Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Anal Chem ; 94(13): 5248-5254, 2022 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-35312291

RESUMEN

High-resolution scanning electrochemical cell microscopy (SECCM), synchronously visualizing the topography and electrochemical activity, could be used to directly correlate the structure and activity of materials nanoscopically. However, its topographical measurement is largely restricted by the size and stability of the meniscus droplet formed at the end of the nanopipette. In this paper, we report a scheme that could reliably gain several tens nanometer resolution (≥65 nm) of SECCM using homemade ∼50 nm inner diameter probes. Furthermore, the topography and hydrogen evolution reaction (HER) activity of ∼45 nm self-assembled Au nanoparticles monolayer were simultaneously recorded successfully. This scheme could make mapping of both topologic and chemical properties of samples in the nanometer regime with SECCM routinely, which potentially can largely expand the field of SECCM applications.


Asunto(s)
Oro , Nanopartículas del Metal , Oro/química , Hidrógeno , Microscopía , Microscopía Electroquímica de Rastreo
2.
Opt Express ; 30(9): 14651-14660, 2022 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-35473204

RESUMEN

Subwavelength chiral metamaterials with tunable geometries and compositions are essential to advance the development of chiral biochemical samples detection. Here, we report a spatial symmetry breaking chiral terahertz (THz) metamaterial structure with stacked layers of L-shape arranged gold disks as the periodic unit cell. The chiroptical response can be adjusted on-demand by manipulating the number of stacking layers and the twisted angle of the periodic unit between adjacent array layers. We reveal that the chiroptical response originates from the optical resonances of the gold disks and the adjacent gold disks array layers via experiments and numerical simulation analysis. Furthermore, we find that this chiral metamaterial can realize label-free detection of proline in biological samples and label-free enantio-discrimination of chiral molecules. The change of the analyte concentration can also regulate the transmission circular dichroism (TCD) intensity of the chiral metamaterials. Our results not only provide new ideas into the design of functional chiral metamaterials, but also bring new strategies to develop chiroptical biosensing devices.


Asunto(s)
Oro , Dicroismo Circular , Simulación por Computador , Estereoisomerismo
3.
Opt Lett ; 47(23): 6101-6104, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37219182

RESUMEN

An all-nonmetal metamaterial (ANM) terahertz device with a silicon bowtie structure has been developed, which has comparable efficiency to that of its metallic counterparts, and better compatibility with modern semiconductor fabrication processes. Moreover, a highly tunable ANM with the same structure was successfully fabricated through integration with a flexible substrate, which demonstrated large tunability over a wide frequency range. Such a device can be used in terahertz systems for numerous applications, and is a promising substitute for conventional metal-based structures.

4.
Biosens Bioelectron ; 100: 23-27, 2018 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-28850824

RESUMEN

We report on the design and fabrication of a hybrid sensor that integrates transmission-mode localized surface plasmonic resonance (LSPR) into a quartz crystal microbalance (QCM) for studying biochemical surface reactions. The coupling of LSPR nanostructures and a QCM allows optical spectra and QCM resonant frequency shifts to be recorded simultaneously and analyzed in real time for a given surface adsorption process. This integration simplifies the conventional combination of SPR and QCM and has the potential to be miniaturized for application in point-of-care (POC) diagnostics. The influence of antibody-antigen recognition effect on both the QCM and LSPR has been analyzed and discussed.


Asunto(s)
Anticuerpos Inmovilizados/química , Inmunoglobulina G/análisis , Tecnicas de Microbalanza del Cristal de Cuarzo/instrumentación , Resonancia por Plasmón de Superficie/instrumentación , Adsorción , Animales , Diseño de Equipo , Inmunoensayo/instrumentación , Nanoestructuras/química , Sistemas de Atención de Punto , Conejos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA