Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Front Neurol ; 13: 755492, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35359626

RESUMEN

Background: Computed tomography (CT) plays an essential role in classifying stroke, quantifying penumbra size and supporting stroke-relevant radiomics studies. However, it is difficult to acquire standard, accurate and repeatable images during follow-up. Therefore, we invented an intelligent CT to evaluate stroke during the entire follow-up. Methods: We deployed a region proposal network (RPN) and V-Net to endow traditional CT with intelligence. Specifically, facial detection was accomplished by identifying adjacent jaw positions through training and testing an RPN on 76,382 human faces using a preinstalled 2-dimensional camera; two regions of interest (ROIs) were segmented by V-Net on another training set with 295 subjects, and the moving distance of scanning couch was calculated based on a pre-generated calibration table. Multiple cohorts including 1,124 patients were used for performance validation under three clinical scenarios. Results: Cranial Automatic Planbox Imaging Towards AmeLiorating neuroscience (CAPITAL)-CT was invented. RPN model had an error distance of 4.46 ± 0.02 pixels with a success rate of 98.7% in the training set and 100% with 2.23 ± 0.10 pixels in the testing set. V-Net-derived segmentation maintained a clinically tolerable distance error, within 3 mm on average, and all lines presented with a tolerable angle error, within 3° on average in all boundaries. Real-time, accurate, and repeatable automatic scanning was accomplished with and a lower radiation exposure dose (all P < 0.001). Conclusions: CAPITAL-CT generated standard and reproducible images that could simplify the work of radiologists, which would be of great help in the follow-up of stroke patients and in multifield research in neuroscience.

3.
EBioMedicine ; 54: 102724, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32251997

RESUMEN

BACKGROUND: Interstitial lung disease requires frequent re-examination, which directly causes excessive cumulative radiation exposure. To date, AI has not been applied to CT for enhancing clinical care; thus, we hypothesize AI may empower CT with intelligence to realize automatic and accurate pulmonary scanning, thus dramatically decrease medical radiation exposure without compromising patient care. METHODS: Facial boundary detection was realized by recognizing adjacent jaw position through training and testing a region proposal network (RPN) on 76,882 human faces using a preinstalled 2-dimensional camera; the lung-fields was then segmented by V-Net on another training set with 314 subjects and calculated the moving distance of the scanning couch based on a pre-generated calibration table. A multi-cohort study, including 1,186 patients was used for validation and radiation dose quantification under three clinical scenarios. FINDINGS: A U-HAPPY (United imaging Human Automatic Planbox for PulmonarY) scanning CT was designed. Error distance of RPN was 4·46±0·02 pixels with a success rate of 98·7% in training set and 2·23±0·10 pixels with 100% success rate in testing set. Average Dice's coefficient was 0·99 in training set and 0·96 in testing set. A calibration table with 1,344,000 matches was generated to support the linkage between camera and scanner. This real-time automation makes an accurate plan-box to cover exact location and area needed to scan, thus reducing amounts of radiation exposures significantly (all, P<0·001). INTERPRETATION: U-HAPPY CT designed for pulmonary imaging acquisition standardization is promising for reducing patient risk and optimizing public health expenditures. FUNDING: The National Natural Science Foundation of China.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Aprendizaje Automático , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Masculino , Persona de Mediana Edad , Modelación Específica para el Paciente , Exposición a la Radiación , Tomografía Computarizada por Rayos X/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA