Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Magn Reson Med ; 74(1): 106-114, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25081734

RESUMEN

PURPOSE: An external driver-free MRI method for assessment of liver fibrosis offers a promising noninvasive tool for diagnosis and monitoring of liver disease. Lately, the heart's intrinsic motion and MR tagging have been utilized for the quantification of liver strain. However, MR tagging requires multiple breath-hold acquisitions and substantial postprocessing. In this study, we propose the use of a fast strain-encoded (FSENC) MRI method to measure the peak strain (Sp ) in the liver's left lobe, which is in close proximity and caudal to the heart. Additionally, we introduce a new method of measuring heart-induced shear wave velocity (SWV) inside the liver. METHODS: Phantom and in vivo experiments (11 healthy subjects and 11 patients with liver fibrosis) were conducted. Reproducibility experiments were performed in seven healthy subjects. RESULTS: Peak liver strain, Sp , decreased significantly in fibrotic liver compared with healthy liver (6.46% ± 2.27% vs 12.49% ± 1.76%; P < 0.05). Heart-induced SWV increased significantly in patients compared with healthy subjects (0.15 ± 0.04 m/s vs 0.63 ± 0.32 m/s; P < 0.05). Reproducibility analysis yielded no significant difference in Sp (P = 0.47) or SWV (P = 0.56). CONCLUSION: Accelerated external driver-free noninvasive assessment of left liver lobe strain and SWV is feasible using strain-encoded MRI. The two measures significantly separate healthy subjects from patients with fibrotic liver. Magn Reson Med 74:106-114, 2015. © 2014 Wiley Periodicals, Inc.

2.
Radiology ; 266(1): 114-22, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23151825

RESUMEN

PURPOSE: To determine whether chronic pulmonary arterial pressure (PAP) elevation affects regional biventricular function and whether regional myocardial function may be reduced in pulmonary arterial hypertension (PAH) patients with preserved global right ventricular (RV) function. MATERIALS AND METHODS: After informed consent, 35 PAH patients were evaluated with right heart catheterization and cardiac magnetic resonance (MR) imaging and compared with 13 healthy control subjects. Biventricular segmental, section, and mean ventricular peak systolic longitudinal strain (E(LL)), as well as left ventricular (LV) circumferential and RV tangential strains were compared between PAH patients and control subjects and correlated with global function and catheterization of the right heart indexes. Spearman ρ correlation with Bonferroni correction was used. Multiple linear regression analysis was performed to determine predictors for regional myocardial function. RESULTS: In the RV of PAH patients, longitudinal contractility was reduced at the basal, mid, and apical levels, and tangential contractility was reduced at the midventricular level. Mean RV E(LL) positively correlated with mean PAP (r = 0.62, P < .0014) and pulmonary vascular resistance index (PVRI) (r = 0.77, P < .0014). Mean PAP was a predictor of mean RV E(LL) (ß = .19, P = .005) in a multiple linear regression analysis. In the LV, reduced LV longitudinal and circumferential contractility were noted at the base. LV anteroseptal E(LL) positively correlated with increased mean PAP (r = 0.5, P = .03) and septal eccentricity index (r = 0.5, P = .01). In a subgroup of PAH patients with normal global RV function, significantly reduced RV longitudinal contractility was noted at basal and mid anterior septal insertions, as well as the mid anterior RV wall (P < .05 for all). CONCLUSION: In PAH patients, reduced biventricular regional function is associated with increased RV afterload (mean PAP and PVRI). Cardiac MR imaging helps identify regional RV dysfunction in PAH patients with normal global RV function. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12111599/-/DC1.


Asunto(s)
Hipertensión Pulmonar/complicaciones , Hipertensión Pulmonar/diagnóstico , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Disfunción Ventricular/diagnóstico , Disfunción Ventricular/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
J Cardiovasc Magn Reson ; 15: 37, 2013 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-23663535

RESUMEN

BACKGROUND: The aim of this study is to determine the test-retest reliability of the measurement of regional myocardial function by cardiovascular magnetic resonance (CMR) tagging using spatial modulation of magnetization. METHODS: Twenty-five participants underwent CMR tagging twice over 12 ± 7 days. To assess the role of slice orientation on strain measurement, two healthy volunteers had a first exam, followed by image acquisition repeated with slices rotated ±15 degrees out of true short axis, followed by a second exam in the true short axis plane. To assess the role of slice location, two healthy volunteers had whole heart tagging. The harmonic phase (HARP) method was used to analyze the tagged images. Peak midwall circumferential strain (Ecc), radial strain (Err), Lambda 1, Lambda 2, and Angle α were determined in basal, mid and apical slices. LV torsion, systolic and early diastolic circumferential strain and torsion rates were also determined. RESULTS: LV Ecc and torsion had excellent intra-, interobserver, and inter-study intra-class correlation coefficients (ICC range, 0.7 to 0.9). Err, Lambda 1, Lambda 2 and angle had excellent intra- and interobserver ICC than inter-study ICC. Angle had least inter-study reproducibility. Torsion rates had superior intra-, interobserver, and inter-study reproducibility to strain rates. The measurements of LV Ecc were comparable in all three slices with different short axis orientations (standard deviation of mean Ecc was 0.09, 0.18 and 0.16 at basal, mid and apical slices, respectively). The mean difference in LV Ecc between slices was more pronounced in most of the basal slices compared to the rest of the heart. CONCLUSIONS: Intraobserver and interobserver reproducibility of all strain and torsion parameters was excellent. Inter-study reproducibility of CMR tagging by SPAMM varied between different parameters as described in the results above and was superior for Ecc and LV torsion. The variation in LV Ecc measurement due to altered slice orientation is negligible compared to the variation due to slice location. TRIAL REGISTRATION: This trial is registered as NCT00005487 at National Heart, Lung and Blood institute.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Imagen por Resonancia Magnética , Contracción Miocárdica , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Enfermedades Cardiovasculares/etnología , Enfermedades Cardiovasculares/fisiopatología , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Estrés Mecánico , Factores de Tiempo , Torsión Mecánica , Estados Unidos/epidemiología
4.
Med Image Comput Comput Assist Interv ; 14(Pt 1): 444-51, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22003648

RESUMEN

Breast cancer is the most common cancer among women and the second highest cause of cancer-related death. Diagnostic magnetic resonance imaging (MRI) is recommended to screen high-risk patients. Strain-Encoded (SENC) can improve MRI's specificity by detecting and differentiating masses according to their stiffness. Previous phantom and ex-vivo studies have utilized SENC to detect cancerous masses. However, SENC required a 30% compression of the tissue, which may not be feasible for in-vivo imaging. In this work, we use finite element method simulations and phantom experiments to determine the minimum compression required to detect and classify masses. Results show that SENC is capable of detecting stiff masses at compression level of 7%, though higher compression is needed in order to differentiate between normal tissue and benign or malignant masses. With on-line SENC calculations implemented on the scanner console, we propose to start with small compressions for maximum patient comfort, then progress to larger compressions if any masses are detected.


Asunto(s)
Mama/patología , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Algoritmos , Simulación por Computador , Diseño de Equipo , Femenino , Análisis de Elementos Finitos , Humanos , Modelos Biológicos , Fantasmas de Imagen , Distribución de Poisson , Estrés Mecánico
5.
Acad Radiol ; 18(6): 705-15, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21440464

RESUMEN

RATIONALE AND OBJECTIVES: Early detection of breast lesions using mammography has resulted in lower mortality rates. However, some breast lesions are mammography occult, and magnetic resonance imaging (MRI) is recommended, but it has lower specificity. It is possible to achieve higher specificity by using strain-encoded (SENC) MRI and/or magnetic resonance elastography. SENC breast MRI can measure the strain properties of breast tissue. Similarly, magnetic resonance elastography is used to measure the elasticity (ie, shear stiffness) of different tissue compositions interrogating the tissue mechanical properties. Reports have shown that malignant tumors are three to 13 times stiffer than normal tissue and benign tumors. MATERIALS AND METHODS: The investigators have developed a SENC breast hardware device capable of periodically compressing the breast, thus allowing for longer scanning time and measuring the strain characteristics of breast tissue. This hardware enables the use of SENC MRI with high spatial resolution (1 × 1 × 5 mm(3)) instead of fast SENC imaging. Simple controls and multiple safety measures were added to ensure accurate, repeatable, and safe in vivo experiments. RESULTS: Phantom experiments showed that SENC breast MRI has higher signal-to-noise ratio and contrast-to-noise ratio than fast SENC imaging under different scanning resolutions. Finally, the SENC breast device reproducibility measurements resulted in a difference of <1 mm with a 1% strain difference. CONCLUSIONS: SENC breast magnetic resonance images have higher signal-to-noise ratio and contrast-to-noise ratios than fast SENC images. Thus, combining SENC breast strain measurements with diagnostic breast MRI to differentiate benign from malignant lesions could potentially increase the specificity of diagnosis in the clinical setting.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Mama/patología , Imagen por Resonancia Magnética/instrumentación , Elasticidad , Diseño de Equipo , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Presión , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
J Am Coll Cardiol ; 58(12): 1262-70, 2011 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-21903061

RESUMEN

OBJECTIVES: We sought to define age-related geometric changes of the aortic arch and determine their relationship to central aortic stiffness and left ventricular (LV) remodeling. BACKGROUND: The proximal aorta has been shown to thicken, enlarge in diameter, and lengthen with aging in humans. However, no systematic study has described age-related longitudinal and transversal remodeling of the aortic arch and their relationship with LV mass and remodeling. METHODS: We studied 100 subjects (55 women, 45 men, average age 46 ± 16 years) free of overt cardiovascular disease using magnetic resonance imaging to determine aortic arch geometry (length, diameters, height, width, and curvature), aortic arch function (local aortic distensibility and arch pulse wave velocity [PWV]), and LV volumes and mass. Radial tonometry was used to calculate central blood pressure. RESULTS: Aortic diameters and arch length increased significantly with age. The ascending aorta length increased most, with age leading to aortic arch widening and decreased curvature. These geometric changes of the aortic arch were significantly related to decreased ascending aortic distensibility, increased aortic arch PWV (p < 0.001), and increased central blood pressures (p < 0.001). Increased ascending aortic diameter, lengthening, and decreased curvature of the aortic arch (unfolding) were all significantly associated with increased LV mass and concentric remodeling independently of age, sex, body size, and central blood pressure (p < 0.01). CONCLUSIONS: Age-related unfolding of the aortic arch is related to increased proximal aortic stiffness in individuals without cardiovascular disease and associated with increased LV mass and mass-to-volume ratio independent of age, body size, central pressure, and cardiovascular risk factors.


Asunto(s)
Aorta Torácica/fisiopatología , Ventrículos Cardíacos/patología , Función Ventricular Izquierda/fisiología , Remodelación Ventricular/fisiología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Aorta Torácica/patología , Presión Sanguínea/fisiología , Estudios Transversales , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Estudios Prospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA