Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 42(7): 1038-1046, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31119745

RESUMEN

INTRODUCTION: We conducted this study to show the safety and efficacy of a new implantable cardiac monitor (ICM), the BioMonitor 2 (Biotronik SE & Co. KG; Berlin, Germany), and to describe the arrhythmia detection performance. METHODS: The BioMonitor 2 has an extended sensing vector and is implanted close to the heart. It can transmit up to six subcutaneous electrocardiogram strips by Home Monitoring each day. We enrolled 92 patients with a standard device indication for an ICM in a single-arm, multicenter prospective trial. Patients were followed for 3 months, and 48-h Holter recordings were used to evaluate the arrhythmia detection performance. RESULTS: One patient withdrew consent and in one patient, the implantation failed. Two study device-related serious adverse events were reported, satisfying the primary safety hypothesis. Implantations took 7.4 ± 4.4 min from skin cut to suture. At 1 week, the R-wave amplitude was 0.75 ± 0.53 mV. In the 82 patients with completed Holter recordings, all patients with arrhythmias were correctly identified. False positive detections of arrhythmia were mostly irregular rhythms wrongly detected as atrial fibrillation (episode-based positive predictive value 72.5%). Daily Home Monitoring transmission was 94.9% successful. CONCLUSION: Safety and efficacy of the new device has been demonstrated. The detected R-wave amplitudes are large, leading to a low level of inappropriate detections due to over- or undersensing.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Electrocardiografía Ambulatoria/instrumentación , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
2.
Cardiol J ; 20(4): 431-8, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23913463

RESUMEN

BACKGROUND: The aim of the study was to evaluate the efficacy and safety of small surface steroid-eluting atrial and ventricular pacing leads in comparison to non-steroid leads using remote monitoring system (Biotronik Home Monitoring®). METHODS: In this randomized multicenter prospective trial, SIELLO T steroid-eluting ventricular leads (n = 42) were compared to BPPU T non-steroid leads (n = 46) and SIELLO JT steroid-eluting atrial leads (n = 24) to BPPU JT non-steroid leads (n = 27) (Biotronik, Berlin, Germany) in pacemaker devices with remote monitoring capabilities. Lead parameters were evaluated during implantation, at 1-week and 1, 3, 6-month outpatient follow-up. Remote monitoring data were collected weekly. RESULTS: Atrial and ventricular steroid-eluting leads had stable sensing and impedance as compared to non-steroid leads at implantation and during follow-up. Patients with non-steroid atrial leads had significantly higher threshold compared to steroid leads at 1-week and at 1, 3, 6-month follow-up with a peak at 1-month (1-month 1.4 ± 0.6 vs. 0.7 ± 0.3 V at 0.4 ms, p < 0.001; 6-month 0.3 ± 0.5 vs. 0.2 ± 0.3 V at 0.4 ms, p = 0.002). Patients with non-steroid ventricular leads had significantly higher threshold compared to steroid leads at 1, 3, 6-month (6-month 1.0 ± 0.3 vs. 0.6 ± 0.2 V at 0.4 ms, p < 0.001). Remote monitoring confirmed consistent results. During the study, 3 patients died of non-lead-related death. Lead repositioning was necessary in 2 atrial, 2 ventricular steroid leads and in 1 ventricular non-steroid lead. CONCLUSIONS: Atrial and ventricular pacemaker leads with steroid showed significantly lower pacing threshold compared to non-steroid leads, confirmed by remote monitoring.


Asunto(s)
Estimulación Cardíaca Artificial , Materiales Biocompatibles Revestidos , Dexametasona/administración & dosificación , Marcapaso Artificial , Esteroides/administración & dosificación , Anciano , Anciano de 80 o más Años , Impedancia Eléctrica , Diseño de Equipo , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tecnología de Sensores Remotos , Telemedicina , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA