Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Am J Hum Genet ; 111(1): 24-38, 2024 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-38103548

RESUMEN

The 2015 American College of Medical Genetics and Genomics and the Association for Molecular Pathology variant classification publication established a standard employed internationally to guide laboratories in variant assessment. Those recommendations included both pathogenic (PP1) and benign (BS4) criteria for evaluating the inheritance patterns of variants, but details of how to apply those criteria at appropriate evidence levels were sparse. Several publications have since attempted to provide additional guidance, but anecdotally, this issue is still challenging. Additionally, it is not clear that those prior efforts fully distinguished disease-gene identification considerations from variant pathogenicity considerations nor did they address autosomal-recessive and X-linked inheritance. Here, we have taken a mixed inductive and deductive approach to this problem using real diseases as examples. We have developed a practical heuristic for genetic co-segregation evidence and have also determined that the specific phenotype criterion (PP4) is inseparably coupled to the co-segregation criterion. We have also determined that negative evidence at one locus constitutes positive evidence for other loci for disorders with locus heterogeneity. Finally, we provide a points-based system for evaluating phenotype and co-segregation as evidence types to support or refute a locus and show how that can be integrated into the Bayesian framework now used for variant classification and consistent with the 2015 guidelines.


Asunto(s)
Pruebas Genéticas , Variación Genética , Humanos , Teorema de Bayes , Variación Genética/genética , Genoma Humano , Fenotipo
2.
Genet Med ; : 101213, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39030733

RESUMEN

PURPOSE: To investigate the number of rare missense variants observed in human genome sequences by ACMG/AMP PP3/BP4 evidence strength, following the calibrated PP3/BP4 computational recommendations. METHODS: Missense variants from the genome sequences of 300 probands from the Rare Genomes Project with suspected rare disease were analyzed using computational prediction tools able to reach PP3_Strong and BP4_Moderate evidence strengths (BayesDel, MutPred2, REVEL, and VEST4). The numbers of variants at each evidence strength were analyzed across disease-associated genes and genome-wide. RESULTS: From a median of 75.5 rare (≤1% allele frequency) missense variants in disease-associated genes per proband, a median of one reached PP3_Strong, 3-5 PP3_Moderate, and 3-5 PP3_Supporting. Most were allocated BP4 evidence (median 41-49 per proband) or were indeterminate (median 17.5-19 per proband). Extending the analysis to all protein-coding genes genome-wide, the number of PP3_Strong variants increased approximately 2.6-fold compared to disease-associated genes, with a median per proband of 1-3 PP3_Strong, 8-16 PP3_Moderate, and 10-17 PP3_Supporting. CONCLUSION: A small number of variants per proband reached PP3_Strong and PP3_Moderate in 3,424 disease-associated genes, and though not the intended use of the recommendations, also genome-wide. Use of PP3/BP4 evidence as recommended from calibrated computational prediction tools in the clinical diagnostic laboratory is unlikely to inappropriately contribute to the classification of an excessive number of variants as Pathogenic or Likely Pathogenic by ACMG/AMP rules.

4.
HGG Adv ; 5(2): 100270, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38219013

RESUMEN

Long QT syndrome (LQTS), caused by the dysfunction of cardiac ion channels, increases the risk of sudden death in otherwise healthy young people. For many variants in LQTS genes, there is insufficient evidence to make a definitive genetic diagnosis. We have established a robust functional patch-clamp assay to facilitate classification of missense variants in KCNH2, one of the key LQTS genes. A curated set of 30 benign and 30 pathogenic missense variants were used to establish the range of normal and abnormal function. The extent to which variants reduced protein function was quantified using Z scores, the number of standard deviations from the mean of the normalized current density of the set of benign variant controls. A Z score of -2 defined the threshold for abnormal loss of function, which corresponds to 55% wild-type function. More extreme Z scores were observed for variants with a greater loss-of-function effect. We propose that the Z score for each variant can be used to inform the application and weighting of abnormal and normal functional evidence criteria (PS3 and BS3) within the American College of Medical Genetics and Genomics variant classification framework. The validity of this approach was demonstrated using a series of 18 KCNH2 missense variants detected in a childhood onset LQTS cohort, where the level of function assessed using our assay correlated to the Schwartz score (a scoring system used to quantify the probability of a clinical diagnosis of LQTS) and the length of the corrected QT (QTc) interval.


Asunto(s)
Síndrome de QT Prolongado , Mutación Missense , Niño , Humanos , Muerte Súbita , Canal de Potasio ERG1/genética , Corazón , Síndrome de QT Prolongado/diagnóstico
5.
medRxiv ; 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38496501

RESUMEN

Purpose: To investigate the number of rare missense variants observed in human genome sequences by ACMG/AMP PP3/BP4 evidence strength, following the calibrated PP3/BP4 computational recommendations. Methods: Missense variants from the genome sequences of 300 probands from the Rare Genomes Project with suspected rare disease were analyzed using computational prediction tools able to reach PP3_Strong and BP4_Moderate evidence strengths (BayesDel, MutPred2, REVEL, and VEST4). The numbers of variants at each evidence strength were analyzed across disease-associated genes and genome-wide. Results: From a median of 75.5 rare (≤1% allele frequency) missense variants in disease-associated genes per proband, a median of one reached PP3_Strong, 3-5 PP3_Moderate, and 3-5 PP3_Supporting. Most were allocated BP4 evidence (median 41-49 per proband) or were indeterminate (median 17.5-19 per proband). Extending the analysis to all protein-coding genes genome-wide, the number of PP3_Strong variants increased approximately 2.6-fold compared to disease-associated genes, with a median per proband of 1-3 PP3_Strong, 8-16 PP3_Moderate, and 10-17 PP3_Supporting. Conclusion: A small number of variants per proband reached PP3_Strong and PP3_Moderate in 3,424 disease-associated genes, and though not the intended use of the recommendations, also genome-wide. Use of PP3/BP4 evidence as recommended from calibrated computational prediction tools in the clinical diagnostic laboratory is unlikely to inappropriately contribute to the classification of an excessive number of variants as Pathogenic or Likely Pathogenic by ACMG/AMP rules.

6.
BMC Res Notes ; 17(1): 62, 2024 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-38433186

RESUMEN

OBJECTIVE: Data from DNA genotyping via a 96-SNP panel in a study of 25,015 clinical samples were utilized for quality control and tracking of sample identity in a clinical sequencing network. The study aimed to demonstrate the value of both the precise SNP tracking and the utility of the panel for predicting the sex-by-genotype of the participants, to identify possible sample mix-ups. RESULTS: Precise SNP tracking showed no sample swap errors within the clinical testing laboratories. In contrast, when comparing predicted sex-by-genotype to the provided sex on the test requisition, we identified 110 inconsistencies from 25,015 clinical samples (0.44%), that had occurred during sample collection or accessioning. The genetic sex predictions were confirmed using additional SNP sites in the sequencing data or high-density genotyping arrays. It was determined that discrepancies resulted from clerical errors (49.09%), samples from transgender participants (3.64%) and stem cell or bone marrow transplant patients (7.27%) along with undetermined sample mix-ups (40%) for which sample swaps occurred prior to arrival at genome centers, however the exact cause of the events at the sampling sites resulting in the mix-ups were not able to be determined.


Asunto(s)
Servicios de Laboratorio Clínico , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Trasplante de Médula Ósea , Genotipo , Laboratorios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA