RESUMEN
OBJECTIVE: We examined whether preoperative inspiratory muscle weakness (IMW) is a risk factor for postoperative pulmonary complications (PPCs) in patients with esophageal cancer who underwent subtotal esophagectomy. METHODS: This single-center retrospective cohort study enrolled patients with esophageal cancer who underwent a scheduled subtotal esophagectomy between June 2020 and May 2022. Maximal inspiratory pressure (MIP) was measured as inspiratory muscle strength using a respiratory dynamometer, and we defined IMW as MIP < 80% of the predicted value. Our primary outcome comprised overall PPCs. We investigated the relationship between IMW and PPCs using the Bayesian logistic regression model. RESULTS: After exclusion, 72 patients were included in this study. IMW was identified in 26 patients (36%), and PPCs developed in 28 patients (39%). Among patients with IMW, 15 (58%) developed PPCs. Preoperative IMW was associated with PPCs (mean odds ratio [OR]: 3.58; 95% credible interval [95% CrI]: 1.29, 9.73) in the unweighted model. A similar association was observed in the weighted model adjusted for preoperative and intraoperative contributing factors (mean OR: 4.15; 95% CrI: 2.04, 8.45). CONCLUSIONS: Preoperative IMW was associated with PPCs in patients with esophageal cancer who underwent subtotal esophagectomy. This association remained after adjusting for preoperative and intraoperative contributing factors.
Asunto(s)
Neoplasias Esofágicas , Debilidad Muscular , Humanos , Estudios Retrospectivos , Teorema de Bayes , Factores de Riesgo , Debilidad Muscular/complicaciones , Neoplasias Esofágicas/cirugía , Complicaciones Posoperatorias/etiologíaRESUMEN
INTRODUCTION: Sarcopenia and chronic obstructive pulmonary disease (COPD) are risk factors for postoperative pulmonary complications (PPCs). Preoperative inspiratory muscle weakness is also a risk factor for PPCs. Sarcopenia and COPD are often associated with inspiratory muscle weakness. Respiratory sarcopenia has been defined as the coexistence of whole-body sarcopenia and respiratory muscle weakness. We report our experience with preoperative pulmonary rehabilitation, including inspiratory muscle training (IMT), in a patient with lung cancer and comorbid respiratory sarcopenia and COPD. CASE PRESENTATION: A 73-year-old man with squamous cell lung cancer (cStage IA2) was hospitalized for pulmonary rehabilitation before lung resection. He had comorbid severe sarcopenia and COPD (GOLD stage III). He also had inspiratory muscle weakness and a thin diaphragm. We conducted IMT on the patient in addition to aerobic exercise and instruction regarding sputum expectoration for 2 weeks before the surgery. Consequently, his pulmonary function, respiratory muscle strength, and exercise capacity improved. Segmentectomy was performed using video-assisted thoracic surgery. No postoperative complications occurred. CONCLUSION: IMT in a patient with lung cancer and comorbid respiratory sarcopenia and COPD resulted in improved respiratory muscle strength and pulmonary function. IMT may have reduced the risk of PPCs by strengthening the respiratory muscles and improving pulmonary function.
Asunto(s)
Neoplasias Pulmonares , Enfermedad Pulmonar Obstructiva Crónica , Sarcopenia , Masculino , Humanos , Anciano , Sarcopenia/complicaciones , Ejercicios Respiratorios/métodos , Músculos Respiratorios/fisiología , Neoplasias Pulmonares/complicaciones , Debilidad Muscular , Tolerancia al Ejercicio/fisiologíaRESUMEN
INTRODUCTION: Early implementation of neuromuscular electrical stimulation (NMES) has been reported to prevent muscle atrophy and physical functional decline in patients requiring mechanical ventilation. However, its effect in patients with acute exacerbation of interstitial lung disease (ILD) remains unclear. We herein report our experience using the NMES combined with mobilization in a patient with an acute exacerbation of rheumatoid arthritis-associated ILD (RA-ILD) requiring mechanical ventilation. CASE PRESENTATION: A 74-year-old man was admitted to the intensive care unit (ICU) and put on mechanical ventilation due to severe acute exacerbation of RA-ILD. Early mobilization and the NMES using a belt electrode skeletal muscle electrical stimulation system were started on day 7 of hospitalization (day 2 of ICU admission). The NMES duration was 20 min, performed once daily. The patient could perform mobility exercises on day 8 and could walk on day 16. We assessed his rectus femoris and quadriceps muscle thicknesses using ultrasound imaging, and found decreases of 4.5% and 8.4%, respectively, by day 14. On day 27, he could independently visit the lavatory, and the NMES was discontinued. He was instructed to start long-term oxygen therapy on day 49 and was discharged on day 63. His 6-minute walk distance was 308 m and his muscle thickness recovered to levels comparable to those at the initial evaluation at the time of discharge. CONCLUSION: Combining the NMES and mobilization started in the early phase and continued after ICU discharge was safe and effective in a patient with a severe acute exacerbation of RA-ILD.
RESUMEN
Mita M, Suzumori K, Kudo D, Saito K, Chida S, Hatakeyama K, Shimada Y, Miyakoshi N. Utility of a wearable robot for the fingers that uses pneumatic artificial muscles for patients with post-stroke spasticity. Jpn J Compr Rehabil Sci 2022; 13: 12-16. Objective: We investigated the utility of a wearable robot for the fingers that we developed using pneumatic artificial muscles for rehabilitation of patients with post-stroke spasticity. Methods: Three patients with post-stroke finger spasticity underwent rehabilitation for 20 minutes a day, 5 days a week, for 3 weeks. Passive range of motion, Modified Ashworth Scale (MAS), and circumference of each finger were measured before and after training and compared. Results: The range of motion and finger circumference increased when using a wearable robot. The MAS improved partially, and no exacerbation was observed. Conclusions: The wearable robot we developed is useful for rehabilitation of post-stroke spasticity and may improve venous return.
RESUMEN
OBJECTIVE: We have developed a robot for gait rehabilitation of paraplegics for use in combination with functional electrical stimulation (FES). The purpose of this study was to verify whether the robot-derived torque can be reduced by using FES in a healthy-person pseudo-paraplegic model. METHODS: Nine healthy participants (22-36 years old) participated in this study. The robot exoskeleton was designed based on the hip-knee-ankle-foot orthosis for paraplegia. Participants walked on a treadmill using a rehabilitation lift to support their weight. The bilateral quadriceps femoris and hamstrings were stimulated using FES. The participants walked both with and without FES, and two walking speeds, 0.8â and 1.2â km/h, were used. Participants walked for 1 min in each of the four conditions: (a) 0.8â km/h without FES, (b) 0.8â km/h with FES, (c) 1.2â km/h without FES, and (d) 1.2â km/h with FES. The required robot torques in these conditions were compared for each hip and knee joint. The maximum torque was compared using one-way analysis of variance to determine whether there was a difference in the amount of assist torque for each gait cycle. RESULTS: Walking with the exoskeleton robot in combination with FES significantly reduced the torque in hip and knee joints, except for the right hip during extension. CONCLUSIONS: In the healthy-participant pseudo-paraplegic model, walking with FES showed a reduction in the robot-derived torque at both the hip and knee joints. Our rehabilitation robot combined with FES has the potential to assist paraplegics with various degrees of muscle weakness and thereby provide effective rehabilitation.
RESUMEN
Objectives: Wearable devices such as fitness trackers have become popular in the healthcare field. Tracking heart rate and respiratory rate, in addition to physical activity, may provide an accurate picture of daily health. We believe that a combination of two types of devices can simultaneously measure and record physical activity, heart rate, and respiratory rate. However, the measurement accuracies of these two types of devices are not clear. This study aimed to determine the measurement accuracies of two wearable devices for heart and respiratory rate measurements. Methods: Ten healthy men performed incremental load tests (ILTs) and constant load tests (CLTs) on a cycle ergometer. The heart and respiratory rates were measured using wrist-worn (Silmee W22, TDK, Japan, Tokyo) and respiratory tracking devices (Spire Stone, Spire Health, San Francisco, CA, USA), respectively. A 12-lead electrocardiograph and the breath-by-breath method were used as external standards for heart and respiratory rates, respectively. Results: Bland-Altman analysis showed that heart rate had a fixed bias at rest and during ILT and CLT and had a proportional bias during CLT. The standard error values of the regression at rest and during CLT were less than 10 bpm for heart rate and less than 5.0 /min for respiratory rate. During ILT, the standard error was greater than 10 bpm for heart rate and approximately 5.0 /min for respiratory rate. Conclusions: The heart and respiratory rate measurements obtained using wearable devices were accurate within the practical margin of error.
RESUMEN
Patients with adult spinal deformity have various standing postures. Although several studies have reported a relationship between sagittal alignment and exacerbation of hip osteoarthritis, information is limited regarding how spinopelvic sagittal alignment changes affect hip joint loading. This study aimed to investigate the relationship between sagittal spinopelvic-lower limb alignment and the hip joint contact force (HCF) using a novel musculoskeletal model. We enrolled 20 women (78.3±6.7 years) from a single institution. Standing lateral radiographs were acquired to measure thoracic kyphosis, lumbar lordosis, the pelvic tilt, sacral slope, sagittal vertical axis (SVA), femur obliquity angle, and knee flexion angle. In the model simulation, the Anybody Modeling System was used, which alters muscle pathways using magnetic resonance imaging data. Each patient's alignment was entered into the model; the HCF and hip moment in the standing posture were calculated using inverse dynamics analysis. The relationship between the HCF and each parameter was examined using Spearman's correlation coefficient (r). The patients were divided into low SVA and high SVA groups, with a cutoff value of 50 mm for the SVA. The HCF was 168.2±60.1 N (%BW) and positively correlated with the SVA (r = 0.6343, p<0.01) and femur obliquity angle (r = 0.4670, p = 0.03). The HCF were 122.2 and 214.1 N (75.2% difference) in the low SVA and high SVA groups, respectively (p<0.01). The flexion moment was also increased in the high SVA group compared with that in the low SVA group (p = 0.03). The SVA and femur obliquity angle are factors related to the HCF, suggesting an association between adult spinal deformity and the exacerbation of hip osteoarthritis. Future studies will need to assess the relationship between the hip joint load and sagittal spinopelvic parameters in dynamic conditions.
Asunto(s)
Articulación de la Cadera/diagnóstico por imagen , Cifosis/diagnóstico por imagen , Lordosis/diagnóstico por imagen , Osteoartritis de la Cadera/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagen por Resonancia Magnética , Modelos Teóricos , Postura/fisiología , Rango del Movimiento ArticularRESUMEN
OBJECTIVE: We developed a rehabilitation robot to assist hemiplegics with gait exercises. The robot was combined with functional electrical stimulation (FES) of the affected side and was controlled by a real-time-feedback system that attempted to replicate the lower extremity movements of the non-affected limb on the affected side. We measured the reproducibility of the non-affected limb movements on the affected side using FES in non-disabled individuals and evaluated the smoothness of the resulting motion. METHOD: Ten healthy men participated in this study. The left side was defined as the non-affected side. The measured hip and knee joint angles of the non-affected side were reproduced on the pseudo-paralytic side using the robot's motors. The right quadriceps was stimulated with FES. Joint angles were measured with a motion capture system. We assessed the reproducibility of the amplitude from the maximum angle of flexion to extension during the walking cycle. The smoothness of the motion was evaluated using the angular jerk cost (AJC). RESULTS: The amplitude reproduction (%) was 87.9 ± 6.2 (mean ± standard deviation) and 71.5 ± 10.7 for the hip and knee joints, respectively. The walking cycle reproduction rate was 99.9 ± 0.1 and 99.8 ± 0.2 for the hip and knee joints, respectively. There were no statistically significant differences between results with FES versus those without FES. The AJC of the robot side was significantly smaller than that of the non-affected side. CONCLUSIONS: A master-slave gait rehabilitation system has not previously been attempted in hemiplegic patients. Our rehabilitation robot showed high reproducibility of motion on the affected side.
RESUMEN
CONCLUSIONS: Occupational therapy significantly improves shoulder range of motion in patients with accessory nerve palsy after radical neck dissection, but it has limited effects on the associated pain. OBJECTIVE: To evaluate the outcome of occupational therapy rehabilitation for patients with accessory nerve palsy. PATIENTS AND METHODS: The occupational therapy group involved 35 shoulders of 29 patients with accessory nerve palsy after radical neck dissection; the control group included 10 shoulders of 9 patients who did not receive occupational therapy. All patients had a malignant tumor in the head or neck that necessitated radical neck dissection. We collected data pertaining to resting pain, motion pain, and the active and passive range of motion during shoulder flexion and abduction. RESULTS: Occupational therapy did not adequately relieve resting or motion pain, but all patients achieved independence in activities of daily living and housekeeping activities. Although occupational therapy significantly improved shoulder elevation for all movements, shoulder elevation was significantly better for flexion than for active and passive abduction.
Asunto(s)
Enfermedades del Nervio Accesorio/rehabilitación , Traumatismos del Nervio Accesorio , Disección del Cuello , Terapia Ocupacional , Neoplasias de Oído, Nariz y Garganta/cirugía , Complicaciones Posoperatorias/rehabilitación , Hombro/inervación , Actividades Cotidianas/clasificación , Adulto , Cuidados Posteriores , Anciano , Femenino , Humanos , Contracción Isométrica/fisiología , Masculino , Persona de Mediana Edad , Regeneración Nerviosa/fisiología , Dimensión del Dolor , Rango del Movimiento ArticularRESUMEN
BACKGROUND: Given the extent of the surgical indications for pulmonary lobectomy in breathless patients, preoperative care and evaluation of pulmonary function are increasingly necessary. The aim of this study was to assess the contribution of preoperative pulmonary rehabilitation (PR) for reducing the incidence of postoperative pulmonary complications in non-small cell lung cancer (NSCLC) patients with chronic obstructive pulmonary disease (COPD). METHODS: The records of 116 patients with COPD, including 51 patients who received PR, were retrospectively analyzed. Pulmonary function testing, including slow vital capacity (VC) and forced expiratory volume in one second (FEV1 ), was obtained preoperatively, after PR, and at one and six months postoperatively. The recovery rate of postoperative pulmonary function was standardized for functional loss associated with the different resected lung volumes. Propensity score analysis generated matched pairs of 31 patients divided into PR and non-PR groups. RESULTS: The PR period was 18.7 ± 12.7 days in COPD patients. Preoperative pulmonary function was significantly improved after PR (VC 5.3%, FEV1 5.5%; P < 0.05). The FEV1 recovery rate one month after surgery was significantly better in the PR (101.6%; P < 0.001) than in the non-PR group (93.9%). In logistic regression analysis, predicted postoperative FEV1 , predicted postoperative %FEV1 , and PR were independent factors related to postoperative pulmonary complications after pulmonary lobectomy (odds ratio 18.9, 16.1, and 13.9, respectively; P < 0.05). CONCLUSIONS: PR improved the recovery rate of pulmonary function after lobectomy in the early period, and may decrease postoperative pulmonary complications.
Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/cirugía , Neoplasias Pulmonares/cirugía , Complicaciones Posoperatorias/epidemiología , Enfermedad Pulmonar Obstructiva Crónica/rehabilitación , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/fisiopatología , Comorbilidad , Femenino , Humanos , Incidencia , Neoplasias Pulmonares/fisiopatología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/prevención & control , Puntaje de Propensión , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Pruebas de Función Respiratoria , Estudios RetrospectivosRESUMEN
The purpose of this study was to compare postcontraction hyperemia after electrical stimulation between patients with upper extremity paralysis caused by upper motor neuron diseases and healthy controls. Thirteen healthy controls and eleven patients with upper extremity paralysis were enrolled. The blood flow in the basilic vein was measured by ultrasound before the electrical stimulation of the biceps brachii muscle and 30 s after the stimulation. The stimulation was performed at 10 mA and at a frequency of 70 Hz for 20 s. The mean blood flow in the healthy control group and in upper extremity paralysis group before the electrical stimulation was 60 ± 20 mL/min (mean ± SD) and 48 ± 25 mL/min, respectively. After the stimulation, blood flow in both groups increased to 117 ± 23 mL/min and 81 ± 41 mL/min, respectively. We show that it is possible to measure postcontraction hyperemia using an ultrasound system. In addition, blood flow in both groups increased after the electrical stimulation because of postcontraction hyperemia. These findings suggest that evaluating post contraction hyperemia in patients with upper extremity paralysis can assess rehabilitation effects.
Asunto(s)
Estimulación Eléctrica , Hiperemia/fisiopatología , Contracción Muscular , Músculo Esquelético/irrigación sanguínea , Músculo Esquelético/fisiología , Brazo/irrigación sanguínea , Brazo/fisiopatología , Estudios de Casos y Controles , Terapia por Estimulación Eléctrica , Humanos , Músculo Esquelético/fisiopatología , Parálisis/etiología , Parálisis/fisiopatología , Parálisis/terapia , Flujo Sanguíneo RegionalRESUMEN
The purpose of this study was to investigate the impact of high-frequency peripheral nerve magnetic stimulation on the upper limb function. Twenty-five healthy adults (16 men and 9 women) participated in this study. The radial nerve of the non-dominant hand was stimulated by high-frequency magnetic stimulation device. A total of 600 impulses were applied at a frequency of 20 Hz and intensity of 1.2 resting motor threshold (rMT). At three time points (before, immediately after, and 15 min after stimulation), muscle hardness of the extensor digitorum muscle on the stimulated side was measured using a mechanical tissue hardness meter and a shear wave imaging device, cephalic venous blood flow on the stimulated side was measured using an ultrasound system, and the Box and Block test (BBT) was performed. Mechanical tissue hardness results did not show any significant differences between before, immediately after, and 15 min after stimulation. Measurements via shear wave imaging showed that muscle hardness significantly decreased both immediately and 15 min after stimulation compared to before stimulation (P < 0.05). Peripheral venous blood flow and BBT score significantly increased both immediately and 15 min after stimulation compared to before stimulation (P < 0.01). High-frequency peripheral nerve magnetic stimulation can achieve effects similar to electrical stimulation in a less invasive manner, and may therefore become an important element in next-generation rehabilitation.
Asunto(s)
Brazo/fisiología , Magnetoterapia , Músculo Esquelético/fisiología , Adulto , Brazo/irrigación sanguínea , Femenino , Humanos , Masculino , Actividad Motora , Contracción Muscular , Músculo Esquelético/irrigación sanguínea , Flujo Sanguíneo RegionalRESUMEN
OBJECTIVE: To investigate the patterns of gait and locomotion in three dimension space in patients with vestibular disorders. METHODS: A 3D motion analysis system was employed to evaluate locomotor pattern and body's oscillation during gait under different conditions (normal, slow, fast speeds walking with eye open and normal speed walking with eyes closed) of nine patients with vestibular disorders. Twenty-one markers placed on the subject to record kinematics and locomotions of the head, spine and pelvis segments while walking. For each locomotor trial, the walking speed, locomotor patterns as well as the absolute angular dispersions of six segments around the roll, pitch and yaw axes were calculated to assess the equilibrium strategies of head, trunk and pelvis. Data was also recorded in 10 healthy subjects as control. RESULTS: Patients' cadence is faster, and the stride time at normal walking speed is shorter than that of the controls (p<0.05). The body sway has also been documented some impairment in patients. With respect to the control, patients' oscillation of trunk around yaw axis at fast speed is less (p<0.05), which means the patient seems need less shoulder torsional movement. Moreover, the most prominent changes in patients are the sway of hip in roll, which is significant less than controls at fast (p<0.01), slow speed (p<0.01) and in eye-closed condition (p<0.05). CONCLUSION: Our investigation corroborates those reports that higher velocities would be helpful for the increased gait stability in patients with vestibular disorders. And the body always try to keep the stability of head during gait, even under vestibular deficit conditions.
Asunto(s)
Marcha/fisiología , Movimiento/fisiología , Enfermedades Vestibulares/fisiopatología , Adulto , Anciano , Análisis de Varianza , Estudios de Casos y Controles , Femenino , Humanos , Locomoción/fisiología , Masculino , Persona de Mediana Edad , Propiocepción , Adulto JovenRESUMEN
We have previously restored ambulation in paraplegics by performing hybrid functional electrical stimulation (FES) with medial linkage knee-ankle-foot orthosis (MLKAFO). The most common MLKAFO (hinge-type MLKAFO) has the hypothetical axis that is lower than the physiological hip joint position, resulting in slow velocity and short step length. A new MLKAFO (sliding-type MLKAFO), which uses sliding medial linkages, has been developed to correct the axial discrepancy of the hinge-type MLKAFO that causes limited hip joint excursion. There have been reports of instability associated with sliding medial linkages, but the mechanism of this instability is unclear. The purpose of the present study was to evaluate the effects of FES with MLKAFOs on ambulation in paraplegics. Two complete paraplegic patients (levels T8 and T12, respectively) participated in this study. Kinematics data during ambulation were obtained using a motion analysis system. We measured gait velocity and hip progression during the standing phase. The sliding-type MLKAFO produced faster gait velocity than did the hinge-type MLKAFO, but it caused pelvis instability without FES. Pelvis instability was controlled by hybrid FES using the sliding-type MLKAFO. With hybrid FES, the sliding-type MLKAFO provides better gait performance than the hinge-type MLKAFO, but the hinge-type MLKAFO provides greater pelvis stability during walking. Moreover, FES provides sufficient propulsion to allow the complete paraplegics to walk.
Asunto(s)
Estimulación Eléctrica , Aparatos Ortopédicos , Paraplejía/rehabilitación , Andadores , Adulto , Articulación del Tobillo/fisiopatología , Diseño de Equipo , Marcha , Humanos , Articulación de la Rodilla/fisiopatología , Masculino , Paraplejía/fisiopatologíaRESUMEN
The subjects in this study were ten patients with accessory nerve palsy after radical neck dissection. All the primary diseases that accounted for radical neck dissection were malignant tumors located at the head or neck. Every patient received occupational therapy and underwent evaluations before and after the therapy. The data we collected included the existence of resting pain and motion pain, and the active and passive range of motion during shoulder flexion and abduction. The occupational therapy programs were not adequately effective for resting and motion pain, however, every patient gained independence for activities of daily living and housekeeping activities. The occupational therapy significantly improved the patient's shoulder elevation in all movements; although, the active abduction was always significantly poor compared with flexion. In the meantime, there were no significant differences between passive shoulder flexion and abduction at all times. We can therefore understand that the accessory nerve palsy especially affects active shoulder abduction induced by the trapezius paralysis. Occupational therapy is an effective treatment for the improvement of shoulder function, however, the occupational therapy has limited effectiveness for coping with the pain.
Asunto(s)
Enfermedades del Nervio Accesorio/rehabilitación , Disección del Cuello/efectos adversos , Terapia Ocupacional , Enfermedades del Nervio Accesorio/etiología , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Manejo del Dolor , Complicaciones PosoperatoriasRESUMEN
Grasping power (GP) by means of functional electrical stimulation (FES) was measured in a case of C6 complete tetraplegia. This was compared with GP by means of the dynamic tenodesis effect, the flexor hinge splint and the GP of normal female. Palmar grasp strength by means of FES was approximately 16% of the control group and 2.4 times greater than the flexor hinge splint. Lateral grasp strength by FES was approximately 13% of the control group. Our results suggest that FES is more effective than the flexor hinge splint in increasing the GP of tetraplegic patients, and that a stronger and stable GP, which is not affected by wrist position, makes FES practical for improving activities of daily living (ADL).