Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Pancreatology ; 24(6): 954-959, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39043488

RESUMEN

BACKGROUND: Chronic pancreatitis (CP) is characterized by debilitating pain which affects patients' quality of life. Early surgical intervention has been shown to mitigate pain and prevent a decline in quality of life. The present study evaluated the impact of bile duct and duodenum preserving pancreatic head resection (BDPPHR), an innovative technique, on pain relief, functional outcomes, postoperative morbidity, and mortality in patients with CP. METHODS: Between March 2019 and July 2022, a total of 37 patients underwent bile duct and duodenum preserving pancreatic head resection (BDPPHR) for pain relief in patients with CP. Post-operative outcomes were assessed by Izbicki pain score, exocrine insufficiency, endocrine insufficiency, and return to work. The safety of the surgical procedure was determined by evaluation of postoperative morbidity and mortality as per Clavien-Dindo scores. RESULTS: BDPPHR showed a significant reduction in Izbicki pain scores with 30 (81 %) patients experiencing complete or partial pain relief up to 18 months of follow up. 32(86 %) patients ceased narcotic use by the end of the 18-month follow-up period. 33 (89 %) patients were able to resume regular work at the end of 18 months. There were no significant alterations in both exocrine and endocrine statuses post-surgery. The median duration of hospital stay was 4.5 days (3-11). Major complications occurred in 2 (5 %) patients. There was no post-operative mortality. CONCLUSION: BDPPHR is a novel and safe technique of near total head resection which results in very good pain relief in 81 % of patients.


Asunto(s)
Pancreatectomía , Pancreatitis Crónica , Humanos , Pancreatitis Crónica/cirugía , Pancreatitis Crónica/complicaciones , Masculino , Femenino , Persona de Mediana Edad , Adulto , Pancreatectomía/métodos , Resultado del Tratamiento , Anciano , Páncreas/cirugía , Calidad de Vida , Complicaciones Posoperatorias/epidemiología , Conductos Biliares/cirugía , Duodeno/cirugía
2.
Phys Chem Chem Phys ; 26(17): 13316-13326, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38639914

RESUMEN

In this article we present a quantitative analysis of the second positive system of molecular nitrogen and the first negative system of the molecular nitrogen cation excited in the presence of ionizing radiation. Optical emission spectra of atmospheric air and nitrogen surrounding 210Po sources were measured from 250 to 400 nm. Multi-Boltzmann and non-Boltzmann vibrational distribution spectral models were used to determine the vibrational temperature and vibrational distribution function of the emitting N2(C3Πu) and N2+(B2Σ+u) states. A zero-dimensional kinetic model, based on the electron energy distribution function (EEDF) and steady-state excitation and de-excitation of N2(X1Σ+g), N2+(B2Σ+u), N2+(X2Σ+g), N4+, O2+, and N2(C3Πu, v), was developed for the prediction of the relative spectral intensity of both the N2+(B2Σ+u → X2Σ+g) emission band and the vibrational bands of N2(C3Πu → B3Πg) for comparison with the experimental data.

3.
Opt Express ; 29(4): 4936-4946, 2021 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-33726039

RESUMEN

Laser-induced breakdown spectroscopy is a promising method for rapidly measuring hydrogen and its isotopes, critical to a wide range of disciplines (e.g. nuclear energy, hydrogen storage). However, line broadening can hinder the ability to detect finely spaced isotopic shifts. Here, the effects of varying plasma generation conditions (nanosecond versus femtosecond laser ablation) and ambient environments (argon versus helium gas) on spectral features generated from Zircaloy-4 targets with varying hydrogen isotopic compositions were studied. Time-resolved 2D spectral imaging was employed to detail the spatial distribution of species throughout plasma evolution. Results highlight that hydrogen and deuterium isotopic shifts can be measured with minimal spectral broadening in a ∼ 10 Torr helium gas environment using ultrafast laser-produced plasmas.

4.
Pancreatology ; 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39332978
5.
Phys Chem Chem Phys ; 21(29): 16161-16169, 2019 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-31294428

RESUMEN

We investigate the oxidation of uranium (U) species, the physical conditions leading to uranium monoxide (UO) formation and the interplay between plume hydrodynamics and plasma chemistry in a laser-produced U plasma. Plasmas are produced by ablation of metallic U using nanosecond laser pulses. An ambient gas environment with varying oxygen partial pressures in 100 Torr inert Ar gas is used for controlling the plasma oxidation chemistry. Optical emission spectroscopic analysis of U atomic and monoxide species shows a reduction in the emission intensity and persistence with increasing oxygen partial pressure. Spectral modelling is used for identifying the physical conditions in the plasma that favor UO formation. The optimal temperature for UO formation is found to be in the temperature range of ∼1500-5000 K. The spectrally integrated and spectrally filtered (monochromatic) imaging of U atomic and molecular species reveals the evolutionary paths of various species in the plasma. Our results also highlight that oxidation in U plasmas predominantly occurs at the cooler periphery and is delayed with respect to plasma formation, and the dissipation of molecular species strongly depends on oxygen partial pressure.

6.
Opt Lett ; 43(5): 1055-1058, 2018 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-29489779

RESUMEN

We report the use of laser-induced fluorescence (LIF) of laser ablation (LA) plumes for standoff applications. The standoff analysis of Al, as major and minor species in samples, is performed in a nanosecond laser-produced plasma created at a distance of ∼10 m. The LIF of LA plumes is carried out by resonantly exciting an Al transition at 394.4 nm (S1/22-P1/22) using a continuous wave (cw) tunable laser and by collecting the direct-line fluorescence signal at 396.15 nm. The spectral resolution of LIF is obtained by scanning the cw tunable LIF laser across the selected Al transition. Our results highlight that LIF provides enhanced signal intensity, emission persistence, and spectral resolution when compared to thermally excited emission.

7.
Opt Lett ; 43(20): 5118-5121, 2018 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-30320834

RESUMEN

We use a spatially and temporally resolved emission tracking technique based on optical emission spectroscopy to map the evolution of emission features from uranium and its compounds in a plasma produced by a nanosecond laser. We observe quenching of the emission from neutral uranium (591.538 nm) and uranium monoxide (593.55 nm) species with increasing oxygen concentration and discuss possible reaction pathways for dissociation or formation of higher uranium oxides (UxOy). We further identify spectral features between 320 nm and 380 nm and between 520 nm and 640 nm, which we attribute to UxOy.

8.
Opt Express ; 25(3): 2312-2326, 2017 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-29519078

RESUMEN

We report laser-induced fluorescence spectroscopy (LIF) of laser-produced plasmas under varying nitrogen pressure levels up to atmospheric pressure. The plasmas were generated on a glass target containing minor amounts of U and Al using 1064 nm, 6 ns pulses from a Nd:YAG laser. A frequency-doubled continuous-wave Ti:Sapphire laser was used as an ultra-narrowband tunable LIF excitation source to increase the magnitude and persistence of emission from selected U and Al atomic transitions in a laser-produced plasma. 2D-fluorescence spectroscopy (2D-FS) absorption/emission images were recorded at various nitrogen pressure levels, showing both excitation and emission spectral features. At lower pressure levels (⪝100 Torr), fluorescence emission was found to be well separated in time from thermally-excited emission. However, as the ambient pressure increased, the thermally-excited emission persisted for longer times along with a reduction of LIF emission persistence and intensity. The excitation spectral features showed the inherent linewidths of various transitions in the plasma, which have significantly narrower spectral linewidths than observed in emission spectra. We evaluated two nearby transitions separated by only 18 pm to demonstrate the effectiveness of fluorescence spectra over thermally-excited spectra for high-resolution studies. The present results highlight the importance of LIF as a diagnostic tool employing continuous-wave laser re-excitation, addressing some of the limitations of traditional emission and absorption spectroscopic methods.

9.
Opt Express ; 24(16): 17941-9, 2016 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-27505761

RESUMEN

The combination of femtosecond laser filament ablation and emission spectroscopy is a potential analytical tool for standoff characterization of samples of interest. We compare the emission features and physical conditions of plasmas generated from metal targets using either by loosely focused femtosecond filaments or by lens-free filaments. Our results show that the filament generation conditions influence the plasma properties appreciably which include the atomic and molecular emission features, persistence and plasma fundamentals (temperature and density). The loosely focused fs pulse filaments are found to generate ablation plumes with higher temperature and density along with increased persistence compared to plumes generated by lens-free filaments.

10.
Opt Lett ; 41(15): 3547-50, 2016 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-27472615

RESUMEN

We use a two-dimensional laser-induced fluorescence spectroscopy technique to measure the coupled absorption and emission properties of atomic species in plasmas produced via laser ablation of a solid aluminum target at atmospheric pressure. Emission spectra from the Al I 394.4 nm and Al I 396.15 nm transitions are measured while a frequency-doubled, continuous wave (cw) Ti:sapphire laser is tuned across the Al I 396.15 nm transition. The resulting two-dimensional spectra show the energy coupling between the two transitions via increased emission intensity for both transitions during resonant absorption of the cw laser at one transition. Time-delayed, gated detection of the emission spectrum is used to isolate resonantly excited fluorescence emission from thermally excited emission from the plasma. In addition, the tunable cw laser measures the absorption spectrum of the Al transition with ultrahigh resolution after the plasma has cooled, resulting in narrower spectral linewidths than observed in emission spectra. Our results highlight that fluorescence spectroscopy employing cw laser re-excitation after pulsed laser ablation combines benefits of both traditional emission and absorption spectroscopic methods.

11.
Opt Express ; 23(21): 27113-22, 2015 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-26480372

RESUMEN

Ultrafast laser filament induced breakdown spectroscopy is a very promising method for remote material detection. We present characteristics of plasmas generated in a metal target by laser filaments in air. Our measurements show that the temperature of the ablation plasma is clamped along the filament channel due to intensity clamping in a filament. Nevertheless, significant changes in radiation intensity are noticeable, and this is essentially due to variation in the number density of emitting atoms. The present results also explain the near absence of ion emission but strong atomic neutral emission from plumes produced during fs LIBS in air.

12.
Opt Express ; 23(12): 15608-15, 2015 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-26193540

RESUMEN

We investigated the role of spot size on plume morphology during ultrafast laser ablation of metal targets. Our results show that the spatial features of fs LA plumes are strongly dependent on the focal spot size. Two-dimensional self-emission images showed that the shape of the ultrafast laser ablation plumes changes from spherical to cylindrical with an increasing spot size from 100 to 600 µm. The changes in plume morphology and internal structures are related to ion emission dynamics from the plasma, where broader angular ion distribution and faster ions are noticed for the smallest spot size used. The present results clearly show that the morphological changes in the plume with spot size are independent of laser pulse width.

13.
Anal Bioanal Chem ; 400(10): 3239-46, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21359572

RESUMEN

Planar slabs of pure Li were irradiated with 1.064 nm, 6 ns Nd:YAG laser pulses. Determination of plasma densities at both the earliest times of plasma formation and near the target surface was performed using Nomarski interferometry. The plasma parameters at later times were evaluated using optical emission spectroscopy. The space- and time-dependent electron densities and temperatures of the plasma were determined from their Stark broadening and the relative intensities of the spectral lines, respectively. The advantages and disadvantages of both of these techniques are evaluated and discussed.

14.
S Afr J Surg ; 59(4): 149-152, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34889537

RESUMEN

BACKGROUND: Laparoscopic inguinal hernia repair is routine in many paediatric centres. One of several techniques described in 2006 is the laparoscopic percutaneous internal ring suturing (PIRS) technique. This technique which is not widely used in South Africa has been adopted for paediatric inguinal hernias at our institution, and this is a review of the experience. METHOD: The study is a retrospective review of the patients who underwent PIRS (a single port combined percutaneous procedure used to close the internal ring) at our hospital from October 2018 until March 2020. We describe the technique in our setting and review our cohort of patients, demographics, clinical presentation, operative duration and complications. RESULTS: One hundred and ten laparoscopic PIRS procedures were performed on 94 patients; 15 had bilateral inguinal hernias. Polydioxanone and Prolene were the sutures used for the procedures. Average operative time was 12 minutes for unilateral hernias and 33 minutes for bilateral hernias. All operations were completed laparoscopically. Follow-up was for a minimum of three months, but up to 21 months. Complications included three intraoperative haematomas, three hydrocoeles and two umbilical granulomas postoperatively. There were two recurrent hernias of which one was managed with redo PIRS; the other required open herniotomy for an irreducible obstructed hernia. CONCLUSION: This review is supportive evidence that the PIRS technique for managing paediatric inguinal hernias in a tertiary institution in South Africa can be performed safely with few complications.


Asunto(s)
Hernia Inguinal , Laparoscopía , Niño , Hernia Inguinal/cirugía , Herniorrafia , Humanos , Recurrencia , Estudios Retrospectivos , Suturas , Resultado del Tratamiento
15.
Phys Rev E ; 103(1-1): 013213, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33601577

RESUMEN

Time-resolved tunable laser absorption spectroscopy is used to characterize the physical properties of ultrafast laser-produced plasmas. The plasmas were produced from an Inconel target, with ≤0.4wt% Al, using ∼35fs, ∼800nm, ∼5mJ laser pulses at varying Ar background pressures from 1 to 100 Torr. The absorption spectrum of atomic Al is measured with high spectral and temporal resolution when the probe laser is stepped across the selected Al transition at 394.4 nm. Spectral fitting is used to infer linewidths, kinetic temperature, Al column density, and pressure broadening coefficient. The late time physical properties of plasmas are compared for various pressure levels. Our studies highlight that a significant lower state population exists even at early times of ultrafast laser-produced plasma evolution, and lower state population persistence decreases with increasing ambient pressure. We also show that the fundamental optical properties, such as pressure broadening, can be measured using ultrafast laser-produced plasmas combined with laser absorption spectroscopy.

16.
Rev Sci Instrum ; 78(11): 113105, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18052463

RESUMEN

The Interaction of Materials with Particles and Components Testing (IMPACT) experimental facility is furnished with multiple ion sources and in situ diagnostics to study the modification of surfaces undergoing physical, chemical, and electronic changes during exposure to energetic particle beams. Ion beams with energies in the range between 20 and 5000 eV can bombard samples at flux levels in the range of 10(10)-10(15) cm(-2) s(-1); parameters such as ion angle of incidence and exposed area are also controllable during the experiment. IMPACT has diagnostics that allow full characterization of the beam, including a Faraday cup, a beam imaging system, and a retarding field energy analyzer. IMPACT is equipped with multiple diagnostics, such as electron (Auger, photoelectron) and ion scattering spectroscopies that allow different probing depths of the sample to monitor compositional changes in multicomponent and/or layered targets. A unique real-time erosion diagnostic based on a dual quartz crystal microbalance measures deposition from an eroding surface with rates smaller than 0.01 nm/s, which can be converted to a sputter yield measurement. The monitoring crystal can be rotated and placed in the target position so that the deposited material on the quartz crystal oscillator surface can be characterized without transfer outside of the vacuum chamber.

17.
Appl Spectrosc ; 58(6): 719-26, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18171514

RESUMEN

The energy absorption and laser propagation characteristics of air and argon sparks at one atmosphere have been investigated. To create the sparks, 532 nm pulses from a frequency doubled Q-switched Nd : YAG laser are used. We employed 2 ns gated fast photography for studying the time evolution of the kernel at early times. Optical emission spectroscopy is used to infer temperature and density of the sparks. Significant energy absorption by the plasma is observed just above the breakdown threshold. The energy absorption and propagation in the spark indicated that argon plasma is more absorptive than air plasma. The absorption of the spark increases with laser energy, and at higher energies absorption saturation is observed. A spiky behavior is observed in the transmitted temporal profiles of lasers at higher energies and this is explained as due to the formation of a self-regulating regime.

18.
Phys Rev E Stat Nonlin Soft Matter Phys ; 69(2 Pt 2): 026413, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-14995572

RESUMEN

The dynamics and confinement of laser-created plumes expanding across a transverse magnetic field have been investigated. 1.06 microm, 8 ns pulses from a neodymium-doped yttrium aluminum garnet laser were used to create an aluminum plasma which was allowed to expand across a 0.64 T magnetic field. Fast photography, emission spectroscopy, and time of flight spectroscopy were used as diagnostic tools. Changes in plume structure and dynamics, enhanced emission and ionization, and velocity enhancement were observed in the presence of the magnetic field. Photographic studies showed that the plume is not fully stopped and diffuses across the field. The temperature of the plume was found to increase due to Joule heating and adiabatic compression. The time of flight studies showed that all of the species are slowed down significantly. A multiple peak temporal distribution was observed for neutral species.

19.
Anal Sci ; 17(1): 141-4, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11993651

RESUMEN

A dual-beam transient thermal-lens technique was employed for the determination of absolute fluorescence quantum-yield measurements of Rhodamine B laser dye in different solvents. We investigated the effect of excitation on the absolute fluorescence quantum yield of Rhodamine B. 514 nm radiation from an argon ion laser was used as a cw excitation source and 532 nm pulses from a Q-switched Nd:YAG laser were used as a pulsed excitation source. The fluorescence quantum-yield values were found to be strongly influenced by environmental effects as well as the transient nature of the excitation beam. Our results also indicate that parameters, like the concentration of the dye solution, aggregate formation and excited state absorption, affect the absolute values of the fluorescence yield significantly.

20.
Sci Rep ; 4: 6845, 2014 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-25366885

RESUMEN

Tungsten has been chosen as the main candidate for plasma facing components (PFCs) due to its superior properties under extreme operating conditions in future nuclear fusion reactors such as ITER. One of the serious issues for PFCs is the high heat load during transient events such as ELMs and disruption in the reactor. Recrystallization and grain size growth in PFC materials caused by transients are undesirable changes in the material, since the isotropic microstructure developed after recrystallization exhibits a higher ductile-to-brittle transition temperature which increases with the grain size, a lower thermal shock fatigue resistance, a lower mechanical strength, and an increased surface roughening. The current work was focused on careful determination of the threshold parameters for surface recrystallization, grain growth rate, and thermal shock fatigue resistance under ELM-like transient heat events. Transient heat loads were simulated using long pulse laser beams for two different grades of ultrafine-grained tungsten. It was observed that cold rolled tungsten demonstrated better power handling capabilities and higher thermal stress fatigue resistance compared to severely deformed tungsten. Higher recrystallization threshold, slower grain growth, and lower degree of surface roughening were observed in the cold rolled tungsten.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA