Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
MAGMA ; 35(5): 805-815, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35107697

RESUMEN

OBJECTIVE: Blood oxygenation can be measured using magnetic resonance using the paramagnetic effect of deoxy-haemoglobin, which decreases the [Formula: see text] relaxation time of blood. This [Formula: see text] contrast has been well characterised at the [Formula: see text] fields used in MRI (1.5 T and above). However, few studies have characterised this effect at lower magnetic fields. Here, the feasibility of blood oximetry at low field based on [Formula: see text] changes that are within a physiological relevant range is explored. This study could be used for specifying requirements for construction of a monitoring device based on low field permanent magnet systems. METHODS: A continuous flow circuit was used to control parameters such as oxygen saturation and temperature in a sample of blood. It flowed through a variable field magnet, where CPMG experiments were performed to measure its [Formula: see text]. In addition, the oxygen saturation was monitored by an optical sensor for comparison with the [Formula: see text] changes. RESULTS: These results show that at low [Formula: see text] fields, the change in blood [Formula: see text] due to oxygenation is small, but still detectable. The data measured at low fields are also in agreement with theoretical models for the oxy-deoxy [Formula: see text] effect. CONCLUSION: [Formula: see text] changes in blood due to oxygenation were observed at fields as low as 0.1 T. These results suggest that low field NMR relaxometry devices around 0.3 T could be designed to detect changes in blood oxygenation.


Asunto(s)
Oximetría , Saturación de Oxígeno , Imagen por Resonancia Magnética , Oxígeno
2.
Biol Psychiatry Glob Open Sci ; 3(3): 386-397, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37519460

RESUMEN

Background: Hearing impairment is a risk factor for schizophrenia. Patients with 22q11.2 deletion syndrome have a 25% to 30% risk of schizophrenia, and up to 60% also have varying degrees of hearing impairment, primarily from middle-ear inflammation. The Df1/+ mouse model of 22q11.2 deletion syndrome recapitulates many features of the human syndrome, including schizophrenia-relevant brain abnormalities and high interindividual variation in hearing ability. However, the relationship between brain abnormalities and hearing impairment in Df1/+ mice has not been examined. Methods: We measured auditory brainstem responses, cortical auditory evoked potentials, and/or cortical parvalbumin-positive (PV+) interneuron density in over 70 adult mice (32 Df1/+, 39 wild-type). We also performed longitudinal auditory brainstem response measurements in an additional 20 animals (13 Df1/+, 7 wild-type) from 3 weeks of age. Results: Electrophysiological markers of central auditory excitability were elevated in Df1/+ mice. PV+ interneurons, which are implicated in schizophrenia pathology, were reduced in density in the auditory cortex but not the secondary motor cortex. Both auditory brain abnormalities correlated with hearing impairment, which affected approximately 60% of adult Df1/+ mice and typically emerged before 6 weeks of age. Conclusions: In the Df1/+ mouse model of 22q11.2 deletion syndrome, abnormalities in central auditory excitability and auditory cortical PV+ immunoreactivity correlate with hearing impairment. This is the first demonstration of cortical PV+ interneuron abnormalities correlating with hearing impairment in a mouse model of either schizophrenia or middle-ear inflammation.

3.
IEEE Trans Biomed Eng ; 70(2): 671-680, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-37021844

RESUMEN

OBJECTIVE: We have developed a single-sided magnet system that allows Magnetic Resonance relaxation and diffusion parameters to be measured. METHODS: A single-sided magnet system has been developed, using an array of permanent magnets. The magnet positions are optimised to produce a B0 magnetic field with a spot that is relatively homogenous and can project into a sample. NMR relaxometry experiments are used to measure quantitative parameters such as T2, T1 and apparent diffusion coefficient (ADC) on samples on the benchtop. To explore preclinical application, we test whether it can detect changes during acute global cerebral hypoxia in an ovine model. RESULTS: The magnet produces a 0.2 T field projected into the sample. Measurements of benchtop samples show that it can measure T1, T2 and ADC, producing trends and values that are in line with literature measurements. In-vivo studies show a decrease in T2 during cerebral hypoxia that recovers following normoxia. CONCLUSION: The single-sided MR system has the potential to allow non-invasive measurements of the brain. We also demonstrate that it can operate in a pre-clinical environment, allowing T2 to be monitored during brain tissue hypoxia. SIGNIFICANCE: MRI is a powerful technique for non-invasive diagnosis in the brain, but its application has been limited by the requirements for magnetic field strength and homogeneity that imaging methods have. The technology described in this study provides a portable alternative to acquiring clinically significant MR parameters without the need for traditional imaging equipment.


Asunto(s)
Hipoxia Encefálica , Imanes , Animales , Ovinos , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA