (LLoQ) was 5 ng/mL. The linearity range extended from 0.47 to 60 µg/mL (2.61-333.04 µmol/L). No ion suppression and carry-over (< 0.68%) were observed. The relative bias for this candidate RMP that participated in 2023 External Quality Control for Reference Laboratories (RELA) conducted by the International Federation of Clinical Chemistry (IFCC) was within a range of 0.17 to 0.93%. Furthermore, two clinical immunoassay systems were compared with this candidate RMP, demonstrating good correlations. The results of the Trueness Verification Plan indicate significant differences among routine systems, highlighting the need for standardization efforts. The developed candidate RMP for serum theophylline serves as a precise reference baseline for standardizing clinical systems and assigning values to reference materials.


Asunto(s)
Límite de Detección , Espectrometría de Masas en Tándem , Teofilina , Teofilina/sangre , Espectrometría de Masas en Tándem/métodos , Humanos , Calibración , Cromatografía Liquida/métodos , Estándares de Referencia , Técnicas de Dilución del Indicador , Reproducibilidad de los Resultados
3.
Anal Bioanal Chem ; 415(23): 5637-5644, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37490154

RESUMEN

We developed and evaluated two-level, namely 2017011 and 2017012, serum-based reference materials (RMs) for 17 beta-estradiol (17 ß-E2) by the reference method of isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS) from the remaining serum samples after routine clinical tests, to help improve clinical routine testing and provide the traceability of results. This paper describes the development process of these RMs. The National Metrology Institute of Japan (NMIJ) certified reference material (CRM) 6004-a was used as the primary RM for the measurement of 17 ß-E2. These serum-based RMs showed satisfactory homogeneity and stability. They also assessed the commutability between the reference method and the three routine clinical immunoassay systems. Besides, a collaborative study was carried out in five reference laboratories, all of which had been accredited by the China National Accreditation Service for Conformity Assessment (CNAS) in accordance with ISO/WD 15725-1. Statistical analysis of raw results and uncertainty assessment obtained certified values: 2017011 was 445.2 ± 39.0 pmol/L, and 2017012 was 761.9 ± 35.5 pmol/L.


Asunto(s)
Estradiol , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Técnicas de Dilución del Indicador , Isótopos , Estándares de Referencia
4.
Anal Bioanal Chem ; 414(7): 2523-2531, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35211786

RESUMEN

To solve long-term lack of traceability of commercial calibrator kits and standardize clinical routine assays, we developed a human serum matrix-based unconjugated estriol (uE3) reference material (RM) with five concentration gradients. The RMs of uE3 were certified by the National Institute of Metrology (NIM) with the codes of GBW (E) 091048, GBW (E) 091049, GBW (E) 091050, GBW (E) 091051, and GBW (E) 091052. The RMs were determined by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) reference method which was developed in our group and recommended by the Joint Committee on Traceability on Laboratory Medicine (JCTLM). GBW09224 is intended for use as a primary reference material to enable the SI-traceable measurement of uE3. This study describes the development process of these certified RMs. The candidate material was prepared by collecting from the remaining serum samples after routine clinical testing. Satisfactory homogeneity and stability were shown in these RMs. They are also commutable between the reference method and the three routine clinical immunoassay systems. To improve the accuracy of value assignment, a collaborative study in nine reference laboratories was conducted which was performed according to ISO/WD 15725-1 and all of the reference laboratories have been confirmed by China National Accreditation Service for Conformity Assessment (CNAS). The raw results were statistically analyzed and processed, coupled with uncertainty evaluation, to obtain the certified value: GBW (E) 091048 is 22.1 ± 1.3 nmol/L, GBW (E) 091049 is 33.6 ± 1.6 nmol/L, GBW (E) 091050 is 10.4 ± 0.8 nmol/L, GBW (E) 091051 is 15.5 ± 1.0 nmol/L, GBW (E) 091052 is 47.0 ± 2.0 nmol/L. The preparation process of human serum matrix-based reference material and the lack of these type of secondary (commutable) reference material of unconjugated estriol lead to the interruption of its traceability chain, which is a problem to be solved in its standardization as mentioned in the metrological traceability in ISO 17511, 2020.


Asunto(s)
Estriol , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Humanos , Técnica de Dilución de Radioisótopos , Estándares de Referencia , Espectrometría de Masas en Tándem/métodos
5.
J Clin Lab Anal ; 36(2): e24206, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34957600

RESUMEN

BACKGROUND: Serum creatinine (SCr) is a useful diagnostic marker for the assessment of renal function. Accurate quantitation of SCr is clinically important in calculation of glomerular filtration rate (GFR). METHOD: To confirm whether there are differences in SCr between enzymatic kits of different manufacturers, the analytical performance of the matched and open test system in the measurement of SCr was evaluated. The analytical performance evaluation was conducted according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. Precision, accuracy, linearity, dilution, lower limit of measurement and analytical interference were studied between the two test systems. RESULTS: The performance of SCr from the open test system was in compliance with the matched test system with good precision, accuracy, and linearity. In presence of most common interferents, both test systems could lead to accurate creatinine results except for the existence of specified drugs. For dobutamine, the open test system showed better anti-interference performance than the matched system. CONCLUSION: This study provides referable opinions for clinical laboratory selection on the test system and a framework for future analogous studies based on different test systems.


Asunto(s)
Creatinina/sangre , Pruebas de Función Renal/métodos , Humanos , Ensayo de Materiales
6.
Protein Expr Purif ; 178: 105785, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33152458

RESUMEN

Isotope-labeled proteins are expected to be used as internal standard proteins in the field of protein quantification by isotope dilution mass spectrometry (ID/MS). To achieve the absolute quantification of Cystatin C (Cys C) based on ID/MS, we aims to obtain 15N isotope-labeled recombinant Cys C (15N-Cys C) protein. Firstly, the Cys C gene was optimized based on the preferred codons of Escherichia coli, and inserted into the pET-28a(+) expression plasmid. Then, the plasmid was transformed into TOP10 and BL21 strains, and 15N-Cys C was expressed in M9 medium using 15N as the only nitrogen source. 15N-Cys C was detected by SDS-PAGE, protein immunoblotting and matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). The characteristic peptides obtained from 15N-Cys C were analyzed by a Q Exactive Plus MS system. Results showed that 53.06% of the codons were optimized. The codon adaptation index of the Cys C genes increased from 0.31 to 0.95, and the GC content was adjusted from 64.85% to 54.88%. The purity of 15N-Cys C was higher than 95%. MALDI-TOF MS analysis showed that the m/z of 15N-Cys C had changed from 13 449 to 14 850. The characteristic peptides showed that 619.79 m/z (M+2H)2+ was the parent ion of 15N-Cys C and that the secondary ions of 15N-labeled peptides from y+5 to y+9 were 616.27 m/z, 716.33 m/z, 788.39 m/z, 936.43 m/z, and 1052.46 m/z, respectively. In conclusion, we successfully expressed, purified and identified of 15N-Cys C protein in Escheichia coli intended for absolute quantification using ID/MS.


Asunto(s)
Cistatina C , Escherichia coli , Expresión Génica , Isótopos de Nitrógeno/química , Cistatina C/biosíntesis , Cistatina C/genética , Escherichia coli/química , Escherichia coli/genética , Escherichia coli/metabolismo , Humanos , Espectrometría de Masas , Proteínas Recombinantes/biosíntesis , Proteínas Recombinantes/química , Proteínas Recombinantes/genética
7.
Anal Bioanal Chem ; 413(17): 4471-4481, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34018033

RESUMEN

Accurate quantitation of aldosterone is clinically important in standardized testing for primary aldosteronism. The results are often variable when performed by clinical immunoassays. To standardize and ensure the accuracy of clinical systems, reference measurement procedures (RMPs) with higher metrological order are required. A simple and reliable isotope dilution LC-IDMS/MS-based measurement procedure for human plasma aldosterone has been developed. This method involved plasma spiked with a deuterium-labelled internal standard, equilibrated for 0.5 h, and extracted by liquid-liquid extraction (LLE) without derivatization. Aldosterone and its structural analogues were baseline separated with a C18-packed UHPLC column with gradient elution within 7 min. The signal intensity variability and measurement imprecision were reduced by bracketing calibration during plasma aldosterone value assignment. The limit of detection (LoD) was 19.4 pmol/L with a signal-to-noise ratio (S/N) > 3. The lowest limit of quantification (LLoQ) was 27.7 pmol/L (S/N > 10 and CV < 10.0%). LLE was performed with 1 mL of n-hexane/ethyl acetate (3:2, v/v), and the extraction recovery was determined to be 92.15 ± 3.54%. The imprecisions were ≤ 3.18% for samples at 124.8, 867.0, and 2628.5 pmol/L. The recoveries were 98.11-101.61%. The relative bias between this candidate RMP and the established RMP was 2.76-1.89%. The linearity response ranged from 27.7 to 2774.4 pmol/L with R2 = 0.999. The method performance met the requirements of RMPs (≤ 5% total CV and ≤ 3% bias). Furthermore, the developed method was applied to evaluate immunoassays through 41 patient sample comparisons. The calibration and measurement capability (CMC) of this method were also evaluated by measuring these samples. The candidate RMP can serve as an accurate reference baseline for routine methods and can be used for value assignment for reference materials. Selected ion chromatograms by LC-MS/MS using a C18 column for aldosterone and its structural analogues.


Asunto(s)
Aldosterona/sangre , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Humanos , Técnicas de Dilución del Indicador , Isótopos/sangre , Límite de Detección , Extracción Líquido-Líquido/métodos
8.
Clin Lab ; 67(3)2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33739036

RESUMEN

BACKGROUND: The aim of this study is to verify the analytical performance of four homocysteine detection systems made in China and to explore the comparability of homocysteine detection systems by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) reference method. METHODS: The intra-batch precision, inter-batch precision, accuracy, and linear range of four homocysteine detection systems were evaluated. The ID-LC-MS/MS reference method was used to evaluate the comparability and accuracy of fresh frozen serum samples in four different detection systems of homocysteine. The ID-LC-MS/MS reference method is used to assign samples as calibrators to calibrate each system. The variation and deviation of fresh serum samples between different systems before and after calibration were compared. RESULTS: The intra-batch imprecision of the four detection systems was less than 5%, and the coefficient of variation of inter-batch imprecision was less than 6.7%. The precision met the clinical requirements. Before calibration, the results measured by detection system 2 are consistent with the ID-LC-MS/MS reference method, which meets the requirements of accuracy verification. The regression equation of R² ≥ 0.975 in the regression equation of linear analysis of the four systems, the linearity of the four detection systems is good in the range of evaluation concentration, and all of them can meet the declared linear range. The absolute average bias of fresh serum measured by the four detection systems after calibration decreased from 3.76 µmol/L, 0.96 µmol/L, 1.30 µmol/L, -1.56 µmol/L to 0.31 µmol/L, 0.28 µmol/L, 0.4 µmol/L, 0.40 µmol/L, respectively. The relative average bias decreased from 22.6%, 7.50%, 11.0% and -8.50% to 1.98%, 1.78%, 2.59%, 2.34%, respectively. After calibration, the slope and intercept of the regression curve of the fresh serum measured by the four detection systems and the reference method are closer to 1 and 0 than before calibration. CONCLUSIONS: The precision, reference interval, and linear evaluation of the four detection systems are good. The ID-LC-MS/MS reference method assigning fresh frozen serum samples as calibrators can improve the accuracy and comparability of the results of different detection systems.


Asunto(s)
Homocisteína , Espectrometría de Masas en Tándem , Calibración , China , Cromatografía Liquida , Humanos
9.
Addict Biol ; 25(2): e12687, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-30421575

RESUMEN

Addictions, both substance and behavioral, have been conceptualized as involving similar biopsychosocial processes with different opportunistic expressions. A maladaptive stress response in combination with craving or urges to engage in the addictive behavior may be among the underlying factors common to behavioral and substance addictions. The current study compared the neuroendocrine (cortisol) and subjective responses to stress of gamblers and smokers to healthy controls. We assessed if participants responded differently to smoking or gambling cues before and after a psychosocial stressor. To this end, the subjective urges/cravings of all participants were measured in response to smoking or gambling cues versus neutral cues, once under normal conditions and again after exposure to a stressor. Salivary cortisol was measured prior to, immediately following, and 10 minutes after conclusion of the stressor. Smokers and gamblers showed a similar blunted cortisol response to the acute stressor that differed from the control group's response. Following a stressor, subjective craving in smokers increased whereas gamblers' urges decreased. In smokers, a blunted cortisol and subjective stress response were related to increased urges. In contrast, for gamblers, changes in cortisol levels were unrelated to urges, and higher subjective stress was associated with decreased urges. In conclusion, individuals with a substance and a behavioral addiction share common patterns of reactivity to stress. However, while the stressor enhanced cue-related craving in smokers, it generally had the opposite effect on gamblers. Further research is necessary to elucidate the complicated patterns of similarities and differences that underlie substance and behavioral addictions.


Asunto(s)
Señales (Psicología) , Juego de Azar/metabolismo , Juego de Azar/fisiopatología , Estrés Psicológico/metabolismo , Tabaquismo/metabolismo , Tabaquismo/fisiopatología , Adulto , Femenino , Juego de Azar/psicología , Humanos , Hidrocortisona/metabolismo , Masculino , Saliva/metabolismo , Índice de Severidad de la Enfermedad , Fumadores , Estrés Psicológico/fisiopatología , Estrés Psicológico/psicología , Tabaquismo/psicología
10.
Anal Biochem ; 587: 113462, 2019 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-31585098

RESUMEN

Adenosine deaminase (ADA) is a key enzyme of adenosine metabolism. There are currently various kits and systems available for ADA measurement, and all yield variable results. This study optimized a reference measurement procedure (RMP) for serum ADA for the standardization of routine methods. ADA coupled with purine-nucleoside-phosphorylase, xanthine-oxidase and peroxidase was selected as the basic method and was optimized using Response Surface Methodology. Then the performance was validated and the results were compared after replication by 3 other reference laboratories. A reference interval was also developed. In addition, this optimized method was applied to calibrate a routine system. The intra-assay precision was 0.44% at both concentrations of 29.8 and 100.4 U/L, and inter-assay precision was 1.01% and 0.95% at 30.1 and 100.3 U/L, respectively. The linearity was up to 351.9 U/L (R2 = 0.9998), with no significant interference or carryover (<5%). A Comparison among 4 reference laboratories showed good reproducibility (R2 ≥ 0.9975). The procedure proved valid for a reference interval of 11.7-38.5 U/L. The mean relative deviation for a routine system was -55.9% and -3.7% before and after calibration. This candidate RMP for serum ADA can potentially be used for standardization of clinical systems.


Asunto(s)
Adenosina Desaminasa/sangre , Pruebas de Enzimas , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Espectrofotometría , Propiedades de Superficie , Adulto Joven
11.
Anal Bioanal Chem ; 411(6): 1203-1210, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30612174

RESUMEN

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) for measurements of steroids in human saliva has garnered increased interest in the area of clinical psychoneuroendocrinological research. However, performance characteristics of LC-MS/MS methods for the analysis of steroids in saliva are limited. Human saliva samples were collected via passive drool. Cortisol and dehydroepiandrosterone sulfate (DHEA-S) in the samples were extracted together, resolved on a C18-A column, and analyzed using tandem mass spectrometry. The LC-MS/MS method had limits of quantitation of 0.03 and 0.06 ng/mL for DHEA-S and cortisol, respectively. Method evaluations showed coefficient variation (%CV) of inter-assay ranging 4.6-17.9% for DHEA-S and cortisol, recoveries of 102.4-109.5% for DHEA-S and 94.6-98.3% for cortisol, and assay linearity with R2 = 0.9964 for DHEA-S (1.0-25.0 ng/mL) and R2 = 0.997 (1.0-25.0 ng/mL) for cortisol. No cross contamination among samples was observed. Human saliva showed 20% and 18% ion enhancement effect for DHEA-S and cortisol assay, respectively. No interference by ten common steroids was detected. Regression analysis of method comparisons with laboratory-developed test (LDT) method revealed R2 = 0.9688 (LC-MS/MS = 0.9665 LDT-LC-MS/MS - 0.7355) for cortisol, and R2 = 0.9039 (LC-MS/MS = 1.0173 LDT-LC-MS/MS + 3.6797) for DHEA-S. Reference ranges for young adults were determined to be 0.3-5.9 ng/mL for females and 0.1-5.6 ng/mL for males for salivary cortisol, and 0.6-7.4 ng/mL for females and 0.6-10.1 ng/mL for males for salivary DHEA-S. An LC-MS/MS method for quantifying cortisol and DHEA-S in human saliva was developed and validated for clinical and psychoneuroendocrinological research that require noninvasive means of measuring these hormones.


Asunto(s)
Sulfato de Deshidroepiandrosterona/análisis , Hidrocortisona/análisis , Saliva/química , Espectrometría de Masas en Tándem/métodos , Adolescente , Adulto , Cromatografía Liquida/métodos , Femenino , Humanos , Límite de Detección , Masculino , Valores de Referencia , Adulto Joven
12.
Anal Bioanal Chem ; 411(2): 395-402, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30456606

RESUMEN

Immunoassays for measuring 17-hydroxyprogesterone (17-OHP) produce high rates of false positives that impact the identification of congenital adrenal hyperplasia (CAH) in neonates. A confirmatory test with high analytical specificity employing liquid chromatography-tandem mass spectrometry (LC-MS/MS) methodology is needed in newborn screening for CAH. 17-OHP and cortisol were extracted from dried blood spot (DBS) samples, resolved on a C18 column, and measured using tandem mass spectrometry. The results were compared with those determined using the AutoDELFIA immunoassay. The LC-MS/MS method had a limit of quantitation of 10.0 and 5.0 ng/mL for 17-OHP and cortisol, respectively. The method characteristics showed coefficient variation (%CV) ≤ 11.9% for both 17-OHP and cortisol, recoveries ranging from 83.1 to 101.5% for 17-OHP and from 95.1 to 102.8% for cortisol, and linearity with R2 = 0.9994 for 17-OHP and R2 = 0.9996 for cortisol, clinical sensitivity of 100.0% and a specificity of 96.4% as obtained by receiver operating characteristic analysis on 45 patient samples when 17-OHP > 39.1 ng/mL was selected as the cutoff value. Comparison between the LC-MS/MS and the AutoDELFIA immunoassay methods revealed a poor correlation for patient DBS samples (R2 = 0.6784); however, an excellent correlation was obtained for QC and proficiency test (PT) DBS samples (R2 = 0.9797). The LC-MS/MS method produced reliable results for 17-OHP and cortisol for the diagnosis of CAH. The AutoDELFIA immunoassay appears to be subject to matrix effects in the analysis for 17-OHP in DBS patient samples. The DBS samples of non-patient origin may not be suitable for assessing analytical accuracy of immunoassays.


Asunto(s)
17-alfa-Hidroxiprogesterona/sangre , Cromatografía Liquida , Inmunoensayo/métodos , Espectrometría de Masas en Tándem , 17-alfa-Hidroxiprogesterona/química , Humanos , Recién Nacido , Estructura Molecular , Sensibilidad y Especificidad , Pruebas Serológicas
13.
Anal Bioanal Chem ; 411(27): 7095-7104, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31673753

RESUMEN

A candidate reference measurement procedure (RMP) based on isotope dilution coupled with liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was developed and validated for the quantification of 17α-hydroxyprogesterone (17-OHP) in human plasma. 17-OHP spiked with a deuterium-labeled internal standard was extracted from plasma by liquid-liquid extraction with 1 mL n-hexane/ethyl acetate (3:2, v/v). Reversed-phase chromatography and positive electrospray ionization were used in the ID-LC-MS/MS. Gradient elution coupled with use of a C18-packed ultrahigh-performance liquid chromatography column allowed complete baseline resolution of 17-OHP from its structural analogue desoxycorticosterone in 6 min. To determine the 17-OHP level in human plasma, a bracketing calibration method was used to give higher accuracy and precision. The limit of detection and the lower limit of the measuring interval for the candidate RMP were 2.1 pg/mL (6.4 pmol/L) and 4.6 pg/mL (13.9 pmol/L), respectively. Extraction recovery was determined to be (96.08 ± 3.03)% (n = 3). Imprecision (intra-assay and interassay) was 4.03% or less at 0.83, 15.19, 64.22, and 313.46 ng/mL (2.51, 45.97, 194.34, and 948.56 nmol/L, respectively). Recoveries ranged from 98.05% to 102.24%. When comparing our RMP results with those obtained with an established RMP via International Federation of Clinical Chemistry and Laboratory Medicine external quality assessment scheme for reference laboratories in laboratory medicine (RELA) samples, we found that the biases ranged from -1.99% to 3.08% against the targets. No interference was observed, and the linear response ranged from 0.47 to 958.63 ng/mL (1.42 to 2900.90 nmol/L). Moreover, the candidate RMP was used to measure the concentration of 17-OHP in human plasma and was compared with an immunoassay using 40 plasma samples. The performance of the method meets the needs of an RMP (total coefficient of variation of 5% or less and bias of 3.08% or less). This method can be used for reference material value assignment of 17-OHP in human plasma matrix. It could also serve as an accurate reference baseline for routine methods to increase the accuracy and precision of certain clinical laboratory measurements. Graphical abstract Selected ion chromatograms obtained by liquid chromatography-tandem mass spectrometry with a C18 column for 17α-hydroxyprogesterone (17-OHP) from a plasma sample.


Asunto(s)
17-alfa-Hidroxiprogesterona/sangre , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Calibración , Cromatografía Líquida de Alta Presión/normas , Deuterio/sangre , Humanos , Técnicas de Dilución del Indicador , Marcaje Isotópico , Estándares de Referencia , Valores de Referencia , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem/normas
14.
Anal Bioanal Chem ; 410(24): 6257-6267, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30006726

RESUMEN

A candidate reference measurement procedure (RMP) for measurement of unconjugated estriol in human serum has been developed and validated. The proposed method is highly reliable and uses isotope dilution coupled with liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) and requires no derivatization. An appropriate amount of serum was accurately weighed and spiked with an isotopically labeled internal standard. Unconjugated estriol and its internal standard were extracted from serum matrix using liquid-liquid extraction prior to reversed-phase LC-MS/MS. Calibrator bracketing was used to give higher specificity and accuracy for assigning serum level. The accuracy of the candidate RMP was validated by split-sample comparison to established RMPs. The lowest limit of detection (LLoD) and lowest limit of quantification (LLoQ) for developed RMP was estimated to be 0.14 nmol/L and 0.35 nmol/L, respectively. Both intra- and inter-assay imprecisions were ≤2.19% at 1.39, 17.34 and 69.35 nmol/L, respectively. Recoveries were 98.54% to 100.34% and linear response ranged from 0.35 to 173.38 nmol/L. No interference was observed. Biases were 5.6% and 2.8% against the targets of RELA2015A (3.87 nmol/L) and RELA2015B (40.62 nmol/L), respectively. Moreover, the candidate RMP was successfully applied to measure level of unconjugated estriol in serum samples of pregnant women (n = 3) and compared with two immunoassays in clinical laboratory. Our developed method is simple, accurate, and can be used as a candidate RMP to determine total unconjugated estriol level in human serum. Further improvement of certain immunoassays in accuracy and precision is needed. Graphical abstract Selected ion chromatograms by LC-MS/MS using a C18 column for uE3 from a serum sample.


Asunto(s)
Cromatografía Liquida/métodos , Estriol/sangre , Inmunoensayo/métodos , Espectrometría de Masas en Tándem/métodos , Calibración , Estriol/normas , Femenino , Humanos , Límite de Detección , Embarazo , Estándares de Referencia , Reproducibilidad de los Resultados , Incertidumbre
15.
Hum Mol Genet ; 24(17): 4901-15, 2015 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-26089203

RESUMEN

DDX11 was recently identified as a cause of Warsaw breakage syndrome (WABS). However, the functional mechanism of DDX11 and the contribution of clinically described mutations to the pathogenesis of WABS are elusive. Here, we show that DDX11 is a novel nucleolar protein that preferentially binds to hypomethylated active ribosomal DNA (rDNA) gene loci, where it interacts with upstream binding factor (UBF) and the RNA polymerase I (Pol I). DDX11 knockdown changed the epigenetic state of rDNA loci from euchromatic structures to more heterochromatic structures, reduced the activity of UBF, decreased the recruitment of UBF and RPA194 (a subunit of Pol I) to rDNA promoter, suppressed rRNA transcription and thereby inhibited growth and proliferation of HeLa cells. Importantly, two indentified WABS-derived mutants, R263Q and K897del, and a Fe-S deletion construct demonstrated significantly reduced binding abilities to rDNA promoters and lowered DNA-dependent ATPase activities compared with wild-type DDX11. Knockdown of the zebrafish ortholog of human DDX11 by morpholinos resulted in growth retardation and vertebral and craniofacial malformations in zebrafish, concomitant with the changes in histone epigenetic modifications at rDNA loci, the reduction of Pol I recruitment to the rDNA promoter and a significant decrease in nascent pre-RNA levels. These growth disruptions in zebrafish in response to DDX11 reduction showed similarities to the clinically described developmental abnormalities found in WABS patients for the first time in any vertebrate. Thus, our results indicate that DDX11 functions as a positive regulator of rRNA transcription and provides a novel insight into the pathogenesis of WABS.


Asunto(s)
ARN Helicasas DEAD-box/genética , ARN Helicasas DEAD-box/metabolismo , ADN Helicasas/genética , ADN Helicasas/metabolismo , Desarrollo Embrionario/genética , ARN Ribosómico/biosíntesis , Animales , Nucléolo Celular/metabolismo , Proliferación Celular , ARN Helicasas DEAD-box/química , ADN Helicasas/química , Regulación de la Expresión Génica , Técnicas de Silenciamiento del Gen , Células HeLa , Humanos , Mutación , Proteínas del Complejo de Iniciación de Transcripción Pol1/metabolismo , Regiones Promotoras Genéticas , Unión Proteica , Transporte de Proteínas , ARN Interferente Pequeño/genética , Transcripción Genética , Pez Cebra
16.
Anal Bioanal Chem ; 409(10): 2627-2638, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28224243

RESUMEN

Estrogen measurements are important in the assessment of female reproductive function and have expanding roles in other fields. A simple, accurate, highly sensitive and specific isotope-dilution liquid chromatography-tandem mass spectrometry method was developed and evaluated to simultaneously measure three endogenous estrogens in serum: estrone (E1), 17ß-estradiol (E2), and estriol (E3). Chromatographic separation was achieved on a C18 column before electrospray ionization triple-quadrupole mass spectrometry in multiple reaction monitoring mode. The sample preparation in this assay requires no derivatization and extraction by liquid-liquid extraction. After optimization of the extraction conditions, the final extraction efficiency of E1, E2, and E3 was 83.8%, 78.9%, and 77.3% respectively. The metabolites and structural analogs that have the same molecular masses as the estrogens were separated under the optimized liquid chromatography conditions. Method validation showed satisfactory linearity over the concentration range of 20-10000 pg mL-1 for all three estrogens (r 2 > 0.997). The limits of quantification were 5, 10, and 10 pg mL-1 for E1, E2, and E3 respectively, and their recoveries ranged from 94.7% to 103.5%. The accuracy of the proposed method was further evaluated with use of certified reference materials BCR-576, BCR-577, and BCR-578 for E2 and 2014 International Federation of Clinical Chemistry and Laboratory Medicine External Quality Assessment Scheme for Reference Laboratories in Laboratory Medicine samples for E3, whose certified values were determined by reference methods. Great agreement was observed between the measured values and the certified values. Satisfactory precision (coefficients of variation less than 7.44%) was also obtained for the three estrogens. Moreover, the proposed method was successfully applied to measure the three estrogens in serum samples of pregnant women in the second trimester and to assess the accuracy of chemiluminescent immunoassays in clinical laboratories by determination of E2 and unconjugated E3 in serum samples. Graphical Abstract Schematic representation of the simultaneous quantitation of three major endogenous estrogens in human serum by ID-LC-MS/MS.


Asunto(s)
Cromatografía Liquida/métodos , Técnicas de Laboratorio Clínico/normas , Estradiol/sangre , Estriol/sangre , Estrona/sangre , Espectrometría de Masas en Tándem/métodos , Femenino , Humanos , Técnicas de Dilución del Indicador , Marcaje Isotópico , Embarazo , Segundo Trimestre del Embarazo
17.
Clin Chem Lab Med ; 54(4): 659-65, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26426894

RESUMEN

BACKGROUND: Serum alkaline phosphatase (ALP) plays a critical role in the diagnosis of various diseases, and the establishment of relevant, reliable reference intervals (RI) is key to avoiding misdiagnoses. In 2011, IFCC published the new reference measurement procedure (RMP) for the determination of serum ALP in which one of the main modifications was the measuring temperature of the assay. Here, the new RMP was used to help establish RIs for serum ALP concentrations in healthy Chinese Han. METHODS: Volunteer individuals in Guangdong province, China (n=1622) were screened by questionnaire and laboratory testing for eligibility as a reference. Blood (20 mL) was collected and samples were measured by the Roche Modular system using the new RMP for the serum ALP compatible method. Partitioning of values by gender and/or age was evaluated with a standard normal deviate test after removing outliers. A simple non-parametric method for a two-sided 95% distribution of reference values was calculated. RESULTS: Serum ALP concentrations were obtained from the cohort of eligible reference individuals (n=658). The RI for serum ALP in males age 18-79 years was 48-131 U/L. Females were partitioned into two age groups based on statistical analysis, 18-49 years and 50-79 years, and the RIs derived were 40-106 U/L and 57-159 U/L, respectively. CONCLUSIONS: RIs for serum ALP for Chinese Han individuals in between the ages of 18 and 79 years were determined and required partitioning due to the higher ALP values of females age 50-79 years.


Asunto(s)
Fosfatasa Alcalina/sangre , Pruebas Enzimáticas Clínicas/normas , Adolescente , Adulto , Anciano , China , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Adulto Joven
18.
Clin Lab ; 62(10): 1941-1945, 2016 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-28164526

RESUMEN

BACKGROUND: A consensus on an accurate method to measure γ-glutamyltransferase (GGT) activity for clinical purposes has not been achieved among practicing clinical laboratories. To improve analytical trueness, we evaluated the influences of matrix effects in proficiency testing (PT) materials on the measurement of GGT activity in human serum samples. METHODS: Five fresh frozen human samples (FFS1-5) and five lyophilized proficiency testing materials (Lyo1-5) were distributed to 23 participating clinical laboratories for the measurement of GGT activity. Target GGT activity values for the samples were obtained by using previously approved reference methods. The results obtained by the Beckman Coulter Unicel DxC 800 Synchron analyzer were compared to the target values assigned by two reference laboratories, and the commutability of the lyophilized materials was evaluated according to Clinical and Laboratory Standards Institute (CLSI) guideline EP14-A2. RESULTS: The relative bias between the results obtained by the Beckman Coulter analyzer and the reference target values ranged from -27.2% to -18.0% for FFS1-5 and from 9.1% to 2.5% for Lyo1-5. Non-commutability of all lyophilized samples falling outside of the 95% prediction interval was observed. CONCLUSIONS: The results obtained for the lyophilized PT materials were deemed acceptable within the total allowable errors, suggesting that matrix effects may impart a false sense of confidence that clinical analytical systems are performing very well. A primary reference measurement procedure on fresh frozen serum provides a valuable method for evaluating the trueness of results measured by PT.


Asunto(s)
Ensayos de Aptitud de Laboratorios , gamma-Glutamiltransferasa/metabolismo , Sesgo , Humanos
19.
Clin Lab ; 61(5-6): 445-52, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26118174

RESUMEN

BACKGROUND: Alkaline phosphatase (ALP) is routinely analyzed in clinical laboratories for the comprehensive assessment of hepatic and osteal diseases. The official reference measurement procedure (RMP) of ALP was released by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) in 2011. However, most of the commercial kits still trace back to the old version (1983). There was a difference between the trace measurement procedure and the RMP. Therefore, the discrepancy among clinical systems and application of the new RMP for ALP in clinical laboratories was studied. METHODS: According to the recommendation of the IFCC, the RMP for ALP (2011) was reproduced. The reference measurement system (RMS) for serum ALP and 19 clinical systems were included in the external quality assessment (EQA). The relative bias was calculated between the clinical systems' results and RMS, as well as each clinical system and the average value of all clinical systems. The qualified rates (passing score in percentage) for the 19 clinical systems were compared by using two different standards. In the comparison experiment, two clinical systems were evaluated before and after calibration by RMP. The clinical acceptability at the medical decision point was evaluated. RESULTS: The performance of the reproduced RMP for ALP was: total imprecision was 0.33% and 0.42% at 336.9 U/L and 138.74 U/L, respectively. The accuracy was in the acceptable range. Excellent linearity was obtained for linear regression (R = 0.9998). In the EQA experiment, the relative bias of clinical systems and RMP ranged from -26.36% to 19.49%, and the majority of them had a negative value. Relative bias of clinical systems and the average value of 19 clinical systems ranged from -24.28% to 33.48%. The qualified rate for clinical systems was 53% - 89% evaluated by Standard 1 and was 95% - 100% evaluated by Standard 2. In the comparison experiment, the relative bias for the two clinical systems decreased and both of the clinical systems showed less relative bias at the medical decision points after calibration by RMP. CONCLUSIONS: There was a much higher discrepancy among clinical systems for the testing of serum ALP. Traceability and standardization would likely be improved for clinical systems by the application of RMP for ALP (2011) in clinical laboratories.


Asunto(s)
Fosfatasa Alcalina/sangre , Análisis Químico de la Sangre/normas , Humanos , Estándares de Referencia
20.
J Pharm Biomed Anal ; 250: 116396, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-39128283

RESUMEN

Critical events in Alzheimer's disease (AD) involve an imbalance between the production and clearance of amyloid-ß (Aß) peptides from the brain. The ratio of Aß42 to Aß40 in plasma was useful for evaluating AD, but quantification is limited by factors including preanalytical analyte loss and insufficient sensitivity. The availability of a targeted UPLC-MS/MS method with adequate analytical sensitivity and accurate values traceable to the SI units is essential for implementing a strategy for assay standardization. A targeted UPLC-MS/MS method for plasma Aß42 and Aß40 quantification was developed based on selected characteristic peptides spiked by 15N-labeled Aß. The calibrator was assigned using an amino acid analysis reference method trace to SI units. UPLC-MS/MS conditions and sample preparation procedures were assessed. 59 plasma samples comparison were used to evaluate immunoassays. Additionally, two clinical cohorts were selected for diagnostic performance evaluation. The LOQ of Aß42 and Aß40 is 10 pg mL-1 and 20 pg mL-1, respectively. The linear range was 10-500 pg mL-1 for Aß42 and 20-1000 pg mL-1 for Aß40, recoveries between 95.3 % and 108.2 % for Aß42, 93.2 % and 104.1 % for Aß40, imprecisions were <7 %. The accuracy of method was validated by analysis of a certified reference material. Clinical cohorts for diagnostic performance evaluation shown that the area under the curve (AUC) for plasma Aß42 and Aß42/Aß40 to differentiate between AD and CN were 0.767 and 0.799, respectively. A robust UPLC-MS/MS method was developed and demonstrated that suitable for a wide range of plasma Aß42 and Aß40. Applied to the investigation of clinically discrepant results, this method can act as an arbiter of the concentration of plasma Aß42 and Aß40 present.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Fragmentos de Péptidos , Espectrometría de Masas en Tándem , Humanos , Péptidos beta-Amiloides/sangre , Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/diagnóstico , Espectrometría de Masas en Tándem/métodos , Fragmentos de Péptidos/sangre , Cromatografía Líquida de Alta Presión/métodos , Anciano , Masculino , Femenino , Reproducibilidad de los Resultados , Biomarcadores/sangre , Calibración , Anciano de 80 o más Años , Cromatografía Líquida con Espectrometría de Masas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA