Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Int Ophthalmol ; 43(9): 3087-3096, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37083872

RESUMEN

PURPOSE: Laser corneal reshaping is a common eye surgery utilized to overcome many vision disorders. Different UV laser wavelengths can be effective in the treatment. However, the ArF excimer laser (193 nm) is the most commonly used due to its high absorption in the cornea. In the current study, we investigate the efficacy of applying a solid-state laser (Nd:YAG fourth harmonic at 266 nm) for the corneal reshaping procedure. METHODS: The utilized laser is generated using an optical setup based on a BBO nonlinear crystal which converts the Q-switched laser (532 nm) to its fourth harmonic (266 nm). Different pulse energies were applied with the same number of the shoots on ex vivo rabbit corneas, and the histological effect is studied. Moreover, the possible thermal damage on the treated corneal tissues was inspected via electron microscope. Additionally, the DNA damage on the corneal cells due to the application of the proposed laser was examined and compared with the existing technology (ArF Excimer laser at 193 nm) using the comet assay. RESULTS: The histological examination revealed an appropriate ablation result with the minimum thermal effect at 1.5 mJ and 2.0 mJ. The overall results show that applying 50-shoots of the 1.5-mJ pulse energy using the proposed 266-nm solid-state laser produces the optimum ablation effect with the minimum thermal damage, and almost the same DNA damage occurred using the commercial 193-nm ArF excimer laser. CONCLUSION: Solid-state laser at 266 nm could be a good alternative to the common 193-nm excimer laser for corneal reshaping procedures.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Animales , Conejos , Proyectos Piloto , Córnea/cirugía , Córnea/patología , Láseres de Excímeros/uso terapéutico , Luz , Láseres de Estado Sólido/uso terapéutico
2.
PLoS One ; 16(1): e0246395, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33513197

RESUMEN

Quantitative measurement of nanoscale surface roughness of articular cartilage tissue is significant to assess the surface topography for early treatment of osteoarthritis, the most common joint disease worldwide. Since it was not established by clinical diagnostic tools, the current studies have been suggesting the use of alternative diagnostic tools using pre-clinical methods. This study aims to measure the nanoscale surface roughness of articular cartilage tissue utilizing biospeckle which is used as a non-destructive and non-contact optical imaging technique. An experimental setup was implemented to capture biospeckle images from twelve cross-section areas of articular cartilage tissue gathered from bovine knee joints at 632 nm wavelength laser radiation. Then, to analyze the biospeckle image, a second-order statistical-based method was proposed through the combination of 308 highly correlated statistical features extracted from implemented gray-level co-occurrence matrices by employing principal component analysis. The result indicated that the measurement of the nanoscale surface roughness based on the first principal component only is able to provide accurate and precise quantitative measurement of early signs of articular cartilage degeneration up to 2500 nm.


Asunto(s)
Enfermedades de los Cartílagos/diagnóstico por imagen , Cartílago Articular/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Rayos Láser , Imagen Óptica , Animales , Bovinos , Propiedades de Superficie
3.
PLoS One ; 15(7): e0236835, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32730365

RESUMEN

We propose a new optical method based on comparative holographic projection for visual comparison between two abnormal follow-up magnetic resonance (MR) exams of glioblastoma patients to effectively visualize and assess tumor progression. First, the brain tissue and tumor areas are segmented from the MR exams using the fast marching method (FMM). The FMM approach is implemented on a computed pixel weight matrix based on an automated selection of a set of initialized target points. Thereafter, the associated phase holograms are calculated for the segmented structures based on an adaptive iterative Fourier transform algorithm (AIFTA). Within this approach, a spatial multiplexing is applied to reduce the speckle noise. Furthermore, hologram modulation is performed to represent two different reconstruction schemes. In both schemes, all calculated holograms are superimposed into a single two-dimensional (2D) hologram which is then displayed on a reflective phase-only spatial light modulator (SLM) for optical reconstruction. The optical reconstruction of the first scheme displays a 3D map of the tumor allowing to visualize the volume of the tumor after treatment and at the progression. Whereas, the second scheme displays the follow-up exams in a side-by-side mode highlighting tumor areas, so the assessment of each case can be fast achieved. The proposed system can be used as a valuable tool for interpretation and assessment of the tumor progression with respect to the treatment method providing an improvement in diagnosis and treatment planning.


Asunto(s)
Algoritmos , Neoplasias Encefálicas/patología , Encéfalo/anatomía & histología , Holografía/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Neoplasias Encefálicas/diagnóstico por imagen , Progresión de la Enfermedad , Humanos , Procesamiento de Señales Asistido por Computador
4.
Materials (Basel) ; 10(7)2017 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-28773080

RESUMEN

The application of He-Ne laser technologies for description of articular cartilage degeneration, one of the most common diseases worldwide, is an innovative usage of these technologies used primarily in material engineering. Plain radiography and magnetic resonance imaging are insufficient to allow the early assessment of the disease. As surface roughness of articular cartilage is an important indicator of articular cartilage degeneration progress, a safe and noncontact technique based on laser speckle image to estimate the surface roughness is provided. This speckle image from the articular cartilage surface, when illuminated by laser beam, gives very important information about the physical properties of the surface. An experimental setup using a low power He-Ne laser and a high-resolution digital camera was implemented to obtain speckle images of ten bovine articular cartilage specimens prepared for different average roughness values. Texture analysis method based on gray-level co-occurrence matrix (GLCM) analyzed on the captured speckle images is used to characterize the surface roughness of the specimens depending on the computation of Haralick's texture features. In conclusion, this promising method can accurately estimate the surface roughness of articular cartilage even for early signs of degeneration. The method is effective for estimation of average surface roughness values ranging from 0.09 µm to 2.51 µm with an accuracy of 0.03 µm.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA