Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Dis Colon Rectum ; 67(7): 929-939, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38517090

RESUMEN

BACKGROUND: A complete total mesorectal excision is the criterion standard in curative rectal cancer surgery. Ensuring quality is challenging in a narrow pelvis, and obesity amplifies technical difficulties. Pelvimetry is the measurement of pelvic dimensions, but its role in gauging preoperatively the difficulty of proctectomy is largely unexplored. OBJECTIVE: To determine pelvic structural factors associated with incomplete total mesorectal excision after curative proctectomy and build a predictive model for total mesorectal excision quality. DESIGN: Retrospective cohort study. SETTING: A quaternary referral center database of patients diagnosed with rectal adenocarcinoma (2009-2017). PATIENTS: Curative-intent proctectomy for rectal adenocarcinoma. INTERVENTIONS: All radiological measurements were obtained from preoperative CT images using validated imaging processing software tools. Completeness of total mesorectal excision was obtained from histology reports. MAIN OUTCOME MEASURES: Ability of radiological pelvimetry and obesity measurements to predict total mesorectal excision quality. RESULTS: Of the 410 cases meeting inclusion criteria, 362 underwent a complete total mesorectal excision (88%). Multivariable regression identified a deeper sacral curve (per 100 mm 2 [OR: 1.14; 95% CI, 1.06-1.23; p < 0.001]) and a greater transverse distance of the pelvic outlet (per 10 mm [OR:1.41, 95% CI, 1.08-1.84; p = 0.012]) to be independently associated with incomplete total mesorectal excision. An increased area of the pelvic inlet (per 10 cm 2 [OR: 0.85; 95% CI, 0.75-0.97; p = 0.02) was associated with a higher rate of complete mesorectal excision. No difference in visceral obesity ratio and visceral obesity (ratio >0.4 vs <0.4) between BMI (<30 vs ≥30) and sex was identified. A model was built to predict mesorectal quality using the following variables: depth of sacral curve, area of pelvic inlet, and transverse distance of the pelvic outlet. LIMITATIONS: Retrospective analysis is not controlled for the choice of surgical approach. CONCLUSIONS: Pelvimetry predicts total mesorectal excision quality in rectal cancer surgery and can alert surgeons preoperatively to cases of unusual difficulty. This predictive model may contribute to treatment strategy and aid in the comparison of outcomes between traditional and novel techniques of total mesorectal excision. See Video Abstract . USO DE MEDICIONES DE PELVIMETRA Y OBESIDAD VISCERAL BASADAS EN TC PARA PREDECIR LA CALIDAD DE TME EN PACIENTES SOMETIDOS A CIRUGA DE CNCER DE RECTO: ANTECEDENTES:Una escisión mesorrectal total y completa es el estándar de oro en la cirugía curativa del cáncer de recto. Garantizar la calidad es un desafío en una pelvis estrecha y la obesidad amplifica las dificultades técnicas. La pelvimetría es la medición de las dimensiones pélvicas, pero su papel para medir la dificultad preoperatoria de la proctectomía está en gran medida inexplorado.OBJETIVO:Determinar los factores estructurales pélvicos asociados con la escisión mesorrectal total incompleta después de una proctectomía curativa y construir un modelo predictivo para la calidad de la escisión mesorrectal total.DISEÑO:Estudio de cohorte retrospectivo.ÁMBITO:Base de datos de un centro de referencia cuaternario de pacientes diagnosticados con adenocarcinoma de recto (2009-2017).PACIENTES:Proctectomía con intención curativa para adenocarcinoma de recto.INTERVENCIONES:Todas las mediciones radiológicas se obtuvieron a partir de imágenes de TC preoperatorias utilizando herramientas de software de procesamiento de imágenes validadas. La integridad de la escisión mesorrectal total se obtuvo a partir de informes histológicos.PRINCIPALES MEDIDAS DE VALORACIÓN:Capacidad de la pelvimetría radiológica y las mediciones de obesidad para predecir la calidad total de la escisión mesorrectal.RESULTADOS:De los 410 casos que cumplieron los criterios de inclusión, 362 tuvieron una escisión mesorrectal total completa (88%). Una regresión multivariable identificó una curva sacra más profunda (por 100 mm2); OR:1,14,[IC95%:1,06-1,23,p<0,001], y mayor distancia transversal de salida pélvica (por 10mm); OR:1,41, [IC 95%:1,08-1,84,p=0,012] como asociación independiente con escisión mesorrectal total incompleta. Un área aumentada de entrada pélvica (por 10 cm2); OR:0,85, [IC95%:0,75-0,97,p=0,02] se asoció con una mayor tasa de escisión mesorrectal completa. No se identificaron diferencias en la proporción de obesidad visceral y la obesidad visceral (proporción>0,4 vs.<0,4) entre el índice de masa corporal (<30 vs.>=30) o el sexo. Se construyó un modelo para predecir la calidad mesorrectal utilizando variables: profundidad de la curva sacra, área de la entrada pélvica y distancia transversal de la salida pélvica.LIMITACIONES:Análisis retrospectivo no controlado por la elección del abordaje quirúrgico.CONCLUSIONES:La pelvimetría predice la calidad de la escisión mesorrectal total en la cirugía del cáncer de recto y puede alertar a los cirujanos preoperatoriamente sobre casos de dificultad inusual. Este modelo predictivo puede contribuir a la estrategia de tratamiento y ayudar en la comparación de resultados entre técnicas tradicionales y novedosas de escisión mesorrectal total. (Traducción- Dr. Ingrid Melo).


Asunto(s)
Adenocarcinoma , Obesidad Abdominal , Pelvimetría , Proctectomía , Neoplasias del Recto , Tomografía Computarizada por Rayos X , Humanos , Neoplasias del Recto/cirugía , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/patología , Masculino , Femenino , Estudios Retrospectivos , Proctectomía/métodos , Persona de Mediana Edad , Anciano , Pelvimetría/métodos , Adenocarcinoma/cirugía , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/patología , Tomografía Computarizada por Rayos X/métodos , Obesidad Abdominal/diagnóstico por imagen , Pelvis/diagnóstico por imagen , Recto/cirugía , Recto/diagnóstico por imagen
2.
J Appl Clin Med Phys ; 25(1): e14235, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38059633

RESUMEN

PURPOSE: The purpose of this investigation was to assess the effect of visceral adipose tissue volume (VA) on reader efficacy in diagnosing and characterizing small bowel Crohn's disease using lower exposure CT enterography (CTE). Secondarily, we investigated the effect of lower exposure and VA on reader diagnostic confidence. METHODS: Prospective paired investigation of 256 CTE, 129 with Crohn's disease, were reconstructed at 100% and simulated 50% and 30% exposure. The senior author provided the disease classification for the 129 patients with Crohn's disease. Patient VA was measured, and exams were evaluated by six readers for presence or absence of Crohn's disease and phenotype using a 0-10-point scale. Logistic regression models assessed the effect of VA on sensitivity and specificity. RESULTS: The effect of VA on sensitivity was significantly reduced at 30% exposure (odds radio [OR]: 1.00) compared to 100% exposure (OR: 1.12) (p = 0.048). There was no statistically significant difference among the exposures with respect to the effect of visceral fat on specificity (p = 0.159). The study readers' probability of agreement with the senior author on disease classification was 60%, 56%, and 53% at 100%, 50%, and 30% exposure, respectively (p = 0.004). When detecting low severity Crohn's disease, readers' mean sensitivity was 83%, 75%, and 74% at 100%, 50%, and 30% exposure, respectively (p = 0.002). In low severity disease, sensitivity also tended to increase as visceral fat increased (ORs per 1000 cm3 increase in visceral fat: 1.32, 1.31, and 1.18, p = 0.010, 0.016, and 0.100, at 100%, 50%, and 30% exposure). CONCLUSIONS: While the interaction is complex, VA plays a role in detecting and characterizing small bowel Crohn's disease when exposure is altered, particularly in low severity disease.


Asunto(s)
Enfermedad de Crohn , Enfermedades Intestinales , Humanos , Enfermedad de Crohn/diagnóstico por imagen , Grasa Intraabdominal/diagnóstico por imagen , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos
3.
J Appl Clin Med Phys ; 22(2): 138-144, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33368998

RESUMEN

PURPOSE: The purpose of this study was to assess the effect of obesity and iterative reconstruction on the ability to reduce exposure by studying the accuracy for detection of low-contrast low-attenuation (LCLA) liver lesions on computed tomography (CT) using a phantom model. METHODS: A phantom with four unique LCLA liver lesions (5- to 15-mm spheres, -24 to -6 HU relative to 90-HU background) was scanned without ("thin" phantom) and with ("obese" phantom) a 5-cm thick fat-attenuation ring at 150 mAs (thin phantom) and 450 mAs (obese phantom) standard exposures and at 33% and 67% exposure reductions. Images were reconstructed using standard filtered back projection (FBP) and with iterative reconstruction (Adaptive Model-Based Iterative Reconstruction strength 3, ADMIRE). A noninferiority analysis of lesion detection was performed. RESULTS: Mean area under the curve (AUC) values for lesion detection were significantly higher for the thin phantom than for the obese phantom regardless of exposure level (P < 0.05) for both FBP and ADMIRE. At 33% exposure reduction, AUC was noninferior for both FBP and ADMIRE strength 3 (P < 0.0001). At 67% exposure reduction, AUC remained noninferior for the thin phantom (P < 0.0035), but was no longer noninferior for the obese phantom (P ≥ 0.7353). There were no statistically significant differences in AUC between FBP and ADMIRE at any exposure level for either phantom. CONCLUSIONS: Accuracy for lesion detection was not only significantly lower in the obese phantom at all relative exposures, but detection accuracy decreased sooner while reducing the exposure in the obese phantom. There was no significant difference in lesion detection between FBP and ADMIRE at equivalent exposure levels for either phantom.


Asunto(s)
Algoritmos , Neoplasias Hepáticas , Humanos , Obesidad , Fantasmas de Imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador
4.
AJR Am J Roentgenol ; 212(3): 490-496, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30620681

RESUMEN

OBJECTIVE: The purposes of this article are to describe the creation of template report formats and content for a variety of abdominal and pelvic CT and MRI examinations and discuss a review-of-systems approach to text and avoidance of pitfalls of report templates. CONCLUSION: Organ system-specific report templates for CT and MRI incorporate radiologist preferences. Disease-specific report templates are created from these reports to provide a consistent radiologist and referring physician experience across the report templates.


Asunto(s)
Imagen por Resonancia Magnética , Registros Médicos , Radiografía Abdominal , Tomografía Computarizada por Rayos X , Control de Formularios y Registros , Humanos
5.
Radiology ; 287(2): 504-514, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29401040

RESUMEN

Purpose To determine the effects of patient age and comorbidity level on life expectancy (LE) benefits associated with imaging follow-up of Bosniak IIF renal cysts and pancreatic side-branch (SB) intraductal papillary mucinous neoplasms (IPMNs). Materials and Methods A decision-analytic Markov model to evaluate LE benefits was developed. Hypothetical cohorts with varied age (60-80 years) and comorbidities (none, mild, moderate, or severe) were evaluated. For each finding, LE projections from two strategies were compared: imaging follow-up and no imaging follow-up. Under follow-up, it was assumed that cancers associated with the incidental finding were successfully treated before they spread. For patients without follow-up, mortality risks from Bosniak IIF cysts (renal cell carcinoma) and SBIPMNs (pancreatic ductal adenocarcinoma) were incorporated. Model assumptions and parameter uncertainty were evaluated in sensitivity analysis. Results In the youngest, healthiest cohorts (age, 60 years; no comorbidities), projected LE benefits from follow-up were as follows: Bosniak IIF cyst, 6.5 months (women) and 5.8 months (men); SBIPMN, 6.4 months (women) and 5.3 months (men). Follow-up of Bosniak IIF cysts in 60-year-old women with severe comorbidities yielded a LE benefit of 3.9 months; in 80-year-old women with no comorbidities, the benefit was 2.8 months, and with severe comorbidities the benefit was 1.5 months. Similar trends were observed in men and for SBIPMN. Results were sensitive to the performance of follow-up for cancer detection; malignancy risks; and stage at presentation of malignant, unfollowed Bosniak IIF cysts. Conclusion With progression of age and comorbidity level, follow-up of low-risk incidental findings yields increasingly limited benefits for patients. © RSNA, 2018 Online supplemental material is available for this article.


Asunto(s)
Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma de Células Renales/diagnóstico por imagen , Hallazgos Incidentales , Enfermedades Renales Quísticas/diagnóstico por imagen , Neoplasias Renales/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Factores de Edad , Anciano , Carcinoma Ductal Pancreático/mortalidad , Carcinoma Ductal Pancreático/patología , Carcinoma de Células Renales/mortalidad , Carcinoma de Células Renales/patología , Comorbilidad , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Enfermedades Renales Quísticas/mortalidad , Enfermedades Renales Quísticas/patología , Neoplasias Renales/mortalidad , Neoplasias Renales/patología , Esperanza de Vida , Masculino , Cadenas de Markov , Persona de Mediana Edad , Neoplasias Pancreáticas/mortalidad , Neoplasias Pancreáticas/patología , Sensibilidad y Especificidad
6.
AJR Am J Roentgenol ; 210(3): 593-600, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29231758

RESUMEN

OBJECTIVE: The objective of this study was to compare reader accuracy detecting lesions near hardware in a CT phantom model at different radiation exposures using an advanced metal artifact reduction (MAR) algorithm and standard filtered back projection (FBP) techniques and to determine if radiation exposure could be decreased using MAR without compromising lesion detectability. MATERIALS AND METHODS: A CT phantom manufactured with spherical lesions of various sizes (10-20 mm) and attenuations (20-50 HU) embedded around cobalt-chromium spheres attached to titanium rods, simulating an arthroplasty, was scanned on a single CT scanner (FLASH, Siemens Healthcare) at 140 kVp and 0.6-mm collimation using clinical-dose (300 Quality Reference mAs [Siemens Healthcare]), low-dose (150 Quality Reference mAs), and high-dose (600 Quality Reference mAs) protocols. Images reconstructed with iterative MAR, advanced modeled iterative reconstruction (ADMIRE), and FBP with identical parameters were anonymized and independently reviewed by three radiologists. Accuracies for detecting lesions, measured as AUC, sensitivity, and specificity, were compared. RESULTS: Accuracy using MAR was significantly higher than that using FBP at all exposures (p values ranged from < 0.001 to 0.021). Sensitivity was also higher for MAR than for FBP at all exposures. Specificity was very high for both reconstruction techniques at all exposures with no significant differences. Accuracy of low-dose MAR was higher than and not inferior to standard-dose and high-dose FBP. MAR was significantly more sensitive than FBP in detecting smaller lesions (p = 0.021) and lesions near high streak artifact (p < 0.001). CONCLUSION: MAR improves reader accuracy to detect lesions near hardware and allows significant reductions in radiation exposure without compromising accuracy compared with FBP in a CT phantom model.


Asunto(s)
Artefactos , Metales , Prótesis e Implantes , Dosis de Radiación , Protección Radiológica/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Humanos , Variaciones Dependientes del Observador , Fantasmas de Imagen
7.
AJR Am J Roentgenol ; 209(2): 339-349, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28570099

RESUMEN

OBJECTIVE: The objective of this study was to measure the accuracy and interobserver agreement of the Prostate Imaging Reporting and Data System, version 2 (PI-RADSv2), for the characterization of prostate lesions on multiparametric MRI. MATERIALS AND METHODS: This retrospective study included 170 men examined at a single institution between August 2014 and February 2015 on a 3-T MRI scanner. Study patients were found to have lesions concerning for prostate cancer that were targeted for MRI/transrectal ultrasound fusion biopsy. Two experienced readers independently assigned a PI-RADSv2 assessment category to the dominant lesion in each patient. The AUC was calculated to determine reader accuracy for the detection of clinically significant prostate cancer (Gleason score ≥ 3 + 4). The Cohen kappa statistic was used to quantify interobserver agreement. RESULTS: The prevalence of clinically significant prostate cancer was 0.36 (61/170 patients). The AUCs for readers 1 and 2 were 0.871 and 0.882, respectively. The AUCs were greater for peripheral zone lesions than for transition zone lesions. When a PI-RADSv2 assessment category ≥ 3 was considered positive, the agreement between readers was good overall (κ = 0.63) and was fair for transition zone lesions (κ = 0.53). When a PI-RADSv2 assessment category ≥ 4 was considered positive, the agreement was excellent overall (κ = 0.91) and was excellent for both peripheral zone lesions (κ = 0.91) and transition zone lesions (κ = 0.87). CONCLUSION: Two experienced readers were able to accurately identify patients with clinically significant prostate cancer using PI-RADSv2 with good interobserver agreement overall.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Biopsia/métodos , Humanos , Masculino , Clasificación del Tumor , Variaciones Dependientes del Observador , Prevalencia , Neoplasias de la Próstata/epidemiología , Estudios Retrospectivos , Sensibilidad y Especificidad
8.
Radiology ; 280(2): 475-82, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26937709

RESUMEN

Purpose To assess image noise, contrast-to-noise ratio (CNR) and detectability of low-contrast, low-attenuation liver lesions in a semianthropomorphic phantom by using either a discrete circuit (DC) detector and filtered back projection (FBP) or an integrated circuit (IC) detector and iterative reconstruction (IR) with changes in radiation exposure and phantom size. Materials and Methods An anthropomorphic phantom without or with a 5-cm-thick fat-mimicking ring (widths, 30 and 40 cm) containing liver inserts with four spherical lesions was scanned with five exposure settings on each of two computed tomography scanners, one equipped with a DC detector and the other with an IC detector. Images from the DC and IC detector scanners were reconstructed with FBP and IR, respectively. Image noise and lesion CNR were measured. Four radiologists evaluated lesion presence on a five-point diagnostic confidence scale. Data analyses included receiver operating characteristic (ROC) curve analysis and noninferiority analysis. Results The combination of IC and IR significantly reduced image noise (P < .001) (with the greatest reduction in the 40-cm phantom and at lower exposures) and improved lesion CNR (P < .001). There was no significant difference in area under the ROC curve between detector-reconstruction combinations at fixed exposure for either phantom. Reader accuracy with IC-IR was noninferior at 50% (100 mAs [effective]) and 25% (300 mAs [effective]) exposure reduction for the 30- and 40-cm phantoms, respectively (adjusted P < .001 and .04 respectively). IC-IR improved readers' confidence in the presence of a lesion (P = .029) independent of phantom size or exposure level. Conclusion IC-IR improved objective image quality and lesion detection confidence but did not result in superior diagnostic accuracy when compared with DC-FBP. Moderate exposure reductions maintained comparable diagnostic accuracy for both detector-reconstruction combinations. Lesion detection in the 40-cm phantom was inferior at smaller exposure reduction than in the 30-cm phantom. (©) RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Artefactos , Hígado/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Fantasmas de Imagen , Exposición a la Radiación/estadística & datos numéricos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Humanos , Tomografía Computarizada Multidetector/estadística & datos numéricos , Dosis de Radiación , Relación Señal-Ruido
9.
Radiology ; 280(2): 436-45, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27077382

RESUMEN

Purpose To compare the diagnostic accuracy and image quality of computed tomographic (CT) enterographic images obtained at half dose and reconstructed with filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) with those of full-dose CT enterographic images reconstructed with FBP for active inflammatory terminal or neoterminal ileal Crohn disease. Materials and Methods This retrospective study was compliant with HIPAA and approved by the institutional review board. The requirement to obtain informed consent was waived. Ninety subjects (45 with active terminal ileal Crohn disease and 45 without Crohn disease) underwent CT enterography with a dual-source CT unit. The reference standard for confirmation of active Crohn disease was active terminal ileal Crohn disease based on ileocolonoscopy or established Crohn disease and imaging features of active terminal ileal Crohn disease. Data from both tubes were reconstructed with FBP (100% exposure); data from the primary tube (50% exposure) were reconstructed with FBP and SAFIRE strengths 3 and 4, yielding four datasets per CT enterographic examination. The mean volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) at full dose were 13.1 mGy (median, 7.36 mGy) and 15.9 mGy (median, 13.06 mGy), respectively, and those at half dose were 6.55 mGy (median, 3.68 mGy) and 7.95 mGy (median, 6.5 mGy). Images were subjectively evaluated by eight radiologists for quality and diagnostic confidence for Crohn disease. Areas under the receiver operating characteristic curves (AUCs) were estimated, and the multireader, multicase analysis of variance method was used to compare reconstruction methods on the basis of a noninferiority margin of 0.05. Results The mean AUCs with half-dose scans (FBP, 0.908; SAFIRE 3, 0.935; SAFIRE 4, 0.924) were noninferior to the mean AUC with full-dose FBP scans (0.908; P < .003). The proportion of images with inferior quality was significantly higher with all half-dose reconstructions than with full-dose FBP (mean proportion: 0.117 for half-dose FBP, 0.054 for half-dose SAFIRE 3, 0.054 for half-dose SAFIRE 4, and 0.017 for full-dose FBP; P < .001). Conclusion The diagnostic accuracy of half-dose CT enterography with FBP and SAFIRE is statistically noninferior to that of full-dose CT enterography for active inflammatory terminal ileal Crohn disease, despite an inferior subjective image quality. (©) RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Ileítis/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Enfermedad de Crohn/complicaciones , Femenino , Tracto Gastrointestinal/diagnóstico por imagen , Humanos , Ileítis/complicaciones , Íleon/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
10.
AJR Am J Roentgenol ; 207(2): 378-85, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27186794

RESUMEN

OBJECTIVE: The purpose of this study was to compare iterative metal artifact reduction (iMAR), a new single-energy metal artifact reduction technique, with filtered back projection (FBP) in terms of attenuation values, qualitative image quality, and streak artifacts near shoulder and hip arthroplasties and observer ability with these techniques to detect pathologic lesions near an arthroplasty in a phantom model. MATERIALS AND METHODS: Preoperative and postoperative CT scans of 40 shoulder and 21 hip arthroplasties were reviewed. All postoperative scans were obtained using the same technique (140 kVp, 300 quality reference mAs, 128 × 0.6 mm detector collimation) on one of three CT scanners and reconstructed with FBP and iMAR. The attenuation differences in bones and soft tissues between preoperative and postoperative scans at the same location were compared; image quality and streak artifact for both reconstructions were qualitatively graded by two blinded readers. Observer ability and confidence to detect lesions near an arthroplasty in a phantom model were graded. RESULTS: For both readers, iMAR had more accurate attenuation values (p < 0.001), qualitatively better image quality (p < 0.001), and less streak artifact (p < 0.001) in all locations near arthroplasties compared with FBP. Both readers detected more lesions (p ≤ 0.04) with higher confidence (p ≤ 0.01) with iMAR than with FBP in the phantom model. CONCLUSION: The iMAR technique provided more accurate attenuation values, better image quality, and less streak artifact near hip and shoulder arthroplasties than FBP; iMAR also increased observer ability and confidence to detect pathologic lesions near arthroplasties in a phantom model.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastía de Reemplazo de Hombro , Prótesis de Cadera , Prótesis de Hombro , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos
11.
Radiographics ; 41(3): E92-E93, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33939549
12.
Radiographics ; 36(4): 1038-54, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27257766

RESUMEN

The kidneys and perinephric tissues can be affected by a variety of hematologic disorders, which usually occur in the setting of multisystem involvement. In many of these disorders, imaging is used to evaluate the extent of disease, guide biopsy, and/or monitor disease activity and patient response to therapy. Lymphoma, leukemia, and multiple myeloma commonly manifest as multiple parenchymal or perinephric lesions. Erdheim-Chester disease and Rosai-Dorfman disease, rare forms of multisystemic histiocytosis, are often identified as perinephric and periureteral masses. Renal abnormalities depicted at imaging in patients with sickle cell disease include renal enlargement, papillary necrosis, and renal medullary carcinoma. Sickle cell disease, along with other causes of intravascular hemolysis, can also lead to hemosiderosis of the renal cortex. Thrombosis of renal veins is sometimes seen in patients with coagulation disorders but more often occurs in association with certain malignancies and nephrotic syndrome. Immunoglobulin G4-related sclerosing disease is another multisystem process that often produces focal renal lesions, seen along with involvement of more characteristic organs such as the pancreas. Perinephric lesions with calcifications should raise the possibility of secondary amyloidosis, especially in patients with a history of lymphoma and multiple myeloma. Although the imaging patterns of renal and perinephric involvement are usually not specific for a single entity, and the same entity can manifest with different or overlapping patterns, familiarity with these patterns and key clinical and histopathologic features may help to narrow the differential diagnosis and determine the next step of care. (©)RSNA, 2016.


Asunto(s)
Enfermedades Hematológicas/diagnóstico por imagen , Enfermedades Renales/diagnóstico por imagen , Circulación Renal , Diagnóstico Diferencial , Humanos
13.
AJR Am J Roentgenol ; 205(3): 592-8, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26295647

RESUMEN

OBJECTIVE: The purposes of this study were to determine the differences in estimated volumetric CT dose index (CTDIvol) obtained from the topogram before abdominal and pelvic MDCT in adult and pediatric patients using a scan type-based algorithm for selecting kilovoltage (CARE kV) and a fixed and a weight-based Quality Reference mAs for selecting tube (gmAs) current-exposure time product, in comparison with standard protocols, and to determine the bias and variability of estimated CTDIvol vis-à-vis actual CTDIvol using the standard protocols. MATERIALS AND METHODS: During a 14-month period, 312 adult and pediatric patients referred for abdominal and pelvic MDCT were included in the study. For all patients, the estimated CTDIvol based on the topogram was recorded: protocol A, CARE kV on and 210 gmAs; protocol B, CARE kV on and 1 gmAs times patient weight (in pounds); and protocol C (standard protocol), CARE kV off, 120 kVp, and 1 gmAs times patient weight (in pounds). For the pediatric patients, estimated CTDIvol for the standard protocol D was calculated with 120 kVp and 150 gmAs. All patients were scanned with the standard protocols, and the actual CTDIvol was recorded. Linear regression models compared the CTDIvol of the three protocols in adults and the fourth for children. The estimated and actual CTDIvol were compared using a t test. RESULTS: Protocol B yielded the lowest estimated CTDIvol (mean, 13.2 mGy for adults and 3.5 mGy for pediatric patients). The estimated CTDIvol overestimated the actual CTDIvol by, on average, 1.07 mGy for adults and 0.3 mGy for children. CONCLUSION: CARE kV appears to reduce estimated CTDIvol vis-à-vis standard protocols only when a weight-based gmAs is used. Prescan estimated CTDIvol calculations appear to generally overestimate actual CTDIvol.


Asunto(s)
Tomografía Computarizada Multidetector/instrumentación , Dosis de Radiación , Adolescente , Adulto , Algoritmos , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Radiografía Abdominal
14.
Radiology ; 272(1): 154-63, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24620913

RESUMEN

PURPOSE: To measure the effect of reduced radiation exposure on low-contrast low-attenuation liver lesion detection in an anthropomorphic abdominal phantom by using filtered back projection (FBP) and sinogram-affirmed iterative reconstruction. MATERIALS AND METHODS: Eighteen radiologists blinded to phantom and study design interpreted randomized image data sets that contained 36 spherical simulated liver lesions of three sizes and three attenuation differences (5-mm diameter: 12, 18, and 24 HU less than the 90-HU background attenuation of the simulated liver insert; 10- and 15-mm diameter: 6, 12, and 18 HU less than the 90-HU background attenuation) scanned with four discrete exposure settings and reconstructed by using FBP and sinogram-affirmed iterative reconstruction. Response assessment included region-level lesion presence or absence on a five-point diagnostic confidence scale. Statistical evaluation included multireader multicase receiver operating characteristic curve analysis, with nonparametric methods and noninferiority analysis at a margin of -0.10. RESULTS: Pooled accuracy at 75% exposure for both FBP and sinogram-affirmed iterative reconstruction was noninferior to 100% exposure (P = .002 and P < .001, respectively). Subsequent exposure reductions resulted in a significant decrease in accuracy. When the smallest (5-mm-diameter) lesions were excluded from analysis, sinogram-affirmed iterative reconstruction was superior to FBP at 100% exposure (P = .011), and sinogram-affirmed iterative reconstruction at 25% and 50% exposure reduction was noninferior to FBP at 100% exposure (P ≤ .013). Reader confidence was greater with sinogram-affirmed iterative reconstruction than with FBP for 10- and 15-mm lesions (2.94 vs 2.76 and 3.62 vs 3.52, respectively). CONCLUSION: In this low-contrast low-attenuation liver lesion model, a 25% exposure reduction maintained noninferior diagnostic accuracy. However, detection was inferior with each subsequent exposure reduction, regardless of reconstruction method. Sinogram-affirmed iterative reconstruction and FBP performed equally well at modest exposure reduction (25%-50%). Readers had higher confidence levels with sinogram-affirmed iterative reconstruction for the 10- and 15-mm lesions.


Asunto(s)
Hepatopatías/diagnóstico por imagen , Fantasmas de Imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Programas Informáticos
15.
Radiology ; 272(3): 749-56, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24814177

RESUMEN

PURPOSE: To compare images acquired with 50% tube exposure with a dual-source computed tomographic (CT) scanner and reconstructed with sinogram-affirmed iterative reconstruction (SAFIRE) with 100% exposure images reconstructed with filtered back projection (FBP) for reader ability to detect stones, reader confidence, and findings outside the urinary tract. MATERIALS AND METHODS: In this HIPAA-compliant, institutional review board-approved study, imaging examinations in 99 patients with urolithiasis were assessed. Data from both tubes were reconstructed with FBP; data from the primary tube only were reconstructed with SAFIRE. Seven readers evaluated randomized studies for calculi in nine regions. Reader confidence was scored by using a five-point scale. Ancillary findings were noted. Nonparametric methods for clustered data were used to estimate the area under the receiver operating characteristic curves with 95% confidence intervals to test for noninferiority of 50% exposure with SAFIRE. RESULTS: Calculi were found in 113 locations (pyelocalyceal ureter, 86; proximal ureter, seven; midureter, four; distal ureter, 15; bladder, one) and not found in 752 locations. Mean area under the receiver operating characteristic curve for FBP was 0.879 (range, 0.607-0.967) and for SAFIRE, 0.883 (range, 0.646-0.971; 95% confidence interval: -0.025, 0.031). The SAFIRE images were not significantly inferior to FBP images (P = .001). Reader confidence levels for images with stones were similar with FBP and SAFIRE (P = .963). For the 52 patients who had extraurinary findings, readers reported them correctly in 74.4% (271 of 364) and 72.0% (262 of 364) of cases (P = .215) for FBP and SAFIRE, respectively. For the nine patients with potentially important findings per the reference standard, the detection rates were 44% (28 of 63) and 33% (21 of 63, P = .024), respectively. For the 43 patients with unimportant or likely unimportant findings, the false detection rates were 15% (44 of 301) and 14% (43 of 301, P = .756), respectively. CONCLUSION: The 50% tube exposure CT images reconstructed with SAFIRE were not inferior to 100% exposure images reconstructed with FBP for diagnosis of urolithiasis, without decreases in reader confidence.


Asunto(s)
Algoritmos , Almacenamiento y Recuperación de la Información/métodos , Protección Radiológica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Urolitiasis/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
BJU Int ; 114(3): 412-7, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24325283

RESUMEN

OBJECTIVE: To present the outcomes of active surveillance (AS) for renal angiomyolipomas (AMLs) and to assess the clinical features predicting delayed intervention of this treatment option. PATIENTS AND METHODS: We retrospectively reviewed the outcomes of patients diagnosed with AMLs on computed tomography (CT) who were managed with AS at our institution. The AS protocol consisted of 6- and 12-month, then annual follow-up visits, each one including a physical examination and CT imaging. Discontinuation of AS was defined as the need or decision for an active procedure during the follow-up period. Causes of delayed intervention, as well as the type of active treatment (AT), were recorded. Clinical features at presentation of patients failing AS were compared with those who remained under AS at the time of the last follow-up. Predictive factors of delayed intervention were analysed using univariate and multivariate Cox regression models. RESULTS: Overall, 130 patients were included in the analysis, of whom 102 (78.5%) were incidentally diagnosed, while 15 (11.5%) and 13 patients (10%) presented with flank pain and haematuria, respectively. After a mean (sd) follow-up of 49 (40) months, 17 patients (13%) discontinued AS and underwent AT. Patients who underwent delayed intervention were more likely to present with a higher body mass index, larger tumours and symptomatic disease. Angioembolization represented the first-line AT after AS (64.7%), whereas partial nephrectomy was adopted in 29.4% of patients. On the univariate analysis, risk factors for delayed intervention included tumour size ≥4 cm, symptoms at diagnosis, and history of concomitant or contralateral kidney disease. On the multivariate analysis, only tumour size and symptoms remained independently associated with discontinuation of AS. CONCLUSIONS: Tumour size and symptoms at initial presentation were highly predictive of discontinuation of AS in the management of AMLs. Selective angioembolization was the first-line option used for AT after AS was discontinued.


Asunto(s)
Angiomiolipoma/patología , Embolización Terapéutica , Dolor en el Flanco/patología , Hematuria/patología , Neoplasias Renales/patología , Vigilancia de la Población , Esclerosis Tuberosa/patología , Carga Tumoral , Adulto , Angiomiolipoma/epidemiología , Angiomiolipoma/terapia , Femenino , Estudios de Seguimiento , Humanos , Hallazgos Incidentales , Neoplasias Renales/epidemiología , Neoplasias Renales/terapia , Masculino , Persona de Mediana Edad , Examen Físico , Guías de Práctica Clínica como Asunto , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
18.
AJR Am J Roentgenol ; 200(6): 1298-303, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23701068

RESUMEN

OBJECTIVE: The purpose of this article is to determine the decrease in volume CT dose index (CTDI(vol)) and dose-length product (DLP) achieved by switching from fixed quality reference tube current protocols with automatic tube current modulation to protocols adjusting the quality reference tube current, slice collimation, and peak kilovoltage according to patient weight. MATERIALS AND METHODS: All adult patients who underwent CT examinations of the abdomen or abdomen and pelvis during 2010 using weight-based protocols who also underwent a CT examination in 2008 or 2009 using fixed quality reference tube current protocols were identified from the radiology information system. Protocol pages were electronically retrieved, and the CT model, examination date, scan protocol, CTDI(vol), and DLP were extracted from the DICOM header or by optical character recognition. There were 15,779 scans with dose records for 2700 patients. Changes in CTDI(vol) and DLP were compared only between examinations of the same patient and same CT system model for examinations performed in 2008 or 2009 and those performed in 2010. The final analysis consisted of 1117 comparisons in 1057 patients, and 1209 comparisons in 988 patients for CTDI(vol) and DLP, respectively. RESULTS: The change to a weight-based protocol resulted in a statistically significant reduction in CTDI(vol) and DLP on three MDCT system models (p < 0.001). The largest average CTDI(vol) decrease was 13.9%, and the largest average DLP decrease was 16.1% on a 64-MDCT system. Both the CTDI(vol) and DLP decreased the most for patients who weighed less than 250 lb (112.5 kg). CONCLUSION: Adjusting the CT protocol by selecting parameters according to patient weight is a viable method for reducing CT radiation dose. The largest reductions occurred in the patients weighing less than 250 lb.


Asunto(s)
Peso Corporal , Tomografía Computarizada Multidetector/métodos , Dosis de Radiación , Protección Radiológica/métodos , Radiografía Abdominal/métodos , Adulto , Protocolos Clínicos , Femenino , Humanos , Modelos Lineales , Masculino , Tomografía Computarizada Multidetector/instrumentación , Selección de Paciente , Radiografía Abdominal/instrumentación , Estudios Retrospectivos
19.
Front Surg ; 10: 1094806, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37251582

RESUMEN

Introduction and objective: This study aimed to identify clinical features representing predictive factors of active treatment (AT) compared to active surveillance (AS) for renal angiomyolipoma (AML). Patients and methods: From 1990 to 2020, patients referred to two institutions for a renal mass and diagnosed with an AML based on typical features on CT were included in the analysis. The study population was divided into two groups based on the treatment received: active surveillance (AS) or active treatment (AT). Age, gender, tuberous sclerosis syndrome, tumor size, contralateral kidney disease, renal function, year of diagnosis, and symptoms at presentation were assessed as potential predictive factors of active treatment using a logistic regression model in univariate and multivariate analyses. Results: In total, 253 patients (mean age 52.3 ± 15.7 years; 70% women; 70.9% incidentally diagnosed) were included in the analysis. One hundred and nine (43%) received AS, whereas 144 (57%) were actively treated. For univariate analysis, age, tuberous sclerosis complex syndrome, tumor size, symptoms at presentation, and contralateral kidney disease were found to be predictors of AT. Only tumor size (p < 0.001) and the year of diagnosis (p < 0.001) remained significant for multivariable analyses. The likelihood of being managed with AS evolved over the study period and was 50% and 75% when diagnosed before and after 2010, respectively. With respect to size, 4-cm and 6-cm tumors had a probability of 50% and 75% of being treated with AS, respectively. Conclusion: The present analysis from a high-volume institution provides evidence that the management of renal masses with typical radiological features of AML has markedly changed over the last three decades with a trend toward AS over AT. Tumor size and the year of diagnosis were significant factors for the treatment strategies.

20.
Radiology ; 262(1): 152-60, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22106359

RESUMEN

PURPOSE: To evaluate clinical outcomes, pathologic subtypes, metastatic disease rate, and clinical features associated with malignancy in Bosniak category IIF and III cystic renal lesions. MATERIALS AND METHODS: This retrospective study was institutional review board approved and HIPAA compliant. Informed consent was waived. Radiology and hospital information systems were searched for Bosniak IIF and Bosniak III lesions in computed tomographic (CT) reports from January 1, 1994 to August 31, 2009. Patients 18 years and older with unenhanced and contrast material-enhanced CT results and with lesions either surgically resected or with 1 year or more of surveillance were included. Data recorded were history of renal cell carcinoma, number of renal lesions, presence of a coexistent solid renal mass, surgical pathologic findings, and presence of metastatic disease from a renal malignancy. Sixty-two patients with 69 Bosniak IIF lesions and 131 patients with 144 Bosniak III lesions were identified. Proportions from independent groups were compared by using the Fisher exact test; continuous variables were compared by using a two-tailed two-sample t test or a Wilcoxon two-sample test. RESULTS: The malignancy rate of resected Bosniak IIF lesions was 25% (four of 16) and that for Bosniak III lesions was 54% (58 of 107) (P = .03). Thirteen percent (nine of 69) of Bosniak IIF lesions progressed at follow-up, and 50% (four of eight) of these resected cysts were malignant. History of primary renal malignancy, coexisting Bosniak category IV lesion and/or solid renal mass, and multiplicity of Bosniak III lesions were each associated with an increased malignancy rate in Bosniak III lesions. No patients developed locally advanced or metastatic disease from a Bosniak IIF or III lesion. CONCLUSION: Although the malignancy rate in surgically excised Bosniak IIF and Bosniak III cystic renal lesions was 25% and 54%, respectively, in our study, the malignancy rate was higher in patients with a history of primary renal malignancy or coexisting Bosniak IV lesion and/or solid renal neoplasm.


Asunto(s)
Carcinoma de Células Renales/diagnóstico por imagen , Enfermedades Renales Quísticas/diagnóstico por imagen , Neoplasias Renales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Carcinoma de Células Renales/patología , Carcinoma de Células Renales/terapia , Medios de Contraste , Progresión de la Enfermedad , Femenino , Humanos , Enfermedades Renales Quísticas/clasificación , Enfermedades Renales Quísticas/patología , Enfermedades Renales Quísticas/terapia , Neoplasias Renales/patología , Neoplasias Renales/terapia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA