Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Photomed Laser Surg ; 36(3): 151-161, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29131710

RESUMEN

BACKGROUND: During the last years, fluorescence spectroscopy has been used as a potential tool for the evaluation and characterization of tissues with different disease conditions due to its low cost, high sensitivity, and minimally or noninvasive character. OBJECTIVE: In this study, fluorescence spectroscopy was used to study 19 paraffin blocks containing human liver tissue from biopsies. METHODS AND RESULTS: All samples were previously analyzed by two senior pathologists in a single-blind trial. After their evaluation, four liver samples were classified as nonfibrosis (F0), four as initial fibrosis (F1-F2), four as advanced fibrosis (F3), and six as cirrhosis (F4). The fluorescence was induced at different wavelengths as follows: 330, 365, and 405 nm using a portable fiber-optic system. The fluorescence spectra were recorded in the range of 400-750 nm. A distinctive correlation between the shape of each spectrum and the level of fibrosis in the liver sample was detected. A multi-variate statistical analysis based on principal component analysis followed by linear discrimination analysis was applied to develop algorithms able to distinguish different stages of fibrosis based on the characteristics of fluorescence spectra. Pairwise comparisons were performed: F0 versus F1-F2, F1-F2 versus F3, F3 versus F4, and F1-F2 versus F4. The algorithms applied to each set of data yielded values of sensitivity and specificity that were higher than 90% and 95%, respectively, in all the analyzed cases. CONCLUSIONS: With this study, it is concluded that fluorescence spectroscopy can be used as a complementary tool for the assessment of liver fibrosis in liver tissue samples, which sets the stage for subsequent clinical trials.


Asunto(s)
Cirrosis Hepática/diagnóstico , Espectrometría de Fluorescencia , Adulto , Femenino , Humanos , Cirrosis Hepática/etiología , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
2.
Photomed Laser Surg ; 34(3): 108-15, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26890993

RESUMEN

OBJECTIVE: In this work an irradiance and temperature controlled in-vitro system for conducting investigations in PDT and phototherapy is presented. BACKGROUND DATA: The development of new light sources has caused a considerable increase in research and application of several photodynamic (PDT) therapeutic methods, as well as other light-based therapeutic techniques. However, further work is needed to fully understand and elucidate the mechanisms as well as to increase the effectiveness of PDT. Nowadays, there are no commercial systems to perform automated light exposure experiments with cultured cells. Also, there are very few reports of similar photoirradiation systems. MATERIALS AND METHODS: The system is composed of 24 independent light-emitting diodes that can be used to irradiate separate wells in a microwell plate. The system includes a module to measure changes in temperature within each irradiated well without contact. The light sources are placed on a plate that can easily be changed in order to irradiate at different wavelengths. The performance of the system is fully controlled with a computer, and all the experimental data are properly recorded. RESULTS: The design, construction, operation, and a full characterization of the system are presented. CONCLUSIONS: A novel fully automated photoirradiation system has been developed. The system allows the design of the experiments in this area with precise dosimetry, temperature, and irradiation regime controls reducing manipulation of the samples and saving time.


Asunto(s)
Línea Celular Tumoral/efectos de la radiación , Fototerapia/métodos , Neoplasias de la Próstata/patología , Animales , Automatización de Laboratorios , Supervivencia Celular/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Técnicas In Vitro , Luz , Masculino , Ratones , Dosis de Radiación , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA