Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Hum Mol Genet ; 29(12): 1969-1985, 2020 07 29.
Artículo en Inglés | MEDLINE | ID: mdl-32068834

RESUMEN

Vitamin B12 or cobalamin (Cbl) metabolism can be affected by genetic defects leading to defective activity of either methylmalonyl-CoA mutase or methionine synthase or both enzymes. Patients usually present with a wide spectrum of pathologies suggesting that various cellular processes could be affected by modifications in gene expression. We have previously demonstrated that these genetic defects are associated with subcellular mislocalization of RNA-binding proteins (RBP) and subsequent altered nucleo-cytoplasmic shuttling of mRNAs. In order to characterize the possible changes of gene expression in these diseases, we have investigated global gene expression in fibroblasts from patients with cblC and cblG inherited disorders by RNA-seq. The most differentially expressed genes are strongly associated with developmental processes, neurological, ophthalmologic and cardiovascular diseases. These associations are consistent with the clinical presentation of cblC and cblG disorders. Multivariate analysis of transcript processing revaled splicing alterations that led to dramatic changes in cytoskeleton organization, response to stress, methylation of macromolecules and RNA binding. The RNA motifs associated with this differential splicing reflected a potential role of RBP such as HuR and HNRNPL. Proteomic analysis confirmed that mRNA processing was significantly disturbed. This study reports a dramatic alteration of gene expression in fibroblasts of patients with cblC and cblG disorders, which resulted partly from disturbed function of RBP. These data suggest to evaluate the rescue of the mislocalization of RBP as a potential strategy in the treatment of severe cases who are resistant to classical treatments with co-enzyme supplements.


Asunto(s)
5-Metiltetrahidrofolato-Homocisteína S-Metiltransferasa/genética , Oxidorreductasas/genética , Deficiencia de Vitamina B 12/genética , Vitamina B 12/genética , Empalme Alternativo/genética , Línea Celular , Proteína 1 Similar a ELAV/genética , Fibroblastos/metabolismo , Regulación de la Expresión Génica/genética , Humanos , Proteómica , Proteínas de Unión al ARN/genética , Ribonucleoproteínas/genética , Vitamina B 12/metabolismo , Deficiencia de Vitamina B 12/patología
2.
Int J Mol Sci ; 20(22)2019 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-31739389

RESUMEN

Deficiencies in methyl donors, folate, and vitamin B12 are known to lead to brain function defects. Fetal development is the most studied but data are also available for such an impact in elderly rats. To compare the functional consequences of nutritional deficiency in young versus adult rats, we monitored behavioral outcomes of cerebellum and hippocampus circuits in the offspring of deficient mother rats and in adult rats fed a deficient diet from 2 to 8 months-of-age. We present data showing that the main deleterious consequences are found in young ages compared to adult ones, in terms of movement coordination and learning abilities. Moreover, we obtained sex and age differences in the deleterious effects on these functions and on neuronal layer integrity in growing young rats, while deficient adults presented only slight functional alterations without tissue damage. Actually, the cerebellum and the hippocampus develop and maturate according to different time lap windows and we demonstrate that a switch to a normal diet can only rescue circuits that present a long permissive window of time, such as the cerebellum, whereas the hippocampus does not. Thus, we argue, as others have, for supplements or fortifications given over a longer time than the developmental period.


Asunto(s)
Encéfalo/metabolismo , Encéfalo/fisiopatología , Enfermedades Carenciales/complicaciones , Enfermedades Carenciales/metabolismo , Desarrollo Fetal , Trastornos del Neurodesarrollo/etiología , Trastornos del Neurodesarrollo/metabolismo , Animales , Cognición , Enfermedades Carenciales/etiología , Dieta , Modelos Animales de Enfermedad , Femenino , Deficiencia de Ácido Fólico/complicaciones , Deficiencia de Ácido Fólico/metabolismo , Hipocampo/metabolismo , Hipocampo/fisiopatología , Masculino , Aprendizaje por Laberinto , Ratas
3.
J Refract Surg ; 31(5): 333-7, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25974973

RESUMEN

PURPOSE: To analyze the repeatability of keratometric and white-to-white (WTW) distance measurements with the VERION Measurement Module (Alcon Laboratories, Inc., Fort Worth, TX) and to compare the measured data to the results of the IOLMaster (Carl Zeiss Meditec, Jena, Germany). METHODS: Three images were captured with the VERION and the flattest and steepest keratometric data, the astigmatism axis, and the WTW distance were recorded. Subsequently, the axial length, the keratometric data with axis, and the WTW distance were measured with an IOLMaster. The repeatability data of the keratometric value of the VERION System, converted to cross cylinder J0 and J45 vector components, were analyzed. The agreement data for keratometry obtained by the VERION System and the differences regarding keratometric data and WTW distance compared to IOLMaster were calculated. RESULTS: The measurements were conducted in 50 eyes of 50 healthy volunteers (median age: 50.32 years, range: 19.34 to 85.3 years). The flattest and the steepest keratometric data, the diopter of astigmatism, the J0 and J45 vector components, and WTW distance did not differ significantly between devices (P > .05). Intraclass correlation coefficients (range: 0.863 to 0.994) and Cronbach's alpha values (range: 0.950 to 0.998) were high for all parameters measured by the VERION System. CONCLUSIONS: The VERION System has high repeatability and agreement with the IOLMaster, making it suitable as an alternative tool in clinical practice.


Asunto(s)
Córnea/anatomía & histología , Técnicas de Diagnóstico Oftalmológico/instrumentación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Astigmatismo/diagnóstico , Longitud Axial del Ojo/anatomía & histología , Longitud Axial del Ojo/patología , Biometría/instrumentación , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
4.
J Refract Surg ; 30(9): 604-8, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25068890

RESUMEN

PURPOSE: To measure surgically induced astigmatism (SIA) on the posterior surface of the cornea using Scheimpflug-based keratometry on eyes with with-the-rule astigmatism. METHODS: Repeated Scheimpflug-based keratometry was obtained preoperatively and a mean of 8.65 weeks postoperatively following superior clear corneal incisions. Differences in the keratometric values and SIA were determined on the anterior and posterior surfaces separately and the data were analyzed. RESULTS: The study included 88 eyes of 88 patients (age range: 46.4 to 87.5 years), with the steepest total corneal meridian between 75° and 105°. Preoperatively, the magnitude of the anterior and posterior corneal astigmatism was 0.74 ± 0.44 and 0.29 ± 0.14 diopters (D), respectively, which was greater than 0.5 D in 10 eyes (11.36%). The difference between preoperative and postoperative keratometric data on the posterior surface was significant, as was the difference between the preoperative and postoperative posterior astigmatism. The mean magnitude of posterior corneal SIA was 0.32 ± 0.29 D, which was 0.5 D or greater in 22 eyes (25.00%). A statistically significant correlation was observed between the diopter of the preoperatively measured posterior corneal astigmatism and the postoperative SIA on the posterior surface (r = 0.34, P = .001). The correlation was not significant between SIA on the anterior and posterior surfaces (r = 0.10, P = .36). CONCLUSIONS: SIA on the posterior surface of the cornea may have a significant role, especially in cases of toric intraocular lens implantation. Posterior corneal astigmatism and SIA may have a significant clinical impact on more precise planning of cataract surgeries.


Asunto(s)
Astigmatismo/etiología , Astigmatismo/fisiopatología , Córnea/fisiopatología , Facoemulsificación/efectos adversos , Anciano , Anciano de 80 o más Años , Catarata/complicaciones , Córnea/cirugía , Paquimetría Corneal , Topografía de la Córnea , Humanos , Implantación de Lentes Intraoculares , Persona de Mediana Edad , Facoemulsificación/métodos
5.
EBioMedicine ; 99: 104911, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38168585

RESUMEN

BACKGROUND: The high variability in clinical and metabolic presentations of inborn errors of cobalamin (cbl) metabolism (IECM), such as the cblC/epicblC types with combined deficits in methylmalonyl-coA mutase (MUT) and methionine synthase (MS), are not well understood. They could be explained by the impaired expression/activity of enzymes from other metabolic pathways. METHODS: We performed metabolomic, genomic, proteomic, and post-translational modification (PTM) analyses in fibroblasts from three cblC cases and one epi-cblC case compared with three cblG cases with specific MS deficits and control fibroblasts. FINDINGS: CblC patients had metabolic profilings consistent with altered urea cycle, glycine, and energy mitochondrial metabolism. Metabolomic analysis showed partial disruption and increased glutamate/ketoglutarate anaplerotic pathway of the tricarboxylic acid cycle (TCA), in patient fibroblasts. RNA-seq analysis showed decreased expression of MT-TT (mitochondrial tRNA threonine), MT-TP (mitochondrial tRNA proline), OXCT1 (succinyl CoA:3-oxoacid CoA transferase deficiency), and MT-CO1 (cytochrome C oxidase subunit 1). Proteomic changes were observed for key mitochondrial enzymes, including NADH:ubiquinone oxidoreductase subunit A8 (NDUFA8), carnitine palmitoyltransferase 2 (CPT2), and ubiquinol-cytochrome C reductase, complex III subunit X (UQCR10). Propionaldehyde addition in ornithine aminotransferase was the predominant PTM in cblC cells and could be related with the dramatic cellular increase in propionate and methylglyoxalate. It is consistent with the decreased concentration of ornithine reported in 3 cblC cases. Whether the changes detected after multi-omic analyses underlies clinical features in cblC and cblG types of IECM, such as peripheral and central neuropathy, cardiomyopathy, pulmonary hypertension, development delay, remains to be investigated. INTERPRETATION: The omics-related effects of IECM on other enzymes and metabolic pathways are consistent with the diversity and variability of their age-related metabolic and clinical manifestations. PTMs are expected to produce cumulative effects, which could explain the influence of age on neurological manifestations. FUNDING: French Agence Nationale de la Recherche (Projects PREDICTS and EpiGONE) and Inserm.


Asunto(s)
Multiómica , Vitamina B 12 , Humanos , Vitamina B 12/metabolismo , Proteómica , Oxidorreductasas/metabolismo , Fibroblastos/metabolismo , ARN de Transferencia/metabolismo
6.
J Refract Surg ; 29(5): 326-31, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23459157

RESUMEN

PURPOSE: To assess keratometric and higher-order aberrations of the anterior and posterior cornea and their age-related changes. METHODS: This study investigated one healthy eye of 227 patients (mean age: 55.15 ± 21.2 years; range: 16 to 90 years; 135 right eyes, 92 left eyes). Images were captured from each eye with Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) using automatic mode. Keratometric, astigmatism data, and corneal higher-order aberrations were analyzed. RESULTS: With respect to laterality, no deviance was found in any of the parameters (P > .05). Mean refractive error was 0.52 ± 0.23 diopters. The level of astigmatism decreased significantly with advancing age for both the anterior and posterior corneal surfaces (P < .05). The overall root mean square of the higher-order aberration increased continuously with age (r = 0.517; P < .01), which can be explained by the combined effect of the increased in both the anterior and posterior corneal root mean square higher-order aberrations. Of the higher-order aberrations, the constant increase of the primary and secondary spherical aberration with aging (P < .01) is caused by the spherical aberration growth of the anterior surface. Apart from these, only the vertical coma aberration of the posterior surface and the vertical trefoil aberrations of both the anterior and posterior surfaces showed a significantly positive correlation with aging (P < .05). CONCLUSIONS: Corneal astigmatism showed a significant decrease with aging. Of the higher-order aberrations, primary and secondary spherical aberrations, vertical coma, and vertical trefoil significantly increase with age, whereas other higher-order aberrations show no correlation with aging.


Asunto(s)
Envejecimiento/fisiología , Astigmatismo/fisiopatología , Aberración de Frente de Onda Corneal/fisiopatología , Endotelio Corneal/fisiología , Epitelio Corneal/fisiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Paquimetría Corneal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fotograbar/instrumentación , Adulto Joven
7.
J Refract Surg ; 29(8): 558-63, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23909783

RESUMEN

PURPOSE: To analyze the repeatability of a new device measuring ocular biomechanical properties, central corneal thickness (CCT), and intraocular pressure (IOP) and to investigate these parameters and their correlations in healthy eyes. METHODS: Three consecutive measurements were performed on each eye using the CorVis ST device (Oculus Optikgeräte, Inc., Wetzler, Germany). Ten specific parameters, CCT, and IOP were measured. Biometric data were recorded with IOLMaster (Carl Zeiss Meditec, Jena, Germany). RESULTS: This study comprised 75 eyes of 75 healthy volunteers (mean age: 61.24 ± 15.72 years). Mean IOP was 15.02 ± 2.90 mm Hg and mean CCT was 556.33 ± 33.13 µm. Intraclass correlation coefficient (ICC) was 0.865 for IOP and 0.970 for CCT, and coefficient of variation was 0.069 for IOP and 0.008 for CCT. ICC was 0.758 for maximum amplitude at highest concavity and 0.784 for first applanation time, and less than 0.6 for all other parameters. The device-specific data showed no significant relationship with age and axial length. Flattest and steepest keratometric values and IOP showed a significant correlation with the 10 device-specific parameters. CONCLUSIONS: The CorVis ST showed high repeatability for only IOP and pachymetric values. Single measurements are not reliable for the 10 device-specific parameters. The device allows for conducting clinical examinations and screening for surgeries altering ocular biomechanical properties with some form of averaging of multiple measurements.


Asunto(s)
Córnea/fisiología , Tonometría Ocular/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Córnea/diagnóstico por imagen , Diseño de Equipo , Humanos , Presión Intraocular , Microscopía Acústica , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Adulto Joven
8.
Cells ; 12(9)2023 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-37174668

RESUMEN

Impairment of one-carbon metabolism during pregnancy, either due to nutritional deficiencies in B9 or B12 vitamins or caused by specific genetic defects, is often associated with neurological defects, including cognitive dysfunction that persists even after vitamin supplementation. Animal nutritional models do not allow for conclusions regarding the specific brain mechanisms that may be modulated by systemic compensations. Using the Cre-lox system associated to the neuronal promoter Thy1.2, a knock-out model for the methionine synthase specifically in the brain was generated. Our results on the neurobehavioral development of offspring show that the absence of methionine synthase did not lead to growth retardation, despite an effective reduction of both its expression and the methylation status in brain tissues. Behaviors were differently affected according to their functional outcome. Only temporary retardations were recorded in the acquisition of vegetative functions during the suckling period, compared to a dramatic reduction in cognitive performance after weaning. Investigation of the glutamatergic synapses in cognitive areas showed a reduction of AMPA receptors phosphorylation and clustering, indicating an epigenomic effect of the neuronal deficiency of methionine synthase on the reduction of glutamatergic synapses excitability. Altogether, our data indicate that cognitive impairment associated with methionine synthase deficiency may not only result from neurodevelopmental abnormalities, but may also be the consequence of alterations in functional plasticity of the brain.


Asunto(s)
Errores Innatos del Metabolismo de los Aminoácidos , Disfunción Cognitiva , Ratones , Embarazo , Animales , Femenino , 5-Metiltetrahidrofolato-Homocisteína S-Metiltransferasa/metabolismo , Vitamina B 12
9.
Clin Epigenetics ; 15(1): 158, 2023 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-37798757

RESUMEN

BACKGROUND: MTR gene encodes the cytoplasmic enzyme methionine synthase, which plays a pivotal role in the methionine cycle of one-carbon metabolism. This cycle holds a significant importance in generating S-adenosylmethionine (SAM) and S-adenosylhomocysteine (SAH), the respective universal methyl donor and end-product of epigenetic transmethylation reactions. cblG type of inherited disorders of vitamin B12 metabolism due to mutations in MTR gene exhibits a wide spectrum of symptoms, including a retinopathy unresponsive to conventional therapies. METHODS: To unveil the underlying epigenetic pathological mechanisms, we conducted a comprehensive study of epigenomic-wide alterations of DNA methylation by NGS of bisulfited retinal DNA in an original murine model with conditional Mtr deletion in retinal tissue. Our focus was on postnatal day 21, a critical developmental juncture for ocular structure refinement and functional maturation. RESULTS: We observed delayed eye opening and impaired visual acuity and alterations in the one-carbon metabolomic profile, with a notable dramatic decline in SAM/SAH ratio predicted to impair DNA methylation. This metabolic disruption led to epigenome-wide changes in genes involved in eye development, synaptic plasticity, and retinoid metabolism, including promoter hypermethylation of Rarα, a regulator of Lrat expression. Consistently, we observed a decline in cone photoreceptor cells and reduced expression of Lrat, Rpe65, and Rdh5, three pivotal genes of eye retinoid metabolism. CONCLUSION: We introduced an original in vivo model for studying cblG retinopathy, which highlighted the pivotal role of altered DNA methylation in eye development, cone differentiation, and retinoid metabolism. This model can be used for preclinical studies of novel therapeutic targets.


Asunto(s)
Células Fotorreceptoras Retinianas Conos , Enfermedades de la Retina , Ratones , Animales , Células Fotorreceptoras Retinianas Conos/metabolismo , Ratones Transgénicos , Epigenoma , Metilación de ADN , S-Adenosilmetionina/metabolismo , Enfermedades de la Retina/metabolismo , Carbono/metabolismo , Retinoides/metabolismo
10.
Front Mol Biosci ; 8: 709395, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34277711

RESUMEN

The last two decades have seen the discovery of novel retroviruses that have resulted in severe negative consequences for human health. In late 2019, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerged with a high transmission rate and severe effects on human health, with 5% infected persons requiring hospitalisation and 3.81 million deaths to date globally. Aerosol particles containing virions are considered the main source of SARS CoV-2 transmission in this pandemic, with increased infection rates in confined spaces. Consequently, public and private institutions had to institute mitigation measures including the use of facial masks and social distancing to limit the spread of the virus. Moreover, the role of air purification and bio-decontamination is understood as being essential to mitigate viral spread. Various techniques can be applied to bio-decontaminate the air such as the use of filtration and radiation; however, these methods are expensive and not feasible for home use. Another method of air purification is where indoor plants can purify the air by the removal of air pollutants and habituated airborne microbes. The use of indoor plants could prove to be a cost-efficient way of indoor air-purification that could be adapted for a variety of environments with no need for special requirements and can also add an aesthetic value that can have an indirect impact on human health. In this review, we discuss the emergence of the COVID-19 pandemic and the currently used air purification methods, and we propose the use of indoor plants as a new possible eco-friendly tool for indoor air purification and for reducing the spread of COVID-19 in confined places.

11.
Ocul Immunol Inflamm ; 29(6): 1090-1101, 2021 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-32130054

RESUMEN

Purpose: To find immunomediator combinations which could sensitively indicate keratoconus progression.Methods: Tear samples of 42 patients with keratoconus were collected at baseline and at the end of a one-year follow-up. The concentrations of 13 mediators were measured by CBA. Based on Pentacam HR examination, eyes were divided into a non-progressive and a progressive group.Results: At the end of the follow-up, significant differences were observed in the release of IFNγ, IL-13, IL-17A, CCL5, MMP-13 and PAI-1 between the two groups. Changes in five Pentacam parameters correlated positively with changes in IFNγ, IL-13, IL-17A, CXCL8, CCL5, TIMP-1 and t-PA. We found that tear level of IL-13 in combination with NGF can predict the progression of keratoconus with 100% specificity and 80% sensitivity.Conclusion: The findings of our longitudinal study may underscore the importance of NGF and IL-13 tear levels in the prediction of keratoconus progression.


Asunto(s)
Proteínas del Ojo/metabolismo , Interleucina-13/metabolismo , Queratocono/diagnóstico , Factor de Crecimiento Nervioso/metabolismo , Lágrimas/metabolismo , Adolescente , Adulto , Anciano , Progresión de la Enfermedad , Femenino , Humanos , Queratocono/metabolismo , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Microscopía con Lámpara de Hendidura , Agudeza Visual/fisiología , Adulto Joven
12.
Int J Ophthalmol ; 13(9): 1443-1450, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32953585

RESUMEN

AIM: To evaluate detailed anterior segment parameters of patients with idiopathic inflammatory myopathies (IIM), including polymyositis (PM), and dermatomyositis (DM), and to clarify the associations between these data and clinical variables of IIM. METHODS: Totally 57 PM, 41 DM patients and 62 controls were enrolled in this cross-sectional, observational, case-control study. All study participants underwent Pentacam evaluation. Laboratory investigations consisted of different antibody assays, while extramuscular clinical assessments included Raynaud's phenomenon, dysphagia, interstitial lung disease, arthritis/arthralgia, and weight loss. Objective signs and subjective symptoms of dry eye disease (DED) were also evaluated. RESULTS: All pachymetric parameters [center, apex, thinnest and maximal keratometry (Kmax)] and corneal volume (CV) of both sides of PM patients proved to be significantly lower. Some pachymetric data were also noticed as significantly decreased compared to those of controls. Several significant differences were traced between anterior segment values and extramuscular manifestations of myositis, largely in case of arthritis/arthralgia and weight loss, whereas associations between anterior segment parameters and antibodies were weak. Objective clinical tests of DED were also significantly decreased in IIM patients. CONCLUSION: The results suggest that all IIM patients have thinner corneas compared with those of controls, and decreased corneal parameters are significantly associated with the occurrence of some extramuscular manifestations. In addition, IIM patients tend to develop objective signs of DED.

14.
Sci Rep ; 9(1): 3419, 2019 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-30833606

RESUMEN

Our purpose was to prospectively analyze the age-related changes of corneal Scheimpflug parameters in healthy subjects. Thirty-five eyes of 35 volunteers (age 14-67 years) were investigated with an average interval of 3.6 years. Changes of corneal parameters (flattest keratometric reading at anterior (K1F) and posterior surface (K1B), steepest keratometric reading at anterior (K2F) and posterior surface, anterior astigmatism, posterior astigmatism (AstigB), flat axis of anterior and posterior astigmatism (AxisB), thinnest pachymetric value (PachyMin), corneal volume (CV10-mm)) were analyzed. K1F and K2F decreased significantly during observation and showed stronger decrease in younger than in older individuals. Higher values proved to be more stable. K1B decreased significantly and the degree of decrease was dependent on its baseline value and age: in young subjects low values increased, high values decreased. AstigB decreased significantly and showed a baseline-dependent significant increase from lower and a significant decrease from higher initial values. Over time, the mean AxisB shifted significantly. PachyMin and CV decreased significantly with age, especially from higher baseline values in younger subjects. The results of this longitudinal study suggest that both corneal surfaces change significantly with age. We demonstrate for the first time that age and baseline values influence age-related changes of corneal parameters.


Asunto(s)
Envejecimiento/fisiología , Córnea/fisiología , Adolescente , Adulto , Anciano , Astigmatismo/diagnóstico por imagen , Astigmatismo/fisiopatología , Córnea/diagnóstico por imagen , Femenino , Voluntarios Sanos , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Adulto Joven
16.
J Cataract Refract Surg ; 34(6): 897-901, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18498992

RESUMEN

PURPOSE: To observe levels of plasminogen activator inhibitor (PAI) in human tears after photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK). SETTING: University medical center eye clinic. METHODS: Tear samples were collected from 46 eyes having PRK and 13 eyes having LASIK immediately before and after surgery and on the first (LASIK), third (PRK), and fifth (PRK) postoperative days. Analyses used enzyme-linked immunoassay, yielding 61 PRK PAI-1 determinations and 146 PRK and 35 LASIK PAI-2 determinations. RESULTS: All determinations of PRK PAI-1 were below the detection limit of 1 ng/mL of the original tear sample. In the PRK eyes, the mean PAI-2 concentration was 19.8 ng/mL +/- 23.4 (SD) in preoperative tears, 112.7 +/- 60.5 ng/mL immediately postoperatively, 12.1 +/- 19.5 ng/mL after 3 days, and 15.5 +/- 20.4 ng/mL after 5 days. In the LASIK eyes, the mean PAI-2 concentration was 19.0 +/- 33.1 ng/mL preoperatively, 111.5 +/- 69.2 ng/mL immediately postoperatively, and 15.7 +/- 18.8 ng/mL after 1 day. CONCLUSIONS: The similarity in the general time pattern of PAI-2 after PRK and LASIK suggests commonality in the enzymatic control response to corneal surgical wounding. Taken in the context of previous work, the observed levels of PAI-2 concentration in eyes with and without opacification suggest that in the postsurgical period, PAI-2 is not the controlling mechanism for the later development of corneal opacification and haze.


Asunto(s)
Proteínas del Ojo/metabolismo , Queratomileusis por Láser In Situ , Queratectomía Fotorrefractiva , Inhibidor 1 de Activador Plasminogénico/metabolismo , Inhibidor 2 de Activador Plasminogénico/metabolismo , Lágrimas/metabolismo , Adulto , Ensayo de Inmunoadsorción Enzimática , Humanos , Láseres de Excímeros , Miopía/metabolismo , Miopía/cirugía , Periodo Posoperatorio , Cicatrización de Heridas
17.
Curr Eye Res ; 43(1): 18-26, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29111836

RESUMEN

PURPOSE: Our aim was to compare densitometry data between keratoconus and normal corneas and to assess the long-term changes in corneal backscattered light values after corneal collagen cross-linking (CXL) treatment. MATERIAL AND METHODS: Retrospective analysis was performed on 26 eyes of normal patients (age: 32.71 ± 12.68 years) and 39 eyes of keratoconus patients (28.93 ± 7.59 years) using the Pentacam HR corneal densitometry module before CXL and during the postoperative period, which lasted a mean of 2.53 years (range: 1-4 years). Corneal backscattered light values in grey scale unit (GSU) were recorded for the anterior 120 µm, the center layer, and the posterior 60 µm of the cornea in four concentric, central rings. An additional calculation was performed with converting GSU values to GSU/cubic millimeters (mm3) with surface area calculations and using corneal thickness data. RESULTS: Statistically significant differences were observed between normal and keratoconus group densitometry values (in GSU/mm3) in all annuli of the center layer; all, but anterior layer of the 10-12 annuli; all annuli of the total thickness and in all values of the total diameter. In all these cases, the normal cornea showed higher GSU/mm3 values compared to keratoconus corneas (p < 0.05). One month after the CXL treatment, the GSU/mm3 data increased significantly in the anterior, the center, and the posterior zone (p < 0.05), followed by its slow decrease. At the end of the follow-up period, the GSU/mm3 values were significantly higher in all three zones compared to those before the CXL treatment (p < 0.01). CONCLUSION: Densitometry measurements can reflect the changes of optical quality of the cornea. These measurements may play a valuable role in assessing keratoconus and optical changes of the corneas after CXL treatment.


Asunto(s)
Colágeno/uso terapéutico , Córnea/patología , Reactivos de Enlaces Cruzados/uso terapéutico , Densitometría/métodos , Queratocono/tratamiento farmacológico , Luz , Adolescente , Adulto , Córnea/efectos de los fármacos , Córnea/fisiopatología , Topografía de la Córnea , Femenino , Estudios de Seguimiento , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Dispersión de Radiación , Factores de Tiempo , Adulto Joven
18.
Cornea ; 36(4): 434-439, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28079690

RESUMEN

PURPOSE: To study the reliability and repeatability of anterior segment measurements in patients who underwent penetrating keratoplasty with swept light source Fourier domain anterior segment optical coherence tomography (SS-OCT) in comparison with a high-resolution Scheimpflug camera. METHODS: Keratometry (K) and elevation data of the anterior and posterior corneal surfaces, central corneal thickness, and anterior chamber depth were determined in 56 postkeratoplasty eyes (mean age: 59.6 ± 16.5 yrs) with SS-OCT (CASIA SS-1000; Tomey) followed by Scheimpflug photography (Pentacam High Resolution; Oculus). Examinations were also performed on 48 right eyes of 48 age-matched healthy subjects (mean age: 66.3 ± 7.0 yrs). RESULTS: A statistically significant difference was detected between both tomographers in anterior flat K [1.7 ± 4.92 diopters (D)], posterior astigmatism (1.32 ± 5.7 D) and elevation (6.65 ± 14.07 µm), and central corneal thickness (27.39 ± 90.81 µm) and anterior chamber depth values (0.14 ± 0.66 mm) in patients who had undergone corneal transplantation (P < 0.05). In the postkeratoplasty group, repeatability of SS-OCT was higher for every anterior segment parameter in comparison with the Pentacam. In corneal grafts, the variability between 3 consecutive measurements on the same subject was remarkably lower for every parameter while using SS-OCT. CONCLUSIONS: In patients who had undergone corneal transplantation, SS-OCT provided more reliable and repeatable anterior segment evaluations when compared with the rotating Scheimpflug system. Our findings suggested that the tested high-resolution swept-source OCT system is a comprehensive and precise diagnostic tool for postoperative follow-up of patients who have undergone penetrating keratoplasty.


Asunto(s)
Córnea/patología , Queratoplastia Penetrante , Fotograbar , Tomografía de Coherencia Óptica , Anciano , Segmento Anterior del Ojo/patología , Enfermedades de la Córnea/cirugía , Paquimetría Corneal , Femenino , Análisis de Fourier , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
19.
Int J Ophthalmol ; 10(2): 217-222, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28251079

RESUMEN

AIM: To analyze the correlations between ocular biomechanical and biometric data of the eye, measured by Scheimpflug-based devices on healthy subjects. METHODS: Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology (CorVis ST) device on healthy eyes and the 10 device-specific parameters were recorded. Pentacam HR-derived parameters (corneal curvature radii on the anterior and posterior surfaces; apical pachymetry; corneal volume; corneal aberration data; depth, volume and angle of the anterior chamber) and axial length (AL) from IOLMaster were correlated with the 10 specific CorVis ST parameters. RESULTS: Measurements were conducted in 43 eyes of 43 volunteers (age 61.24±15.72y). The 10 specific CorVis ST data showed significant relationships with corneal curvature radii both on the anterior and posterior surface, pachymetric data, root mean square (RMS) data of lower-order aberrations, and posterior RMS of higher-order aberrations and spherical aberration of the posterior cornea. Anterior chamber depth showed a significant relationship, but there were no significant correlations between corneal volume, anterior chamber volume, mean chamber angle or AL and the 10 specific CorVis ST parameters. CONCLUSIONS: CorVis ST-generated parameters are influenced by corneal curvature radii, some corneal RMS data, but corneal volume, anterior chamber volume, chamber angle and AL have no correlation with the biomechanical parameters. The parameters measured by CorVis ST seem to refer mostly to corneal properties of the eye.

20.
Eur J Ophthalmol ; 27(3): 301-307, 2017 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-27646325

RESUMEN

PURPOSE: To analyze the effect of the accommodation on the anterior segment data (corneal and anterior chamber parameters) induced by short-time reading in a healthy, nonpresbyopic adult patient group. METHODS: Images of both eyes of nonpresbyopic volunteers were captured with a Scheimpflug device (Pentacam HR) in a nonaccommodative state. Fifteen minutes of reading followed and through fixation of the built-in target of Pentacam HR further accommodation was achieved and new images were captured by the device. Anterior segment parameters were observed and the differences were analyzed. RESULTS: Fifty-two healthy eyes of 26 subjects (range 20.04-28.58 years) were analyzed. No significant differences were observed in the keratometric values before and after the accommodative task (p = 0.35). A statistically significant difference was measured in the 5.0-mm-diameter and the 7.0-mm-diameter corneal volume (p = 0.01 and p = 0.03) between accommodation states. Corneal aberrometric data did not change significantly during short-term accommodation. Significant differences were observed between nonaccommodative and accommodative states of the eyes for all measured anterior chamber parameters. CONCLUSIONS: Among the parameters of the cornea, only corneal volume changed during the short-term accommodation process, showing some fine changes with accommodation of the cornea in young, emmetropic patients. The position of the pupil and the anterior chamber parameters were observed to change with accommodation as captured by a Scheimpflug device.


Asunto(s)
Acomodación Ocular/fisiología , Cámara Anterior/diagnóstico por imagen , Técnicas de Diagnóstico Oftalmológico , Emetropía/fisiología , Fotograbar/métodos , Lectura , Adulto , Cámara Anterior/fisiología , Femenino , Voluntarios Sanos , Humanos , Masculino , Pupila/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA