Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiothorac Vasc Anesth ; 35(9): 2626-2630, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33334649

RESUMEN

OBJECTIVES: Balloon postdilation (BPD) is one strategy for decreasing paravalvular leakage, but its effect on long-term mortality remains unclear. The authors sought to clarify whether BPD influences long-term mortality of patients with transcatheter aortic valve replacement (TAVR). DESIGN: Single-center retrospective study. SETTING: National heart center; single institution. PARTICIPANTS: Participants were patients who underwent TAVR in the authors' hospital from January 2014 to December 2016. A balloon-expandable Sapien XT or Sapien3, or self-expandable CoreValve or Evolute R, was implanted according to the decision of the surgeon considering degree of calcification of the aortic valve. INTERVENTIONS: No interventions. MEASUREMENTS AND MAIN RESULTS: Multivariate Cox regression analysis and inverse probability weighted estimation were performed using a propensity score to examine whether BPD influenced six-year mortality. Ultimately, 180 patients were analyzed. During the follow-up period, with a median of 1104 (interquartile range: 730-1463) days, 41 patients died and cumulative incidence of mortality at six years was 22.8%. Society of Thoracic Surgeons score (odds ratio [OR]: 2.257, 95% CI: 1.213-4.197, p = 0.010)], BPD (OR: 0.306, 95% CI: 0.098-0.953, p = 0.041), and paravalvular regurgitation of at least moderate-to-mild severity after deploying (OR: 5.407, 95% CI: 1.626-17.978, p = 0.006) were significant factors of mortality. CONCLUSIONS: BPD is associated with reduced six-year mortality.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
J Surg Case Rep ; 2021(10): rjab420, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34667589

RESUMEN

The Impella (Abiomed, Danvers, MA, USA) is a minimally invasive axial-flow catheter used in severe heart failure. We describe a case in which aortic insufficiency occurred after Impella insertion, required extra surgical intervention twice. A 33-year-old man with familial dilated cardiomyopathy was admitted to our hospital due to acute decompensation of heart failure. Despite intensive medical treatment, his hemodynamic status did not improve. Firstly, Impella was emergently implanted, and HeartMate III (Abbott, Plymouth, MN, USA) implantation was performed 2 weeks after. In the HeartMate III implantation, new aortic insufficiency had revealed and central aortic valve closure was performed concomitantly. However, on postoperative Day1, the coaptation stitch had untied, causing severe aortic insufficiency which led to another emergent operation of aortic valve replacement. We suggest that indications for Impella implantation need to be carefully discussed beforehand, especially with patients who may undergo implantation of left ventricular assist device.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA