Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Radiology ; 312(2): e233039, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-39105637

RESUMEN

Background Clinical decision making and drug development for fibrostenosing Crohn disease is constrained by a lack of imaging definitions, scoring conventions, and validated end points. Purpose To assess the reliability of MR enterography features to describe Crohn disease strictures and determine correlation with stricture severity. Materials and Methods A retrospective study of patients with symptomatic terminal ileal Crohn disease strictures who underwent MR enterography at tertiary care centers (Cleveland Clinic: September 2013 to November 2020; Mayo Clinic: February 2008 to March 2019) was conducted by using convenience sampling. In the development phase, blinded and trained radiologists independently evaluated 26 MR enterography features from baseline and follow-up examinations performed more than 6 months apart, with no bowel resection performed between examinations. Follow-up examinations closest to 12 months after baseline were selected. Reliability was assessed using the intraclass correlation coefficient (ICC). In the validation phase, after five features were redefined, reliability was re-estimated in an independent convenience sample using baseline examinations. Multivariable linear regression analysis identified features with at least moderate interrater reliability (ICC ≥0.41) that were independently associated with stricture severity. Results Ninety-nine (mean age, 40 years ± 14 [SD]; 50 male) patients were included in the development group and 51 (mean age, 45 years ± 16 [SD]; 35 female) patients were included in the validation group. In the development group, nine features had at least moderate interrater reliability. One additional feature demonstrated moderate reliability in the validation group. Stricture length (ICC = 0.85 [95% CI: 0.75, 0.91] and 0.91 [95% CI: 0.75, 0.96] in development and validation phase, respectively) and maximal associated small bowel dilation (ICC = 0.74 [95% CI: 0.63, 0.80] and 0.73 [95% CI: 0.58, 0.87] in development and validation group, respectively) had the highest interrater reliability. Stricture length, maximal stricture wall thickness, and maximal associated small bowel dilation were independently (regression coefficients, 0.09-3.97; P < .001) associated with stricture severity. Conclusion MR enterography definitions and scoring conventions for reliably assessing features of Crohn disease strictures were developed and validated, and feature correlation with stricture severity was determined. © RSNA, 2024 Supplemental material is available for this article. See also the article by Rieder and Ma et al in this issue. See also the editorial by Galgano and Summerlin in this issue.


Asunto(s)
Enfermedad de Crohn , Imagen por Resonancia Magnética , Humanos , Enfermedad de Crohn/diagnóstico por imagen , Femenino , Masculino , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Adulto , Reproducibilidad de los Resultados , Constricción Patológica/diagnóstico por imagen , Persona de Mediana Edad
2.
Radiographics ; 44(9): e230148, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39207924

RESUMEN

Multiple infiltrative disorders can affect the small bowel, often resulting in diffuse small bowel wall thickening. These infiltrative disorders can manifest owing to various factors such as an influx of immunologic or neoplastic cells or the accumulation of substances within one or more layers of the intestinal wall. Although there can be considerable overlap in the appearances of infiltrative diseases on cross-sectional images, a comprehensive understanding of more specific ancillary imaging features and clinicopathologic correlation can substantially narrow the differential diagnosis. The radiologist can be instrumental in synthesizing the clinical and imaging information and guiding subsequent workup. The authors present a comprehensive review of the infiltrative disorders that commonly involve the small bowel. These disorders are organized on the basis of their pathophysiologic features, with multiple illustrative case examples to enhance understanding of these entities. CT and MRI are currently the most commonly used imaging modalities for evaluating small bowel disorders, and this review is focused on these two modalities. Detailed information regarding the pathologic features, clinical presentation, and imaging findings of these infiltrative disorders is provided to aid radiologists in recognizing and differentiating these conditions. ©RSNA, 2024.


Asunto(s)
Enfermedades Intestinales , Intestino Delgado , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Humanos , Intestino Delgado/diagnóstico por imagen , Intestino Delgado/patología , Diagnóstico Diferencial , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Enfermedades Intestinales/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Adulto
3.
AJR Am J Roentgenol ; 220(1): 73-85, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35731096

RESUMEN

BACKGROUND. Anatomic redundancy between phases can be used to achieve denoising of multiphase CT examinations. A limitation of iterative reconstruction (IR) techniques is that they generally require use of CT projection data. A frequency-split multi-band-filtration algorithm applies denoising to the multiphase CT images themselves. This method does not require knowledge of the acquisition process or integration into the reconstruction system of the scanner, and it can be implemented as a supplement to commercially available IR algorithms. OBJECTIVE. The purpose of the present study is to compare radiologists' performance for low-contrast and high-contrast diagnostic tasks (i.e., tasks for which differences in CT attenuation between the imaging target and its anatomic background are subtle or large, respectively) evaluated on multiphase abdominal CT between routine-dose images and radiation dose-reduced images processed by a frequency-split multiband-filtration denoising algorithm. METHODS. This retrospective single-center study included 47 patients who underwent multiphase contrast-enhanced CT for known or suspected liver metastases (a low-contrast task) and 45 patients who underwent multiphase contrast-enhanced CT for pancreatic cancer staging (a high-contrast task). Radiation dose-reduced images corresponding to dose reduction of 50% or more were created using a validated noise insertion technique and then underwent denoising using the frequency-split multi-band-filtration algorithm. Images were independently evaluated in multiple sessions by different groups of abdominal radiologists for each task (three readers in the low-contrast arm and four readers in the high-contrast arm). The noninferiority of denoised radiation dose-reduced images to routine-dose images was assessed using the jackknife alternative free-response ROC (JAFROC) figure-of-merit (FOM; limit of noninferiority, -0.10) for liver metastases detection and using the Cohen kappa statistic and reader confidence scores (100-point scale) for pancreatic cancer vascular invasion. RESULTS. For liver metastases detection, the JAFROC FOM for denoised radiation dose-reduced images was 0.644 (95% CI, 0.510-0.778), and that for routine-dose images was 0.668 (95% CI, 0.543-0.792; estimated difference, -0.024 [95% CI, -0.084 to 0.037]). Intraobserver agreement for pancreatic cancer vascular invasion was substantial to near perfect when the two image sets were compared (κ = 0.53-1.00); the 95% CIs of all differences in confidence scores between image sets contained zero. CONCLUSION. Multiphase contrast-enhanced abdominal CT images with a radiation dose reduction of 50% or greater that undergo denoising by a frequency-split multiband-filtration algorithm yield performance similar to that of routine-dose images for detection of liver metastases and vascular staging of pancreatic cancer. CLINICAL IMPACT. The image-based denoising algorithm facilitates radiation dose reduction of multiphase examinations for both low- and high-contrast diagnostic tasks without requiring manufacturer-specific hardware or software.


Asunto(s)
Neoplasias Hepáticas , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
4.
Radiographics ; 42(4): 1081-1102, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35749291

RESUMEN

Eosinophilic gastrointestinal disorders (EGIDs) are inflammatory conditions of the gastrointestinal tract that are characterized by tissue eosinophilia and end-organ dysfunction or damage. Primary EGIDs are associated with atopy and other allergic conditions, whereas secondary EGIDs are associated with underlying systemic diseases or hypereosinophilic syndrome. Within the spectrum of EGIDs, eosinophilic esophagitis is the most prevalent. Eosinophilic gastroenteritis and eosinophilic colitis are relatively uncommon. Eosinophilic infiltration of the liver, biliary tree, and/or pancreas also can occur and mimic other inflammatory and malignant conditions. Although endoscopic evaluation is the method of choice for eosinophilic esophagitis, radiologic evaluation of the esophagus plays an important role in the assessment of disease severity. CT and MR enterography are the modalities of choice for demonstrating specific forms of eosinophilic gastroenteritis. CT and MRI are important in the detection of abdominal visceral involvement in EGIDs. Diagnosis is often challenging and relies on symptoms, imaging findings, histologic confirmation of tissue eosinophilia, and correlation with peripheral eosinophilia. Imaging is crucial for identifying characteristic organ-specific findings, although imaging findings are not specific. When promptly treated, EGIDs usually have a benign clinical course. However, a delayed diagnosis and associated surgical interventions have been associated with morbidity. Therefore, a radiologist's knowledge of the imaging findings of EGIDs in the appropriate clinical settings may aid in early diagnosis and thereby improve patient care. An overview of the clinical features and imaging findings of EGIDs and the eosinophilic disorders of associated abdominal viscera is provided. Online supplemental material is available for this article. ©RSNA, 2022.


Asunto(s)
Enteritis , Esofagitis Eosinofílica , Enteritis/complicaciones , Enteritis/diagnóstico por imagen , Eosinofilia , Esofagitis Eosinofílica/diagnóstico , Esofagitis Eosinofílica/terapia , Gastritis , Humanos , Vísceras
5.
Radiographics ; 42(7): 2014-2036, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36206184

RESUMEN

The motor function of the gastrointestinal tract relies on the enteric nervous system, which includes neurons spanning from the esophagus to the internal anal sphincter. Disorders of gastrointestinal motility arise as a result of disease within the affected portion of the enteric nervous system and may be caused by a wide array of underlying diseases. The etiology of motility disorders may be primary or due to secondary causes related to infection or inflammation, congenital abnormalities, metabolic disturbances, systemic illness, or medication-related side effects. The symptoms of gastrointestinal dysmotility tend to be nonspecific and may cause diagnostic difficulty. Therefore, evaluation of motility disorders requires a combination of clinical, radiologic, and endoscopic or manometric testing. Radiologic studies including fluoroscopy, CT, MRI, and nuclear scintigraphy allow exclusion of alternative pathologic conditions and serve as adjuncts to endoscopy and manometry to determine the appropriate diagnosis. Additionally, radiologist understanding of clinical evaluation of motility disorders is necessary for guiding referring clinicians and appropriately imaging patients. New developments and advances in imaging techniques have allowed improved assessment and diagnosis of motility disorders, which will continue to improve patient treatment options. Online supplemental material is available for this article. ©RSNA, 2022.


Asunto(s)
Enfermedades Gastrointestinales , Motilidad Gastrointestinal , Humanos , Manometría/métodos , Motilidad Gastrointestinal/fisiología , Esófago , Diagnóstico por Imagen
6.
J Magn Reson Imaging ; 49(5): 1236-1252, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30609194

RESUMEN

Use of gadoxetate disodium, a hepatobiliary gadolinium-based agent, in patients with chronic parenchymal liver disease offers the advantage of improved sensitivity for detecting hepatocellular carcinoma (HCC). Imaging features of liver observations on gadoxetate-enhanced MRI may also serve as biomarkers of recurrence-free and overall survival following definitive treatment of HCC. A number of technical and interpretative pitfalls specific to gadoxetate exist, however, and needs to be recognized when protocoling and interpreting MRI exams with this agent. This article reviews the advantages and pitfalls of gadoxetate use in patients at risk for HCC, and the potential impact on Liver Imaging Reporting and Data System (LI-RADS) imaging feature assessment and categorization. Level of Evidence: 5 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019;49:1236-1252.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Gadolinio DTPA , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sistemas de Información Radiológica/estadística & datos numéricos , Humanos , Hígado/diagnóstico por imagen
7.
Radiology ; 286(1): 158-172, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28853673

RESUMEN

Purpose To evaluate the diagnostic performance and interrater reliability of the Liver Imaging Reporting and Data System (LI-RADS) version 2014 in differentiating hepatocellular carcinoma (HCC) from non-HCC malignancy in a population of patients at risk for HCC. Materials and Methods This retrospective HIPAA-compliant institutional review board-approved study was exempt from informed consent. A total of 178 pathology-proven malignant liver masses were identified in 178 patients at risk for HCC but without established extrahepatic malignancy from August 2012 through August 2015. Two readers blinded to pathology findings and clinical follow-up data independently evaluated a liver protocol magnetic resonance or computed tomography study for each lesion and assigned LI-RADS categories, scoring all major and most ancillary features. Statistical analyses included the independent samples t test, x2 test, Fisher exact test, and Cohen k. Results This study included 136 HCCs and 42 non-HCC malignancies. Specificity and positive predictive value of an HCC imaging diagnosis (LR-5 or LR-5V) were 69.0% and 90.5%, respectively, for reader 1 (R1) and 88.3% and 95.5%, respectively, for reader 2 (R2). Tumor in vein was a common finding in patients with non-HCC malignancies (R1, 10 of 42 [23.8%]; R2, five of 42 [11.9%]). Exclusion of the LR-5V pathway improved specificity and positive predictive value for HCC to 83.3% and 92.9%, respectively, for R1 (six fewer false-positive findings) and 92.3% and 96.4%, respectively, for R2 (one fewer false-positive finding). Among masses with arterial phase hyperenhancement, the rim pattern was more common among non-HCC malignancies than among HCCs for both readers (R1: 24 of 36 [66.7%] vs 13 of 124, [10.5%], P < .001; R2: 27 of 35 [77.1%] vs 21 of 123 [17.1%], P < .001) (k = 0.76). Exclusion of rim arterial phase hyperenhancement as a means of satisfying LR-5 criteria also improved specificity and positive predictive value for HCC (R1, two fewer false-positive findings). Conclusion Modification of the algorithmic role of tumor in vein and rim arterial phase hyperenhancement improves the diagnostic performance of LI-RADS version 2014 in differentiating HCC from non-HCC malignancy. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/normas , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Adulto Joven
9.
AJR Am J Roentgenol ; 207(1): 25-31, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26866746

RESUMEN

OBJECTIVE: The purpose of this study was to determine the frequency with which biphenotypic primary liver carcinoma (also called hepatocholangiocarcinoma) may be misclassified as hepatocellular carcinoma (HCC) when only Liver Imaging Reporting and Data System (LI-RADS) major features are used and after consideration of ancillary features. MATERIALS AND METHODS: A review of all pathologically proven biphenotypic primary liver carcinomas diagnosed at one institution from 2006 to 2014 was performed. Two subspecialized abdominal imagers independently reviewed cases using LI-RADS version 2014 and assigned major features, ancillary features, and additional findings. The number of lesions meeting imaging criteria for HCC was determined after assessment of major features alone and after the addition of ancillary features. RESULTS: Sixty-one patients (30 men, 31 women; mean age, 62 years; range, 22-89 years) with biphenotypic primary liver carcinomas who underwent pretreatment multiphasic contrast-enhanced MRI (48 patients) or CT (13 patients) were included. According to LI-RADS major features alone, 33 (54.1%) lesions met criteria for HCC and therefore might have been misclassified. Thirteen had arterial phase hyperenhancement, washout, and a capsule. Twenty had arterial phase hyperenhancement with either washout (15 lesions) or a capsule (five lesions). After evaluation of ancillary features, 29 of these potential mimics exhibited at least one ancillary feature favoring non-HCC malignancy, possibly leading to appropriate reclassification. Of the four carcinomas that met criteria for HCC by major features and did not have ancillary features favoring non-HCC malignancy, two (3.3% of all tumors) fell within the Milan criteria. CONCLUSION: Most biphenotypic primary liver carcinomas have features of non-HCC malignancy and can be correctly categorized as such. Addition of ancillary features to major features may improve diagnostic accuracy over systems in which only major features are used.


Asunto(s)
Colangiocarcinoma/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/patología , Colangiocarcinoma/patología , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Fenotipo
10.
Abdom Imaging ; 40(6): 1666-74, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25488345

RESUMEN

OBJECTIVE: To determine the effectiveness of the CT histogram method to characterize indeterminate adrenal nodules above 10 Hounsfield units (HU) on noncontrast CT. MATERIALS AND METHODS: Retrospective review of clinical CT data from January 2005 through 2008 identified 194 indeterminate adrenal nodules (>10 HU on noncontrast CT) in 175 patients. 20 nodules in 18 patients were excluded due to large standard deviation (SD > 30) of HU values. Of the remaining 174 nodules, 131 were classified as benign lipid-poor nodules based on size stability for ≥1 year (104), in- and opposed-phase MRI (17), adrenal washout CT (3), or biopsy (7). 43 were classified as malignant by size increase over a short time (30), avid FDG uptake on PET/CT (15), or biopsy (5). Histogram analysis was performed by drawing a circular region of interest on all adrenal nodules. Mean attenuation, total number of pixels, number of negative pixels, and percentage of negative pixels were recorded for each nodule. RESULTS: At the threshold value of >10% negative pixels, 59/131 benign nodules were correctly characterized, but 1/43 malignant nodules was falsely characterized as benign (sensitivity 45%, specificity 98%, positive predictive value 98%). With a slightly higher threshold value of >15% negative pixels, there were no false benign judgments. 36 nodules had more than 15% negative pixels, all of which were benign (sensitivity 27%, specificity 100%, positive predictive value 100%). In the subgroup of benign nodules measuring 11-20 HU, 80% and 54% were identified with threshold values of >10% and >15% negative pixels, respectively. CONCLUSION: The CT histogram method with a threshold value of >10% negative pixels can identify many benign adrenal nodules with attenuation values >10 HU on unenhanced CT with extremely high specificity. A threshold of >15% negative pixels can achieve 100% specificity. This method is highly robust provided very "noisy" CT examinations (SD > 30) are eliminated.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Glándulas Suprarrenales/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
11.
Abdom Imaging ; 40(3): 613-25, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25287679

RESUMEN

The Liver Imaging Reporting and Data System (LI-RADS) was introduced with the goal of standardizing the diagnosis of hepatocellular carcinoma. The 2014 version of LI-RADS incorporates the use of hepatobiliary contrast agents (HBAs) into the diagnostic algorithm, including gadoxetate disodium and gadobenate dimeglumine. Three new ancillary features are introduced: hepatobiliary phase (HBP) hypointensity and HBP hypointense rim favor malignancy, while HBP isointensity favors benignity. HBP hyperintensity favors neither malignancy nor benignity. In this review, we describe how to use these new features as well as numerous pitfalls associated with the use ofHBAs, including hemangiomas, cholangiocarcinomas, and focal confluent fibrosis. Importantly, findings on the HBP are not included as major criteria and therefore the criteria for the diagnosis of LI-RADS 5 observations remain unchanged, and so congruence with the Organ Procurement Transplant Network system remains intact. Additionally, we review how the major features in LI-RADS, arterial phase hyperenhancement, threshold growth, and washout and capsule appearance, may be affected with HBAs. Notably with HBAs, hypointensity on the delayed phase, termed the transitional phase, does not qualify as washout appearance due to the possibility of early parenchymal enhancement. It is hoped that the incorporation of HBAs into LI-RADS will help create consistency when interpreting HBA enhanced MRIs.


Asunto(s)
Algoritmos , Carcinoma Hepatocelular/diagnóstico , Medios de Contraste , Gadolinio DTPA , Neoplasias Hepáticas/diagnóstico , Carcinoma Hepatocelular/irrigación sanguínea , Humanos , Aumento de la Imagen , Hígado/irrigación sanguínea , Neoplasias Hepáticas/irrigación sanguínea
12.
AJR Am J Roentgenol ; 203(6): W614-22, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25415726

RESUMEN

OBJECTIVE: The purpose of this study was to determine the prevalence of nonpolypoid adenomas and the sensitivity of CT colonography (CTC) in their detection by use of the restricted criteria of height-to-width ratio<50% and height elevation≤3 mm. MATERIALS AND METHODS: In the National CT Colonography Trial (American College of Radiology Imaging Network protocol 6664), a cohort of 2531 participants without symptoms underwent CTC and screening colonoscopy. The CTC examinations were interpreted with both 2D and 3D techniques. Nonpolypoid adenomatous polyps identified with CTC or colonoscopy were retrospectively reviewed to determine which polyps met the restricted criteria. The prevalence of nonpolypoid adenomas and the prospective sensitivity of CTC were determined. Descriptive statistics were used to report the prevalence, size, and histologic features. The sensitivities (with 95% CIs) for nonpolypoid and polypoid lesions were compared by two-sided Z test for independent binomial proportions. RESULTS: The retrospective review confirmed 21 nonpolypoid adenomas, yielding a prevalence of 0.83% (21 of 2531 participants). Eight (38.1%) were advanced adenomas, many (50% [4/8]) only because of large size (≥10 mm). The overall per polyp sensitivity of CTC (combined 2D and 3D interpretation) for detecting nonpolypoid adenomas≥5 mm (n=21) was 0.76; ≥6 mm (n=16), 0.75; and ≥10 mm (n=5), 0.80. These values were not statistically different from the sensitivity of detecting polypoid adenomas (p>0.37). CONCLUSION: In this large screening population, nonpolypoid adenomas had a very low prevalence (<1%), and advanced pathologic features were uncommon in polyps<10 mm in diameter. Most nonpolypoid adenomas are technically visible at CTC. The prospective sensitivity is similar to that for polypoid adenomas when the interpretation combines both 2D and 3D review.


Asunto(s)
Adenoma/diagnóstico por imagen , Adenoma/epidemiología , Neoplasias del Colon/diagnóstico por imagen , Neoplasias del Colon/epidemiología , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/epidemiología , Colonografía Tomográfica Computarizada/normas , Anciano , Anciano de 80 o más Años , Colonografía Tomográfica Computarizada/métodos , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Prevalencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos/epidemiología
13.
Abdom Radiol (NY) ; 49(2): 375-383, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38127281

RESUMEN

PURPOSE: The purpose of this study is to determine computed tomography (CT) findings that aid in differentiating idiopathic myointimal hyperplasia of mesenteric veins (IMHMV) from other colitides. METHODS: Retrospective review of histiologic proven cases of IMHMV (n = 12) with contrast enhanced CT (n = 11) and/or computed tomography angiography (CTA) (n = 9) exams. Control groups comprised of CT of infectious colitis (n = 13), CT of inflammatory bowel disease (IBD) (n = 12), and CTA of other colitides (n = 13). CT exams reviewed by 2 blinded gastrointestinal radiologists for maximum bowel wall thickness, enhancement pattern, decreased bowel wall enhancement, submucosal attenuation value, presence and location of IMV occlusion, peripheral mesenteric venous occlusion, dilated pericolonic veins, subjective IMA dilation, maximum IMA diameter, maximum peripheral IMA branch diameter, ascites, and mesenteric edema. Presence of early filling veins was an additional finding evaluated on CTA exams. RESULTS: Statistically significant CT findings of IMHMV compared to control groups included greater maximum bowel wall thickness, decreased bowel enhancement, IMV occlusion, and peripheral mesenteric venous occlusion (p < 0.05). Dilated pericolonic veins were seen more frequently in IMHMV compared to the infectious colitis group (64% versus 15%, p = 0.02). Additional statistically significant finding on CTA included early filling veins in IMHMV compared to the CTA control group (100% versus 46%, p = 0.008). CONCLUSION: IMHMV is a rare chronic non-thrombotic ischemia predominantly involving the rectosigmoid colon. CT features that may aid in differentiating IMHMV from other causes of left-sided colitis include marked bowel wall thickening with decreased enhancement, IMV and peripheral mesenteric venous occlusion or tapering, and early filling of dilated veins on CTA.


Asunto(s)
Colitis , Enfermedades Vasculares , Humanos , Hiperplasia/diagnóstico por imagen , Hiperplasia/patología , Venas Mesentéricas/diagnóstico por imagen , Venas Mesentéricas/patología , Colitis/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Enfermedades Vasculares/patología
14.
Jpn J Radiol ; 41(4): 409-416, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36401061

RESUMEN

OBJECTIVES: To describe the prevalence, clinical and radiological findings of biliary prolapse in pathologically proven mucinous cystic neoplasm of the liver (MCN-L). METHODS: Thirty-four patients, all female with median age 50 years (range, 14-82), with histologically confirmed MCN-L were enrolled. Median tumor size was 9 cm (range, 2-21 cm). Fifty-seven examinations (17 ultrasound, 25 CT, and 15 MR) among 34 MCN-Ls were reviewed. Two radiologists retrospectively assessed images for tumor location, size and other morphological features of the tumor, presence of biliary prolapse and upstream bile duct dilatation. Ultrasound, CT, and MR were assessed separately. Clinical features were evaluated. Clinical and radiological characteristics of MCN-L with and without biliary prolapse were compared. RESULTS: 15% (5/34) of MCN-Ls showed biliary prolapse confirmed at pathology. None of MCN-Ls were associated with invasive carcinoma. Patients with biliary prolapse were significantly younger than those without (median 27 years [22-56] vs. median 51 years [14-82], p = 0.03). MCN-Ls with biliary prolapse were significantly smaller than those without (median 6.4 cm [2.2-7.5] vs. median 9.6 cm [3.1-21], p = 0.01). The upstream bile duct was dilated more frequently in MCN-Ls with biliary prolapse (100% vs. 38%, p = 0.02). Jaundice was significantly more common in MCN-Ls with biliary prolapse (80 vs 3%, p = 0.0005). Other clinical or radiological features were not significantly different between two groups. CONCLUSIONS: Biliary prolapse was found in 15% of MCN-Ls. MCN-Ls with biliary prolapse were significantly smaller and were more commonly associated with upstream bile duct dilation and jaundice than those without biliary prolapse.


Asunto(s)
Neoplasias de los Conductos Biliares , Neoplasias Hepáticas , Neoplasias Quísticas, Mucinosas y Serosas , Humanos , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Neoplasias Quísticas, Mucinosas y Serosas/complicaciones , Neoplasias Hepáticas/patología , Prolapso , Neoplasias de los Conductos Biliares/patología
15.
Eur J Radiol Open ; 11: 100519, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37609047

RESUMEN

Purpose: To assess the feasibility of the 6-point Dixon method for evaluating liver masses. We also report our initial experience with the quantitative values in various liver masses on a 3T system. Materials and methods: Of 251 consecutive patients for whom 6-point Dixon was employed in abdominal magnetic resonance imaging scans between October 2020 and October 2021, 117 nodules in 117 patients with a mass diameter of more than 1 cm were included in the study. Images for measuring the proton density fat fraction (PDFF) and R2 * values were obtained using the iterative decomposition of water and fat with echo asymmetry and least-squares estimation-quantitative technique for liver imaging. Two radiologists independently measured PDFF (%) and R2 * (Hz). Inter-reader agreement and the differences between readers were examined using intra-class correlation coefficient (ICC) and the Bland-Altman method, respectively. PDFF and R2 * values in differentiating liver masses were examined. Results: The masses included hepatocellular carcinoma (n = 59), cyst (n = 20), metastasis (n = 14), hemangioma (n = 8), and others (n = 16). The ICCs for the region of interest (mm2), PDFF, and R2 * were 0.988 (95 % confidence interval (CI): 0.983, 0.992), 0.964 (95 % CI: 0.949, 0.975), and 0.962 (95 % CI: 0.941, 0.975), respectively. The differences of measurements between the readers showed that 5.1 % (6/117) and 6.0% (7/117) for PDFF and R2 * , respectively, were outside the 95 % CI. Conclusion: Our observation indicates that the 6-point Dixon method is applicable to liver masses.

16.
Radiology ; 263(2): 401-8, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22361006

RESUMEN

PURPOSE: To conduct post-hoc analysis of National CT Colonography Trial data and compare the sensitivity and specificity of computed tomographic (CT) colonography in participants younger than 65 years with those in participants aged 65 years and older. MATERIALS AND METHODS: Of 2600 asymptomatic participants recruited at 15 centers for the trial, 497 were 65 years of age or older. Approval of this HIPAA-compliant study was obtained from the institutional review board of each site, and informed consent was obtained from each subject. Radiologists certified in CT colonography reported lesions 5 mm in diameter or larger. Screening detection of large (≥10-mm) histologically confirmed colorectal neoplasia was the primary end point; screening detection of smaller (6-9-mm) colorectal neoplasia was a secondary end point. The differences in sensitivity and specificity of CT colonography in the two age cohorts (age < 65 years and age ≥ 65 years) were estimated with bootstrap confidence intervals (CIs). RESULTS: Complete data were available for 477 participants 65 years of age or older (among 2531 evaluable participants). Prevalence of adenomas 1 cm or larger for the older participants versus the younger participants was 6.9% (33 of 477) versus 3.7% (76 of 2054) (P < .004). For large neoplasms, mean estimates for CT colonography sensitivity and specificity among the older cohort were 0.82 (95% CI: 0.644, 0.944) and 0.83 (95% CI: 0.779, 0.883), respectively. For large neoplasms in the younger group, CT colonography sensitivity and specificity were 0.92 (95% CI: 0.837, 0.967) and 0.86 (95% CI: 0.816, 0.899), respectively. Per-polyp sensitivity for large neoplasms for the older and younger populations was 0.75 (95% CI: 0.578, 0.869) and 0.84 (95% CI: 0.717, 0.924), respectively. For the older and younger groups, per-participant sensitivity was 0.72 (95% CI: 0.565, 0.854) and 0.81 (95% CI: 0.745, 0.882) for detecting adenomas 6 mm in diameter or larger. CONCLUSION: For most measures of diagnostic performance and in most subsets, the difference between senior-aged participants and those younger than 65 years was not statistically significant.


Asunto(s)
Colonografía Tomográfica Computarizada , Neoplasias Colorrectales/diagnóstico por imagen , Factores de Edad , Anciano , Anciano de 80 o más Años , Ensayos Clínicos como Asunto , Neoplasias Colorrectales/epidemiología , Femenino , Humanos , Imagenología Tridimensional , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Sensibilidad y Especificidad , Estados Unidos/epidemiología
17.
Med Phys ; 49(1): 70-83, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34792800

RESUMEN

PURPOSE: Conventional model observers (MO) in CT are often limited to a uniform background or varying background that is random and can be modeled in an analytical form. It is unclear if these conventional MOs can be readily generalized to predict human observer performance in clinical CT tasks that involve realistic anatomical background. Deep-learning-based model observers (DL-MO) have recently been developed, but have not been validated for challenging low contrast diagnostic tasks in abdominal CT. We consequently sought to validate a DL-MO for a low-contrast hepatic metastases localization task. METHODS: We adapted our recently developed DL-MO framework for the liver metastases localization task. Our previously-validated projection-domain lesion-/noise-insertion techniques were used to synthesize realistic positive and low-dose abdominal CT exams, using the archived patient projection data. Ten experimental conditions were generated, which involved different lesion sizes/contrasts, radiation dose levels, and image reconstruction types. Each condition included 100 trials generated from a patient cohort of 7 cases. Each trial was presented as liver image patches (160×160×5 voxels). The DL-MO performance was calculated for each condition and was compared with human observer performance, which was obtained by three sub-specialized radiologists in an observer study. The performance of DL-MO and radiologists was gauged by the area under localization receiver-operating-characteristic curves. The generalization performance of the DL-MO was estimated with the repeated twofold cross-validation method over the same set of trials used in the human observer study. A multi-slice Channelized Hoteling Observers (CHO) was compared with the DL-MO across the same experimental conditions. RESULTS: The performance of DL-MO was highly correlated to that of radiologists (Pearson's correlation coefficient: 0.987; 95% CI: [0.942, 0.997]). The performance level of DL-MO was comparable to that of the grouped radiologists, that is, the mean performance difference was -3.3%. The CHO performance was poorer than the grouped radiologist performance, before internal noise could be added. The correlation between CHO and radiologists was weaker (Pearson's correlation coefficient: 0.812, and 95% CI: [0.378, 0.955]), and the corresponding performance bias (-29.5%) was statistically significant. CONCLUSION: The presented study demonstrated the potential of using the DL-MO for image quality assessment in patient abdominal CT tasks.


Asunto(s)
Aprendizaje Profundo , Neoplasias Hepáticas , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias Hepáticas/diagnóstico por imagen , Variaciones Dependientes del Observador , Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X
18.
Aliment Pharmacol Ther ; 55(12): 1560-1568, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35274320

RESUMEN

BACKGROUND: Most patients experience good functional outcomes following ileal pouch-anal anastomosis (IPAA) for ulcerative colitis. AIM: We aimed to determine if asymptomatic patients with an IPAA had findings consistent with normal defecation on standard objective anorectal tests. METHODS: Patients 18-65 years old with IPAA and self-reported healthy pouch function were recruited. Patients with chronic pouchitis, Crohn's disease, anastomotic stricture, or indication for IPAA other than ulcerative or indeterminate colitis were excluded. Patients underwent an interview with an abbreviated Rome Questionnaire followed by high-resolution ano-pouch manometry, balloon expulsion test, pouch barostat, and magnetic resonance (MR) defecography. RESULTS: Twenty patients completed all testing. Six patients were excluded from the final analysis due to symptoms suggestive of pouch evacuation disorder on the abbreviated Rome Questionnaire (n = 2), structural abnormality on MR imaging (n = 3), or both (n = 1). Of the remaining 14 patients, mean anal resting pressure during high-resolution manometry was 72 ± 16 mmHg, mean anal squeeze pressure was 247 ± 69 mmHg, and mean pouch-anal gradient during the simulated evacuation was -27 ± 37 mmHg. The meantime to balloon expulsion was 54 seconds. During dynamic MR defecography, the mean descent of ano-pouch junction was 2.6 cm, and mean pouch evacuation was 44.5% and 74.2% pre- and posttoilet phase, respectively. CONCLUSIONS: A substantial proportion of patients with IPAA and self-reported healthy pouch function have anatomic and/or functional abnormalities of the pouch. In asymptomatic IPAA patients with an anatomically normal pouch, we have proposed normal parameters for high-resolution ano-pouch manometry, time to balloon expulsion, pouch barostat, and MR defecography.


Asunto(s)
Colitis Ulcerosa , Reservorios Cólicos , Reservoritis , Proctocolectomía Restauradora , Adolescente , Adulto , Anciano , Canal Anal/diagnóstico por imagen , Canal Anal/cirugía , Anastomosis Quirúrgica/efectos adversos , Reservorios Cólicos/efectos adversos , Humanos , Persona de Mediana Edad , Proyectos Piloto , Reservoritis/diagnóstico por imagen , Reservoritis/etiología , Proctocolectomía Restauradora/efectos adversos , Adulto Joven
19.
Inflamm Bowel Dis ; 28(11): 1677-1686, 2022 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-35032168

RESUMEN

BACKGROUND: We aimed to determine if patient symptoms and computed tomography enterography (CTE) and magnetic resonance enterography (MRE) imaging findings can be used to predict near-term risk of surgery in patients with small bowel Crohn's disease (CD). METHODS: CD patients with small bowel strictures undergoing serial CTE or MRE were retrospectively identified. Strictures were defined by luminal narrowing, bowel wall thickening, and unequivocal proximal small bowel dilation. Harvey-Bradshaw index (HBI) was recorded. Stricture observations and measurements were performed on baseline CTE or MRE and compared to with prior and subsequent scans. Patients were divided into those who underwent surgery within 2 years and those who did not. LASSO (least absolute shrinkage and selection operator) regression models were trained and validated using 5-fold cross-validation. RESULTS: Eighty-five patients (43.7 ± 15.3 years of age at baseline scan, majority male [57.6%]) had 137 small bowel strictures. Surgery was performed in 26 patients within 2 years from baseline CTE or MRE. In univariate analysis of patients with prior exams, development of stricture on the baseline exam was associated with near-term surgery (P = .006). A mathematical model using baseline features predicting surgery within 2 years included an HBI of 5 to 7 (odds ratio [OR], 1.7 × 105; P = .057), an HBI of 8 to 16 (OR, 3.1 × 105; P = .054), anastomotic stricture (OR, 0.002; P = .091), bowel wall thickness (OR, 4.7; P = .064), penetrating behavior (OR, 3.1 × 103; P = .096), and newly developed stricture (OR: 7.2 × 107; P = .062). This model demonstrated sensitivity of 67% and specificity of 73% (area under the curve, 0.62). CONCLUSIONS: CTE or MRE imaging findings in combination with HBI can potentially predict which patients will require surgery within 2 years.


Computed tomography and magnetic resonance enterography imaging measurements and observations, in combination with patient symptoms, can potentially predict which patients will require surgery within 2 years with modest degree of accuracy.


Asunto(s)
Enfermedad de Crohn , Enfermedades Intestinales , Humanos , Masculino , Enfermedad de Crohn/patología , Constricción Patológica/diagnóstico , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética
20.
N Engl J Med ; 359(12): 1207-17, 2008 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-18799557

RESUMEN

BACKGROUND: Computed tomographic (CT) colonography is a noninvasive option in screening for colorectal cancer. However, its accuracy as a screening tool in asymptomatic adults has not been well defined. METHODS: We recruited 2600 asymptomatic study participants, 50 years of age or older, at 15 study centers. CT colonographic images were acquired with the use of standard bowel preparation, stool and fluid tagging, mechanical insufflation, and multidetector-row CT scanners (with 16 or more rows). Radiologists trained in CT colonography reported all lesions measuring 5 mm or more in diameter. Optical colonoscopy and histologic review were performed according to established clinical protocols at each center and served as the reference standard. The primary end point was detection by CT colonography of histologically confirmed large adenomas and adenocarcinomas (10 mm in diameter or larger) that had been detected by colonoscopy; detection of smaller colorectal lesions (6 to 9 mm in diameter) was also evaluated. RESULTS: Complete data were available for 2531 participants (97%). For large adenomas and cancers, the mean (+/-SE) per-patient estimates of the sensitivity, specificity, positive and negative predictive values, and area under the receiver-operating-characteristic curve for CT colonography were 0.90+/-0.03, 0.86+/-0.02, 0.23+/-0.02, 0.99+/-<0.01, and 0.89+/-0.02, respectively. The sensitivity of 0.90 (i.e., 90%) indicates that CT colonography failed to detect a lesion measuring 10 mm or more in diameter in 10% of patients. The per-polyp sensitivity for large adenomas or cancers was 0.84+/-0.04. The per-patient sensitivity for detecting adenomas that were 6 mm or more in diameter was 0.78. CONCLUSIONS: In this study of asymptomatic adults, CT colonographic screening identified 90% of subjects with adenomas or cancers measuring 10 mm or more in diameter. These findings augment published data on the role of CT colonography in screening patients with an average risk of colorectal cancer. (ClinicalTrials.gov number, NCT00084929; American College of Radiology Imaging Network [ACRIN] number, 6664.)


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Adenoma/diagnóstico por imagen , Colonografía Tomográfica Computarizada , Neoplasias Colorrectales/diagnóstico por imagen , Adenocarcinoma/diagnóstico , Adenocarcinoma/patología , Adenoma/diagnóstico , Adenoma/patología , Anciano , Colon/diagnóstico por imagen , Pólipos del Colon/diagnóstico , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/patología , Colonoscopía , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA