RESUMEN
PURPOSE: This review explores mathematical models, blinking characterization, and non-invasive techniques to enhance understanding and refine clinical interventions for ocular conditions, particularly for contact lens wear. METHODS: The review evaluates mathematical models in tear film dynamics and their limitations, discusses contact lens wear models, and highlights computational mechanical models. It also explores computational techniques, customization of models based on individual blinking dynamics, and non-invasive diagnostic tools like high-speed cameras and advanced imaging technologies. RESULTS: Mathematical models provide insights into tear film dynamics but face challenges due to simplifications. Contact lens wear models reveal complex ocular physiology and design aspects, aiding in lens development. Computational mechanical models explore eye biomechanics, often integrating tear film dynamics into a Multiphysics framework. While different computational techniques have their advantages and disadvantages, non-invasive tools like OCT and thermal imaging play a crucial role in customizing these Multiphysics models, particularly for contact lens wearers. CONCLUSION: Recent advancements in mathematical modeling and non-invasive tools have revolutionized ocular health research, enabling personalized approaches. The review underscores the importance of interdisciplinary exploration in the Multiphysics approach involving tear film dynamics and biomechanics for contact lens wearers, promoting advancements in eye care and broader ocular health research.
Asunto(s)
Lentes de Contacto , Lágrimas , Humanos , Lágrimas/fisiología , Lágrimas/metabolismo , Ajuste de Prótesis , Parpadeo/fisiología , Síndromes de Ojo Seco/fisiopatología , Síndromes de Ojo Seco/metabolismo , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/terapia , Simulación por Computador , Modelos Teóricos , Fenómenos BiomecánicosRESUMEN
OBJECTIVE: To assess the intrarater repeatability of the measurements of tear meniscus height (TMH), noninvasive keratograph tear break-up time (NIKBUTs), and ocular redness measurements obtained with the Keratograph 5M (K5M) in a sample of soft silicone hydrogel contact lens (CL) wearers over 15 days. METHODS: Prospective study over two consecutive weeks. Three measurements of TMH, NIKBUTs (NIKBUT first and NIKBUT average), and ocular redness were obtained in different sessions; the first day (baseline, at 8 hr of wear, and after lens removal) and the last day of wear-15th day (at 8 hr of wear and after lens removal). The repeatability of measurements were assessed by two intraclass correlation coefficient (ICC) forms; single measurement [ICC (2,1)] and multiple measurements (k=3) [ICC (2, k)]. RESULTS: Sixty-four eyes were analyzed. The repeatability of baseline TMH [ICC (2,1) greater than 0.90; coefficient of repeatability (CR)=0.06 mm] and after and during CL wear [ICC (2,k) greater than 0.90; CR≤0.07 mm] were excellent. The repeatability of baseline NIKBUT average [ICC (2,k)=0.89 (0.82-0.93); CR=6.07 sec] was maintained after CL removal but was poorer during CL wear. The repeatability of baseline NIKBUT first [ICC (2,k) =0.80 (0.69-0.87); CR=8.74 sec] was maintained after CL removal and during CL wear at moderate-good level. CONCLUSIONS: Intrarater repeatability of TMH, NIKBUTs, and ocular redness performed by K5M after CL wear remains stable when three measurements are performed. However, intrarater repeatability during CL wear decreased only for NIKBUT average and was not affected by time of use (15 days).
Asunto(s)
Lentes de Contacto Hidrofílicos , Córnea/fisiopatología , Topografía de la Córnea/instrumentación , Miopía/terapia , Lágrimas/fisiología , Adulto , Femenino , Humanos , Hiperemia/fisiopatología , Masculino , Miopía/fisiopatología , Estudios Prospectivos , Ajuste de Prótesis , Reproducibilidad de los Resultados , Lágrimas/química , Adulto JovenRESUMEN
OBJECTIVE: To assess the effects of a short period of orthokeratology (OK) on corneal sub-basal nerve plexus (SBNP) morphology and corneal sensitivity. METHODS: Measurements were made in 56 right eyes of 56 subjects with low-to-moderate myopia who wore 2 OK lens designs (Group CRT: HDS 100 Paragon CRT, n=35; Group SF: Seefree; n=21) for a period of 1 month and in 15 right eyes of noncontact lens wearers as controls. The variables determined in each participant were corneal sensitivity using a Cochet-Bonnet esthesiometer and 12 SBNP variables determined on laser scanning confocal microscopy images using 3 different software packages. Correlation between SBNP architecture and corneal sensitivity was also examined. RESULTS: Few changes were observed over the 1-month period in the variables examined in the OK treatment and control groups. However, significant reductions were detected over time in the number of nerves in the central cornea in the groups CRT (P=0.029) and SF (P=0.043) and in central corneal sensitivity in CRT (P=0.047) along with significant increases in central and midperipheral corneal Langerhans cell counts in SF (P=0.001 and 0.048, respectively). CONCLUSIONS: This study provides useful data to better understand the anatomical changes induced by OK in corneal SBNP. The different response observed to the 2 OK lens designs requires further investigation.
Asunto(s)
Córnea/inervación , Córnea/fisiología , Miopía/terapia , Red Nerviosa/anatomía & histología , Nervio Oftálmico/anatomía & histología , Procedimientos de Ortoqueratología , Adulto , Análisis de Varianza , Estudios de Casos y Controles , Sensibilidad de Contraste/fisiología , Femenino , Humanos , Masculino , Nervio Oftálmico/fisiología , Procedimientos de Ortoqueratología/efectos adversos , Procedimientos de Ortoqueratología/métodos , Estudios Prospectivos , Adulto JovenRESUMEN
PURPOSE: To examine the effects of one year of overnight orthokeratology (OK) treatment on the sub-basal nerve plexus (SBNP) and corneal sensitivity and to assess the reversibility of these effects one month after treatment interruption. METHODS: Thirty-two subjects with low-moderate myopia underwent OK treatment for one year. Fifteen non-contact lens wearers served as controls. At the time points baseline, one year of treatment, and one month after removing the OK lenses, two tests were conducted: corneal sensitivity (Cochet-Bonnet esthesiometer) and SBNP imaging by in vivo confocal microscopy. RESULTS: In participants wearing OK lenses, significant reductions over the year were produced in SBNP nerve density (P=0.001 and P=0.006) and number of nerves (P<0.001 and P=0.001) in the central and mid-peripheral cornea, respectively. Differences over the year were also detected in central objective tortuosity (P=0.002). After lens removal, baseline values of nerve density (P=0.024 and P=0.001) and number of nerves (P=0.021 and P<0.001) for the central and mid-peripheral cornea, respectively, were not recovered. At one month post-treatment, a difference was observed from one-year values in central corneal sensitivity (P=0.045) and mid-peripheral Langerhans cell density (P=0.033), and from baseline in mid-peripheral objective tortuosity (P=0.049). Direct correlation was detected at one year between nerve density and tortuosity both in the central (P<0.01; r=0.69) and mid-peripheral cornea (P<0.01; r=0.76). CONCLUSIONS: Long-term OK treatment led to reduced SBNP nerve density and this was directly correlated with corneal tortuosity. After one month of treatment interruption, nerve density was still reduced.
Asunto(s)
Lentes de Contacto , Córnea , Miopía/terapia , Red Nerviosa/anatomía & histología , Nervio Oftálmico/anatomía & histología , Procedimientos de Ortoqueratología/efectos adversos , Adulto , Estudios de Casos y Controles , Sensibilidad de Contraste/fisiología , Córnea/inervación , Córnea/fisiología , Femenino , Humanos , Masculino , Microscopía Confocal , Adulto JovenRESUMEN
This study presents a finite element analysis to model ocular biomechanics and the interactions between the human eye and contact lenses in the closed-eye condition. The closed-eye state, where the eyelids are fully shut, presents challenges for experimental measurements due to the invasive nature of accessing and analysing the contact lens and corneal interface, making simulation tools valuable for accurate characterisation. The primary objective of this study was to examine how CLs fold and twist and their impact on the cornea when the eye is closed. The secondary aim of this study was to assess how crucial contact lens parameters (Young's modulus, base curve, and diameter) influence corneal stress distribution and the overall fit of the lens on the eye. The findings show that increasing Young's modulus significantly reduces corneal stress and promotes uniform stress distribution, making it the most influential factor for wearer comfort and safety. While base curve and diameter variations primarily affect contact area, their impact on stress distribution is minimal. This research provides insights for improving contact lens design and enhancing safety for contact lens wearers.
RESUMEN
BACKGROUND: Childhood myopia represents a global concern with increasing prevalence in recent decades. Lifestyle factors significantly impact myopia. AIM: To evaluate lifestyle factors in myopic children from a metropolitan area in Europe. METHODS: This was a descriptive study including myopic subjects aged 4-18 years. Patient demographic and clinical data were collected, including cycloplegic refraction in spherical equivalent refraction (SER) and axial length (AL). In addition, a questionnaire on lifestyle factors was conducted between September 2022 and April 2023. RESULTS: A total of 321 myopic children were included, aged 10.72 ± 3.05 years, of whom 51.4% were boys, with SER -2.25 ± 1.9 D and AL 24.54 ± 0.98 mm. The mean age of myopia onset was 7.69 ± 3.05 years. A total of 59.8% had family history of myopia. Those children who had <2 h/day of screen time (on weekdays) presented SER -2 ± 1.91 D, compared to those who had >2 h/day, SER: -2.50 ±1.88 D (p = 0.009). Children who spent <2 h/day doing near work after school were less myopic compared to those who spent >2 h/day (SER: -1.75 ± 1.83 vs. SER: -2.75 ± 1.82, respectively, p = 0.03). However, no significant association was observed between SER and AL and time spent outdoors nor between SER and AL and academic performance (p > 0.05). CONCLUSIONS: Screen time and near-work time appear to be lifestyle factors related to myopia.
RESUMEN
BACKGROUND: To compare keratocyte density after mechanical microkeratome LASIK (MK-LASIK) and femtosecond-laser assisted LASIK (FS-LASIK). METHODS: We performed a prospective study of myopic patients that underwent MK-LASIK or FS-LASIK. We measured keratocyte density 3 and 15 months, and 3-5 years after the surgery using confocal microscopy, and compared them with healthy, non-operated corneas. RESULTS: Thirty-one eyes were included in the FS-LASIK group, 30 in the MK-LASIK group and 28 in the control group. Three months postoperatively, there was an increase in the keratocyte population of the whole cornea, mainly due to the mid and posterior stromal layers, in both treatment groups. It was also increased in the stromal bed after MK-LASIK, but not after FS-LASIK. In both groups, this was followed by a normalisation and stabilisation of cell density in those deeper layers 15 months after the surgery. Keratocyte density in the flap and stromal bed was decreased 15 months after FS- and MK-LASIK compared to 3 months postoperatively and compared to controls. It seemed to remain stable thereafter. In spite of this decrease, the average cell density throughout the cornea was not decreased compared to controls at any time point. CONCLUSION: We found a reorganization of keratocytes density after LASIK, with an initial increase, followed by a decrease in the stromal flap and stromal bed 15 months postoperatively, and stable from then onwards, but still maintaining normal average densities in the total cornea. There were no differences between MK- and FS-LASIK.
Asunto(s)
Queratocitos de la Córnea/patología , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Adulto , Recuento de Células , Paquimetría Corneal , Sustancia Propia/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Microscopía Confocal , Miopía/fisiopatología , Estudios Prospectivos , Colgajos Quirúrgicos/patología , Agudeza Visual/fisiología , Adulto JovenRESUMEN
This systematic review examines the use of eye-tracking devices in optometry, describing their main characteristics, areas of application and metrics used. Using the PRISMA method, a systematic search was performed of three databases. The search strategy identified 141 reports relevant to this topic, indicating the exponential growth over the past ten years of the use of eye trackers in optometry. Eye-tracking technology was applied in at least 12 areas of the field of optometry and rehabilitation, the main ones being optometric device technology, and the assessment, treatment, and analysis of ocular disorders. The main devices reported on were infrared light-based and had an image capture frequency of 60 Hz to 2000 Hz. The main metrics mentioned were fixations, saccadic movements, smooth pursuit, microsaccades, and pupil variables. Study quality was sometimes limited in that incomplete information was provided regarding the devices used, the study design, the methods used, participants' visual function and statistical treatment of data. While there is still a need for more research in this area, eye-tracking devices should be more actively incorporated as a useful tool with both clinical and research applications. This review highlights the robustness this technology offers to obtain objective information about a person's vision in terms of optometry and visual function, with implications for improving visual health services and our understanding of the vision process.
RESUMEN
OBJECTIVE: To describe corneal confocal microscopy findings in patients with long COVID-19 with persistent symptoms over 20 months after SARS-CoV-2 infection. DESIGN: A descriptive cross-sectional study that included a total of 88 patients; 60 patients with Long COVID-19 and 28 controls. Long COVID-19 diagnosis was established according to the World Health Organization criteria. Corneal confocal microscopy using a Heidelberg Retina Tomograph II (Heidelberg Engineering, Heidelberg, Germany) was performed to evaluate sub-basal nerve plexus morphology (corneal nerve fiber density, nerve fiber length, nerve branch density, nerve fiber total branch density, nerve fiber area, and nerve fiber width). Dendritic cell density and area, along with microneuromas and other morphological changes of the nerve fibers were recorded. RESULTS: Long COVID-19 patients presented with reduced corneal nerve density and branch density as well as shorter corneal nerves compared to the control group. Additionally, Long COVID-19 patients showed an increased density of dendritic cells also with a greater area than that found in the control group of patients without systemic diseases. Microneuromas were detected in 15% of Long COVID-19 patients. CONCLUSIONS: Long COVID-19 patients exhibited altered corneal nerve parameters and increased DC density over 20 months after acute SARS-CoV-2 infection. These findings are consistent with a neuroinflammatory condition hypothesized to be present in patients with Long COVID-19, highlighting the potential role of corneal confocal microscopy as a promising noninvasive technique for the study of patients with Long COVID-19.
RESUMEN
PURPOSE: To investigate the possible risk factors for treatment failure in patients who had undergone Preserflo Microshunt (PMS) implantation, using anterior-segment optical coherence tomography (AS-OCT) to analyze the internal structures of the bleb. METHODS: The PMS blebs of 54 patients were evaluated with AS-OCT. A mathematical model was used to calculate the total filtering surface of the episcleral fluid cavity (EFC) and the hydraulic conductivity (HC) of the bleb wall. Complete and qualified success were defined as IOP between 6 and 17 mmHg with or without glaucoma medication. The relation between baseline characteristics and probability of bleb success was analyzed by bivariate and multivariate logistic regression. The main outcome measures were mean bleb wall thickness (BWT), reflectivity (BWR), HC, mean horizontal and vertical diameter and total filtering surface (TFS) of the EFC. RESULTS: Blebs from 74% patients were considered as complete success and 26% as failure. BWR and BWT increased linearly up to the first year in both groups. BWR was higher in the group failure (p = 0.02) and BWT in the group success (p<0.001). EFC was wider and shorter in the success group (p = 0.009, p = 0.03). Higher TFS showed a negative correlation with IOP (r = -0.4, p = 0.002). Higher baseline IOP was associated with success of PMS by multivariate analysis (p = 0.01). Mean HC, 0.034 ± 0.008 (µL/min)/mm2/mmHg, was negatively correlated with bleb surface (r = -0.5, p<0.0001) and wall´s thickness (r = -0.3, p = 0.01). CONCLUSIONS: AS-OCT revealed that successful PMS blebs could show either thick hyporreflective walls or wide filtering surfaces with thin capsules. A higher baseline IOP increased the probability of surgical success.
Asunto(s)
Glaucoma , Trabeculectomía , Humanos , Trabeculectomía/métodos , Segmento Anterior del Ojo , Presión Intraocular , Conjuntiva/cirugía , Glaucoma/cirugía , Tomografía de Coherencia Óptica/métodosRESUMEN
PURPOSE: To analyse the effect of femtosecond laser-assisted in situ keratomileusis (FS-LASIK) on the electrical response of retinal ganglion cells using pattern electroretinography (pERG). METHODS: This was a longitudinal, prospective, observational pilot study. We included consecutive myopic patients who underwent FS-LASIK to correct up to 6 dioptres of myopia and up to 2 dioptres of astigmatism. Patients with excessive blinking or tearing and those with Snellen uncorrected visual acuity less than 0.9 dec on postop day 1 were excluded. Diopsys NOVA® (Diopsys Inc., NJ) pERG records, using high- and low-contrast patterns, were obtained 16 h and 1 month after FS-LASIK was performed. Magnitude (µV), Magnitude D (µV), Magnitude D/Magnitude ratio and signal-to-noise ratio (dB) were analysed. Wilcoxon test for nonparametric paired data was employed. RESULTS: pERG data from 24 eyes were analysed from 24 patients who underwent FS-LASIK. Mean age was 35.79 ± 9.86 years. Mean preoperative refraction was -2.69 ± 7.6 D (spherical) and -0.38 ± 0.40 D (cylinder). Mean surgical time was 56.88 ± 7.6 s. No statistically significant differences were obtained for any of the studied parameters when comparing 16 h with 1 month after FS-LASIK, with the exception of Magnitude with low contrast, which increased from 1.21 ± 0.2 to 1.39 ± 0.29 µV at 16 h and 1 month postoperatively, respectively (p = 0.03). CONCLUSIONS: FS-LASIK seems to induce a mild and transitory defect in retinal ganglion cell function. Only a mild decrease was detected in the magnitude value for low-contrast stimuli when pERG was performed 16 h postoperatively, and it returned to normal 1 month after surgery.
Asunto(s)
Astigmatismo , Queratomileusis por Láser In Situ , Miopía , Adulto , Humanos , Láseres de Excímeros/uso terapéutico , Persona de Mediana Edad , Miopía/cirugía , Estudios Prospectivos , Refracción Ocular , Células Ganglionares de la Retina , Resultado del TratamientoRESUMEN
Background: Due to the importance of choroidal thickness in the development of myopia, this study examined the effect of MiSight contact lenses (CLs) on the choroidal thickness of myopic children and the differences between responders and non-responders to the treatment with these CLs. Methods: A total of 41 myopic children were fitted with MiSight CLs and 33 with single-vision spectacles. They were followed up for two years. Subfoveal choroidal thickness and choroidal thickness 1 and 3 mm temporal and nasal to the fovea were measured by OCT at baseline and one and two years after the treatment. Differences in all the choroidal thickness parameters were assessed in each group over time. Patients from the MiSight group were classified based on a specific range of changes in axial length at the end of the second year of treatment as "responders" (AL change < 0.22 mm/per year) and "non-responders", and the choroidal thickness of both groups was analyzed. Results: The subfoveal choroidal thickness of the MiSight and single-vision spectacle groups did not show any changes over time. Wearing MiSight CLs induced relative choroidal thickening in the responder group in the first year of treatment. Conclusion: Choroidal thickness might work as a predictor of the effectiveness of MiSight in myopia treatment.
RESUMEN
In vivo corneal confocal microscopy (IVCM) is a non-invasive ophthalmic imaging technique that provides images of the cornea at the cellular level. Despite the uses in ocular surface pathologies, in the last decades IVCM has been used to provide more knowledge in refractive surgery wound healing, in neuropathies diagnosis, etc. The observation of the corneal cells, both normal and inflammatory, and the possibility of quantification of the corneal nerve density with manual or automated tools, makes IVCM have a significant potential to improve the diagnosis and prognosis in several systemic and corneal conditions.
RESUMEN
PURPOSE: To investigate which baseline factors are predictive for success in controlling myopia progression in a group of children wearing MiSight Contact Lens (CLs). METHODS: Myopic patients (n=41) fitted with MiSight CLs and followed up two years were included in this study. Bivariate analysis, a logistic regression analysis (LG) and a decision tree (DT) approach were used to screen for the factors influencing the success of the treatment. To assess the response, axial length (AL) changes were considered as main variable. Patients were classified based on a specific range of change of axial length at the end of each year of treatment as "responders" (R) (AL change <0.11mm/per year) and "non-responders" (NR) (AL change ≥0.11mm/per year). RESULTS: Of a total of forty-one Caucasian patients treated with MiSight CLs, 21 and 16 were considered responders in the first and the second year of follow-up, respectively. LG analysis showed that the only factor associated with smaller axial length growth was more time spent outdoors (p=0.0079) in the first year of treatment. The decision tree analysis showed that in the responding group spending more than 3 and 4h outdoors per week was associated with the best response in the first year and in the second year of treatment respectively. CONCLUSIONS: The LR and the DT approach of this pilot study identifies time spent outdoors as a main factor in controlling axial eye growth in children treated with MiSight CLs.
Asunto(s)
Lentes de Contacto Hidrofílicos , Miopía , Longitud Axial del Ojo , Niño , Progresión de la Enfermedad , Humanos , Miopía/diagnóstico , Miopía/terapia , Proyectos Piloto , Refracción Ocular , EspañaRESUMEN
Purpose: The purpose of this study was to measure the intraocular pressure (IOP) elevation during laser assisted in situ keratomileusis (LASIK) flap creation using the WaveLight FS200 femtosecond (FS) laser platform. Methods: We conducted an ex vivo experimental study in an animal model. The WaveLight FS200 FS laser platform was used to perform the corneal LASIK flap in freshly enucleated porcine eyes. We measured the changes in IOP from the application of the suction ring (suctioning phase) through the creation of the lamellar corneal flap (cutting phase). The IOP was recorded using a manometric technique with direct cannulation to the anterior chamber. Results: Nine freshly enucleated porcine eyes were included in the study. The mean baseline IOP before the procedure was 20.33 ± 5.9 mm Hg. The mean IOP increase over baseline IOP was 32.33 ± 11.3 mm Hg at the suctioning phase, and 38.22 ± 11.3 mm Hg at the cutting phase. The total surgical time needed to complete the procedure was 29.5 ± 4.4 seconds. Conclusions: The WaveLight FS200 FS laser platform produces a low to moderate increase in IOP during LASIK flap creation. Translational Relevance: The WaveLight FS200 is a safe FS laser platform because it induces a low to moderate IOP increase during LASIK flap creation.
Asunto(s)
Queratomileusis por Láser In Situ , Animales , Presión Intraocular , Rayos Láser , Colgajos Quirúrgicos , Porcinos , Tonometría OcularRESUMEN
Purpose: To measure the in vitro flow properties of the PRESERFLO implant for comparison with the theoretical resistance to flow. Methods: The PRESERFLO was designed to control the flow of aqueous humor according to the Hagen-Poiseuille (HP) equation. Scanning electron microscopy (SEM) was performed to analyze the ultrastructure, and flow measurements were carried out using a gravity-flow setup. Results: SEM images of the PRESERFLO showed luminal diameters of 67.73 × 65.95 µm and 63.66 × 70.54 µm. The total diameter was 337.2 µm, and the wall was 154 µm wide. The theoretical calculation of the resistance to flow (R) for an aqueous humor (AH) viscosity of 0.7185 centipoises (cP) was 1.3 mm Hg/(µL/min). Hence, assuming a constant AH flow of 2 µL/min, the pressure differential across the device (ΔP) was estimated to be 2.6 mm Hg. The gravity-flow experiment allowed us to measure the experimental resistance to flow, which was RE = 1.301 mm Hg/(µL/min), in agreement with the theoretical resistance to flow R given by the HP equation. Conclusions: The experimental and theoretical flow testing showed that the pressure drop across this device would not be large enough to avoid hypotony unless the resistance to outflow of the sub-Tenon space was sufficient to control the intraocular pressure in the early postoperative period. Translational Relevance: The fluid properties of glaucoma subconjunctival drainage devices determine their specific bleb-forming capacity and ability to avoid hypotony and therefore their safety and efficacy profile.
Asunto(s)
Implantes de Drenaje de Glaucoma , Humor Acuoso , Presión Intraocular , Tonometría OcularRESUMEN
PURPOSE: To investigate whether cessation of MiSight contact lens (CLs) wear for myopia control produces rebound effect. MATERIAL AND METHODS: This study recruited participants who had just completed the MASS Study, a two-year randomized clinical trial designed to assess the efficacy of MiSight® CLs versus distance single vision (SV) spectacles in myopic children. To assess the rebound effect, axial length progression was taken into account in those children that continued one more year of follow-up. At this visit, children were divided into three groups: MiSight-C group, in which children from the original study group continued MiSight CLs wear for the duration of the study; MiSight-D group, in which children from the original study group discontinued MiSight CLs wear in the last year; and SV-C group, in which children from the original control group continued wearing single-vision spectacles for the duration of the study. The last group was considered as the control group. RESULTS: Of the 74 children who completed the MASS study, 55 children completed the 1-year follow-up and were included in the analysis. Thirteen children were included in the MiSight-C group, 18 in the MiSight-D group, and 24 in the Single Vision-C group. Axial length and myopia progression in the last year were 0.15± 0.11 mm, 0.22± 0.11 mm, 0.21± 0.10 mm and -0.37±0.44D, -0.46±0.39D and -0.55±0.45D for the three groups, respectively. No significant differences in axial elongation and myopia progression were found among the three groups of participants. CONCLUSIONS: Over a one-year period, neither myopia progression nor eye growth was faster for the subjects who discontinued MiSight contact lens wear compared to those who continued to wear MiSight contact lenses or those who continued to wear single-vision spectacles, indicating no rebound effect with MiSight contact lenses for 2 years.ClinicalTrials.gov Identifier: NCT01917110.
Asunto(s)
Lentes de Contacto , Miopía/diagnóstico , Miopía/terapia , Procedimientos de Ortoqueratología , Adolescente , Longitud Axial del Ojo/fisiopatología , Niño , Progresión de la Enfermedad , Anteojos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Miopía/fisiopatología , Estudios Prospectivos , Recurrencia , Refracción Ocular/fisiología , España , Agudeza Visual/fisiología , Privación de TratamientoRESUMEN
PURPOSE: To assess the effect of prior myopic ablations on the optical performance of a trifocal diffractive intraocular lens (IOL) and a novel extended depth of focus (EDOF) diffractive design. METHODS: The novel XACT Mono-EDOF ME4 diffractive IOL (Santen Pharmaceutical) and the trifocal diffractive FineVision IOL (PhysIOL) were analyzed standing alone and combined with a simulated myopic corneal ablation. The optical quality of the IOLs in both situations was evaluated with the PMTF optical bench (LAMBDA-X). The through-focus modulation transfer function (MTF) curves and the MTF at three different focal points (+0.50, 0.00, and -0.50 diopters [D]) were recorded. RESULTS: The through-focus MTF curves showed three differentiated peaks for the trifocal IOL and two overlapped peaks for the EDOF IOL. The presence of simulated myopic corneal ablations induces a -0.50 D shift on the overall through-focus curves and softens the multifocal properties of both lenses by decreasing the variations through focus of the MTF. For the analysis of the lenses standing alone, the highest MTF values were obtained for an object vergence of 0.00 D. For a simulated myopic corneal ablation, both IOLs showed better optical quality results at -0.50 D. CONCLUSIONS: The trifocal IOL provides better optical quality at far and near distances when analyzed alone. The EDOF IOL optical properties are more stable when a myopic ablation is introduced. Preoperative calculations of both lenses should consider that prior myopic corneal ablations induce a -0.50 D shift on their far peak quality. [J Refract Surg. 2020;36(7):435-441.].
Asunto(s)
Córnea/diagnóstico por imagen , Modelos Teóricos , Lentes Intraoculares Multifocales , Miopía/cirugía , Óptica y Fotónica , Refracción Ocular/fisiología , Humanos , Miopía/fisiopatología , Diseño de PrótesisRESUMEN
PURPOSE: The aim of the current study is to assess, using new technologies, the interaction of four monthly silicone hydrogel contact lenses on the ocular surface and the comfort over 15 days of use. METHODS: Prospective cross-over, randomized and double-masked study including four materials (lotrafilcon-B, samfilcon-A , comfilcon-A and filcom-V3). Clinical examination was performed in the following order: tear meniscus height, first break-up of the tear film, the average time of all tear film breakup incidents, bulbar redness, limbal redness (Keratograph 5M ,Oculus, Germany); central corneal thickness (Pentacam, Oculus, Germany), thermography values (FLIR A325; FLIR Systems Inc., USA), and slit-lamp evaluations, including ocular surface staining. Finally, subjective comfort was obtained from Contact Lens Dry Eye Questionnaire-8. RESULTS: The impact of contact lens wear on the ocular surface didn't show statistically significant changes over time except for corneal and conjunctival staining grades on day 15 compared to day 1 for the comfilcon A group (Pâ¯=â¯.003 and Pâ¯=â¯.01, respectively). Contact lens stability and impact on the ocular surface during contact lens wear didn't show statistically significant changes over time except in the case of the comfilcon A material with respect to the irritation item (Pâ¯=â¯.01). CONCLUSIONS: These results suggest that the impact of monthly silicone hydrogel contact lens materials on the ocular surface after and during contact lens wear, contact lens stability over time, and subjective comfort did not reveal any significant changes over 15 days of use for any of the materials.
Asunto(s)
Lentes de Contacto Hidrofílicos , Córnea/fisiopatología , Elastómeros de Silicona , Lágrimas/fisiología , Adulto , Estudios Cruzados , Método Doble Ciego , Síndromes de Ojo Seco/fisiopatología , Femenino , Humanos , Masculino , Estudios Prospectivos , Ajuste de Prótesis , Microscopía con Lámpara de Hendidura , Encuestas y Cuestionarios , Termografía , Adulto JovenRESUMEN
AIM: To estimate and compare the frequency of accommodative insufficiency (AI) within the same clinical population sample depending on the type of clinical criteria used for diagnosis. Comparing the frequency within the same population would help to minimize bias due to sampling or methodological variability. METHODS: Retrospective study of 205 medical records of symptomatic subjects free of any organic cause and symptoms persisting despite optical compensation evaluated. Based on the most commonly clinical diagnostics criteria found in the literature, four diagnostics criteria were established for AI (I, II, III and IV) based on subjective accommodative tests: monocular accommodative amplitude two or more diopters below Hofstetter's minimum value [15-(0.25×age)] (I, II, III, IV); failing monocular accommodative facility with minus lens, establishing the cut-off in 0 cycles per minute (cpm) (I) and in 6 cpm (II, III); failing binocular accommodative facility with minus lens, establishing the cut-off in 0 cpm (I) and in 3 cpm (II). RESULTS: The proportion of AI (95%CI) for criteria I, II, III and IV were 1.95% (0.04%-3.86%), 2.93% (0.31%-4.57%), 6.34% (1.90%-7.85%) and 41.95% (35.14%-48.76%) respectively, with a statistically significant difference shown between these values (χ2 =226.7, P<0.001). A pairwise multiple comparison revealed that the proportion of AI detected for criterion IV was significantly greater than the proportion for the rest of the criteria (P-adjusted<0.05 in all cases). CONCLUSION: The prevalence of cases of AI within the same clinical population varies with the clinical diagnostic criteria selected. The variation is statistically significant when considering the monocular accommodative amplitude as the only clinical diagnostic sign.