RESUMEN
This study aimed to evaluate the filler contents (FCs), flexural properties, depth of cure (DOC), wear resistance, and handling properties of different low-viscosity bulk-fill resin composites (LVBRCs) and to determine the correlations between the tested parameters. Six LVBRCs, Beautifil-Bulk (BBF), Bulk Base Hard (BBH), Bulk Base Medium (BBM), Filtek Bulk-Fill Flowable Restorative (FBF), G-ænial Bulk Injectable (GBI), and SDR flow+ Bulk-Fill Flowable (SDR) were used. The DOC and flexural property tests were conducted according to the ISO 4049 specifications. The flexural strength, elastic modulus, and resilience were determined in 12 specimens that were obtained from each of the 6 materials. Sliding-impact-wear testing was conducted by evaluating the wear facets of the specimens using a noncontact profilometer and by confocal laser scanning microscopy. The handling properties of the LVBRC was assessed via extrusion force and thread formation measurements. The DOC for the majority of the LVBRCs was approximately 4 mm. Although the FCs and mechanical properties were material dependent, some LVBRCs exhibited excellent flexural properties and wear resistance. The LVBRCs demonstrated a wide range of extrusion force and thread formation. Regarding the correlations between the tested parameters, extremely strong negative and positive correlations were observed for the DOC versus extrusion force, flexural strength versus elastic modulus, maximum depth versus volume loss, and maximum depth versus thread formation. In addition, strong correlations between FCs and DOC, resilience, wear resistance, and extrusion force were observed.
Asunto(s)
Resistencia Flexional , Fenómenos Mecánicos , Módulo de Elasticidad , Ensayo de Materiales , ViscosidadRESUMEN
We attempted to determine the effect of universal adhesive application time on dentin bond performance in different etching modes based on shear bond strength (SBS) tests and surface free energy (SFE) measurements. The five universal adhesives used were Adhese Universal (AU), Clearfil Universal Bond Quick (CQ), G-Premio Bond (GP), Scotchbond Universal (SU), and Tokuyama Universal Bond (TU). Bovine dentin specimens were divided into four groups of 10 for each adhesive. SBS and SFE were determined after applying the following surface treatments: 1) self-etch (SE) mode with immediate air blowing after adhesive application (IA treatment), 2) SE mode with prolonged application time (PA treatment), 3) etch-and-rinse (ER) mode with IA treatment, and 4) ER mode with PA treatment. Bonded specimens were subjected to SBS testing. The SFE of adhesive-treated dentin surfaces was measured after rinsing with acetone and water. Three-way analysis of variance revealed that dentin SBS values (p<0.001) were significantly influenced by the factors of adhesive type and application duration, but the factor of pre-etching was not significant (p=0.985). The manufacturer's instructions require longer application times for AU and SU, which showed significantly lower SBS values in IA than in PA treatment in both etching modes. However, the difference in the other adhesives was not significant between the IA and PA treatments in either etching mode. The total SFE (γS) was dependent on the adhesive and etching mode. The γS value of the initial group (SiC paper ground group) at baseline was 69.5 (mN·m-1) and that of the pre-etching group at baseline was 30.6 (mN·m-1). For all the adhesives, γS in SE mode showed significantly higher values than in ER mode, regardless of the application time. In SE mode, almost all universal adhesives tested showed lower γS values in PA treatment than in IA treatment. For ER mode, all the adhesives showed significantly higher γS values than those of the pre-etching baseline, regardless of the application time. Most adhesives did not show any significant differences in γS values between IA and PA treatments, regardless of etching mode.