Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Arthroscopy ; 31(2): 293-8, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25312766

RESUMEN

PURPOSE: The purpose of this study was to compare gap formation, strength, and stiffness of repaired radial tears of the meniscus treated using a new all-inside technique versus a traditional inside-out suture technique. METHODS: Radial tears were created in 36 fresh-frozen porcine menisci. Repairs were performed using a novel all-inside suture-based meniscal repair device or an inside-out technique. The repairs were tested for cyclic loading and load to failure. The displacement, response to cyclic loading (100, 300, and 500 cycles), and mode of failure were recorded, and the construct's stiffness was calculated. RESULTS: The all-inside repairs using the novel device resulted in a significantly lower displacement (gap formation) after 100, 300, and 500 cycles (P = .002, P = .001, and P = .001, respectively). The ultimate load to failure was significantly greater for the all-inside repairs (111.61 N v 95.01 N; P = .03). The all-inside repairs showed greater stiffness (14.53 N/mm v 11.19 N/mm; P = .02). The all-inside repairs failed most often by suture breakage (suture failure). The inside-out repairs failed most commonly when the suture pulled through the tissue (tissue failure) (P < .001). CONCLUSIONS: For repair of radial tears of the meniscus, the vertical suture configuration created by the all-inside technique resulted in lower displacement, higher load to failure, and greater stiffness compared with the horizontal inside-out technique. CLINICAL RELEVANCE: In a porcine specimen meniscus repair model, the biomechanical properties of a vertical all-inside technique were superior to that of a horizontal inside-out technique. Future studies of biomechanical and clinical outcomes in human meniscal repairs with this device are warranted to explore whether this repair method is valuable to clinical practice and patient outcomes.


Asunto(s)
Traumatismos de la Rodilla/cirugía , Meniscos Tibiales/cirugía , Animales , Fenómenos Biomecánicos , Modelos Animales de Enfermedad , Traumatismos de la Rodilla/fisiopatología , Meniscos Tibiales/fisiopatología , Técnicas de Sutura , Porcinos , Lesiones de Menisco Tibial , Cicatrización de Heridas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA