Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
EJNMMI Res ; 11(1): 50, 2021 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-34052912

RESUMEN

BACKGROUND: Surgically induced nerve damage is a common but debilitating side effect in oncological surgery. With the aim to use fluorescence guidance to enable nerve-sparing interventions in future surgery, a fluorescent tracer was developed that specifically targets myelin protein zero (P0). RESULTS: Truncated homotypic P0 protein-based peptide sequences were C-terminally functionalized with the far-red cyanine dye Cy5. The lead compound Cy5-P0101-125 was selected after initial solubility, (photo)physical and in vitro evaluation (including P0-blocking experiments). Cy5-P0101-125 (KD = 105 ± 17 nM) allowed in vitro and ex vivo P0-related staining. Furthermore, Cy5-P0101-125  enabled in vivo fluorescence imaging of the Sciatic nerve in mice after local intravenous (i.v.) administration and showed compatibility with a clinical fluorescence laparoscope during evaluation in a porcine model undergoing robot-assisted surgery. Biodistribution data revealed that i.v. administered [111In]In-DTPA-P0101-125 does not enter the central nervous system (CNS). CONCLUSION: P0101-125 has proven to be a potent nerve-specific agent that is able to target P0/myelin under in vitro, ex vivo, and in vivo conditions without posing a threat for CNS-related toxicity.

2.
J Nucl Med ; 61(2): 234-241, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31481575

RESUMEN

Prostate cancer surgery is currently being revolutionized by the use of prostate-specific membrane antigen (PSMA)-targeted radiotracers, for example, 99mTc-labeled PSMA tracer analogs for radioguided surgery. The purpose of this study was to develop a second-generation 99mTc-labeled PSMA-targeted tracer incorporating a fluorescent dye. Methods: Several PSMA-targeted hybrid tracers were synthesized: glutamic acid-urea-lysine (EuK)-Cy5-mas3, EuK-(SO3)Cy5-mas3, EuK-Cy5(SO3)-mas3, EuK-(Ar)Cy5-mas3, and EuK-Cy5(Ar)-mas3; the Cy5 dye acts as a functional backbone between the EuK targeting vector and the 2-mercaptoacetyl-seryl-seryl-seryl (mas3) chelate to study the dye's interaction with PSMA's amphipathic entrance funnel. The compounds were evaluated for their photophysical and chemical properties and PSMA affinity. After radiolabeling with 99mTc, we performed in vivo SPECT imaging, biodistribution, and fluorescence imaging on BALB/c nude mice with orthotopically transplanted PC346C tumors. Results: The dye composition influenced the photophysical properties (brightness range 0.3-1.5 × 104 M-1 × cm-1), plasma protein interactions (range 85.0% ± 2.3%-90.7% ± 1.3% bound to serum, range 76% ± 0%-89% ± 6% stability in serum), PSMA affinity (half-maximal inhibitory concentration [IC50] range 19.2 ± 5.8-175.3 ± 61.1 nM) and in vivo characteristics (tumor-to-prostate and tumor-to-muscle ratios range 0.02 ± 0.00-154.73 ± 28.48 and 0.46 ± 0.28-5,157.50 ± 949.17, respectively; renal, splenic, and salivary retention). Even though all tracer analogs allowed tumor identification with SPECT and fluorescence imaging, 99mTc-EuK-(SO3)Cy5-mas3 had the most promising properties (e.g., half-maximal inhibitory concentration, 19.2 ± 5.8, tumor-to-muscle ratio, 5,157.50 ± 949.17). Conclusion: Our findings demonstrate the intrinsic integration of a fluorophore in the pharmacophore in PSMA-targeted small-molecule tracers. In this design, having 1 sulfonate on the indole moiety adjacent to EuK (99mTc-EuK-(SO3)Cy5-mas3) yielded the most promising tracer candidate for imaging of PSMA.


Asunto(s)
Antígenos de Superficie/química , Antígenos de Superficie/metabolismo , Carbocianinas/química , Carbocianinas/farmacocinética , Colorantes/química , Colorantes/farmacocinética , Glutamato Carboxipeptidasa II/química , Glutamato Carboxipeptidasa II/metabolismo , Animales , Línea Celular Tumoral , Transformación Celular Neoplásica , Humanos , Ratones , Trazadores Radiactivos , Distribución Tisular , Tomografía Computarizada de Emisión de Fotón Único
3.
ACS Infect Dis ; 5(7): 1160-1168, 2019 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-31016979

RESUMEN

There is a need to develop diagnostic and analytical tools that allow noninvasive monitoring of bacterial growth and dissemination in vivo. For such cell-tracking studies to hold translational value to controlled human infections, in which volunteers are experimentally colonized, they should not require genetic modification, and they should allow tracking over a number of replication cycles. To gauge if an antimicrobial peptide tracer, 99mTc-UBI29-41-Cy5, which contains both a fluorescent and a radioactive moiety, could be used for such in vivo bacterial tracking, we performed longitudinal imaging of a thigh-muscle infection with 99mTc-UBI29-41-Cy5-labeled Staphylococcus aureus. Mice were imaged using SPECT and fluorescence-imaging modalities at various intervals during a 28 h period. Biodistribution analyses were performed to quantitate radioactivity in the abscess and other tissues. SPECT and fluorescence imaging in mice showed clear retention of the 99mTc-UBI29-41-Cy5-labeled bacteria following inoculation in the thigh muscle. Despite bacterial replication, the signal intensity in the abscess only modestly decreased within a 28 h period: 52% of the total injected radioactivity per gram of tissue (%ID/g) at 4 h postinfection (pi) versus 44%ID/g at 28 h pi (15% decrease). After inoculation, a portion of the bacteria disseminated from the abscess, and S. aureus cultures were obtained from radioactive urine samples. Bacterial staining with 99mTc-UBI29-41-Cy5 allowed noninvasive bacterial-cell tracking during a 28 h period. Given the versatility of the presented bacterial-tracking method, we believe that this concept could pave the way for precise imaging capabilities during controlled-human-infection studies.


Asunto(s)
Carbocianinas/química , Compuestos de Organotecnecio/administración & dosificación , Fragmentos de Péptidos/administración & dosificación , Infecciones Estafilocócicas/diagnóstico por imagen , Staphylococcus aureus/patogenicidad , Animales , Humanos , Ratones , Imagen Molecular , Compuestos de Organotecnecio/química , Fragmentos de Péptidos/química , Staphylococcus aureus/crecimiento & desarrollo , Muslo/diagnóstico por imagen , Distribución Tisular , Tomografía Computarizada de Emisión de Fotón Único , Orina/química , Orina/microbiología
4.
ACS Omega ; 4(7): 12438-12448, 2019 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-31460363

RESUMEN

Hybrid tracers containing both fluorescent and radioactive imaging labels have demonstrated clinical potential during sentinel lymph node procedures. To combine these two labels on a single targeting vector that allows tumor-targeted imaging, end-labeling strategies are often applied. For αvß3-integrin-targeting hybrid tracers, providing an excellent model for evaluating tracer development strategies, end-labeling-based synthesis provides a rather cumbersome synthesis strategy. Hence, the aim of this study was to investigate the use of heterobifunctional cyanine dyes in a click-chemistry-based synthesis strategy for RGD-based hybrid tracers. The triazole-based hybrid tracers DTPA.DBCO.N 3 (SO 3 )-Cy5-c[RGDyK] and DTPA.BCN.N 3 (SO 3 )-Cy5-c[RGDyK] were obtained in fewer steps than DTPA-Lys(Cy5(SO 3 )methyl)-Cys-c[RGDyK] and had partition coefficients of log P (o/w) = -2.55 ± 0.10, -1.45 ± 0.03, and -2.67 ± 0.12, respectively. Both tracers were chemically stable, and the brightnesses of DTPA.DBCO.N 3 (SO 3 )-Cy5-c[RGDyK] and DTPA.BCN.N 3 (SO 3 )-Cy5-c[RGDyK] were, respectively, 23 × 103 and 40 × 103 M-1 cm-1; lower than that of the reference tracer DTPA-Lys(Cy5(SO 3 )methyl)-Cys-c[RGDyK] (50 × 103 M-1 cm-1). Assessment of serum protein binding revealed no statistically significant difference (44 ± 2 and 40 ± 2% bound for DTPA.DBCO.N 3 (SO 3 )-Cy5-c[RGDyK] and DTPA.BCN.N 3 (SO 3 )-Cy5-c[RGDyK], respectively; 36 ± 5% bound for DTPA-Lys(Cy5(SO 3 )methyl)-Cys-c[RGDyK]; p > 0.05). DTPA.DBCO.N 3 (SO 3 )-Cy5-c[RGDyK] (K D = 17.5 ± 6.0) had a statistically significantly higher affinity than the reference compound DTPA-Lys(Cy5(SO 3 )methyl)-Cys-c[RGDyK] (K D = 30.3 ± 5.7; p < 0.0001), but DTPA.BCN.N 3 (SO 3 )-Cy5-c[RGDyK] had a statistically significantly lower affinity (K D = 76.5 ± 18.3 nM; p < 0.0001). Both [ 111 In]DTPA.DBCO.N 3 (SO 3 )-Cy5-c[RGDyK] and [ 111 In]DTPA.BCN.N 3 (SO 3 )-Cy5-c[RGDyK] enabled in vivo visualization of the 4T1 tumor via fluorescence and single-photon emission computed tomography (SPECT) imaging. Biodistribution data (% ID/g) revealed a significant increase in nonspecific uptake in the kidney, liver, and muscle for both [ 111 In]DTPA.DBCO.N 3 (SO 3 )-Cy5-c[RGDyK] and [ 111 In]DTPA.BCN.N 3 (SO 3 )-Cy5-c[RGDyK]. As a result of the higher background activity, the tumor-to-background ratio of the click-labeled RGD analogues was twofold lower compared to the end-labeled reference compound. The use of click chemistry labeling did not yield a pronounced negative effect on serum protein binding, in vitro stability, and receptor affinity; and tumors could still be visualized using SPECT and fluorescence imaging. However, quantitative in vivo biodistribution data suggest that the triazole and strained cyclooctyne moieties associated with this type of click chemistry negatively influence the pharmacokinetics of RGD peptides. Nevertheless, the design might still hold promise for other targets/targeting moieties.

5.
J Nucl Med ; 59(6): 986-992, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29449447

RESUMEN

The potential of receptor-mediated fluorescence-based image-guided surgery tracers is generally linked to the near-infrared emission profile and good-manufacturing-production availability of fluorescent dyes. Surprisingly, little is known about the critical interaction between the structural composition of the dyes and the pharmacokinetics of the tracers. In this study, a dual-modality tracer design was used to systematically and quantitatively evaluate the influence of elongation of the polymethine chain in a fluorescent cyanine dye on the imaging potential of a targeted tracer. Methods: As a model system, the integrin marker αvß3 was targeted using arginylglycylaspartisc acid [RGD]-based vectors functionalized with a 111In-diethylenetriaminepentaacetic acid (DTPA) chelate and a fluorescent dye: (Cy3-(SO3)methyl-COOH [emission wavelength (λem), 580 nm], Cy5-(SO3)methyl-COOH [λem, 680 nm], or Cy7-(SO3)methyl-COOH [λem, 780 nm]). Tracers were analyzed for differences in photophysical properties, serum protein binding, chemical or optical stability, and signal penetration through tissue. Receptor affinities were evaluated using saturation and competition experiments. In vivo biodistribution (SPECT imaging and percentage injected dose per gram of tissue) was assessed in tumor-bearing mice and complemented with in vivo and ex vivo fluorescence images obtained using a clinical-grade multispectral fluorescence laparoscope. Results: Two carbon-atom-step variations in the polymethine chain of the fluorescent cyanine dyes were shown to significantly influence the chemical and photophysical characteristics (e.g., stability, brightness, and tissue penetration) of the hybrid RGD tracers. DTPA-Cy5-(SO3)methyl-COOH-c[RGDyK] structurally outperformed its Cy3 and Cy7 derivatives. Radioactivity-based evaluation of in vivo tracer pharmacokinetics yielded the lowest nonspecific uptake and highest tumor-to-background ratio for DTPA-Cy5-(SO3)methyl-COOH-c[RGDyK] (13.2 ± 1.7), with the Cy3 and Cy7 analogs trailing at respective tumor-to-background ratios of 5.7 ± 0.7 and 4.7 ± 0.7. Fluorescence-based assessment of tumor visibility revealed a similar trend. Conclusion: These findings underline that variations in the polymethine chain lengths of cyanine dyes have a profound influence on the photophysical properties, stability, and in vivo targeting capabilities of fluorescent imaging tracers. In a direct comparison, the intermediate-length dye (Cy5) yielded a superior c[RGDyK] tracer, compared with the shorter (Cy3) and longer (Cy7) analogs.


Asunto(s)
Carbocianinas/química , Colorantes Fluorescentes/química , Oligopéptidos/química , Oligopéptidos/farmacocinética , Imagen Óptica , Cirugía Asistida por Computador , Animales , Línea Celular Tumoral , Humanos , Ratones , Trazadores Radiactivos , Distribución Tisular , Tomografía Computarizada de Emisión de Fotón Único
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA