Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Colon Rectal Surg ; 37(4): 207-215, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38882937

RESUMEN

Though resection has been the mainstay of treatment for nonmetastatic rectal cancer over the past century, radiation has become an increasingly integral component of care for locally advanced disease. Today, two predominant radiotherapy approaches-hyperfractionated chemoradiotherapy and "short-course" radiation-are widely utilized to reduce local recurrence and, in some cases, cure disease. Both have been incorporated into total neoadjuvant therapy (TNT) regimens and achieved excellent local control and superior complete response rates compared to chemoradiation alone. Additionally, initial results of "watch and wait" protocols utilizing either radiation modality have been promising. Yet, differences do exist; though short course is cheaper and more convenient for patients, recently published data may show superior complete response and local recurrence rates with chemoradiation. Ultimately, direct comparisons of short-course radiotherapy against chemoradiation within the TNT framework are needed to identify optimal radiation regimens in the treatment of locally advanced rectal cancer.

2.
Dis Colon Rectum ; 66(7): 973-982, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-36876988

RESUMEN

BACKGROUND: Short-course radiation therapy and consolidation chemotherapy with nonoperative intent has emerged as a novel treatment paradigm for patients with rectal cancer, but there are no data on the predictors of clinical complete response. OBJECTIVE: Evaluate the predictors of clinical complete response and survival. DESIGN: Retrospective cohort. SETTINGS: National Cancer Institute-designated cancer center. PATIENTS: Patients with stage I to III rectal adenocarcinoma treated between January 2018 and May 2019 (n = 86). INTERVENTIONS: Short-course radiation therapy followed by consolidation chemotherapy. MAIN OUTCOME MEASURES: Logistic regression was performed to assess for predictors of clinical complete response. The end points included local regrowth-free survival, regional control, distant metastasis-free survival, and overall survival. RESULTS: A positive (+) circumferential resection margin by MRI at diagnosis was a significant predictor of nonclinical complete response (OR: 4.1, p = 0.009) when adjusting for CEA level and primary tumor size. Compared to patients with a negative (-) pathologic circumferential resection margin, patients with a positive (+) pathologic circumferential resection margin had inferior local regrowth-free survival (29% vs 87%, p < 0.001), regional control (57% vs 94%, p < 0.001), distant metastasis-free survival (43% vs 95%, p < 0.001), and overall survival (86% vs 95%, p < 0.001) at 2 years. However, the (+) and (-) circumferential resection margin by MRI subgroups in patients who had a clinical complete response both had similar regional control, distant metastasis-free survival, and overall survival of more than 90% at 2 years. LIMITATIONS: Retrospective design, modest sample size, short follow-up, and the heterogeneity of treatments. CONCLUSIONS: Circumferential resection margin involvement by MRI at diagnosis is a strong predictor of nonclinical complete response. However, patients who achieve a clinical complete response after short-course radiation therapy and consolidation chemotherapy with nonoperative intent have excellent clinical outcomes regardless of the initial circumferential resection margin status. See Video Abstract at http://links.lww.com/DCR/C190 . EL MARGEN DE RESECCIN CIRCUNFERENCIAL COMO PREDICTOR NO CLNICO DE RESPUESTA COMPLETA EN EL MANEJO CONSERVADOR DEL CNCER DE RECTO: ANTECEDENTES:La radioterapia de corta duración y la quimioterapia de consolidación en el manejo conservador, han surgido como un nuevo paradigma de tratamiento, para los pacientes con cáncer de recto, lastimosamente no hay datos definitivos sobre los predictores de una respuesta clínica completa.OBJETIVO:Evaluar los predictores de respuesta clínica completa y de la sobrevida.DISEÑO:Estudio retrospectivo de cohortes.AJUSTES:Centro oncológico designado por el NCI.PACIENTES:Adenocarcinomas de recto estadio I-III tratados entre 01/2018 y 05/2019 (n = 86).INTERVENCIONES:Radioterapia de corta duración seguida de quimioterapia de consolidación.PRINCIPALES MEDIDAS DE RESULTADO:Se realizó una regresión logística para evaluar los predictores de respuesta clínica completa. Los criterios de valoración incluyeron la sobrevida libre de recidiva local, el control regional, la sobrevida libre de metástasis a distancia y la sobrevida general.RESULTADOS:Un margen de resección circunferencial positivo (+) evaluado por imagenes de resonancia magnética nuclear en el momento del diagnóstico fue un predictor no clínico muy significativo de respuesta completa (razón de probabilidades/ OR: 4,1, p = 0,009) al ajustar el nivel de antígeno carcinoembrionario y el tamaño del tumor primario. Comparando con los pacientes que presetaban un margen de resección circunferencial patológico negativo (-), los pacientes con un margen de resección circunferencial patológico positivo (+) tuvieron una sobrevida libre de recidiva local (29% frente a 87%, p < 0,001), un control regional (57% frente a 94%, p < 0,001), una sobrevida libre de metástasis a distancia (43% frente a 95%, p < 0,001) y una sobrevida global (86% frente a 95%, p < 0,001) inferior en 2 años de seguimiento. Sin embargo, los subgrupos de margen de resección circunferencial (+) y (-) evaluados por imágenes de resonancia magnética nuclear en pacientes que tuvieron una respuesta clínica completa tuvieron un control regional similar, una sobrevida libre de metástasis a distancia y una sobrevida general >90% en 2 años de seguimiento.LIMITACIONES:Diseño retrospectivo, tamaño modesto de la muestra, seguimiento corto y heterogeneidad de tratamientos.CONCLUSIONES:La afectación del margen de resección circunferencial evaluado por resonancia magnética nuclear al momento del diagnóstico es un fuerte factor predictivo no clínico de respuesta completa. Sin embargo, los pacientes que logran una respuesta clínica completa después de un curso corto de radioterapia y quimioterapia de consolidación como manejo conservador tienen excelentes resultados clínicos independientemente del estado del margen de resección circunferencial inicial. Consulte Video Resumen en http://links.lww.com/DCR/C190 . (Traducción-Dr. Xavier Delgadillo ).


Asunto(s)
Márgenes de Escisión , Neoplasias del Recto , Humanos , Estudios Retrospectivos , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/cirugía , Recto/patología , Recurrencia Local de Neoplasia/patología , Estadificación de Neoplasias , Resultado del Tratamiento
3.
Int J Hyperthermia ; 36(1): 1147-1159, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31752562

RESUMEN

Purpose: To evaluate the feasibility and assess safety parameters of magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU)-mediated hyperthermia (HT; heating to 40-45 °C) in various pelvic targets in a porcine model in vivo.Methods: Thirteen HT treatments were performed in six pigs with a commercial MRgHIFU system (Sonalleve V2, Profound Medical Inc., Mississauga, Canada) to muscle adjacent to the ventral/dorsal bladder wall and uterus to administer 42 °C (±1°) for 30 min (±5%) using an 18-mm target diameter and 100 W power. Feasibility was assessed using accuracy, uniformity, and MR-thermometry performance-based metrics. Safety parameters were assessed for tissues in the targets and beam-path by contrast-enhanced MRI, gross-pathology and histopathology.Results: Across all HT sessions, the mean difference between average temperature (Tavg) and the target temperature within the target region-of-interest (tROI, the cross-section of the heated volume at focal depth) was 0.51 ± 0.33 °C. Within the tROI, the temperature standard deviation averaged 1.55 ± 0.31 °C, the average 30-min Tavg variation was 0.80 ± 0.17 °C, and the maximum difference between Tavg and the 10th- or 90th-percentile temperature averaged 2.01 ± 0.44 °C. The average time to reach ≥41 °C and cool to ≤40 °C within the tROI at the beginning and end of treatment was 47.25 ± 27.47 s and 66.37 ± 62.68 s, respectively. Compared to unheated controls, no abnormally-perfused tissue or permanent damage was evident in the MR images, gross pathology or histological analysis.Conclusions: MRgHIFU-mediated HT is feasible and safety assessment is satisfactory for treating an array of clinically-mimicking pelvic geometries in a porcine model in vivo, implying the technique may have utility in treating pelvic targets in human patients.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Imagen por Resonancia Magnética/métodos , Pelvis/patología , Animales , Estudios de Factibilidad , Fiebre , Humanos , Porcinos
4.
Br J Cancer ; 118(1): 72-78, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29112685

RESUMEN

BACKGROUND: Pretreatment serum squamous cell carcinoma antigen (SCCA) is a prognostic biomarker in women with cervical cancer. SCCA has not been evaluated as an early indicator of response to chemoradiation therapy (CRT). The molecular role of the two SCCA isoforms, SCCA1 (SERPINB3) and SCCA2 (SERPINB4), in cervical cancer is unknown. We hypothesised that changes in serum SCCA during definitive CRT predicts treatment response, and that SCCA1 mediates radiation resistance. METHODS: Patients treated with definitive CRT for cervical squamous carcinoma with serum SCCA measured were included. SCCA immunohistochemistry was performed on tumour biopsies. Post-treatment FDG-PET/CT, recurrence, and overall survival were recorded. Radiation response of cervical tumour cell lines after SCCA1 expression or CRISPR/Cas9 knockout was evaluated by clonogenic survival assay. RESULTS: Persistently elevated serum SCCA during definitive CRT was an independent predictor of positive post-therapy FDG-PET/CT (P=0.043), recurrence (P=0.0046) and death (P=0.015). An SCCA1-expressing vector increased radioresistance, while SCCA knock out increased radiosensitivity of cervical tumour cell lines in vitro. CONCLUSIONS: Early response assessment with serum SCCA is a powerful prognostic tool. These findings suggest that escalation of therapy in patients with elevated or sustained serum SCCA and molecular targeting of SCCA1 should be considered.


Asunto(s)
Antígenos de Neoplasias/sangre , Antígenos de Neoplasias/metabolismo , Biomarcadores de Tumor/sangre , Carcinoma de Células Escamosas/terapia , Quimioradioterapia/métodos , Serpinas/sangre , Serpinas/metabolismo , Neoplasias del Cuello Uterino/terapia , Adulto , Anciano , Anciano de 80 o más Años , Antígenos de Neoplasias/genética , Biomarcadores de Tumor/genética , Biomarcadores de Tumor/metabolismo , Carcinoma de Células Escamosas/sangre , Carcinoma de Células Escamosas/metabolismo , Línea Celular Tumoral , Cisplatino/administración & dosificación , Cisplatino/uso terapéutico , Fraccionamiento de la Dosis de Radiación , Femenino , Técnicas de Silenciamiento del Gen , Humanos , Persona de Mediana Edad , Serpinas/genética , Análisis de Supervivencia , Resultado del Tratamiento , Regulación hacia Arriba , Neoplasias del Cuello Uterino/sangre , Neoplasias del Cuello Uterino/metabolismo
5.
Pediatr Blood Cancer ; 61(7): 1168-72, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24677749

RESUMEN

BACKGROUND: Clinical outcome of papillary thyroid carcinoma (PTC) in children differs significantly from that of adults. There is no clear explanation of this difference although previous studies have demonstrated a lower prevalence of the BRAF(V600E) mutation in PTC of children. However, data are limited due to the rarity of this diagnosis. BRAF(V600E) mutation prevalence and its relationship with outcome in pediatric PTC remain unclear. PROCEDURE: BRAF(V600E) mutational status was determined in 27 PTC patients less than 22 years of age using restriction fragment length polymorphism (RFLP) analysis. The relationship between BRAF(V600E) mutation status, patient and tumor characteristics as well as progression-free survival (PFS) were analyzed. RESULTS: BRAF(V600E) was present in 63% of patients and occurred more often in male patients versus females (P = 0.033). Presence of the mutation did not correlate with any difference in extent of disease at diagnosis, tumor size, capsular invasion, vascular invasion, soft tissue invasion, or margin status. At 10 years, PFS for BRAF(V600E) positive versus negative patients was 55.5% versus 70.0%, respectively (P = 0.48). Overall survival was 100% and median follow-up was 13.9 years. CONCLUSIONS: This study of pediatric PTC demonstrates that BRAF(V600E) mutations occur in children at a rate comparable to adults. We found a correlation of BRAF(V600E) with the male gender, but no evidence that the mutation correlates with more extensive or aggressive disease. This analysis suggests that differences in disease course of PTC in children versus adults are not strongly dependent upon the presence of the BRAF(V600E) mutation.


Asunto(s)
Mutación Missense , Polimorfismo de Longitud del Fragmento de Restricción , Proteínas Proto-Oncogénicas B-raf/genética , Neoplasias de la Tiroides/genética , Neoplasias de la Tiroides/mortalidad , Adolescente , Adulto , Factores de Edad , Sustitución de Aminoácidos , Niño , Preescolar , Supervivencia sin Enfermedad , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Invasividad Neoplásica , Estudios Retrospectivos , Factores Sexuales , Tasa de Supervivencia , Neoplasias de la Tiroides/patología
6.
Semin Radiat Oncol ; 34(1): 36-44, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38105091

RESUMEN

The role of radiotherapy in the management of primary and metastatic liver malignancies has expanded in recent years due to advances such as IGRT and SBRT. MRI-guided radiotherapy (MRgRT) has arisen as an excellent option for the management of hepatocellular carcinoma, cholangiocarcinoma, and liver metastases due to the ability to combine improved hepatic imaging with conformal treatment planning paradigms like adaptive radiotherapy and advanced motion management techniques. Herein we review the data for MRgRT for liver malignancies, as well as describe workflow and technical considerations for the 2 commercially available MRgRT delivery platforms.


Asunto(s)
Neoplasias Hepáticas , Radioterapia Guiada por Imagen , Humanos , Radioterapia Guiada por Imagen/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Imagen por Resonancia Magnética/métodos
7.
Phys Imaging Radiat Oncol ; 31: 100611, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39253730

RESUMEN

Background and Purpose: Improved hounsfield-unit accuracy of on-board imaging may lead to direct-to-unit treatment approaches We aimed to demonstrate the feasibility of using only a diagnostic (dx) computed tomography (CT)-defined target pre-plan in an in silico study of simulation-free abdominal stereotactic adaptive radiotherapy (ART). Materials and Methods: Eight patients with abdominal treatment sites (five pancreatic cancer, three oligometastases) were treated using an integrated adaptive O-Ring gantry system. Each patient's target was delineated on a dxCT. The target only pre-plan served primarily to seed the ART process. During the ART session, all structures were delineated. All simulated cases were treated to 50 Gy in 5 fractions to a planning target optimization structure (PTV_OPT) to allow for dose escalation within the planning target volume. Timing of steps during this workflow was recorded. Plan quality was compared between ART treatment plans and a plan created on a CT simulation scan using the traditional planning workflow. Results: The workflow was feasible in all attempts, with organ-at-risk (OAR) constraints met in all fractions despite lack of initial OAR contours. Median absolute difference between the adapted plan and simulation CT plan for the PTV_Opt V95% was 2.0 %. Median absolute difference in the D0.5 cm3 between the adapted plan and simulation CT plan was -0.9 Gy for stomach, 1.2 Gy for duodenum, -5.3 Gy for small bowel, and 0.3 Gy for large bowel. Median end-to-end workflow time was 63 min. Conclusion: The workflow was feasible for a dxCT-defined target-only pre-plan approach to stereotactic abdominal ART.

8.
Radiother Oncol ; 200: 110473, 2024 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-39137832

RESUMEN

BACKGROUND AND PURPOSE: A retrospective evaluation of dosimetric predictors and leveraged dose-volume data for gastrointestinal (GI) toxicities for locally-advanced pancreatic cancer (LAPC) treated with daily stereotactic MRI-guided online-adaptive radiotherapy (SMART). MATERIALS AND METHODS: 147 patients with LAPC were treated with SMART at our institution between 2018 and 2021. Patients were evaluated using CTCAE V5.0 for RT-related acute (≤3 months) and late (>3 months) toxicities. Each organ at risk (OAR) was matched to a ≥ grade 2 (Gr2+) toxicity endpoint composite group. A least absolute shrinkage selector operator regression model was constructed by dose-volumes per OAR to account for OAR multicollinearity. A receiver operator curve (ROC) analysis was performed for the combined averages of significant toxicity groups to identify critical volumes per dose levels. RESULTS: 18 of 147 patients experienced Gr2+ GI toxicity. 17 Gr2+ duodenal toxicities were seen; the most significant predictor was a V33Gy odds ratio (OR) of 1.69 per cc (95 % CI 1.14-2.88). 17 Gr2+ small bowel (SB) toxicities were seen; the most significant predictor was a V33Gy OR of 1.60 per cc (95 % CI 1.01-2.53). The AUC was 0.72 for duodenum and SB. The optimal duodenal cut-point was 1.00 cc (true positive (TP): 17.8 %; true negative (TN); 94.9 %). The SB cut-point was 1.75 cc (TP: 16.7 %; TN: 94.3 %). No stomach or large bowel dose toxicity predictors were identified. CONCLUSIONS: For LAPC treated with SMART, the dose-volume threshold of V33Gy for duodenum and SB was associated with Gr2+ toxicities. These metrics can be utilized to guide future dose-volume constraints for patients undergoing upper abdominal SBRT.

9.
Int J Radiat Oncol Biol Phys ; 119(5): 1422-1428, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38580083

RESUMEN

PURPOSE: We aimed to demonstrate the clinical feasibility and safety of simulation-free hippocampal avoidance whole brain radiation therapy (HA-WBRT) in a pilot study (National Clinical Trial 05096286). METHODS AND MATERIALS: Ten HA-WBRT candidates were enrolled for treatment on a commercially available computed tomography (CT)-guided linear accelerator with online adaptive capabilities. Planning structures were contoured on patient-specific diagnostic magnetic resonance imaging (MRI), which were registered to a CT of similar head shape, obtained from an atlas-based database (AB-CT). These patient-specific diagnostic MRI and AB-CT data sets were used for preplan calculation, using NRG-CC001 constraints. At first fraction, AB-CTs were used as primary data sets and deformed to patient-specific cone beam CTs (CBCT) to give patient-matched density information. Brain, ventricle, and brain stem contours were matched through rigid translation and rotation to the corresponding anatomy on CBCT. Lens, optic nerve, and brain contours were manually edited based on CBCT visualization. Preplans were then reoptimized through online adaptation to create final, simulation-free plans, which were used if they met all objectives. Workflow tasks were timed. In addition, patients underwent CT-simulation to create immobilization devices and for prospective dosimetric comparison of simulation-free and simulation-based plans. RESULTS: Median time from MRI importation to completion of "preplan" was 1 weekday (range, 1-4). Median on-table workflow duration was 41 minutes (range, 34-70). NRG-CC001 constraints were achieved by 90% of the simulation-free plans. One patient's simulation-free plan failed a planning target volume coverage objective (89% instead of 90% coverage); this was deemed acceptable for first-fraction delivery, with an offline replan used for subsequent fractions. Both simulation-free and simulation CT-based plans otherwise met constraints, without clinically meaningful differences. CONCLUSIONS: Simulation-free HA-WBRT using online adaptive radiation therapy is feasible, safe, and results in dosimetrically comparable treatment plans to simulation CT-based workflows while providing convenience and time savings for patients.


Asunto(s)
Neoplasias Encefálicas , Tomografía Computarizada de Haz Cónico , Irradiación Craneana , Estudios de Factibilidad , Hipocampo , Imagen por Resonancia Magnética , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen , Humanos , Proyectos Piloto , Planificación de la Radioterapia Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Hipocampo/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagen , Irradiación Craneana/métodos , Órganos en Riesgo/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Radioterapia Guiada por Imagen/métodos , Tratamientos Conservadores del Órgano/métodos , Masculino
10.
Radiother Oncol ; 191: 110064, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38135187

RESUMEN

BACKGROUND AND PURPOSE: Radiation dose escalation may improve local control (LC) and overall survival (OS) in select pancreatic ductal adenocarcinoma (PDAC) patients. We prospectively evaluated the safety and efficacy of ablative stereotactic magnetic resonance (MR)-guided adaptive radiation therapy (SMART) for borderline resectable (BRPC) and locally advanced pancreas cancer (LAPC). The primary endpoint of acute grade ≥ 3 gastrointestinal (GI) toxicity definitely related to SMART was previously published with median follow-up (FU) 8.8 months from SMART. We now present more mature outcomes including OS and late toxicity. MATERIALS AND METHODS: This prospective, multi-center, single-arm open-label phase 2 trial (NCT03621644) enrolled 136 patients (LAPC 56.6 %; BRPC 43.4 %) after ≥ 3 months of any chemotherapy without distant progression and CA19-9 ≤ 500 U/mL. SMART was delivered on a 0.35 T MR-guided system prescribed to 50 Gy in 5 fractions (biologically effective dose10 [BED10] = 100 Gy). Elective coverage was optional. Surgery and chemotherapy were permitted after SMART. RESULTS: Mean age was 65.7 years (range, 36-85), induction FOLFIRINOX was common (81.7 %), most received elective coverage (57.4 %), and 34.6 % had surgery after SMART. Median FU was 22.9 months from diagnosis and 14.2 months from SMART, respectively. 2-year OS from diagnosis and SMART were 53.6 % and 40.5 %, respectively. Late grade ≥ 3 toxicity definitely, probably, or possibly attributed to SMART were observed in 0 %, 4.6 %, and 11.5 % patients, respectively. CONCLUSIONS: Long-term outcomes from the phase 2 SMART trial demonstrate encouraging OS and limited severe toxicity. Additional prospective evaluation of this novel strategy is warranted.


Asunto(s)
Neoplasias Pancreáticas , Radiocirugia , Humanos , Anciano , Neoplasias Pancreáticas/patología , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Planificación de la Radioterapia Asistida por Computador , Radiocirugia/efectos adversos
11.
Surgery ; 174(1): 108-112, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36870808

RESUMEN

The role of radiation therapy in the management of liver cancers, both primary and metastatic, has changed drastically over the past several decades. Although conventional radiation was limited by technology, the advent of advanced image-guided radiotherapy and the rise in evidence for and popularity of stereotactic body radiotherapy have expanded the indications for radiation in these two distinct disease types. Magnetic resonance imaging-guided radiation therapy, daily online adaptive radiotherapy, and proton radiotherapy are some of many modern radiotherapy techniques that allow for increasingly efficacious treatment of intrahepatic disease while simultaneously allowing for increased normal tissue sparing, including sparing of the normal liver and the radiosensitive luminal gastrointestinal tract. Modern radiation therapy should be considered along with approaches such as surgical resection and radiofrequency ablation for the management of liver cancers of diverse histologies. Herein we describe the use of modern radiotherapy in two example settings, colorectal liver metastases and intrahepatic cholangiocarcinoma, and how external beam radiotherapy provides options within multidisciplinary discussions to elect optimal patient-specific treatments.


Asunto(s)
Neoplasias de los Conductos Biliares , Colangiocarcinoma , Neoplasias Colorrectales , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Colangiocarcinoma/radioterapia , Colangiocarcinoma/cirugía , Conductos Biliares Intrahepáticos/patología , Neoplasias de los Conductos Biliares/radioterapia
12.
Phys Imaging Radiat Oncol ; 25: 100423, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36852334

RESUMEN

Contouring during adaptive radiotherapy (ART) can be a time-consuming process. This study describes the generation of patient specific contouring regions of interest (CRoI) for evaluating the high dose fall-off in stereotactic abdominal ART. An empirical equation was derived to determine the radius of a cylindrical patient specific CRoIs. These CRoIs were applied to 60 patients and their adaptive fractions (301 unique treatment plans). Out of the 301 unique treatment plans, 284 (94%) treatment plans contained the high dose fall-off within the CRoI. There was an expected predicted average timesaving of 2.9-min-per case. Patient specific CRoIs improves the efficiency of ART.

13.
Phys Imaging Radiat Oncol ; 28: 100491, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37772278

RESUMEN

Background and Purpose: Hippocampal-avoidance whole brain radiotherapy (HA-WBRT) can be a time-consuming process compared to conventional whole brain techniques, thus potentially limiting widespread utilization. Therefore, we evaluated the in silico clinical feasibility, via dose-volume metrics and timing, by leveraging a computed tomography (CT)-based commercial adaptive radiotherapy (ART) platform and workflow in order to create and deliver patient-specific, simulation-free HA-WBRT. Materials and methods: Ten patients previously treated for central nervous system cancers with cone-beam computed tomography (CBCT) imaging were included in this study. The CBCT was the adaptive image-of-the-day to simulate first fraction on-board imaging. Initial contours defined on the MRI were rigidly matched to the CBCT. Online ART was used to create treatment plans at first fraction. Dose-volume metrics of these simulation-free plans were compared to standard-workflow HA-WBRT plans on each patient CT simulation dataset. Timing data for the adaptive planning sessions were recorded. Results: For all ten patients, simulation-free HA-WBRT plans were successfully created utilizing the online ART workflow and met all constraints. The median hippocampi D100% was 7.8 Gy (6.6-8.8 Gy) in the adaptive plan vs 8.1 Gy (7.7-8.4 Gy) in the standard workflow plan. All plans required adaptation at first fraction due to both a failing hippocampal constraint (6/10 adaptive fractions) and sub-optimal target coverage (6/10 adaptive fractions). Median time for the adaptive session was 45.2 min (34.0-53.8 min). Conclusions: Simulation-free HA-WBRT, with commercially available systems, was clinically feasible via plan-quality metrics and timing, in silico.

14.
Radiother Oncol ; 178: 109428, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36455686

RESUMEN

INTRODUCTION: A kV imager coupled to a novel, ring-gantry radiotherapy system offers improved on-board kV-cone-beam computed tomography (CBCT) acquisition time (17-40 seconds) and image quality, which may improve CT radiotherapy image-guidance and enable online adaptive radiotherapy. We evaluated whether inter-observer contour variability over various anatomic structures was non-inferior using a novel ring gantry kV-CBCT (RG-CBCT) imager as compared to diagnostic-quality simulation CT (simCT). MATERIALS/METHODS: Seven patients undergoing radiotherapy were imaged with the RG-CBCT system at breath hold (BH) and/or free breathing (FB) for various disease sites on a prospective imaging study. Anatomy was independently contoured by seven radiation oncologists on: 1. SimCT 2. Standard C-arm kV-CBCT (CA-CBCT), and 3. Novel RG-CBCT at FB and BH. Inter-observer contour variability was evaluated by computing simultaneous truth and performance level estimation (STAPLE) consensus contours, then computing average symmetric surface distance (ASSD) and Dice similarity coefficient (DSC) between individual raters and consensus contours for comparison across image types. RESULTS: Across 7 patients, 18 organs-at-risk (OARs) were evaluated on 27 image sets. Both BH and FB RG-CBCT were non-inferior to simCT for inter-observer delineation variability across all OARs and patients by ASSD analysis (p < 0.001), whereas CA-CBCT was not (p = 0.923). RG-CBCT (FB and BH) also remained non-inferior for abdomen and breast subsites compared to simCT on ASSD analysis (p < 0.025). On DSC comparison, neither RG-CBCT nor CA-CBCT were non-inferior to simCT for all sites (p > 0.025). CONCLUSIONS: Inter-observer ability to delineate OARs using novel RG-CBCT images was non-inferior to simCT by the ASSD criterion but not DSC criterion.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Radioterapia Guiada por Imagen , Humanos , Estudios Prospectivos , Tomografía Computarizada de Haz Cónico/métodos , Radioterapia Guiada por Imagen/métodos , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos
15.
Clin Transl Radiat Oncol ; 39: 100577, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36718251

RESUMEN

Two abdominal patients were treated with Lattice stereotactic body radiation therapy (SBRT) using magnetic resonance guided radiation therapy (MRgRT). This is one of the first reported treatments of Lattice SBRT with the use of MRgRT. A description of the treatment approach and planning considerations were incorporated into this report. MRgRT Lattice SBRT delivered similar planning quality metrics to established dosimetric parameters for Lattice SBRT. Increased signal intensity were seen in the MRI treatments for one of the patients during the course of treatment.

16.
Clin Transl Radiat Oncol ; 39: 100561, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36594078

RESUMEN

We conducted a prospective pilot study evaluating the feasibility of same day MRI-only simulation and treatment with MRI-guided adaptive palliative radiotherapy (MAP-RT) for urgent palliative indications (NCT#03824366). All (16/16) patients were able to complete 99% of their first on-table attempted fractions, and no grades 3-5 toxicities occurred.

17.
Adv Radiat Oncol ; 8(6): 101226, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37206996

RESUMEN

Purpose: We conducted a prospective, in silico study to evaluate the feasibility of cone-beam computed tomography (CBCT)-guided stereotactic adaptive radiation therapy (CT-STAR) for the treatment of ultracentral thoracic cancers (NCT04008537). We hypothesized that CT-STAR would reduce dose to organs at risk (OARs) compared with nonadaptive stereotactic body radiation therapy (SBRT) while maintaining adequate tumor coverage. Methods and Materials: Patients who were already receiving radiation therapy for ultracentral thoracic malignancies underwent 5 additional daily CBCTs on the ETHOS system as part of a prospective imaging study. These were used to simulate CT-STAR, in silico. Initial, nonadaptive plans (PI) were created based on simulation images and simulated adaptive plans (PA) were based on study CBCTs. 55 Gy/5 fractions was prescribed, with OAR constraint prioritization over PTV coverage under a strict isotoxicity approach. PI were applied to patients' anatomy of the day and compared with daily PA using dose-volume histogram metrics, with selection of superior plans for simulated delivery. Feasibility was defined as completion of the end-to-end adaptive workflow while meeting strict OAR constraints in ≥80% of fractions. CT-STAR was performed under time pressures to mimic clinical adaptive processes. Results: Seven patients were accrued, 6 with intraparenchymal tumors and 1 with a subcarinal lymph node. CT-STAR was feasible in 34 of 35 simulated fractions. In total, 32 dose constraint violations occurred when the PI was applied to anatomy-of-the-day across 22 of 35 fractions. These violations were resolved by the PA in all but one fraction, in which the proximal bronchial tree dose was still numerically improved through adaptation. The mean difference between the planning target volume and gross total volume V100% in the PI and the PA was -0.24% (-10.40 to 9.90) and -0.62% (-11.00 to 8.00), respectively. Mean end-to-end workflow time was 28.21 minutes (18.02-50.97). Conclusions: CT-STAR widened the dosimetric therapeutic index of ultracentral thorax SBRT compared with nonadaptive SBRT. A phase 1 protocol is underway to evaluate the safety of this paradigm for patients with ultracentral early-stage NSCLC.

18.
Radiother Oncol ; 182: 109603, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36889595

RESUMEN

INTRODUCTION: We aimed to develop knowledge-based tools for robust adaptive radiotherapy (ART) planning to determine on-table adaptive DVH metric variations or planning process errors for stereotactic pancreatic ART. We developed volume-based dosimetric identifiers to identify deviations of ART plans from simulation plans. MATERIALS AND METHODS: Two patient cohorts who were treated on MR-Linac for pancreas cancer were included in this retrospective study; a training cohort and a validation cohort. All patients received 50 Gy in 5 fractions. PTV-OPT was generated by subtracting the critical organs plus a 5 mm-margin from PTV. Several metrics that potentially can identify failure-modes were calculated including PTV & PTV_OPT V95% and PTV & PTV_OPT D95%/D5%. The difference between each DVH metric in each adaptive plan with the DVH metric in simulation plan was calculated. The 95% confidence interval (CI) of the variations in each DVH metric was calculated for the patient training cohort. Variations in DVH metrics that exceeded the 95% CI for all fractions in training and validation cohort were flagged for retrospective investigation for root-cause analysis to determine their predictive power for identifying failure-modes. RESULTS: The CIs for the PTV & PTV_OPT V95% and PTV & PTV_OPT D95%/D5% were ± 13%, ± 5%, ± 0.1, ± 0.03, respectively. We estimated the positive predictive value and negative predictive value of our method to be 77% and 89%, respectively, for the training cohort, and 80% for both in the validation cohort. DISCUSSION: We developed dosimetric indicators for ART planning QA to identify population-based deviations or planning errors during online adaptive process for stereotactic pancreatic ART. This technology may be useful as an ART clinical trial QA tool and improve overall ART quality at an institution.


Asunto(s)
Neoplasias Pancreáticas , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Estudios Retrospectivos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Órganos en Riesgo , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas
19.
Clin Transl Radiat Oncol ; 38: 161-168, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36466748

RESUMEN

Purpose/Objective: Magnetic resonance-guided radiation therapy (MRgRT) utilization is rapidly expanding worldwide, driven by advanced capabilities including continuous intrafraction visualization, automatic triggered beam delivery, and on-table adaptive replanning (oART). Our objective was to describe patterns of 0.35Tesla(T)-MRgRT (MRIdian) utilization in the United States (US) among early adopters of this novel technology. Materials/Methods: Anonymized administrative data from all US MRIdian treatment systems were extracted for patients completing treatment from 2014 to 2020. Detailed treatment information was available for all MRIdian linear accelerator (linac) systems and some cobalt systems. Results: Seventeen systems at 16 centers delivered 5736 courses and 36,389 fractions (fraction details unavailable for 1223 cobalt courses), of which 21.1% were adapted. Ultra-hypofractionation (UHfx) (1-5 fractions) was used in 70.3% of all courses. At least one adaptive fraction was used for 38.5% of courses (average 1.7 adapted fractions/course), with higher oART use in UHfx dose schedules (47.7% of courses, average 1.9 adapted fractions per course). The most commonly treated organ sites were pancreas (20.7%), liver (16.5%), prostate (12.5%), breast (11.5%), and lung (9.4%). Temporal trends show a compounded annual growth rate (CAGR) of 59.6% in treatment courses delivered, with a dramatic increase in use of UHfx to 84.9% of courses in 2020 and similar increase in use of oART to 51.0% of courses. Conclusions: This is the first comprehensive study reporting patterns of utilization among early adopters of MRIdian in the US. Intrafraction MR image-guidance, advanced motion management, and increasing adoption of adaptive radiation therapy has led to a substantial transition to ultra-hypofractionated regimens. 0.35 T-MRgRT has been predominantly used to treat abdominal and pelvic tumors with increasing use of on-table adaptive replanning, which represents a paradigm shift in radiation therapy.

20.
Clin Transl Radiat Oncol ; 41: 100627, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37441543

RESUMEN

Purpose: Magnetic resonance-guided stereotactic body radiation therapy (MRgSBRT) with optional online adaptation has shown promise in delivering ablative doses to unresectable primary liver cancer. However, there remain limited data on the indications for online adaptation as well as dosimetric and longer-term clinical outcomes following MRgSBRT. Methods and Materials: Patients with unresectable hepatocellular carcinoma (HCC), cholangiocarcinoma (CCA), and combined biphenotypic hepatocellular-cholangiocarcinoma (cHCC-CCA) who completed MRgSBRT to 50 Gy in 5 fractions between June of 2015 and December of 2021 were analyzed. The necessity of adaptive techniques was evaluated. The cumulative incidence of local progression was evaluated and survival and competing risk analyses were performed. Results: Ninety-nine analyzable patients completed MRgSBRT during the study period and 54 % had planning target volumes (PTVs) within 1 cm of the duodenum, small bowel, or stomach at the time of simulation. Online adaptive RT was used in 53 % of patients to correct organ-at-risk constraint violation and/or to improve target coverage. In patients who underwent adaptive RT planning, online replanning resulted in superior target coverage when compared to projected, non-adaptive plans (median coverage ≥ 95 % at 47.5 Gy: 91 % [IQR: 82-96] before adaptation vs 95 % [IQR: 87-99] after adaptation, p < 0.01). The median follow-up for surviving patients was 34.2 months for patients with HCC and 10.1 months for patients with CCA/cHCC-CCA. For all patients, the 2-year cumulative incidence of local progression was 9.8 % (95 % CI: 1.5-18 %) for patients with HCC and 9.0 % (95 % CI: 0.1-18) for patients with CCA/cHCC-CCA. Grade 3 through 5 acute and late clinical gastrointestinal toxicities were observed in < 10 % of the patients. Conclusions: MRgSBRT, with the option for online adaptive planning when merited, allows delivery of ablative doses to primary liver tumors with excellent local control with acceptable toxicities. Additional studies evaluating the efficacy and safety of MRgSBRT in the treatment of primary liver cancer are warranted.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA