Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Radiology ; 307(1): e222087, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36445225

RESUMEN

Background Photon-counting detector (PCD) CT enables ultra-high-resolution lung imaging and may shed light on morphologic correlates of persistent symptoms after COVID-19. Purpose To compare PCD CT with energy-integrating detector (EID) CT for noninvasive assessment of post-COVID-19 lung abnormalities. Materials and Methods For this prospective study, adult participants with one or more COVID-19-related persisting symptoms (resting or exertional dyspnea, cough, fatigue) underwent same-day EID and PCD CT between April 2022 and June 2022. The 1.0-mm EID CT images and, subsequently, 1.0-, 0.4-, and 0.2-mm PCD CT images were reviewed for the presence of lung abnormalities. Subjective and objective EID and PCD CT image quality were evaluated using a five-point Likert scale (-2 to 2) and lung signal-to-noise ratios (SNRs). Results Twenty participants (mean age, 54 years ± 16 [SD]; 10 men) were included. EID CT showed post-COVID-19 lung abnormalities in 15 of 20 (75%) participants, with a median involvement of 10% of lung volume [IQR, 0%-45%] and 3.5 lobes [IQR, 0-5]. Ground-glass opacities and linear bands (10 of 20 participants [50%] for both) were the most frequent findings at EID CT. PCD CT revealed additional lung abnormalities in 10 of 20 (50%) participants, with the most common being bronchiectasis (10 of 20 [50%]). Subjective image quality was improved for 1.0-mm PCD versus 1.0-mm EID CT images (median, 1; IQR, 1-2; P < .001) and 0.4-mm versus 1.0-mm PCD CT images (median, 1; IQR, 1-1; P < .001) but not for 0.4-mm versus 0.2-mm PCD CT images (median, 0; IQR, 0-0.5; P = .26). PCD CT delivered higher lung SNR versus EID CT for 1.0-mm images (mean difference, 0.53 ± 0.96; P = .03) but lower SNR for 0.4-mm versus 1.0-mm images and 0.2-mm vs 0.4-mm images (-1.52 ± 0.68 [P < .001] and -1.15 ± 0.43 [P < .001], respectively). Conclusion Photon-counting detector CT outperformed energy-integrating detector CT in the visualization of subtle post-COVID-19 lung abnormalities and image quality. © RSNA, 2023 Supplemental material is available for this article.


Asunto(s)
COVID-19 , Fotones , Masculino , Adulto , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Fantasmas de Imagen , COVID-19/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Pulmón/diagnóstico por imagen
2.
Langmuir ; 38(26): 8094-8103, 2022 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-35732057

RESUMEN

The kinetic rehydration of thin di-block copolymer poly(diethylene glycol monomethyl ether methacrylate)-block-poly(poly(ethylene glycol) methyl ether methacrylate) (PO2-b-PO300) films containing two thermoresponsive components is probed by in situ neutron reflectivity (NR) with different thermal stimuli in the D2O vapor atmosphere. The transition temperatures (TTs) of PO2 and PO300 blocks are 25 and 60 °C, respectively. After the one-step stimulus (rapid decrease in temperature from 60 to 20 °C), the film directly switches from a collapsed to a fully swollen state. The rehydration process is divided into four steps: (a) D2O condensation, (b) D2O absorption, (c) D2O evaporation, and (d) film reswelling. However, the film presents a different rehydration behavior when the thermal stimulus is separated into two smaller steps (first decrease from 60 to 40 °C and then to 20 °C). The film first switches from a collapsed to a semiswollen state caused by the rehydrated PO300 blocks after the first step of thermal stimulus (60 to 40 °C) and then to a swollen state induced by the rehydrated PO2 blocks after the second step (40 to 20 °C). Thus, the kinetic responses are distinct from that after the one-step thermal stimulus. Both the time and extent of condensation as well as evaporation processes are significantly reduced in these two smaller steps. However, the final states of the rehydrated PO2-b-PO300 films are basically identical irrespective of the applied thermal stimulus. Thus, the final state of thermoresponsive di-block copolymer films is not affected by the external thermal stimuli, which is beneficial for the design and preparation of sensors or switches based on thermoresponsive polymer films.

3.
Mod Rheumatol ; 32(2): 365-372, 2022 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-34910198

RESUMEN

OBJECTIVES: Interstitial lung disease (ILD) associated with the antimelanoma differentiation-associated protein 5 (anti-MDA5) antibody is a rapidly progressive disease that requires timely, aggressive treatment. However, prompt diagnosis is difficult due to the longer time required for antibody detection. This study described the computed tomography (CT) findings of anti-MDA5 antibody-positive ILD (anti-MDA5-ILD). METHODS: CT findings of 20 patients (7 men, 13 women; mean age, 53.6 ± 13.5 years) with anti-MDA5-ILD were retrospectively reviewed. All patients had clinical diagnoses of dermatomyositis, and 14 patients presented with amyopathic findings. RESULTS: Bilateral ground-glass attenuation, air-space consolidation, and reticular shadows were observed in 20 (100%), 15 (75%), and 3 (15%) patients, respectively. The spread of air-space consolidation was 6.0 ± 5.6% (mean ± standard deviation). Univariate analysis revealed that high Krebs von den Lungen-6, high spread of consolidation, low partial pressure of oxygen, and low forced vital capacity were significant predictors for poor survival. The final radiological diagnoses were nonspecific interstitial pneumonia and organising pneumonia (OP) in 2 (10%) and 16 (80%) patients, respectively. Further, 30% of OP patients showed fibrosis. CONCLUSION: The characteristic CT findings of patients with anti-MDA5-ILD were ground-glass attenuation, air-space consolidation, and less reticulation. These CT findings were compatible with those of OP.


Asunto(s)
Dermatomiositis , Enfermedades Pulmonares Intersticiales , Adulto , Anciano , Autoanticuerpos , Dermatomiositis/complicaciones , Femenino , Humanos , Helicasa Inducida por Interferón IFIH1 , Enfermedades Pulmonares Intersticiales/complicaciones , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
4.
Eur J Nucl Med Mol Imaging ; 48(5): 1522-1537, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33619599

RESUMEN

BACKGROUND: MR is an important imaging modality for evaluating musculoskeletal malignancies owing to its high soft tissue contrast and its ability to acquire multiparametric information. PET provides quantitative molecular and physiologic information and is a critical tool in the diagnosis and staging of several malignancies. PET/MR, which can take advantage of its constituent modalities, is uniquely suited for evaluating skeletal metastases. We reviewed the current evidence of PET/MR in assessing for skeletal metastases and provided recommendations for its use. METHODS: We searched for the peer reviewed literature related to the usage of PET/MR in the settings of osseous metastases. In addition, expert opinions, practices, and protocols of major research institutions performing research on PET/MR of skeletal metastases were considered. RESULTS: Peer-reviewed published literature was included. Nuclear medicine and radiology experts, including those from 13 major PET/MR centers, shared the gained expertise on PET/MR use for evaluating skeletal metastases and contributed to a consensus expert opinion statement. [18F]-FDG and non [18F]-FDG PET/MR may provide key advantages over PET/CT in the evaluation for osseous metastases in several primary malignancies. CONCLUSION: PET/MR should be considered for staging of malignancies where there is a high likelihood of osseous metastatic disease based on the characteristics of the primary malignancy, hight clinical suspicious and in case, where the presence of osseous metastases will have an impact on patient management. Appropriate choice of tumor-specific radiopharmaceuticals, as well as stringent adherence to PET and MR protocols, should be employed.


Asunto(s)
Testimonio de Experto , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18 , Humanos , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Radiofármacos
5.
Langmuir ; 37(22): 6819-6829, 2021 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-34043364

RESUMEN

The hydration and thermal response kinetics of the cross-linked thermoresponsive copolymer poly((diethylene glycol monomethyl ether methacrylate)-co-poly(ethylene glycol) methyl ether methacrylate), abbreviated as P(MEO2MA-co-OEGMA300), thin film on a hydrophobic polyacrylonitrile (PAN) substrate coating, which resembles a synthetic fabric, is probed by in situ neutron reflectivity (NR). The PAN and monomer (MEO2MA and OEGMA300) solutions are sequentially spin-coated onto a silicon (Si) substrate. Afterward, plasma treatment is applied to realize the cross-linking of PAN and monomers. The as-prepared cross-linked P(MEO2MA-co-OEGMA300) film on the hydrophobic PAN substrate coating presents a two-layer structure: a substrate-near layer, which is a mixture of PAN and P(MEO2MA-co-OEGMA300), and a main layer, which is composed of pure hydrophilic P(MEO2MA-co-OEGMA300). During hydration in D2O vapor atmosphere, the hydrophobic PAN component prevents the formation of D2O enrichment in the substrate-near layer. However, an additional vapor-near layer is observed on top of the main layer, which is enriched with D2O. The hydration process is constrained by the cross-linking points in the film, inducing the relaxation time to be longer than that in a spin-coated P(MEO2MA-co-OEGMA300) film. Because the as-prepared cross-linked film presents a transition temperature (TT) at 38 °C, the hydrated film switches to the collapsed state when the temperature is increased from 23 to 50 °C. The response to a thermal stimulus is also slower due to the existence of the internal cross-linking points as compared to the spin-coated film. Interestingly, no reswelling is observed at the end of the thermal stimulus, which can be also attributed to the presence of internal cross-linking points.

6.
Radiology ; 297(1): 6-14, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32840473

RESUMEN

Artificial intelligence (AI) is becoming increasingly present in radiology and health care. This expansion is driven by the principal AI strengths: automation, accuracy, and objectivity. However, as radiology AI matures to become fully integrated into the daily radiology routine, it needs to go beyond replicating static models, toward discovering new knowledge from the data and environments around it. Continuous learning AI presents the next substantial step in this direction and brings a new set of opportunities and challenges. Herein, the authors discuss the main concepts and requirements for implementing continuous AI in radiology and illustrate them with examples from emerging applications.


Asunto(s)
Inteligencia Artificial , Radiología/tendencias , Macrodatos , Humanos
7.
Langmuir ; 36(22): 6228-6237, 2020 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-32388986

RESUMEN

The impact of thermal history on the kinetic response of thin thermoresponsive diblock copolymer poly(diethylene glycol monomethyl ether methacrylate)-block-poly(poly(ethylene glycol) methyl ether methacrylate), abbreviated as PMEO2MA-b-POEGMA300, films is investigated by in situ neutron reflectivity. The PMEO2MA and POEGMA300 blocks are both thermoresponsive polymers with a lower critical solution temperature. Their transition temperatures (TTs) are around 25 °C (TT1, PMEO2MA) and 60 °C (TT2, POEGMA300). Thus, by applying different temperature protocols (20 to 60 or 20 to 40 to 60 °C), the PMEO2MA-b-POEGMA300 thin films experience different thermal histories: the first protocol directly switches from a swollen to a collapsed state, whereas the second one switches first from a swollen to a semicollapsed and finally to a collapsed state. Although the applied thermal histories differ, the response and final state of the collapsed films are very close to each other. After the thermal stimulus, both films present a complicated response composed of an initial shrinkage, followed by a rearrangement. Interestingly, a subsequent reswelling of the collapsed film is only observed in the case of having applied a thermal stimulus of 20 to 40 °C. The normalized film thickness and the D2O amount of each layer in the PMEO2MA-b-POEGMA300 films are consistent at the end of the two different thermal stimuli. Hence, it can be concluded that the thermal history does not influence the final state of the PMEO2MA-b-POEGMA300 films upon heating. Based on this property, these thin films are especially suitable for the temperature switches on the nanoscale, which may experience different thermal histories.

8.
Eur Radiol ; 30(8): 4295-4305, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32242275

RESUMEN

OBJECTIVES: Previous studies have shown that split-bolus protocols in virtual non-contrast (VNC) reconstructions of dual-energy computed tomography (DE-CT) significantly decrease radiation dose in patients with urinary stone disease. To evaluate the impact on kidney stone detection rate of stone composition, size, tube voltage, and iodine concentration for VNC reconstructions of DE-CT. METHODS: In this prospective study, 16 kidney stones of different sizes (1.2-4.5 mm) and compositions (struvite, cystine, whewellite, brushite) were placed within a kidney phantom. Seventy-two scans with nine different iodine contrast agents/saline solutions with increasing attenuation (0-1400 HU) and different kilovoltage settings (70 kV/150 kV; 80 kV/150 kV; 90 kV/150 kV; 100 kV/150 kV) were performed. Two experienced radiologists independently rated the images for the presence and absence of stones. Multivariate classification tree analysis and descriptive statistics were used to evaluate the diagnostic performance. RESULTS: Classification tree analysis revealed a higher detection rate of renal calculi > 2 mm in size compared with that of renal calculi < 2 mm (84.7%; 12.7%; p < 0.001). For stones with a diameter > 2 mm, the best results were found at 70 kV/Sn 150 kV and 80 kV/Sn 150 kV in scans with contrast media attenuation of 600 HU or less, with sensitivity of 99.6% and 96.0%, respectively. A higher luminal attenuation (> 600 HU) resulted in a significantly decreased detection rate (91.8%, 0-600 HU; 70.7%, 900-1400 HU; p < 0.001). In our study setup, the detection rates were best for cystine stones. CONCLUSION: Scan protocols in DE-CT with lower tube current and lower contrast medium attenuation show excellent results in VNC for stones larger than 2 mm but have limitations for small stones. KEY POINTS: • The detection rate of virtual non-contrast reconstructions is highly dependent on the surrounding contrast medium attenuation at the renal pelvis and should be kept as low as possible, as at an attenuation higher than 600 HU the VNC reconstructions are susceptible to masking ureteral stones. • Protocols with lower tube voltages (70 kV/Sn 150 kV and 80 kV/Sn 150 kV) improve the detection rate of kidney stones in VNC reconstructions. • The visibility of renal stones in virtual non-contrast of dual-energy CT is highly associated with the size, and results in a significantly lower detection rate in stones below 2 mm.


Asunto(s)
Medios de Contraste , Procesamiento de Imagen Asistido por Computador/métodos , Cálculos Renales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Oxalato de Calcio , Fosfatos de Calcio , Cistina , Humanos , Yodo , Fantasmas de Imagen , Estudios Prospectivos , Dosis de Radiación , Estruvita , Cálculos Urinarios
10.
Skeletal Radiol ; 47(7): 963-971, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29372277

RESUMEN

OBJECTIVE: To evaluate the feasibility of hand MRI in age assessment in adolescents using the Greulich-Pyle (GP) atlas criteria. MATERIALS AND METHODS: Two radiologists, who were blinded to the study subjects' chronologic ages, semi-objectively evaluated 1.5-T MRIs of the left hands of ten patients (13.5 ± 2.6 years) who had left-hand radiographs and 50 healthy volunteers (15 ± 2 years). RESULTS: A coronal T1-weighted, volumetric, interpolated, breath-hold examination with water excitation (T1 VIBE-3D-WE) achieved the best image quality. The correlation between estimated patients' ages on radiographs and MRI was high. The average estimated age difference between the MRIs and radiographs was -0.05 years for reader 1 and -0.175 years for reader 2. The interclass coefficients (ICCs) showed high interobserver agreement (radiographs: ICC = 0.95, MRI: ICC = 0.97). The ICC, calculated separately for the male and female volunteers' estimated ages by MRI, also showed a high agreement between the two readers (male: ICC = 0.97, female: ICC = 0.95). Reader 1 estimated 94% of volunteers within 2 standard deviations (SD) and 62% within 1 SD. The results for reader 2 were 92% and 54%, respectively. Thirty-nine percent of girls and 27% of boys were estimated to be older using 1 SD. CONCLUSION: MRI of the left hand is a feasible alternative to hand radiographs for skeletal age estimation in adolescents using the GP criteria with 2 SD. Using 1 SD, the age of healthy volunteers tended to be estimated as higher than the chronologic age. Future studies should evaluate the results in a larger number of participants.


Asunto(s)
Determinación de la Edad por el Esqueleto/métodos , Atlas como Asunto , Mano/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Femenino , Humanos , Masculino
12.
J Magn Reson Imaging ; 45(3): 646-659, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27862590

RESUMEN

MRI has emerged as the most comprehensive noninvasive diagnostic tool for focal liver lesions and diffuse hepatobiliary disorders. The introduction of hepatobiliary contrast agents, most notably gadoxetic acid (GA), has expanded the role of MRI, particularly in the functional imaging of chronic liver diseases, such as nonalcoholic fatty liver disease (NAFLD). GA-enhanced MRI (GA-MRI) may help to distinguish between the two subgroups of NAFLD, simple steatosis and nonalcoholic steatohepatitis. Furthermore, GA-MRI can be used to stage fibrosis and cirrhosis, predict liver transplant graft survival, and preoperatively estimate the risk of liver failure should major resection be undertaken. The amount of GA uptake can be estimated, using static images, by the relative liver enhancement, hepatic uptake index, and relaxometry of T1-mapping during the hepatobiliary phase. On the contrary, the hepatic extraction fraction and liver perfusion can be measured on dynamic imaging. Importantly, there is currently no clear consensus as to which of these MR-derived parameters is the most suitable for assessing liver dysfunction. This review article aims to describe the current role of GA-enhanced MRI in quantifying liver function, primarily in diffuse hepatobiliary disorders. LEVEL OF EVIDENCE: 3 J. Magn. Reson. Imaging 2017;45:646-659.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Gadolinio DTPA/farmacocinética , Hepatopatías/diagnóstico por imagen , Hepatopatías/metabolismo , Hígado/metabolismo , Modelos Biológicos , Simulación por Computador , Medios de Contraste/farmacocinética , Medicina Basada en la Evidencia , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Hígado/diagnóstico por imagen , Hígado/patología , Hepatopatías/patología , Pruebas de Función Hepática , Tasa de Depuración Metabólica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribución Tisular
14.
Indian J Plast Surg ; 50(1): 56-63, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28615811

RESUMEN

OBJECTIVES: In addition to its use as a volume filler, fat grafting may have a potential role in wound healing based on the concentration of growth factors in the lipoaspirate. In this study, we compare the quantitative and qualitative concentration of the various growth factors and adipokines using the Shippert or the Coleman techniques to prepare the lipoaspirate. METHODS: We measured leptin, adiponectin and the growth factors, i.e., acidic fibroblast growth factor (aFGF), basic FGF (bFGF), keratinocyte growth factor (KGF), bone morphogenetic protein-2 (BMP-2) and vascular endothelial growth factor (VEGF) by ELISA in solid and liquid fractions obtained with both techniques in human fat obtained with Coleman technique and Shippert technique. RESULTS: All of these peptides, except BMP-2, were detected in relevant quantities in the solid fraction. The Coleman but not the Shippert technique resulted in statistically higher adiponectin concentrations in the solid tissue fraction. The other four growth factors occurred in significantly higher concentrations in the solid fractions compared to the liquid fractions, independent of the processing technique. CONCLUSION: In summary, we demonstrated that KGF, aFGF, bFGF and VEGF, as well as leptin and adiponectin, are contained in fat suspensions obtained by liposuction and in the supernatant. Only the concentration of adiponectin was in the range reported to contribute to wound healing.

15.
Radiology ; 279(1): 226-38, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26465058

RESUMEN

During the past decade, with its breakthroughs in systems biology, precision medicine (PM) has emerged as a novel health-care paradigm. Challenging reductionism and broad-based approaches in medicine, PM is an approach for disease treatment and prevention that takes into account individual variability in genes, environment, and lifestyle. It involves integrating information from multiple sources in a holistic manner to achieve a definitive diagnosis, focused treatment, and adequate response assessment. Biomedical imaging and imaging-guided interventions, which provide multiparametric morphologic and functional information and enable focused, minimally invasive treatments, are key elements in the infrastructure needed for PM. The emerging discipline of radiogenomics, which links genotypic information to phenotypic disease manifestations at imaging, should also greatly contribute to patient-tailored care. Because of the growing volume and complexity of imaging data, decision-support algorithms will be required to help physicians apply the most essential patient data for optimal management. These innovations will challenge traditional concepts of health care and business models. Reimbursement policies and quality assurance measures will have to be reconsidered and adapted. In their 10th biannual symposium, which was held in August 2013, the members of the International Society for Strategic Studies in Radiology discussed the opportunities and challenges arising for the imaging community with the transition to PM. This article summarizes the discussions and central messages of the symposium.


Asunto(s)
Diagnóstico por Imagen , Medicina de Precisión , Humanos
16.
Inorg Chem ; 55(13): 6414-9, 2016 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-27295388

RESUMEN

Two dinuclear iron(II) complexes [Fe2(µ-L)2]X4*4DMF (X = BF4(-) (1·4DMF) and ClO4(-) (2·4DMF)) with a 1,3,4-thiadiazole bridging ligand have been synthesized and show a very distinct solvent-depending SCO behavior. The complexes represent new solvatomorphs of the first dinuclear iron(II) complexes with the ligand L (2,5-bis[(2-pyridylmethyl)amino]methyl-1,3,4-thiadiazole). The incorporated lattice DMF molecules directly affect the spin state of these complexes. This behavior reveals a structural insight into the role of the solvent molecules on the spin transition.

17.
Ann Plast Surg ; 77(4): 401-5, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27387468

RESUMEN

INTRODUCTION: Increased evaporative water loss (EWL) in burn patients leads to dehydration and hypothermia. Early clinical studies performed with outdated hygrometers suggested a 17 to 75 times increased EWL in burns with contradicting results for the different burn depths.Our study proposals were: (1) obtain reliable data of the EWL of all burn depths, (2) compare these results with findings from earlier studies, (3) evaluate the usefulness of the EWL in differentiating between superficial and deep partial thickness burns, (4) determine the effect of Biobrane on the EWL of superficial partial thickness burns in vivo, and (5) evaluate the effect of the sterile incision foil Opraflex on the EWL in split skin graft donor sites. METHODS: We measured the EWL of all burn depths in 28 patients under stable and recorded conditions regarding room temperature and humidity with a modern digital evaporimeter (Tewameter TM 300). For the first time in vivo, we also determined the effect of Biobrane on the EWL of burns and evaluated the EWL in split skin graft donor sites covered with Opraflex. RESULTS: The EWL in all burn depths was significantly increased (P < 0.001) compared with unburned skin. There was no significant difference (P > 0.05) in the EWL of superficial compared with deep partial thickness burns, whereas full thickness burns had a significantly lower EWL (P < 0.05) compared with superficial and deep partial thickness burns. Biobrane significantly reduced the EWL (P < 0.05) of superficial partial thickness burns. The EWL of Opraflex covered skin graft donor sites was significantly reduced compared with uncovered donor sites (P < 0.05). CONCLUSIONS: Our data suggest that the actual EWL in burns is approximately 3 times higher in full thickness burns and approximately 4 times higher in superficial and deep partial thickness burns compared with normal skin and therefore much lower than suggested previously.Because there was no significant difference in the EWL of superficial compared with deep partial thickness burns, the EWL cannot be used to differentiate between these burn depths.Biosynthetic wound dressings can significantly reduce the EWL of superficial partial thickness burns and sterile incision foil protects split skin graft donor sites from an increased EWL.


Asunto(s)
Quemaduras/fisiopatología , Pérdida Insensible de Agua/fisiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Quemaduras/diagnóstico , Quemaduras/patología , Quemaduras/terapia , Materiales Biocompatibles Revestidos/uso terapéutico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Apósitos Oclusivos , Trasplante de Piel , Índices de Gravedad del Trauma , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA