Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 169
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Anal Bioanal Chem ; 412(19): 4647-4658, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32488383

RESUMEN

For the quality control of biopharmaceutical products, which contain proteins as the most important active ingredients, shelf life may be limited due to inappropriate storage conditions or mechanical stress. For insulins as representatives of life-saving pharmaceuticals, analytical methods are needed, which are providing additional information than obtained by assays for total protein quantification. Despite sophisticated formulations, the chemical stability may be challenged by temperatures deviating from recommended conditions or shear rate exposure under storage, leading to misfolding, nucleation, and subsequent fibril formation, accompanied by a decrease in bioactivity. A reliable method for insulin quantification and determination of secondary structure changes has been developed by attenuated total reflection (ATR) Fourier-transform infrared spectroscopy of insulin formulations by a silver halide fiber-coupled diamond probe with subsequent dry-film preparation. A special emphasis has been placed on the protein amide I band evaluation, for which spectral band analysis provides unique information on secondary structure fractions for intact and misfolded insulins. Quantitative measurements are possible down to concentrations of less than 0.5 mg/ml, whereas the dry-film preparation delivers high signal-to-noise ratios due to the prior water evaporation, thus allowing a reliable determination of secondary structure information. Graphical abstract.


Asunto(s)
Hipoglucemiantes/química , Insulina/química , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Animales , Productos Biológicos/química , Humanos , Estructura Secundaria de Proteína , Proteínas/química
2.
Anal Bioanal Chem ; 411(1): 63-77, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30283998

RESUMEN

Diabetes mellitus is a widespread disease with greatly rising patient numbers expected in the future, not only for industrialized countries but also for regions in the developing world. There is a need for efficient therapy, which can be via self-monitoring of blood glucose levels to provide tight glycemic control for reducing the risks of severe health complications. Advancements in diabetes technology can nowadays offer different sensor approaches, even for continuous blood glucose monitoring. Non-invasive blood glucose assays have been promised for many years and various vibrational spectroscopy-based methods of the skin are candidates for achieving this goal. Due to the small spectral signatures of the glucose hidden among a largely variable background, the largest signal-to-noise ratios and multivariate calibration are essential to provide the method applicability for self-monitoring of blood glucose. Besides multiparameter approaches, recently presented devices based on photoplethysmography with wavelengths in the visible and near-infrared range are evaluated for their potential of providing reliable blood glucose concentration predictions. Graphical abstract ᅟ.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/análisis , Piel , Análisis Espectral/métodos , Calibración , Diabetes Mellitus/sangre , Humanos , Fotopletismografía/métodos , Sensibilidad y Especificidad
3.
Analyst ; 138(14): 4092-102, 2013 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-23712384

RESUMEN

The extraction of disease specific information from Fourier transform infrared (FTIR) spectra of human body fluids demands the highest standards of accuracy and reproducibility of measurements because the expected spectral differences between healthy and diseased subjects are very small in relation to a large background absorbance of the whole sample. Here, we demonstrate that with the increased sensitivity of modern FTIR spectrometers, automatisation of sample preparation and modern bioinformatics, it is possible to identify and validate spectral biomarker candidates for distinguishing between urinary bladder cancer (UBC) and inflammation in suspected bladder cancer patients. The current dataset contains spectra of blood serum and plasma samples of 135 patients. All patients underwent cytology and pathological biopsy characterization to distinguish between patients without UBC (46) and confirmed UBC cases (89). A minimally invasive blood test could spare control patients a repeated cystoscopy including a transurethral biopsy, and three-day stationary hospitalisation. Blood serum, EDTA and citrate plasma were collected from each patient and processed following predefined strict standard operating procedures. Highly reproducible dry films were obtained by spotting sub-nanoliter biofluid droplets in defined patterns, which were compared and optimized. Particular attention was paid to the automatisation of sample preparation and spectral preprocessing to exclude errors by manual handling. Spectral biomarker candidates were identified from absorbance spectra and their 1(st) and 2(nd) derivative spectra using an advanced Random Forest (RF) approach. It turned out that the 2(nd) derivative spectra were most useful for classification. Repeat validation on 21% of the dataset not included in predictor training with Linear Discriminant Analysis (LDA) classifiers and Random Forests (RFs) yielded a sensitivity of 93 ± 10% and a specificity of 46 ± 18% for bladder cancer. The low specificity can be most likely attributed to the unbalanced and small number of control samples. Using this approach, spectral biomarker candidates in blood-derived biofluids were identified, which allow us to distinguish between cancer and inflammation, but the observed differences were tiny. Obviously, a much larger sample number has to be investigated to reliably validate such candidates.


Asunto(s)
Biomarcadores de Tumor/sangre , Carcinoma Papilar/diagnóstico , Recurrencia Local de Neoplasia/diagnóstico , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Neoplasias de la Vejiga Urinaria/diagnóstico , Anciano , Carcinoma Papilar/sangre , Estudios de Casos y Controles , Análisis Discriminante , Femenino , Humanos , Masculino , Microscopía de Fuerza Atómica , Persona de Mediana Edad , Clasificación del Tumor , Recurrencia Local de Neoplasia/sangre , Estadificación de Neoplasias , Vejiga Urinaria/patología , Neoplasias de la Vejiga Urinaria/sangre
5.
J Diabetes Sci Technol ; 15(4): 865-873, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-32281880

RESUMEN

BACKGROUND: For insulins in commercial formulations, degradation can be observed within the certified shelf life when not stored at recommended conditions. Elevated temperatures and exposure to shear forces can cause changes in the secondary structure of the hormone, leading to a decrease in pharmaceutical potency. International pharmacopoeia recommendations for insulin quality monitoring assays mainly rely on liquid chromatography methods. These methods are unable to distinguish between active and inactive forms, both of which may exist in pharmaceutical insulins exposed to stress conditions. METHOD: Infrared attenuated total reflection spectroscopy has been used for the analysis of insulin dry film preparations using affordable instrumentation. This method can be applied to either formulated insulin specimens or pure insulins obtained by ultrafiltration. Such samples have been stored under different temperatures (0°C, 20°C, and 37°C), and degradation processes have been monitored up to a period of a few months. RESULTS: By analyzing specific shifts of absorption bands in the infrared spectra, which are sensitive to the protein secondary structure, even small structural changes in the hormone become evident. Another option is amide I band deconvolution into individual bands, which can be attributed to secondary structure subunits that are part of the insulin tertiary structure. CONCLUSION: A novel and innovative method based on infrared attenuated total reflection spectroscopy of insulin dry films is a promising analytical tool for quantifying the degree of insulin degradation, as it provides information on indicating a decrease in biological potency. The established methods for insulin potency assays require animal testing or clamp experiments on people with diabetes.


Asunto(s)
Insulina , Animales , Humanos , Estructura Secundaria de Proteína , Espectrofotometría Infrarroja , Espectroscopía Infrarroja por Transformada de Fourier
6.
J Biomed Opt ; 26(4)2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33686847

RESUMEN

SIGNIFICANCE: Bioactive proteins represent the most important component class in biopharmaceutical products for therapeutic applications. Their production is most often biotechnologically realized by genetically engineered microorganisms. For the quality assurance of insulins as representatives of life-saving pharmaceuticals, analytical methods are required that allow more than total protein quantification in vials or batches. Chemical and physical factors such as unstable temperatures or shear rate exposure under storage can lead to misfolding, nucleation, and subsequent fibril forming of the insulins. The assumption is valid that these processes go parallel with a decrease in bioactivity. AIM: Infrared (IR) spectroscopy has been successfully utilized for secondary structure analysis in cases of protein misfolding and fibril formation. APPROACH: A reliable method for the quantification of the secondary structure changes has been developed using insulin dry-film Fourier-transform IR spectroscopy in combination with the attenuated total reflection (ATR) technique and subsequent data analyses such as band-shift determination, spectral band deconvolution, and principal component analysis. RESULTS: A systematic study of insulin spectra was carried out on model insulin specimens, available either as original formulations or as hormones purified by ultrafiltration. Insulin specimens were stored at different temperatures, i.e., 0°C, 20°C, and 37°C, respectively, for up to three months. Weekly ATR-measurements allowed the monitoring of hormone secondary structure changes, which are supposed to be negatively correlated with insulin bioactivity. CONCLUSIONS: It could be shown that IR-ATR spectroscopy offers a fast and reliable analytical method for the determination of secondary structural changes within insulin molecules, as available in pharmaceutical insulin formulations and therefore challenges internationally established measurement techniques for quality control regarding time, costs, and effort of analysis.


Asunto(s)
Productos Biológicos , Insulina , Estructura Secundaria de Proteína , Proteínas , Espectroscopía Infrarroja por Transformada de Fourier
7.
J Diabetes Sci Technol ; 15(1): 19-27, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32590911

RESUMEN

BACKGROUND: A wide range of optical techniques has recently been presented for the development of noninvasive methods for blood glucose sensing based on multivariate skin spectrum analysis, and most recent studies are reviewed in short by us. The vibrational spectral fingerprints of glucose, as especially found in the mid-infrared or Raman spectrum, have been suggested for achieving largest selectivity for the development of noninvasive blood glucose methods. METHODS: Here, the different aspects on integral skin measurements are presented, which are much dependent on the absorption characteristics of water as the main skin constituent. In particular, different mid-infrared measurement techniques as realized recently are discussed. The limitations of the use of the attenuated total reflection technique in particular are elaborated, and confounding skin or saliva spectral features are illustrated and discussed in the light of recently published works, claiming that the attenuated total reflection technique can be utilized for noninvasive measurements. RESULTS: It will be shown that the penetration depth of the infrared radiation with wavelengths around 10 µm is the essential parameter, which can be modulated by different measurement techniques as with photothermal or diffuse reflection. However, the law of physics is limiting the option of using the attenuated total reflection technique with waveguides from diamond or similar optical materials. CONCLUSIONS: There are confounding features from mucosa, stratum corneum, or saliva, which have been misinterpreted for glucose measurements. Results of an earlier study with multivariate evaluation based on glucose fingerprint features are again referred to as a negative experimental proof.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Glucosa , Humanos , Piel , Espectrofotometría Infrarroja
8.
Biosensors (Basel) ; 11(3)2021 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-33673679

RESUMEN

For many years, successful noninvasive blood glucose monitoring assays have been announced, among which near-infrared (NIR) spectroscopy of skin is a promising analytical method. Owing to the tiny absorption bands of the glucose buried among a dominating variable spectral background, multivariate calibration is required to achieve applicability for blood glucose self-monitoring. The most useful spectral range with important analyte fingerprint signatures is the NIR spectral interval containing combination and overtone vibration band regions. A strategy called science-based calibration (SBC) has been developed that relies on a priori information of the glucose signal ("response spectrum") and the spectral noise, i.e., estimates of the variance of a sample population with negligible glucose dynamics. For the SBC method using transcutaneous reflection skin spectra, the response spectrum requires scaling due to the wavelength-dependent photon penetration depth, as obtained by Monte Carlo simulations of photon migration based on estimates of optical tissue constants. Results for tissue glucose concentrations are presented using lip NIR-spectra of a type-1 diabetic subject recorded under modified oral glucose tolerance test (OGTT) conditions. The results from the SBC method are extremely promising, as statistical calibrations show limitations under the conditions of ill-posed equation systems as experienced for tissue measurements. The temporal profile differences between the glucose concentration in blood and skin tissue were discussed in detail but needed to be further evaluated.


Asunto(s)
Glucosa/análisis , Monitoreo Fisiológico , Espectroscopía Infrarroja Corta , Glucemia , Automonitorización de la Glucosa Sanguínea , Calibración , Diabetes Mellitus , Piel
9.
Science ; 293(5527): 82-5, 2001 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-11441177

RESUMEN

Nuclear magnetic resonance (NMR) experiments are typically performed with samples immersed in a magnet shimmed to high homogeneity. However, there are many circumstances in which it is impractical or undesirable to insert objects or subjects into the bore of a high-field magnet. Here we present a methodology based on an adaptation of nutation echoes that provides resolved spectra in the presence of matched inhomogeneous static and radiofrequency fields, thereby opening the way to high-resolution ex situ NMR. The observation of chemical shifts is regained through the use of multiple-pulse sequences of correlated, composite z-rotation pulses, producing resolved NMR spectra of liquid samples.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Magnetismo , Protones , Rotación , Soluciones
10.
Anal Bioanal Chem ; 390(1): 125-39, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17955220

RESUMEN

In recent years, near-infrared spectroscopy (NIRS) has gained importance for non-invasive or minimally invasive diagnostic applications in cancer. This technology is based on differences of endogenous chromophores between cancer and normal tissues using either oxy-haemoglobin or deoxy-haemoglobin, lipid or water bands, or a combination of two or more of these as diagnostic markers. These marker bands provide a basis for the diagnosis and therapy monitoring of several cancers. Various applications also use advances in NIR fluorescence spectroscopy which is based on exogenous contrast-enhancing agents. In this review the literature published during the last seven years has been assessed. It will provide an overview on the importance of the NIRS tools in cancer pathology, and in the near future it is envisaged to play a crucial role in cancer diagnosis, treatment decisions, and defining therapeutic drug levels.


Asunto(s)
Neoplasias/diagnóstico , Neoplasias/terapia , Espectroscopía Infrarroja Corta/instrumentación , Espectroscopía Infrarroja Corta/métodos , Animales , Biomarcadores de Tumor , Humanos , Neoplasias/irrigación sanguínea , Neoplasias/metabolismo , Neoplasias/cirugía
11.
J Diabetes Sci Technol ; 12(6): 1169-1177, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30222001

RESUMEN

Noninvasive blood glucose assays have been promised for many years and various molecular spectroscopy-based methods of skin are candidates for achieving this goal. Due to the small spectral signatures of the glucose used for direct physical detection, moreover hidden among a largely variable background, broad spectral intervals are usually required to provide the mandatory analytical selectivity, but no such device has so far reached the accuracy that is required for self-monitoring of blood glucose (SMBG). A recently presented device as described in this journal, based on photoplethysmographic fingertip images for measuring glucose in a nonspecific indirect manner, is especially evaluated for providing reliable blood glucose concentration predictions.


Asunto(s)
Glucemia/análisis , Equipos y Suministros , Dedos/diagnóstico por imagen , Fotopletismografía , Piel/diagnóstico por imagen , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Calibración , Color , Diseño de Equipo , Dedos/irrigación sanguínea , Humanos , Rayos Infrarrojos , Luz , Iluminación/instrumentación , Iluminación/métodos , Fotopletismografía/instrumentación , Fotopletismografía/métodos , Reproducibilidad de los Resultados , Piel/irrigación sanguínea , Espectroscopía Infrarroja Corta
12.
J Biomed Opt ; 12(2): 024004, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17477719

RESUMEN

An IR-spectroscopy-based bedside device, coupled to a subcutaneously implanted microdialysis probe, is developed for quasicontinuous glucose monitoring with intermittent readouts at 10-min intervals, avoiding any sensor recalibration under long-term operation. The simultaneous estimation of the microdialysis recovery rate is possible using an acetate containing perfusate and determining its losses across the dialysis membrane. Measurements are carried out on four subjects, with experiments lasting either 8 or 28 h, respectively. Using the spectral interval data either from 1180 to 950 or 1560 to 1000 cm(-1), standard errors of prediction (SEPs) between 0.13 and 0.28 mM are achieved using multivariate calibration with partial least-squares (PLS) or classical least-squares (CLS) calibration models, respectively. The transfer of a PLS calibration model using the spectral and reference concentration data of the dialysates from the three 8-h-long experiments to a 28-h monitoring episode with another healthy subject is tested. Including microdialysis recovery for the determination of the interstitial glucose concentrations, an SEP of 0.24 mM is obtained versus whole blood glucose values. The option to determine other metabolites such as urea or lactate offers the possibility to develop a calibration- and reagent-free point-of-care analyzer.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/análisis , Microdiálisis/métodos , Monitoreo Ambulatorio/métodos , Sistemas de Atención de Punto , Espectrofotometría Infrarroja/métodos , Humanos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Anal Bioanal Chem ; 388(3): 545-63, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17431594

RESUMEN

Implementing strict glycemic control can reduce the risk of serious complications in both diabetic and critically ill patients. For this reason, many different analytical, mainly electrochemical and optical sensor approaches for glucose measurements have been developed. Self-monitoring of blood glucose (SMBG) has been recognised as being an indispensable tool for intensive diabetes therapy. Recent progress in analytical instrumentation, allowing submicroliter samples of blood, alternative site testing, reduced test time, autocalibration, and improved precision, is comprehensively described in this review. Continuous blood glucose monitoring techniques and insulin infusion strategies, developmental steps towards the realization of the dream of an artificial pancreas under closed loop control, are presented. Progress in glucose sensing and glycemic control for both patient groups is discussed by assessing recent published literature (up to 2006). The state-of-the-art and trends in analytical techniques (either episodic, intermittent or continuous, minimal-invasive, or noninvasive) detailed in this review will provide researchers, health professionals and the diabetic community with a comprehensive overview of the potential of next-generation instrumentation suited to either short- and long-term implantation or ex vivo measurement in combination with appropriate body interfaces such as microdialysis catheters.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Cuidados Críticos/métodos , Diabetes Mellitus/sangre , Hiperglucemia/sangre , Automonitorización de la Glucosa Sanguínea/métodos , Enfermedad Crítica , Diabetes Mellitus/tratamiento farmacológico , Humanos , Hiperglucemia/tratamiento farmacológico , Sensibilidad y Especificidad
14.
Appl Spectrosc ; 60(8): 920-5, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16925929

RESUMEN

Application of mid-infrared spectroscopy for the determination of urea in blood plasma dialysates of microliter sample volumes using a transmission microcell was investigated. Infrared spectra of the dialysates of plasma samples collected from 75 different patients using CMA 60 microdialysis catheters were evaluated with multivariate partial least squares regression. Using the absorbance spectral data from 1520-1420 cm(-1) and 1220-1120 cm(-1), a minimum standard error of prediction (SEP) of 0.88 mg/dL (0.14 mM) was achieved with spectral variable selection. Our findings suggest the feasibility of developing a mid-infrared sensor in combination with micro-fluidics for on-line monitoring of urea in patients undergoing dialysis treatment.


Asunto(s)
Fallo Renal Crónico/sangre , Diálisis Renal , Espectrofotometría Infrarroja/instrumentación , Espectrofotometría Infrarroja/métodos , Urea/sangre , Biomarcadores , Humanos , Fallo Renal Crónico/terapia , Análisis de los Mínimos Cuadrados , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos
15.
Biochim Biophys Acta ; 1061(2): 121-31, 1991 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-1900196

RESUMEN

The interaction of platelet talin (P-235) with mixtures of dimyristoylphosphatidylcholine (DMPC), dimyristoylphosphatidylglycerol (DMPG) and dimyristoylphosphatidylserine (DMPS) as well as with pure lipids was studied in reconstituted lipid bilayers. Incorporation of platelet talin into vesicles was achieved by self-assembly during cycles of freeze-thawing of co-dispersions containing vesicles and the purified protein. The yield of protein incorporation as a function of lipid composition was determined by measuring the protein/lipid ratio using protein assay, phosphate determination and gel electrophoresis in parallel. Protein-lipid interactions are monitored by high sensitive differential scanning calorimetry (DSC) measuring (i) the shifts of transition states delta Ts* and delta Tl*, where Ts represents the solidus line, the onset of lipid chain melting, and Tl the liquidus line, the endpoint of chain melting, and (ii) the heats of transition. Cytoplasmic talin differs from a membrane bound form by its ability and mode of lipid interaction. The latter partially penetrates into the hydrophobic region of the bilayer, which renders a low incorporation rate even into neutral lipids. This interaction is greatly enhanced in the presence of charged lipids: a marked shift of Tl occurs due to a selective electrostatic interaction of the protein with the membrane surface. Evidence for a selective binding is also provided by Fourier transform infrared spectroscopy (FTIR). Right-side-out oriented platelet talin can be cleaved by proteinases, which truncate the extrinsic electrostatic binding domain but not the hydrophobic. In addition, reconstituted platelet talin, like in vivo, can be cleaved by thrombin. The interaction of cytoplasmic platelet talin with lipid bilayers is purely electrostatic. Our data suggest that protein reconstitution by freeze-thawing is an equilibrium process and that the protein distribution between the membrane and water is determined by the Nernst distribution law. Consequently, the work of protein transfer from water into the bilayer can be measured as a function of charged lipids.


Asunto(s)
Proteínas Sanguíneas/metabolismo , Proteínas del Citoesqueleto/metabolismo , Membrana Dobles de Lípidos/metabolismo , Proteínas de la Membrana/metabolismo , Membrana Celular/efectos de los fármacos , Membrana Celular/ultraestructura , Centrifugación por Gradiente de Densidad , Citoplasma/efectos de los fármacos , Citoplasma/ultraestructura , Endopeptidasas/farmacología , Técnica de Fractura por Congelación , Calor , Humanos , Fosfatos/química , Fosfolípidos/metabolismo , Cloruro de Sodio/farmacología , Espectrofotometría Infrarroja , Talina , Trombina/farmacología
16.
Appl Spectrosc ; 59(4): 442-51, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15901329

RESUMEN

The aim of this study was to demonstrate that mid-infrared spectroscopy is able to quantify glucose in a serum matrix with sample volumes well below 1 muL. For this, we applied mid-infrared attenuated total reflectance (ATR) or transmission-based spectroscopic methods to glucose quantification in microsamples of dry-film sera, either undiluted or diluted 10 times in distilled water. The sample series spanned physiological glucose concentrations between 50 and 600 mg/dL and volumes of 80, 8, and 1 nL. Calibration was carried out using multivariate partial least-squares (PLS) modeling with spectral data between 1180 and 940 cm(-1). Best performance was achieved in the ATR experiments. For raw ATR spectra, the optimum standard error of prediction (SEP) of 13.3 mg/dL was obtained for the 8 nL sample series with subsequent 10-fold dilution. With respect to the coefficient of variation of the glucose assay, CV(pred), we obtained a value of 3% for the 80 nL volume samples with spectral preprocessing using matrix protein absorption bands as an internal standard, 4% for the 8 nL samples, and 6% for the 1 nL samples with raw data. Spectral standardization resulted in significant improvement, especially for the 80 nL volume sample series. By contrast, the accuracy of the glucose assay for the 1 nL sample volume series could not be improved either by internal standardization or by considering the dry film areas for normalization, which we attribute to varying topographies of the dry films.


Asunto(s)
Análisis Químico de la Sangre/métodos , Glucemia/análisis , Microquímica/métodos , Nanotecnología/métodos , Refractometría/métodos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Appl Spectrosc ; 59(10): 1286-94, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16274542

RESUMEN

The limits of quantitative multivariate assays for the analysis of extra virgin olive oil samples from various Greek sites adulterated by sunflower oil have been evaluated based on their Fourier transform (FT) Raman spectra. Different strategies for wavelength selection were tested for calculating optimal partial least squares (PLS) models. Compared to the full spectrum methods previously applied, the optimum standard error of prediction (SEP) for the sunflower oil concentrations in spiked olive oil samples could be significantly reduced. One efficient approach (PMMS, pair-wise minima and maxima selection) used a special variable selection strategy based on a pair-wise consideration of significant respective minima and maxima of PLS regression vectors, calculated for broad spectral intervals and a low number of PLS factors. PMMS provided robust calibration models with a small number of variables. On the other hand, the Tabu search strategy recently published (search process guided by restrictions leading to Tabu list) achieved lower SEP values but at the cost of extensive computing time when searching for a global minimum and less robust calibration models. Robustness was tested by using packages of ten and twenty randomly selected samples within cross-validation for calculating independent prediction values. The best SEP values for a one year's harvest with a total number of 66 Cretian samples were obtained by such spectral variable optimized PLS calibration models using leave-20-out cross-validation (values between 0.5 and 0.7% by weight). For the more complex population of olive oil samples from all over Greece (total number of 92 samples), results were between 0.7 and 0.9% by weight with a cross-validation sample package size of 20. Notably, the calibration method with Tabu variable selection has been shown to be a valid chemometric approach by which a single model can be applied with a low SEP of 1.4% for olive oil samples across three different harvest years.


Asunto(s)
Análisis de los Alimentos/métodos , Contaminación de Alimentos , Aceites de Plantas/química , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Calibración , Unión Europea , Grecia , Análisis de los Mínimos Cuadrados , Análisis Multivariante , Aceite de Oliva , Aceite de Girasol
18.
Neurology ; 36(5): 597-601, 1986 May.
Artículo en Inglés | MEDLINE | ID: mdl-3703257

RESUMEN

Eight hundred eighty-seven children with brain tumors were identified by the SEER registries (1973-1980). Twenty-five percent were low-grade supratentorial astrocytomas, medulloblastomas were 23%, cerebellar astrocytomas 12%, high-grade supratentorial astrocytomas 11%, brainstem gliomas 9%, and ependymomas 8%. The worst survivals were in children less than 2 years of age, and the best were in those aged 10 to 14 years. Five-year survivals of children with cerebellar astrocytomas were 91%, low-grade supratentorial astrocytomas 71%, high-grade supratentorial astrocytomas 35%, medulloblastomas 39%, ependymomas 28%, and brainstem gliomas 18%.


Asunto(s)
Neoplasias Encefálicas/mortalidad , Glioma/mortalidad , Adolescente , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/terapia , Neoplasias Cerebelosas/mortalidad , Neoplasias Cerebelosas/patología , Neoplasias Cerebelosas/terapia , Niño , Preescolar , Ependimoma/mortalidad , Ependimoma/patología , Ependimoma/terapia , Femenino , Glioma/patología , Glioma/terapia , Humanos , Lactante , Recién Nacido , Masculino , Meduloblastoma/mortalidad , Meduloblastoma/patología , Meduloblastoma/terapia , Sistema de Registros
19.
APMIS ; 96(8): 735-40, 1988 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-2458121

RESUMEN

The presence or absence of a polysaccharide capsule on the human pathogen Neisseria (N.) gonorrhoeae is still a topic of controversy. For this reason we compared the results obtained by light microscopy (dry India ink-Fuchsin stain) and electron microscopy (Alcian blue-lanthanum nitrate stain) of encapsulated strains of N. meningitidis and Streptococcus (S.) pneumoniae and of non-encapsulated strains of S. pneumoniae and Escherichia (E.) coli with those obtained using the same methods on strains of pilliated and non-pilliated N. gonorrhoeae. After staining with India ink-Fuchsin no capsules could be demonstrated on any of the N. gonorrhoeae strains studied. If present the capsules on these cells are too delicate to be identified by light microscopy. After treatment with Alcian blue-lanthanum nitrate sections of cells of N. meningitidis and S. pneumoniae generally showed the presence of a capsular layer. Sections of cells of the non-encapsulated strain of S. pneumoniae which possess C (common)-polysaccharide also showed surface associated capsule-like material. Similarly the surface of the cells of the E. coli strain showed material which appeared to be tufts of pili and/or M (mucoid)-antigen. In experiments where the N. gonorrhoeae cells were harvested as early as after six hours of growth a capsule-like material was demonstrated on cells of all strains studied.


Asunto(s)
Neisseria gonorrhoeae/ultraestructura , Polisacáridos Bacterianos/análisis , Medios de Cultivo , Fimbrias Bacterianas/ultraestructura , Humanos , Microscopía Electrónica , Neisseria gonorrhoeae/análisis , Neisseria gonorrhoeae/crecimiento & desarrollo , Coloración y Etiquetado
20.
J Magn Reson ; 150(2): 198-206, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11384181

RESUMEN

The paramagnetic metallocenes and decamethylmetallocenes (C(5)H(5))(2)M and (C(5)Me(5))(2)M with M=V (S=3/2), Mn (S=5/2 or 1/2), Co (S=1/2), and Ni (S=1) were studied by (1)H and (13)C solid-state MAS NMR spectroscopy. Near room temperature spinning sideband manifolds cover ranges of up to 1100 and 3500 ppm, and isotropic signal shifts appear between -260 and 300 ppm and between -600 and 1640 ppm for (1)H and (13)C NMR spectra, respectively. The isotropic paramagnetic signal shifts, which are related to the spin densities in the s orbital of ligand atoms, were discussed. A Herzfeld--Berger spinning sideband analysis of the ring carbon signals yielded the principal values of the paramagnetic shift tensors, and for metallocenes with a small g-factor anisotropy the electron spin density in the ligand pi system was determined from the chemical shift anisotropy. The unusual features of the (1)H and (13)C solid-state NMR spectra of manganocene were related to its chain structure while temperature-dependent (1)H MAS NMR studies reflected antiferromagnetic interaction between the spin centers.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA