Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
J Biomed Mater Res A ; 66(1): 29-37, 2003 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-12833428

RESUMEN

Cyclic mechanical strain has been demonstrated to enhance the development and function of engineered smooth muscle (SM) tissues, and it would be necessary for the development of the elastic scaffolds if one wishes to engineer SM tissues under cyclic mechanical loading. This study reports on the development of an elastic scaffold fabricated from a biodegradable polymer. Biodegradable poly(glycolide-co-caprolactone) (PGCL) copolymer was synthesized from glycolide and epsilon-caprolactone in the presence of stannous octoate as catalyst. The copolymer was characterized by (1)H-NMR, gel permeation chromatography and differential scanning calorimetry. Scaffolds for tissue engineering applications were fabricated from PGCL copolymer using the solvent-casting and particle-leaching technique. The PGCL scaffolds produced in this fashion had open pore structures (average pore size = 250 microm) without the usual nonporous skin layer on external surfaces. Mechanical testing revealed that PGCL scaffolds were far more elastic than poly(lactic-co-glycolic acid) (PLGA) scaffolds fabricated using the same method. Tensile mechanical tests indicated that PGCL scaffolds could withstand an extension of 250% without cracking, which was much higher than withstood by PLGA scaffolds (10-15%). In addition, PGCL scaffolds achieved recoveries exceeding 96% at applied extensions of up to 230%, whereas PLGA scaffolds failed (cracked) at an applied strain of 20%. Dynamic mechanical tests showed that the permanent deformation of the PGCL scaffolds in a dry condition produced was less than 4% of the applied strain, when an elongation of 20% at a frequency of 1 Hz (1 cycle per second) was applied for 6 days. Moreover, PGCL scaffolds in a buffer solution also had permanent deformations less than 5% of the applied strain when an elongation of 10% at a frequency of 1 Hz was applied for 2 days. The usefulness of the PGCL scaffolds was demonstrated by engineering SM tissues in vivo. This study shows that the elastic PGCL scaffolds produced in this study could be used to engineer SM-containing tissues (e.g. blood vessels and bladders) in mechanically dynamic environments.


Asunto(s)
Implantes Absorbibles , Materiales Biocompatibles/química , Glicósidos/química , Lactonas/química , Ingeniería de Tejidos/instrumentación , Animales , Células Cultivadas/trasplante , Elasticidad , Glicósidos/síntesis química , Ácido Láctico/química , Lactonas/síntesis química , Masculino , Ensayo de Materiales , Ratones , Ratones Desnudos , Microscopía Electrónica de Rastreo , Músculo Liso Vascular/citología , Resonancia Magnética Nuclear Biomolecular , Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Polímeros/química , Ratas , Ratas Sprague-Dawley , Estrés Mecánico , Resistencia a la Tracción , Trasplante Heterólogo
2.
Adv Mater ; 26(18): 2894-900, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24504558

RESUMEN

Novel acrylamide-based hard-soft hybrid block copolymers generate high-quality nanolithographic patterns satisfying high-resolution, long-range ordering, low defect density, moderate etch selectivity, and easy pattern transfer onto a substrate. The resulting patterns can also be used as a scaffold for metallic nanostructures such as aligned nanowires and nanomeshes with extraordinary structural regularity.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA